Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC AOC Done | |
| 2 | L2₹33.4 L+₹2.5 L (8.17%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹34.9 L+₹4.1 L (13.1%)Rejected-Finance 0 0 BAMUNPARA VILLAGE TOWN BALITIKURI CITY HOWRAH HOWRAH WEST BENGAL 711113 INDIA | HOWRAH | WEST BENGAL | 711113 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹36.6 L+₹5.8 L (18.6%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance that the bid is not L1 | |
| 5 | L5₹41.6 L+₹10.7 L (34.7%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L5 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹85,080
Closing Date
7 Jun 2021, 1:00 pmClosed
EE II KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Providing of Electrical power supply including illuminating the area and necy electrical wiring for two nos Oxygen Generating station near Green Building under MCH Kolkata
2021_WBPWD_331588_1
WBPWD/EEII/KNHED/NIQ-30/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹85,080
8 Nov 2021
20 May 2021
9 Jun 2021
22 May 2021
7 Jun 2021
22 May 2021
Amount
Feeder Piller Box:- Supply and Installation of Hooded Outdoor type Feeder Piller Box IP-66 Protection class of suitable size with both side opening door and locking arrangement made of 5mm thick M.S plate fixed to be on massonary base as per approved draawing & dirrection of EIC. The box should be comprising of the following accessories & PWD approved make & brand : SITC of Cubical type floor mounted LT panel Board of suitable dimension comprising of the following electrical accessories fabricated from 25X25X5 mm MS angle and 14 (weight carrying main body) & 16 (partition, door etc.) SWG CRC Sheet with necy. welding incl painting with 7 tank process 2 coats of Synthetic Enamel paint (Siemens Grey) over 1 coat of RO primer as per GS. Heat Chamber treated. Should have Body earthing terminal etc and with proper door lock arrangement. Panel Protection Class IP 65. hinge type door with locking arrangement with telescopic screw. Panel should have continious earth busbar for Body earthing and base channel will be 75mm x 40mm x 6mm (painted with Black Japan after derusting) A. INCOMING:-- 1) S & F 415V, Range 320-800A , 50kA, MCCB - 2 nos. (for panel incomming) With Microprocessor release (MTX1.0, TYPE DN4-1250N make -- L&T / Schnieder / ABB / Siemens) with extended ROM and panel door mounted key lock for extended ROM (For mechanical inter locking one source at a time), spreader terminal etc as required. B. BBC:-- S & F 415V, 1000A (4x(80x10 mm)), 4 Bar Copper BBC with heat sinkable sleeve with proper colour coding --- 1 Item. (Dimension as per approved drawing & dirrection of EIC)
C. OUTGOING:-- 1) S&F 415V, range 250-320A, 36kA MCCB (Mk. - L&T, Type DN3B-400D, CM98403OOQOOG, with thermal magnetic release / Schneider / ABB / Siemens) - 4 (four) nos. 2) S&F 415V, range 125A, 36kA MCCB with thermal magnetic release (Mk. - L&T / Schneider / ABB / Siemens) - 2 (two) nos. D. METERING:-- 1) S & F digital multifunction meter (L&T, MFM5010 LED meter CI 1.0 with RS485, cat no-- WL501011OOOO/Schneider Conzerv-EM6400NG)---5 nos (for Bus Bar and 250A outgoings) 2) S & F 1000/5 A, 15VA C.T. --- 3 nos (for BBC) (Mk. AE / Kappa) 3) S & F 450/5 A, 10VA C.T. --- 12 nos (Mk. AE / Kappa) 4) S & F indicating lamp (RYB) --- 15 nos (Mk. Siemens / L&T / ABB) 5) S & F 2A MCB --- 15 nos (Make L&T) 6) S & F 20W LED lamp with necy. arrangement for ON & OFF while opening & closing of doors of FP --- 2 nos.
CABLE ALLEY : cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection.
INTERCONNECTION Inter connection to be made same with suitable size Cu Bar in between Incomming & Outgoing MCCB to busbar respectively. For 125A MCCB suitable size Cu wires are to be provided & metering circuit with 1.5 sq mm single core stranded FRLS PVC copper wire, CT secondary 2.5 sqmm Cu wire with proper copper socketing & taping ( R Y B & N). All nut bolts are of Stainless steel type. (as per approved drawing)
Cu wires should be terminated with suitable sockets / lugs incl. 2 nos earthing terminals by 25X6mm G.I. flat and errection of Feeder Piller Box of above size on 10" brick padestal of 24" height (600mm bellow Goround level and 600mm above G.L) incl. sand cement plastering and neat cement finishing. Inside the brick padestalwill be filled up by loose sand where the incoming & outgoing cable will be rest. The Feeder Pillar box is to be painted with 2 coats of synthetic enamel painting (Shade will be Pebble Grey No. RAL 7032 both inside and outside. ) over one coat of RO primer as per direction of EIC. Note: 1. All bolts/washers/nuts etc must be are of Stainless steel type and washers must be spring type. 2. An Auto Cadd Generated Drawing has to be Approved from the end of EIC before starting construction of Panel regarding the drawing / design and specification of the panel with BOM before starting of construction of Panel. Make, cat no of all items must be approved prior any execution/manufacturing work. Test reports of each MCCBs and others should be submitted along with the drawing for necy. approval from EIC. 2. Panel Manufacturer should have 2400A CPRI Certificate and to be showed in original during submission of drawing.
LT cable:-- (supply & delivery) Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab) as mentioned below as per choise of EIC:- a. 4 core 300 sqmm (from SSB SS & Green SS to FP)
b. 4 core 240 sqmm (Form From FP to O2 Generating Station)
c. 4 core 185 sqmm (from SSB LT Panel to Fire Pump Panel)
d. 4 core 70 sqmm (for FP to VTPN)
e. 4 core 25 sqmm (from VTPN to PDB)
f. 2 core 6 sqmm (Compound Light)
Laying through masonary trench:- Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand (vide page no F-3 item no 4(b))
Laying through cable tray Laying of cable of following sizes on existing cable tray/L- channel angle and binding with suitable size GI wire/or D-clamp incl. with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, as mentioned below as to GS:- Vide page no F 3 Item no 6 a. Above 150 sqmm
Laying of cable on wall/surface with shaddles/clamps:- Laying of cable of following sizes on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting as mentioned below as to GS:- Vide page no F 1 Item no 2 a. 4 core 185 sqmm
b. 4 core 70 sqmm
c. 4 core 25 sqmm
d. 2 core 6 sqmm
cable Gland:- Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : vide page no F-4 item no 7 a. 2 core 6 sqmm
b. 4core 25 sqmm
c. 4 core 70 sqmm
d. 4 core 300 sqmm
e. 4 core 185 sqmm
f. 4core 240 sqmm
Finshing:- Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : vide page on F-5 item no 8b a. 2 core 6 sqmm
b. 4core 25 sqmm
c. 4 core 70 sqmm
d. 4 core 300 sqmm
e. 4 core 185 sqmm
f. 4core 240 sqmm
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For soft soil (Vide page no G 1 Item no 1.a.)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (Vide page no G 1 Item no 2.a ) By ISI-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per GS. Vide page no G 2 Item no 4.c
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. as to GS. Vide page no G 3 Item no 5.e.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. (Vide page no G 2 Item no 3.a)
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as to GS. Vide page no G 2 Item no 3.b
Distribution wiring:- Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire (Mk. Havells / Polycab / KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe (HDPE) [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate (all Mk. Anchor, Roma/ Legrand / Schneider) making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] as per G S. (Sch. Book page-E-25, Sl. No.-5) a. Av. run 10 mtr
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (mk. - KEI / Havells / Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. (Vide page no E 14 Item no 1.a) a. 2 x 2.5 sqmm + 1 x 1.5sqmm (for computer board, PP)
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S . Vide page no F5 Item no 9 a. 2.5 sqmm
VTPN,HTPN,SPNDBs,Change Over switches Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-11 item no 15) a. 4 way Enclosure (607913)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-10 item no 14) a. 6 way Enclosure (607716)
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-5 item no 6) a. 415 V, 63A FP for PBDB
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-8 item no 10) a. 125A FP for VTPNDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-6 item no 7) a. 6A - 32A SP MCB for PBDB
b. 63A TP MCB for VTPNDB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment Make-Legrand, as to GS. (Mk. Legrand / Schneider / L&T) (Vide page no D-12 item no 16) a. 6 way PBDB
b. 4 way VTPNDB
Plugs & Sockets:- Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire (Mk. Havells / Polycab / KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works as per G S. (all Mk. Anchor, Roma/ Legrand / Schneider) (Vide page no -E-24 Item no-3) a. On board
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch, 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as to GS. (all Mk. Anchor, Roma/ Legrand / Schneider) as per direction of EIC. Vide page no E 18 Item no 13
Supply of light fittings:- S/D 4feet single commercial LED type fluroscent light fittings complete with all accessories with 1X20W (cat no LTT8-20) LED tube lamp corresponding to ( make Crompton cat no IGP131LT8-16 20W / Philips / Wipro)
S/D of LED Flood light with IP-66 protection (Make-Crompton, Cat no LFL-70-CDL/60-M,PROFILE+NEO / Philips / Wipro)
Supply of fan fittings:- S & D only 1200mm sweep ceiling fan (Mk - CG HS PLUS, 5 star rated / Usha Technix, 5 star / EPC - As per Choice of EIC) complete with blades, canopy, fork, rubber bush, down rod etc.
Fixing of light fitings:- Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.Vide page no C-2 Item no 17
Fixing of LED flood light fittings on wall with angle iron frame structure incl. suitable size of bolts and nuts and all other accessories required for hanging or mounting the fitting incl. necy. connections by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length thrugh flexible conduit as per direction of EIC.
Fixing of fan fittings:- Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting. Vide page no D 14 Item no 29
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Anchor, Roma/ Legrand) on existing Modular GI switch board with top cover plate incl. making necy. connections etc etc. as per G.S. (Vide page no E-18, Item no 10)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. (Vide page no C-3, Item no 21.a.
S & F fan down rod (14 SWG) incl. necessary connection wire (2X1.5sqmm cu wire) and painting the down rod as per direction of EIC
Miscelleneous :--- Supply & Installation AC timers consisting of the following ; 1. Double door SPNDB Box -12 Way - 1no. 2. 40A Contactor (Make - LT) - 1no. 3. Analog timer of 24 hr. Capacity ( Make -LT) - 1no. 4. DPMCB (25 Amp, "C" Curve) (Make - LT) - 1no. 5. By pass Switch / MCB arrangement - 1no. 6. Proper interconnection arrangement with 4 sq.mm. PVC copper wire with proper socketing (Make- Finolex/ Havells) 7. 240 V, 40 A, 300mA DP RCCB (make-- L&T, cat no-- BG204030) --1 no
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Vide page no D-2, Item no 3a of GS) a. 320A (Mk. L&T / ABB / Schneider / Siemens)
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC
Supplying & laying medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (vide page no F-6 item no 11) a. 100 mm
S&F 24" long MS frame made of 30x30x5mm MS angle with both side D-clamp (suitable for holding 4Cx300sqmm A/Al cables), drilled holes with nuts, bolts, washers and grouted in the cement concrete on wall complete and mending good the damages as per direction of EIC.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (here RCC Road Cutting infront of Gate 5, KMCH for passing of 2 Nos. 4Cx300sqmm A/Al Cables)
Cost for wall cutting in different area, dismantling EI work, cables etc., others civil work as per site requirement, cleaning all the sites & restoring the area (for Public Use) & remove all the rubbish including road cutting rubish (related with this work) outside hospital (KMCH) premises as per direction of EIC.
(Rate should be quotated including all taxes and duties)
SIMPSON AND FERRIS PVT LTD
M/S UNIVERSAL ENGINEERING CO
S. A. ENTERPRISE
Electromech Engineers Co-Operative Society Ltd.
ALPHA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .