Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L- 1₹22.4 LAccepted-Finance | ₹22.4 L | L- 1 | Accepted-Finance Being L- 1 |
| 2 | L- 2₹26.3 L+₹3.9 L (17.3%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹26.3 L+₹3.9 L (17.3%) | L- 2 | Rejected-Finance Not being L- 1 |
| 3 | L- 3₹30.9 L+₹8.5 L (37.8%)Rejected-Finance 408 409 HAASH BUSINESS CENTER NR ANKUR SCHOOL FATEHPURA PALDI AHMEDABAD 380007 | AHMADABAD | GUJARAT | 380007 | ₹30.9 L+₹8.5 L (37.8%) | L- 3 | Rejected-Finance Not being L- 1 |
| 4 | L- 4₹31.4 L+₹8.9 L (39.9%)Rejected-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹31.4 L+₹8.9 L (39.9%) | L- 4 | Rejected-Finance Not being L- 1 |
| Sl No | Description | Qty | Unit | ECS ENGINEERING PVT LTD L4 | Awasthi Electric Works L2 | Yash Energy Pvt. Ltd L3 | ARNAV ENGINEERING CONSULTANCY SERVICES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | SH I :- Internal Electrical Works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required..
Group C | 24 | Point | 2,900 ₹69,600 | 1,700 ₹40,800 | 1,944 ₹46,656 | 1,250 ₹30,000 Lowest |
| 2.00Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. | |||||||
| 2.10 | Group A | 26 | Point | 1,250 ₹32,500 | 750 ₹19,500 Lowest | 918 ₹23,868 | 750 ₹19,500 Lowest |
| 2.20 | Group C | 8 | Point | 1,800 ₹14,400 | 1,000 ₹8,000 | 918 ₹7,344 | 850 ₹6,800 Lowest |
| 3.00Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | |||||||
| 3.10 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 200 | Mtrs. | 370 ₹74,000 | 250 ₹50,000 | 297 ₹59,400 | 210 ₹42,000 Lowest |
| 3.20 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 500 | Mtrs. | 461 ₹2,30,500 | 300 ₹1,50,000 Lowest | 415 ₹2,07,500 | 385 ₹1,92,500 |
| 3.30 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire | 60 | Mtrs. | 1,070 ₹64,200 | 800 ₹48,000 | 961 ₹57,660 | 550 ₹33,000 Lowest |
| 3.40 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 30 | Mtrs. | 1,467 ₹44,010 | 1,000 ₹30,000 | 1,328 ₹39,840 | 650 ₹19,500 Lowest |
| 4.00Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||||
Tender Value
₹28.4 L
EMD Value
₹85,400
Closing Date
25 Jul 2026, 6:00 pmClosed
AGM (Engg. Elect.), AAI
AGM (Engg. Elect.), Airports Authority of India, Chandigarh- 160003
Construction of Glide Path and Localizer Building and other associated works inside Airforce Area at Chandigarh Airport. SH- SITC of LT panel, Split AC and internal wiring works
2026_AAI_282923_1
AAI/CHD/Engg. (E)/ILS Electrical/NIT-02/2026-27
Open Tender
Electrical Works
Item Rate
60 days
Inside Airforce Area at Chandigarh Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹85,400
18 Aug 2026
3 Jul 2026
27 Jul 2026
4 Jul 2026
25 Jul 2026
4 Jul 2026
4 Jul 2026 - 10 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SH I :- Internal Electrical Works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required..
Group C | 24 | Point | - | - |
| 2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. | |||||
| 2.1 | Group A | 26 | Point | - | - |
| 2.2 | Group C | 8 | Point | - | - |
| 3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | |||||
| 3.1 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 200 | Mtrs. | - | - |
| 3.2 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 500 | Mtrs. | - | - |
| 3.3 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire | 60 | Mtrs. | - | - |
| 3.4 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 30 | Mtrs. | - | - |
| 4Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
DNITILSELCT.pdf
Tender Documents • 8.88 MB
BOQ_330019.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .