Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAdmitted-Fee/PreQual/Technical/Finance 10TH FLOOR UNIT 2 TECHNIPLEX 2 VEER SAVARKAR FLYOVER S V ROAD GOREGOAN WEST MUMBAI 400 062 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400062 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹13.7 L+₹2.8 L (25.5%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | VAV Airconditioning L1 | Mr. Srinivas R Gubbala L2 |
|---|---|---|---|---|---|
| 1.00 | Carrying out shifting of the existing Air Handling Unit (AHU) from the existing location to the new location as instructed by EIC, by isolating the chilled water connections and draining the water from the pipeline. Cutting the existing chilled water piping along with butterfly and balancing valves, ‘Y’ strainers, pressure and temperature gauges, and other accessories in a proper manner. Removing the canvas connection, connected plenum and ducting. Removing the cable connections in a proper manner. Lifting the AHU from its base and relocating it to the designated location and placing it back on the foundations. Refitting the chilled water piping connections along with butterfly and balancing valves, ‘Y’ strainers, pressure and temperature gauges, and other accessories. Carrying out leak testing to ensure leak-proof joints. Refitting the plenum and ducting at the new location as per the AHU position. Carrying out cabling, recommissioning and testing of the AHU for proper operation as per standard. Removing and disposing out of TMH premises, all deberies and insulation scrap generated while carrying out the work is in the scope of the agency | 1 | Nos. | 73,013 ₹73,013 Lowest | 1,81,500 ₹1,81,500 |
| 2.00Chilled water piping out of M.S. heavy class ERW C -class pipe (pressure rating PN 16) confirming to relevant IS 1239 Code upto 150 mm dia pipes, from 150 mm and above upto 2S0 mm dia 6 mm thick pipes and above 250 mm dia 6-8 mm thick pipes, with necessary fittings, teak wood gutties for indoor and hard puff blocks for outdoor pipes, elbows, tees, reducers. Suitable GI supports as specified.Insulated with 50 mm thick upto 250 dia mm pipe and 75 mm above 250 mm dia -pipe , valves and fittings with TF quality thermocole of minimum density of 20 kg/cu mtr The insulating shall be fixed with 85/25 grade hot bitumen or CPRX compound applied uniformly on pipe and insulation surface, hessian cloth, wire mesh, 12 mm thick layer of sand cement plaster and 26 gauge commercial grade aluminium cladding. Pipe make - Tata / Jindal / SAIL | |||||
| 2.01 | 65 mm dia pipe | 10 | Rmt | 2,968 ₹29,680 Lowest | 5,784.6 ₹57,846 |
| 2.02 | 50 mm dia pipe | 10 | Rmt | 2,420 ₹24,200 Lowest | 5,161.2 ₹51,612 |
| 2.03 | 40 mm dia pipe | 10 | Rmt | 1,970 ₹19,700 Lowest | 4,452.7 ₹44,527 |
| 2.04 | 25 mm dia pipe | 15 | Rmt | 1,454 ₹21,810 Lowest | 2,969.7 ₹44,545.5 |
| 3.00 | Supply and Installation of 5 mm wall thickness PVC drain piping for Air handling unit with all fittings and supports, saddle, pressure clamps etc with 9 mm thick tubular type nitrile insulation wrapped with glass cloth dipped in adhesive recommended by manufacturer.
50 mm dia | 10 | Rmt | 894 ₹8,940 Lowest | 1,815.5 ₹18,155 |
| 4.00Supply, installation, balancing and commissioning of factory fabricated 180 GSM GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Make- Jindal / Sail / Tata | |||||
| 4.01 | 24Gauge GI ducting | 100 | SQM | 1,354 ₹1,35,400 Lowest | 1,483 ₹1,48,300 |
| 4.02 | 22Gauge GI ducting | 125 | SQM | 1,584 ₹1,98,000 Lowest | 1,969 ₹2,46,125 |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
21 Nov 2026, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OIC, Engineering, TMC on behalf of Director, TMC
Engineering Department, 6th floor, Service Block, TMH, Parel
Provision of Air Conditioning for new CT Scan at GJB Basement, TMH, Parel
2026_TMC_933720_1
TMC/ENG/AC/CT Scan/GJB/26/30
Limited
Machineries/ Mechanical Engg Items
Works
21 days
TMH, Parel
As per tender document
6 documents required · 6 mandatory
₹0
₹22,000
25 Nov 2026
9 Nov 2026
23 Nov 2026
9 Nov 2026
21 Nov 2026
12 Nov 2026
9 Nov 2026 - 11 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Carrying out shifting of the existing Air Handling Unit (AHU) from the existing location to the new location as instructed by EIC, by isolating the chilled water connections and draining the water from the pipeline. Cutting the existing chilled water piping along with butterfly and balancing valves, ‘Y’ strainers, pressure and temperature gauges, and other accessories in a proper manner. Removing the canvas connection, connected plenum and ducting. Removing the cable connections in a proper manner. Lifting the AHU from its base and relocating it to the designated location and placing it back on the foundations. Refitting the chilled water piping connections along with butterfly and balancing valves, ‘Y’ strainers, pressure and temperature gauges, and other accessories. Carrying out leak testing to ensure leak-proof joints. Refitting the plenum and ducting at the new location as per the AHU position. Carrying out cabling, recommissioning and testing of the AHU for proper operation as per standard. Removing and disposing out of TMH premises, all deberies and insulation scrap generated while carrying out the work is in the scope of the agency | 1 | Nos. | - | - |
| 2Chilled water piping out of M.S. heavy class ERW C -class pipe (pressure rating PN 16) confirming to relevant IS 1239 Code upto 150 mm dia pipes, from 150 mm and above upto 2S0 mm dia 6 mm thick pipes and above 250 mm dia 6-8 mm thick pipes, with necessary fittings, teak wood gutties for indoor and hard puff blocks for outdoor pipes, elbows, tees, reducers. Suitable GI supports as specified.Insulated with 50 mm thick upto 250 dia mm pipe and 75 mm above 250 mm dia -pipe , valves and fittings with TF quality thermocole of minimum density of 20 kg/cu mtr The insulating shall be fixed with 85/25 grade hot bitumen or CPRX compound applied uniformly on pipe and insulation surface, hessian cloth, wire mesh, 12 mm thick layer of sand cement plaster and 26 gauge commercial grade aluminium cladding. Pipe make - Tata / Jindal / SAIL | |||||
| 2.01 | 65 mm dia pipe | 10 | Rmt | - | - |
| 2.02 | 50 mm dia pipe | 10 | Rmt | - | - |
| 2.03 | 40 mm dia pipe | 10 | Rmt | - | - |
| 2.04 | 25 mm dia pipe | 15 | Rmt | - | - |
| 3 | Supply and Installation of 5 mm wall thickness PVC drain piping for Air handling unit with all fittings and supports, saddle, pressure clamps etc with 9 mm thick tubular type nitrile insulation wrapped with glass cloth dipped in adhesive recommended by manufacturer.
50 mm dia | 10 | Rmt | - | - |
| 4Supply, installation, balancing and commissioning of factory fabricated 180 GSM GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Make- Jindal / Sail / Tata | |||||
| 4.01 | 24Gauge GI ducting | 100 | SQM | - | - |
| 4.02 | 22Gauge GI ducting | 125 | SQM | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BOQ_981204.xls
BOQ • 0.28 MB
corrigendum01.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .