Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Feb 2022, 6:00 pmClosed
GE (AF) AF Srinagar
Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
REPAIR / MAINTENANCE OF E/M WORKS IN MRS, MPH, DOODH GANGA POWER HOUSE AND OTHER ASSOCIATED WORKS UNDER AOR OF GE (AF) SRINAGAR AT AF STATION
2022_MES_499474_1
GE (AF) - 60/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE (AF) SRINAGAR
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) SRINAGAR
₹50,000
Yes
9 Mar 2022
5 Jan 2022
7 Feb 2022
5 Jan 2022
4 Feb 2022
19 Jan 2022
Amount
Note:- For All Items of This BOQ:- Work has to be executed at E&M installation, Electric shut will require to execute certain items of this Schedule, therefore Contractor is require to intimate Engineer-in-Charge at least 7 days in advance whenever shut down is require, Engineer-in-Charge will intimate to contractor four days in advance from the date of shut down provided by them. Contractor will manage manpower / tools / plant etc accordingly. No compensation etc will be paid by department in case shut down not provided by the department due to any reason. In case of any dispute Decision of Accepting officer shall be final binding & conclusive
Excavating in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation poles, stays, laying of cables etc for shaft, wells, cesspits, manholes, peir holes, etc or not exc. 10 Sqm on plan and getting out, complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick, using excavated soil complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
Supply and lay un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm complete all as specified and directed by Engr-in-Charge. Make:- MEHTAB TILES, PEARLESS INDUSTRIES, HINDMOZAIC OR STATE ELECTRICITY BOARD APPROVED MANUFACTURER.
Supply and lay factory made un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-Charge. Make:- MEHTAB TILES, PEARLESS INDUSTRIES, HINDMOZAIC OR STATE ELECTRICITY BOARD APPROVED MANUFACTURER.
M&L for Steel water tubing light grade of dia 40 mm galvanized with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete including taking down old pipe all as specified and directed by Engr-in-Charge.
M&L for Steel water tubing light grade of dia 50 mm galvanized with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete including taking down old pipe all as specified and directed by Engr-in-Charge.
M&L for Steel water tubing light grade of dia 80 mm galvanized with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete including taking down old pipe all as specified and directed by Engr-in-Charge.
M&L for Steel water tubing light grade of dia 100 mm galvanized with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete including taking down old pipe all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing, HT cable 11000 volts earthen grade XLPE insulated, multistranded aluminium conductor of size 95 Sqmm 3 Core, heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armored with an overall PVC sheathing of, as per IS-7098 (Part-I) 2011, laid in trenches, fixed along the poles or passed through GI pipe laid on floors, road etc fixed encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes,etc) for incoming and outgoing cables complete all as specified and as directed.
Supply, laying, jointing and testing, HT cable 11000 volts earthen grade XLPE insulated, multistranded aluminium conductor of size 120 Sqmm 3 Core, heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armored with an overall PVC sheathing of, as per IS-7098 (Part-I) 2011, laid in trenches, fixed along the poles or passed through GI pipe laid on floors, road etc fixed encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes,etc) for incoming and outgoing cables complete all as specified and as directed.
Note For item No 11 & 12:- This item will be used for tapping to GOD when GOD will be refixed / installed an appropriate height as per IEC / IS norms Quoted rate shall be deem to include cost of MS clamps with nuts, bolts washer etc.
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and all as directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and all as directed.
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and all as directed.
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and all as directed.
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through joint, heat shrink type, complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 sqmm complete all as specified and all as directed.
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through joint, heat shrink type, complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 sqmm complete all as specified and all as directed.
Make For Item No 13 to 19:- DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL
Supply & fix in repair Air break gang operated switch with 12 No's insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25 mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified including taking down old Air break gang operated switch . Make:- BHEL, PACTIL, OBLUM, ABB, JAIPURIA
Supply & fix in repair Lightning arrestor (set of three) HT metal oxide surge arrester polymeric type complete with all fittings, rated voltage 12 KV continuous operating voltage 11 KV, normal discharge current 10 KA, 65 KV discharge capacity etc, confirming to IEC-600994-2001 complete all as specified and all as directed. Make:- BHEL, PACTIL, OBLUM, ABB, JAIPURIA
Deployment of manpower / tools / machinery / plant for Dehydration / filtration of transformer oil of transformers, etc of various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength not less than 50 KV when measured at 2.5 mm gap for one minute complete all as specified and as directed by Engr-in-Charge.
Note- Quoted rates shall be deem to include for following :- (i) Oil for each transformer shall be tested after filtration and test result will be recorded before & after filtration of oil and signed by Engineer-in-Charge & contractor. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) New transformer oil as required shall be measured and paid separately under respective item as supply only.
Supply & filling Power Transformer Oil for toping up the level of oil having dielectric strength 60 KV during filling after initial filtration confirming to IS-335 complete all as specified and directed by Engineer-in-Charge.
Supply & filling Transformer Oil in 11KV / 433 Volt Step down 63 to 500 KVA line transformer in situ / at site for toping up the level of oil having dielectric strength 35 KV during filling after initial filtration confirming to IS-335 complete all as specified and directed by Engineer-in-Charge.
Note For Item No 22 & 23:- Transformer oil shall be supplied in sealed Containers. Make For Item No 22 & 23:- M&I MATERIAL (MIDEL) POWER LINK, POWER OIL, SAVITA
M&L for cleaning of surrounding area of E&M installation around the bldg , transformer, GOD LT panel by grass cutting manually or mechanically (Bush cutter) as per requirement basis and trimming as directed by Engr-in-Charge, including taking out all shrubs, saplings with bushes and any type of vegetation and removing from site, complete all as specified and directed.
Supply, laying, jointing and testing, LT cable 1100 volts XLPE insulated, multistranded aluminium conductor of size 10 Sqmm 4 Core, heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armored with an overall PVC sheathing of, as per IS-7098 (Part-I) 2011, laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed.
All as per item No 25 here-in-before but cable of size 16 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
All as per item No 25 here-in-before but cable of size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 25 here-in-before but cable of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 25 here-in-before but cable of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 25 here-in-before but cable of size 185 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 25 here-in-before but cable of size 240 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
S&F in repair Sign Board of size 1200 mm x 900 mm, fabricated 5 mm thick white Acrylic sheet with outer frame made of aluminium angle of size 25 mm x 25 mm x 2.5 mm, pasting 0.50 mm thick self adhesive vinyl sheet printed with Blue base colour and all the instruction printing in English alphabets, including hanging / mounting arrangement complete all as specified and directed by Engr-in-Charge.
S&F in repair Anti climbing devices spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters walk ways; railings; frame work at installation and similar work conforming to Fe.290. Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply & fix in repair 6 mm thick mild steel plain / chequered plate cut to size and fixed as in cable duct cover complete all as specified and as directed by Engr-in-charge.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint on 4/6 pole 11 KV HT structure
S&F in repair HT Danger notice plate of size 250 mm x 200 mm x 1.6 mm thick of mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed to pole with MS clamps, bolts and nuts of approved size complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete including demolition of old damaged PCC, complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in platform for VCB, transformer & similar work including weathering, slightly rounded or chamfered angles as directed with form work and finishing of all exposed surfaces complete including demolition of old platform all as specified and as directed.
M&L for cutting of existing road surfaces up to 100 mm deep & 300 mm wide and making good disturbed portion with 100 mm thick plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
M&L for taking out of inclined HT prestressed pole (11 metre height) of any description by excavation in any type of soil, demolition of old PCC of foundation & coping, refixing of same pole in true vertical position, including PCC 1:4:8 type D2, as in foundation, PCC 1:3:6 as in coping, and including returning filling, removal of surplus excavated soil & all debris to a distance not exceeding 50 metre complete all as specified and as directed by Engr-in-charge.
M&L for taking out of inclined LT prestressed pole (9.0 metre height) of any description by excavation in any type of soil, demolition of old PCC of foundation & coping, refixing of same pole in true vertical position, including PCC 1:4:8 type D2, as in foundation, PCC 1:3:6 as in coping, and including returning filling, removal of surplus excavated soil & all debris to a distance not exceeding 50 metre complete all as specified and as directed by Engr-in-charge.
M&L in replacement of damaged / rusted door, front and back of LT Panel fabricated with 3.15 mm CRCA sheet including fabrication wks and all fitting & fixtures such as hinges, locking arrangement, painting with two coat synthetic enamel paint over one coat red oxide primer complete all as specified and as directed by Engr-in-charge.
Deployment of manpower / tools / machinery etc for Calibration of CTs & PTs unit (33KV) (Make : Electric field) through approved OEM / State electricity board agency as per IEC / IS norms complete all as specified and as directed by Engr-in-charge.
Supply & fix in repair breather assembly with fresh filling of silica-gel (colour of silica gel should be deep sky blue) in non metallic breather of transformer of capacity 63 to 160 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair breather assembly with fresh filling of silica-gel (colour of silica gel should be deep sky blue) in non metallic breather of transformer of capacity 200 to 400 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair breather assembly with fresh filling of silica-gel (colour of silica gel should be deep sky blue) in non metallic breather of transformer of capacity 500 KVA, complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old painted surface of steel tubular poles height approximately 8.5 meter above GL including cross arms and bracings and applying two coat aluminium paint and rewriting pole number with synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surface of steel tubular poles height approximately 9.5 meter above GL including cross arms and bracings and applying two coat aluminium paint and rewriting pole number with synthetic enamel paint complete all as specified and directed.
S&F in repair LT jumper made of ACSR conductor (Rabbit) from LT feeder of 2 / 4 pole structure up to 4.0 RM incoming / outgoing including PVC sleeve, Lugs , nut bolts and washers complete all as directed.
Surface dressing n exc 15 cm deep in any type of soil, including trimming of ground, to remove vegetation and / or small inequalities complete.
Material and labour for spreading of clean & dry stone aggregate of nominal size not more than 25 mm (free from organic impurities) laid around 4 / 6 pole HT structure / surrounding area of outdoor RMU, manually without damaging any equipments, cable or parts, spreading & leveling of finished gravel uniformly in layers n. exc 150 mm thick, complete all as specified and directed. Note:- Preparation of ground level for laying of aggregate will be measured and paid separately vide BOQ item No 53
M&L for preparation of old painted steel surface of LT feeder pillar Box, 440 Volts, 3 phase of any size / location and applying two coats of synthetic enamel paint complete all as specified and directed Engineer-in-Charge.
Supply and fix in replacement male contact / moving contact for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supply and fix in replacement female contact / moving contact for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Deployment of manpower / tools etc for maintenance of gang operated air break isolators switch out door type 9 / 12 insulators double stack, triple pole, rotating type double break per pole for 11000 volts, 3 phase, 50 Hz, AC supply system having 200 / 400 Amps capacity by oiling, greasing, adjustment of lever and making the same smooth functional complete all as specified. complete all as specified and directed
Taking out HT / LT XLPE under ground Cable of size 70 to 120 Sqmm from existing trench including disconnecting from existing connection, excavation, removal of sand, bricks cable cover, etc at various location of E/M installation complete all as specified and as directed by Engr-in-charge.
Taking out HT / LT XLPE under ground Cable of size 150 to 240 Sqmm from existing trench including disconnecting from existing connection, excavation, removal of sand, bricks cable cover, etc at various location of E/M installation complete all as specified and as directed by Engr-in-charge.
Taking out HT / LT XLPE under ground Cable of size 300 Sqmm from existing trench including disconnecting from existing connection, excavation, removal of sand, bricks cable cover, etc at various location of E/M installation complete all as specified and as directed by Engr-in-charge.
Laying only HT / LT XLPE under ground Cable of size of size 70 to 120 Sqmm retrieved from BOQ Item No 59, laid in other location in trenches / duct passing through pipe / duct or fixed on pole and connecting with suitable size of lugs and cable glands etc, & testing complete
Laying only HT / LT XLPE under ground Cable of size 150 to 240 Sqmm retrieved from BOQ Item No 60, laid in other location in trenches / duct passing through pipe / duct or fixed on pole and connecting with suitable size of lugs and cable glands etc, & testing complete
Laying only HT / LT XLPE under ground Cable of size 300 Sqmm retrieved from BOQ Item No 61, laid in other location in trenches / duct passing through pipe / duct or fixed on pole and connecting with suitable size of lugs and cable glands etc, & testing complete
Note for Item No 62 to 65: (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this BOQ. (ii) Straight through joint wherever required will be measured and paid separately
Deployment of manpower / tools / crane etc for shifting of Power transformer of capacity 6.3 MVA, by disconnecting all incoming & out connecting shifting the transformer to a distance not exceeding 175 metre, placing / installation of transformer over existing platform, connecting all incoming & outgoing connecting from existing busbar, including testing / commissioning complete all as specified and as directed by Engr-in-charge.
M&L for Aluminium conductor, steel reinforced (ACSR) Code name : Weasel conductor for HT feeders on steel tubular / PCC poles, stretching without kinks and bends including binding wire including taking down old conductor of any type shape and size, complete all as specified. Make: JAIPURIA, ALIND, ICC, NICCO
M&L for Aluminium conductor, steel reinforced (ACSR) Code name : Squirrel conductor for HT feeders on steel tubular / PCC poles, stretching without kinks and bends including binding wire including taking down old conductor of any type shape and size, complete all as specified. Make: JAIPURIA, ALIND, ICC, NICCO
M&L for preparation of old painted steel surface of LT / HT Panel, VCB of any description by cleaning, rubbing and making surface smooth and applying two coat synthetic enamel paint complete all as specified and directed.
Supply and fixing in replacement of GI Bracket made of 40 mm dia GI pipe medium grade 1. 5mtr long suitable for street light for steel / RCC pole as per site requirement including suitable nut, bolt, washers and clamps complete all as specified and directed by Engineer-in-Charge
S&F in replacement of PVC separator suitable for 1100V four ACSR Conductor feeder complete all as specified and directed by Engineer-in-Charge
S&F in repair timer distribution board with analog time switches complete of rating 65 Amps 3 pole 230 Volts 415 volt including taking down existing complete all as specified and directed by Engr in charge. Make :- Indoasian Cat part No. TL065ABO or equivalent Cat No of Make C&S / HPL / Havells
Deployment of manpower / tools etc for Restretching / re fixing the existing LT OH / Lines ACSR conductor of any type and size including disconnecting binding wire on insulator, rebinding properly to avoid tension / fitting bending of poles, complete all as specified and directed by Engrr-in-Charge. Note:- Each line of conductor will be measured & paid separately.
Supply & fix in repair pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix in repair pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix in repair disc type, porcelain, vitreous white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 145 mm height, 255 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix in repair shakle type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 100 mm height, 115 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix in repair conservator tank indicator as per existing capacity of transformer 63 to160 KVA complete all as specified and directed by Engr-in-charge.
Supply & fix in repair conservator tank indicator as per existing capacity of transformer 200 to 400 KVA complete all as specified and directed by Engr-in-charge.
Supply & fix in repair conservator tank indicator as per existing capacity of transformer 500 KVA complete all as specified and directed by Engr-in-charge.
M&L for taking down GI bracket with clamp of street light / perimeter security light from RCC / tubular pole of any size / location, preparation of old painted steel surface and applying two coats of synthetic enamel paint and refixing the same in same location with suitable size of nut, bolt and clamps etc complete all as specified and directed Engineer-in-Charge.
M&L for preparation of complete outer steel surface of transformer of capacity 63 to 100 Kva by emery paper to remove all dust, dirt, oil etc and making surface smooth & clean applying two coats of synthetic enamel paint complete all as specified & as directed by Enginee - in- Charge.
M&L for preparation of complete outer steel surface of transformer of capacity 160 to 315 Kva by emery paper to remove all dust, dirt, oil etc and making surface smooth & clean applying two coats of synthetic enamel paint complete all as specified & as directed by Enginee - in- Charge.
M&L for preparation of complete outer steel surface of transformer of capacity 400 to 630 Kva by emery paper to remove all dust, dirt, oil etc and making surface smooth & clean applying two coats of synthetic enamel paint complete all as specified & as directed by Enginee - in- Charge.
Electromech Engineers
M/S NEW FAROOQ TRADERS
M/S ZAHOOR ENTERPRISES
M/s Jaipal Associates
M/S A Q ENTERPRISES
CHINAR CONSTRUCTION TRADERS
M/s PARVAZ CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .