| 1 | L1₹26.7 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.3 L+₹4.2 L (14.8%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.1 L+₹8.0 L (28.5%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹36.4 L+₹8.3 L (29.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹37.3 L+₹9.2 L (32.6%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
17 Nov 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Repair/Maint of Solar Water Heater, Electric Geyser and Internal Electrification at Air Force Station Jaisalmer
2020_MES_388845_1
8697/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹79,000
Yes
9 Dec 2020
22 Oct 2020
19 Nov 2020
22 Oct 2020
17 Nov 2020
4 Nov 2020
Amount
M&L for complete servicing of Solar Water Heater including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking/ repairing leakage of inlet/ outlet pipes of Solar Water Heater complete all as specified and directed. (Make :- Solar Maxx/ Solchrome/ Tata BP).
M&L for replacement of old unserviceable Solar Panels or collectors suitable for Solar Water Heater Capcity 500 Ltr per day including its installation with support of angle iron, welding works, nuts, bolts etc with other material required to complete the work including testing after installation complete all as specified and directed.
S&F in replacement of Solar evacuated tube of Solar Water Heater as per existing suitable for 330 LPD complete with washer etc complete all as specified and directed.
M&L for Soler Water Heating rod of capacity 2KW to 3 KW as per existing complete all as specified and directed . Make :- Solar Maxx/ TATA BP
M&L in replacement of sheet metal enclosures for DBs when MCBs to be used 2 way SPN complete all as specified and directed.
S&F in replacement of MCB, 6 to 32 Amp, Single Pole, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4085 95 or equivallent
S&F in replacement of MCB, 6 to 32 Amp, Single Pole with neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 17 or equivallent
S&F in replacement of MCB, 40 Amp, Single Pole with Neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 18 or equivallent.
S&F in replacement of MCB, 63 Amp, Three Pole, 415 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 61 or equivallent.
S&F in replacement of MCB, 63 Amp, Three Pole with neutral, 415 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 61 or equivallent.
M&L in replacement of 25mm bore Unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed
S&F in replacement uPVC Gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 25mm bore pipe line complete all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks, three layered, white coloured (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position and including disconnecting & taking down the existing unserviceable water tank complete all as specified and directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks, three layered, white coloured (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position and including disconnecting & taking down the existing unserviceable water tank complete all as specified and directed.
M&L for thermostate suitable for capacity 2 KW to 3 KW as per existing sample complete all as specified and directed .
S&F in replacement of Solar Water heating tank upto capacity 300 Ltr/500 Ltr made up of stainless steel food grade type model No. SS-304-2B as per existing complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
S&F in replacement gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 25mm bore pipe line complete all as specified and directed.
S&F in replacement gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 20mm bore pipe line complete all as specified and directed.
S&F in replacement gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 15mm bore pipe line complete all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified. Note: PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Taking down of storage type electric water heater (Geyser) of storage capacity 25/35/50 Ltrs any make and type for repair tasks at different locations and refixing the same after repair all as specified and directed.
S&F in replacement of three pin plug top 15 Amp suitable for Geyser complete all as specified and directed.
S&F in repair safety valve/ high pressure valve ISI marked all as specified and directed. Make :- Toshiba/ Havells/ Venus/ Godrej
S&F in repair heating element suitable for water storage heater (Geyser) of capacity 25/35 Ltrs cpacity as per existing make and model of ISI mark including making all connections all as specified and directed & as per sample.
Comprehensive Annual maintenance of Storage type Electric, Water Heater (Geyser) of storage capacity 25/ 35/50 Ltrs comprising of the following work at different locations of any make all as specified and directed:- (a) Inspection, taking down , opening (dismantling), brushing, cleaning of storage tank and painting internally with one coat of proprietery bituminous composition not liable to impart test or otherwise contaminate the water. (b) Examining water tightness of storage tank after cleaning. (c) Carryout operation of all stock cocks, pressure reducing valves etc to ensure free movement of the working parts. (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/ vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check maintain and refitting the thermostat and test its functioning. (h) Checking and adjustment of pressure reducing valves. (j) Checking of dead weight type high pressure release valves (PRV) by removing dead weight protection , cleaning the seat and ensuring that the vest hole is not blocked/ choked. (k) Visual examination of fusible plug to ensure its intactness. (l) Descaling of immersion type heating element and cleaning with diluted hydrochloric acid or clear pedette. (m) Replacement/ Repair of neon lamp/ indicator lamp. (n) Testing of Geyser after repairs.
S&F in repair heating element suitable for water storage heater (Geyser) of capacity 50 Ltrs cpacity as per existing make and model of ISI mark including making all connections all as specified and directed & as per sample.
S&F in repair Appratus plate suitable for water storage heater (Geyser) of capacity 25/35 Ltrs cpacity as per existing make and model of ISI mark including making all connections all as specified and directed. Make :- Toshiba/ Havells/ Venus/ Godrej
S&F in repair Appratus plate suitable for water storage heater (Geyser) of capacity 50 Ltrs cpacity as per existing make and model of ISI mark including making all connections all as specified and directed. Make :- Toshiba/ Havells/ Venus/ Godrej
S&F in repair PVC connection pipes inlet and outlet (for hot and cold connection) with brass hexagonal adapters both side, suitable for 15mm dia pipe 45cm long complete all as specified and directed.
S&F in repair CP connection pipes inlet and outlet ( for hot and cold connection) with brass hexagonal adapters both side, suitable for 15mm dia pipe 45cm long complete all as specified and directed.
S&F in repair, Non return valve 15/ 20 mm dia made of brass, ISI marked complete all as specifie and directed.
M&L in repair insulation material (Glass wool) for Geysers complete all as specified and directed.
S&F in repair Water Storage tank of existing Geyser with copper tank suitable for water Storage type Geyser of capacity 25/35 Ltr as per existing make and model all as specified and directed.
S&F in repair Water Storage tank of existing Geyser with copper tank suitable for water Storage type Geyser of capacity 50Ltr as per existing make and model all as specified and directed.
S&F in replacement of capacity 20 Amp, metal clad box with top plug and socket, including 20 Amp, MCB SPN complete all as specified and directed by Engr-in-Charge. Make Siemens Cat Part No. 8GB0501RC and equivalent Havells.
S&F in repair 15mm dia stop cock, cast copper alloy chromium plated, screwed down high pressure with capstoan head screwed both ends for iron pipe or union all as specified and directed.
M&L for refixing loose Geysers of any capacity to walls by regrouting of bolts and refixing the Geysers complete with all necessary pipe connection sand making good the disturbed wall surface all as specified and directed.
M&L for Sub main wiring with 2x6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit and including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
M&L for Sub main wiring with 2x4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 20mm dia PVC conduit and including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 20mm dia PVC conduit shall be measured & paid as one unit.
M&L for Sub main wiring with 2x2.50 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 20mm dia PVC conduit and including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 2.50 sqmm cable and one run of 2.50 sqmm cable as earth wire continuity conductor and one run 20mm dia PVC conduit shall be measured & paid as one unit.
M&L for point wiring for one light point controlled by one way 5/6 Amp switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including providing new 3mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified and directed. Note: (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. Machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 44.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 44.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board.
All as per serial item No. 44.00 here-in-before but for one 3 Pine, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board.
All as per serial item No. 44.00 here-in-before but for One bell point controlled by one bell push.
M&L for point wiring for one switch controlled by one way 15/16 Amp socket outlet with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 2.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly complete all as specified and directed.
M&L for point wiring for one light point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators and including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 50.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 50.00 here-in-before but for One bell point controlled by one bell push.
All as per serial item No. 50.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board.
All as per serial item No. 50.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board.
All as per serial item No. 50.00 here-in-before but for one light point controlled by two, two way switches.
M&L for point wiring for one light point controlled by one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators and including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts (ISI Marked).
S&F in replacement of switch piano, flush type, single pole, one way, 15 Amp, 230 Volts (ISI Marked).
Supply and fixing switch in replacement of piano, flush type, single pole, two way, 5/6 Amp (ISI Marked), 230 Volts.
Supply and fixing in replacement of bell push, flush type, single pole, 5 Amp, (ISI Marked) 230 Volts.
Supply and fixing Bell Multi Music Type, AC, 230 Volts, single pole, (ISI Marked).
S&F in replacement socket outlet 2 in 1, 3 pin, 15 Amps flush type, (ISI Marked), 240 Volts.
Supply and fixing in replacement of socket outlet, 2 in 1, 3 pin, 5/6 Amp, flush type, (ISI Marked), 240 Volts.
Supply and fixing in replacement of stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts including taking down unserviceable complete all as specified.
Supply and fixing in replacement of ceiling rose surface bakelite 65mmx17.5mm with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified.
S&F in replacement of Modular switch 6 Amps, 250 Volt, AC, one way, one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 00 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular switch 16/20 Amps, 250 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5720 63 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 70 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular Socket shuttered, 6/16 Amps, 250 volts, 3 Pin combined, Single Pole, Indian two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 71 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of modular fan step regulator, 120 Watts - 2 module, flush type and connecting up, ISI marked, 240 Volts complete all as specified and directed.
Supply and fixing Modular Metal flush mounting box of 1/2 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 07 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of Modular Metal flush mounting box of 3 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 08 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of Modular Metal flush mounting box of 4 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 09 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of Modular Metal flush mounting box of 6 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 10 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of Modular Metal flush mounting box of 8 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 42 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing in replacement of Modular Metal flush mounting box of 12/16 Module complete all as specified. Make : Legrand (Arteor) Cat Part No 6890 11 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour modular blanking plate, one module blank complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 5736 49 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 1 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 00 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 2 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 10 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 3 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 20 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 4 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 30 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 6 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 40 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 8 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 50 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of white colour plates with frame for modular switch of 2x6 module complete all as specified. Make : Legrand (Arteor) Cat Part No 5757 70 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F 10 watt, LED bulk head fitting in engineering plastic housing with clear prismatic diffuser and interior and exterior applications within car parks, walkways, staricwells, corrriors with all accessories with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceable bulk head complete all as specified and directed. Make : Crompton Greaves Cat Part No LBHP-10-CDL or equivalent in C&S/Philips/Bajaj.
S&F in replacement surface and wall mounted LED tube light fittings of capacity 9 watt, basic all purpose decorative ultra slim round profile LED fighting fixture with extruded polycarbonate environmental friendly, energy efficient ready complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No. LHEXBLP7IN1W009 or equivallent in Philips/CG
S&F in replacement surface and wall mounted LED tube light fittings of capacity 18 watt, basic all purpose decorative ultra slim square profile LED fighting fixture with extruded polycarbonate environmental friendly, energy efficient ready complete all as specified and directed by Engineer-in-Charge. Make:Havells Cat Part No. LHEXBTP7IN1W018 or equivallent in Philips/CG
S&F in replacement surface and wall mounted LED tube light fittings of capacity 20 watt, basic all purpose decorative ultra slim square profile LED fighting fixture with extruded polycarbonate environmental friendly, energy efficient ready complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No. LHEXBTP7IN1W020 or equivallent in Philips/CG
S&F in replacement LED ADORE 10 watt E27 CDL 3 Star rating Lamp LED Bulb. Make : Havells Cat Part No. LHLDEUHEML8R010 complete all as specified.
S&F in replacement LED ADORE 15 watt E27 WW 3 Star Ball Lamp LED Bulb. Make : Havells Cat Part No. LHLDDEHEMC8R015 complete all as specified.
S&F in replacement of lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fiitting complete all as specified.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 4 way, SPN DB, suitable for fixing MCB as outgoing and MCCB Four Pole, rupturing capacity 16 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 8 way (2+6 way), SPN DB, suitable for fixing MCB as outgoing and MCCB Four Pole, rupturing capacity 16 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 12 way (2+10 way), SPN DB, suitable for fixing MCB as outgoing and MCCB Four Pole, rupturing capacity 16 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 415 Volts, 4 way, TPN DB, suitable for fixing MCB as outgoing and MCCB Four Pole, rupturing capacity 16 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 13 or equivalent.
S&F MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 15 or equivalent.
S&F MCCB, 4 Pole, 160 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed. Make : Legrand Cat Part No. 4200 17 or equivalent.
S&F in replacement flameproof Fluorescent luminaire, tube light fitting, flameproof type T8 1x16 LED watt including integral reflector made of aluminium alloy expoy finish LM6 aluminium housing with heat resistant tubular glass cover held in two, with built-in control gear accessories with electronic ballast, bipin holders, connector block, etc and all accessorie pre-wired and incuding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : Crompton Greaves Cat Part No. EXTN1LT8-16/20 or equivalent.
S&F 36 watt 2'x2' LED Panel-595x595mm, Cygnus Series Recess Mounting LED Slim Ceiling light with white powder coated extruded aluminium housing and milky diffuser including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 and including taking down old unserviceable fittings complete all as specified and directed. Make : C&S Cat Part No LTCRSLM36WATT2x2 or equivalent in philips/Havells/CG/Bajaj.
S&F in replacement single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240 Volt, 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed by Engr-in-Charge. Make : HPL Cat Part No SPPC131000000200C00 or equivalent in Neptune
S&F in replacement and connecting LED flood light on building /high mast poles etc aesthetically design fittings pressue die cast housing with IP 65 protection system efficacy ≥ 110LPW option for 3000 K, 10KV SPD included, high output emitter LED for better thermal management of capacity 120 Watt (3000K CCT). Make : Cat Part No. LFLN-120-CDL/60-M of crompton greaves or equivallent in Orient/Wipro.
S&F in replacement and connecting 45 watt LED flood light fitting on high mast poles made up of pressue die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 65 protection system efficacy ≥ 110LM/W option, External SPD included complete all as specified and directed. Make : Cat Part No. LSTP-145-CDL-M of crompton greaves or equivallent in Orient/Wipro.
Supply, install, testing and commissioning of LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.60 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50 Hz double door with front openable and PVC acrylic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN)including bottom gland plate with sufficient numbers of circular cable entry holes, including prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :-
INCOMING :- (i) MCCB 63 Amps 4 Pole, 415 Volt, repturing capacity 25 kA, adjustable thermal & fixed magnetic setting Ics = 100% = 01 No of Make : Legrand Cat Part No. 4200 53 or equivalent Siemens/Havells/C&S electric/. (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/Off indicating lamp on incomer feeder for status of feeder = 2 Nos (iii) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc - 04 Nos. OUT GOING (i) MCB 32 Amp, 240 Volt, 10 kA, Single pole with neutral - 04 Nos, Make : Legrand Cat Part No. 4086 17 or equivalent Siemens/Schnedier (ii) S&F single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed by Engr-in-Charge. Make : HPL Cat Part No. SPPC131000000C00 or equivalent in Neptune - 04 Nos
S&F in replacement of switch flame proof rotary type with termination box in LM-6, 6/16 Amps rating, Single Pole, 240 volt, AC supply, 50 Hz, complete all as specified and directed.
S.D. And Company
M/s Ramesh & Company
star electricals
M/S PRASHANT BENIWAL
M/S JAGDAMBA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .