Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹21.6 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹21.7 L+₹9,930 (0.46%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | ₹21.7 L+₹9,930 (0.46%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹22.3 L+₹65,653 (3.03%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | ₹22.3 L+₹65,653 (3.03%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹22.8 L+₹1.2 L (5.46%)Rejected-Finance | ₹22.8 L+₹1.2 L (5.46%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹23.3 L+₹1.7 L (7.77%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | ₹23.3 L+₹1.7 L (7.77%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Dec 2021, 6:00 pmClosed
GE(AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF SUMMER APPLIENCES, ELECTRICAL WIRING, EXTERNAL ELECTRIFICATION AND ALLIED WORKS AT ALG PASIGHAT STN UNDER GE(AF) CHABUA
2021_MES_478400_2
345/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(AF) CHABUA
₹40,000
Yes
27 Dec 2021
29 Nov 2021
15 Dec 2021
29 Nov 2021
13 Dec 2021
6 Dec 2021
29 Nov 2021 - 4 Dec 2021
Amount
SCH 'A' PART-I
Taking down geyser of any capacity from wall mountings after disconnecting electrical and water connections to carry out repairs. Refixing of geyser of any capacity to wall mountings and making elect and water connections, testing and commissioning complete all as specified and directed. Note:- (i) Spare parts will be measured and paid separately under resp items. (ii) Spare parts shall be of OEM or equivalent approved make.
Taking out complete internal assy i.e. inner tank, inlet and outlet assy, heating element, thermostat etc, of geyser of capacity 25 litres, de-scaling the geyser inner tank using appropriate chemical (descaling agent), cleaning and washing complete accessories, reassembling the same complete all as specified and directed.
Repair to Almn/steel inner container of geyser of 25 ltr capacity by necessary welding/brazing to check the water leakage, testing by applying specified air pressure to ensure leak proof, reassembling of compete geyser complete all as specified and directed.
Supply and fix in repair of apparatus plate assembly of brass suitable for 25 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostat, thermal cut out complete all as specified and directed. Note:- Cost of drilling work, fixing accessories like nuts, bolt, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
Supply only thermostate switch for geyser 25 ltrs capacity complete all as specified and as directed.
Supply only heating element 1.5 KW, A/C 230 Volts (Cup/Triangular Type), complete all as specified and directed.
Supply only heating element 2 KW, A/C 230 Volts (Cup/Triangular Type), complete all as specified and directed.
Supply only safety valve/fusible plug(brass) 15 mm bore for geyser complete all as specified and directed.
Supply only (Neon) Indicator lamp (red/green) round/rectangular type for geyser, all as specified and as directed.
S & F only PVC heavy duty hot and cold water pipe 450mm long fixed both side with brass ferrule nuts for 25/50 ltrs capacity geysers for inlet/out let pipe complete all as specified and as directed.
Materials and labour for rewinding of ceiling Fan complete upto 1400 mm sweep with heavy duty super enamelled copper winding wire of existing gauge including all insulation materials, varnishing, heating, greasing etc. cutting and removing the old burnt winding complete all as specified and as directed. Note:- replacement of unserviceable parts like capacitor, bearing, bush, hanging clamp, reel & nut bolt etc measured and paid separately.
All as per item no-11 here in before but Exhaust Fan upto 300 mm sweep complete all as specified and as directed by engineer in charge.
All as per item no-11 here in before but Exhaust Fan 380 mm sweep complete all as specified and as directed by engineer in charge.
Supply only Ball bearing for ceiling Fan No 6200 complete all as specified and as directed
Supply only Ball bearing for ceiling Fan No 6201 complete all as specified and as directed
Supply only Ball bearing No 6206 for exhaust Fan upto 450mm sweep complete all as specified and as directed.
Supply only Gun metal bush suitable for upto1400 mm sweep ceiling Fan, complete all as specified and as directed.
Supply only Rubber insulator (reel type) complete all as specified and as directed.
Supply only Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed.
Supply only Fan capacitor of capacity 3.5 mfd epoxy filled type complete all as specified and as directed.
Disconnecting from socket out lets split type/window AC of capacity upto 2 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stabilizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed. Note:- Spare parts shall be measured and paid separately under relevant items.
Disconnecting from socket out lets cassette type split AC of capacity upto 3 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stabilizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed. Note:- Spare parts shall be measured & paid separately under relevant items.
Dismantling of old unserviceable compressor from split type AC 2 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from split type AC 1.5 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from split type AC 3 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from water cooler 40/80 ltr capacity. supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Supply only split out door fins type aluminium condensor of capacity 2 Ton, complete all as specified and as directed.
Supply only Starting capacitor 80/100 mfd, complete all as specified and as directed.
Supply only Running capacitor 36 mfd, complete all as specified and as directed.
Supply only Running capacitor 45/50 mfd + 06 mfd, complete all as specified and as directed.
Supply only Starting relay complete all as specified and as directed.
Supply only Contactor relay for split type AC complete all as specified and as directed.
Supply only blower Fan (PVC) for split type AC upto 2 Ton Capacity, complete all as specified and as directed.
Supply only inner Blower Fan for window AC 1.5 ton complete all as specified and as directed.
Supply only indoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only outdoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only Swing motor of lower shutter complete all as specified and as directed .
Supply and charging of refrigerant R-22/307 complete all as specified and as directed.
Supply and fix in repairs PCB Board for split type AC upto 2 ton complete all as specified and as directed.
Taking down carefully u/s indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 Ton complete all as specified and as directed.
Supply & fix in repairs remote control for split/window AC complete all as specified and directed.
Taking out voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing/replacement of push on switch, relay transistor, diode, voltmeter, indicator lamp, high low cutout, MCB, complete parts along with testing and commissioning and transportation charges from site to workshop complete all as specified and as directed by engineer in charge.
Taking out servo voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 7.5 KVA capacity including repairing/replacement of push on switch, relay transistor, diode, voltmeter, indicator lamp, high low cutout, MCB, complete parts along with testing and commissioning and transportation charges from site to workshop complete all as specified and as directed by engineer in charge.
Supply and replacing cooling coil of Refrigerator capacity 280/310 ltr complete all as specified and directed.
Supply and replacing Thermostatic switch of Refrigerator capacity upto 210/310 ltr complete all as specified and directed.
Supply and replacing starting relay of Refrigerator capacity 280/310 ltr complete all as specified and directed.
Supply and replacing starting relay of deep freezer capacity 120 ltr complete all as specified and directed.
Supply and replacing over load relay of Refrigerator capacity 210/230 ltr complete all as specified and directed.
Supply and replacing over load relay of water cooler capacity 40/80 ltr complete all as specified and directed.
Supply & fixing in repairs water cooler tap complete all as specified and directed.
Supply and fix in repairs brass service valve 1/2" dia complete all as specified and directed.
Supply and fix in repairs brass service valve 1/4" dia complete all as specified and directed.
Supply and fix in repairs copper pipe 1/2" dia complete for split ACs including taking down the old one complete all as specified and directed.
Supply and fix in repairs copper pipe 1/4" dia complete for split ACs including taking down the old one complete all as specified and directed.
Supply and fixing, in repairs factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket etc complete, all as specified and directed.
Disconnecting out door type split unit of 1.5/2 TR capacity and refixing the same with supply and fixing new mounting bracket made out of 50 x 50 x 6 mm thick angle iron frame including PCC and masonary work, reconnecting the copper pipe with new insulation to the indoor and out door unit and testing on completion complete all as specified and directed.
S & F in repairs, insulation tube (size 1/4"/1/2") for split type AC to insulation copper pipe complete all as specified and directed.
Taking down carefully aluminum/copper point wiring for light, bell, fan, socket outlet, complete in all respect including fittings such as wooden battens junction boxes, round blocks Bakelite sheets, and making good to the disturbed surface of wall, ceiling or floor etc to match with the existing specifications complete all as specified and directed.
Taking down existing DB TPN/SPN any type of any capacity including MCBs and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down existing serviceable light fittings any type of any capacity removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M&L for Point wiring with approved colour coding as per IS with multistranded copper conductor 1.5 Sq mm (nominal area), single core, flame retardant low smoke (FRLS), PVC insulated and un sheathed cable 1100 Volts grade, ISI 694 marked TEC and FIA approved in and including PVC concealed conduit medium grade, suitable for light/bell/fan point terminated in and including mild steel terminal boxes covered with new 3 mm thick plastic laminated sheet and controlled by one switch including flame retardant low smoke (FRLS) PVC insulated un sheathed multistranded copper conductor 1.5 Sq mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed. Note:-The cost of making good to the disturbed surfaces to match with the adjacent surfaces shall be deemed to be included in the quoted rate.
All as per srl item No 61 here in before but for multi pin socket outlet 5 Amps multi purpose on the same board with other switches including continuous earth wire PVC insulated, unsheathed, single core multi stranded copper conductor cable 1.5 Sqmm & connected to earth dolly complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
All as per srl item No 61 here in before for multipin socket outlet 5 Amps multi purpose on independent board using 2.5 sqmm and 1.5 sqmm multitranded copper conductor cable for wiring and earth continuity conductor respectively complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
All as per srl item No 61 here in before for multipin socket outlet 15 Amps multi purpose on independent board using 4.0 sqmm and 2.5 sqmm multistranded copper conductor cable for wiring and earth continuity conductor respectively complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
All as per item No 61 above but one light point controlled by 2 way switches with 1.5 sqmm size complete all as specified and directed.
M&L for Point wiring with approved colour coding as per IS with multistranded copper conductor 1.5 Sq mm (nominal area), single core, flame retardant low smoke (FRLS), PVC insulated and un sheathed cable 1100 Volts grade, ISI 694 marked TEC and FIA approved in and including PVC casing capping medium grade, suitable for light/bell/fan point terminated in and including mild steel terminal boxes covered with new 3 mm thick plastic laminated sheet and controlled by one switch including flame retardant low smoke (FRLS) PVC insulated un sheathed multistranded copper conductor 1.5 Sq mm (nominal area)single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed. Note:- The cost of making good to the disturbed surfaces to match with the adjacent surfaces shall be deemed to be included in the quoted rate.
All as per srl item No 66 here in before but for multipin socket outlet 5 Amps multi purpose on the same board with other switches including continuous earth wire PVC insulated, unsheathed, single core multi stranded copper conductor cable 1.5 Sqmm & connected to earth dolly complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
All as per srl item No 66 here in before for multipin socket outlet 5 Amps multi purpose on independent board using 2.5 sqmm and 1.5 sqmm multistranded copper conductor cable for wiring and earth continuity conductor respectively complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
All as per srl item No 66 here in before for multipin socket outlet 15 Amps multi purpose on independent board using 4.0 sqmm and 2.5 sqmm multistranded copper conductor cable for wiring and earth continuity conductor respectively complete all as specified and directed. Note:- Switch and socket to be measured and paid for separately.
S & F sub main wiring with two single core 6.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS), including two run of continuous PVC insulated FRLS copper stranded cable of size 4.0 Sqmm for earth continuity in and including surface/recessed/concealed, heavy duty PVC conduit, including dismantling & taking down existing wire with accessories, complete all as specified and directed. Note:- 2 runs of 6.0 Sq.mm main cable+1 run of 4.0 Sqmm earth cable+PVC conduit considered as 1 Running Metre.
S & F sub main wiring with two single core 4.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS), including two run of continuous PVC insulated FRLS copper stranded cable of size 1.5 Sq.mm for earth continuity in and including surface/recessed/concealed, heavy duty PVC conduit, including dismantling & taking down existing wire with accessories, complete all as specified and directed. Note:- 2 runs of 4.0 Sq.mm main cable+1 run of 1.5 Sq.mm earth cable+PVC conduit considered as 1 Running Metre.
S & F sub main wiring with four single core 10.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS) , including two run of continuous PVC insulated FRLS copper stranded cable of size 4.0 Sq.mm for earth continuity in and including surface/ recessed / concealed ,heavy duty PVC conduit, including dismantling & taking down existing wire with accessories, complete all as specified and directed. Notes:- 4 runs of 10.0 Sq.mm main cable+2 run of 6.0 Sq.mm earth cable+PVC conduit considered and as 1 Running Metre.
Supply and fixing in repair of switch piano type, flush type, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fixing of in repair, switch piano type, flush type, single pole, one way, 15 Amps, complete all as specified and directed.
Supply and fixing in repair of socket outlet flush type multipins, 5 Amps multipurpose, complete all as specified and directed.
Supply and fixing in repair of socket outlet, flush type, multi purpose multipin, 5 Amps & 15 Amps, 230 volts, complete all as specified and directed.
Supply and fixing in repair of switch bell push flush type 05 Amps (230 volts), complete all as specified and directed.
Supply and fix, in replacement of bell, single phase 230 volts, AC, 50 Hz (domestic pattern), complete, all as specified and directed.
Supply and fix, in replacement of ceiling fan regulators step type electronic for 1200/1400 mm sweep ceiling fan and connecting up complete with provision of PVC flexible cable size 1.5 Sqmm twin core copper conductor, complete, all as specified and directed.
Supply and fix, in replacement of ceiling rose surface bakelite 65 x 50 mm, two to three terminals, complete all as specified and directed.
Supply and fix in repairs lamp holder, PVC/poly carbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing, LED Decorative batten fitting 1x18 to 22 W, prewired suitable for retrofit LED tubes, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sqmm from ceiling rose to connector block, including taking down old unserviceable surface mounted fitting of any wattage and type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube), energy saving, recess/surface mounted luminaire suitable for fix in the batten fitting 1x18W to 22W complete all as specified and directed.
Supply and fix in repairs recess mounting LED slim ceiling light fitting extruded aluminium housing and milky diffuser suitable for 2' x 2' ceiling cell of 36 watt complete all as specified and directed.
Supply and fix in repairs recess mounting LED slim ceiling light fitting extruded aluminium housing and milky diffuser suitable for 1' x 1' ceiling cell of 18 watt complete all as specified and directed.
Supply and fix in repair integral polycarbonate LED PL-L rod with 2G11 lamp holder of capacity upto 18 watts complete all as specified and directed.
Supply and fix in repair integral polycarbonate LED rod with 2 pin two sided lamp holder of capacity upto 9 watts complete all as specified and directed.
Supply and fix in repair integral polycarbonate LED channel with white acrylic cover of capacity 10 watts complete all as specified and directed.
S&F in repairs Sheet metal distribution board double door, vertical type VTPN suitable for mounting of MCB 4 pole as incoming and MCBs as outgoing, including earth dolly made of CRCA sheet of thickness 1.6 mm with IP- 43 protection, 4 ways, 415 volt, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Sheet metal distribution board double door, vertical type VTPN suitable for mounting of MCB 4 pole as incoming and MCBs as outgoing, including earth dolly made of CRCA sheet of thickness 1.6 mm with IP- 43 protection, 8 ways, 415 volt, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, in repairs MCBs Distribution board, sheet metal enclosure, SPN 240 Volts, 08 ways with 200 amps rated bus bar, double door for MCBs, with IP 43 protection, complete all as specified and directed.
Supply and fixing, in repairs MCBs Distribution board , sheet metal enclosure, SPN 240 Volts, 12 ways with 200 amps rated bus bar, double door for MCBs, with IP 43 protection, complete all as specified and directed.
Supply and fixing, in repairs MCBs, SP, 240 Volts, 5 Amps to 40 Amps, C curve, 10 kA, complete all as specified and directed.
Supply and fixing, in repairs MCBs , SPN , 240 Volts , 5 to 40 Amps , C curve , 10 kA , complete all as specified and directed.
Supply and fixing, in repairs MCBs, TPN ,415 Volts, 40 Amps , C curve , 10 kA , complete all as specified and directed.
Supply and fixing, in repairs MCBs, TPN ,415 Volts, 63 Amps , C curve , 10 kA , complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3, including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funneland wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion including taking down old unserviceable earthing complete all as specified and directed. Note:- Main earth lead beyond 7.5 meter shall be measured and paid separately.
Material & Labor for servicing/maintenance of Fire alarm control Panel (FACP), 32 bit microprocessor based intelligent adversable fire alarm control system with single loop with battery backup (2x24)Hrs, 17 AH SMC battery ones in three months all as specified and directed.
Dismantling, Servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed every six month complete all as specified and directed.
Supply and Fixing in repair or replacement of Indoor addressable detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric/optical with base with self built intelligence all as specified and as directed.
SCH 'A' PART-II
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 25 Sqmm nominal cross section x 3.5 core including taking down old unsv cable complete all as specified and as directed.
All as per item No 101 above but Size 35 Sqmm X 3.5 core complete all as specified and as directed.
All as per item No 101 above but Size 95 Sqmm X 3.5 core complete all as specified and as directed.
Supply and laying in trenches/through pipes under road, floor/on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm including taking down old unsv cable complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers including taking down old unsv covers complete all as specified and as directed.
Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
S&F Sub-Class B Brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Supply and fixing in repairs steel tubes, galvanized, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete all as specified and as directed.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreting with PCC 1:3:6 to match with the adjacent surfaces complete all as directed.
S & F in repairs MCCB 4 pole, 415 volt 100 Amps with breaking capacity 16 kA, adjustable type 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 125 Amps with breaking capacity 36 kA, adjustable type 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 250 Amps with breaking capacity 36 kA, adjustable type 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 400 Amps with breaking capacity 36 kA, adjustable type 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 630 Amps with breaking capacity 50 kA, adjustable type 415 V, 50 Hz, all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x60 cm x6 mm thick burried directly in ground (earth pit not less than 2.5 mtr below normal ground level ) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to main earth lead GI strip 32x 6mm as earth lead by means of bolts ,nuts, checknuts and washers of galvanized iron or steel as shown in electrical plate No. 3, including exc , and earth work in any type of soil disposal of soil providing alternate layers of charcoal and common salt construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick 1:2:4 type B-1 cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement. Note : Main earth lead beyond 7.5 meter shall be measured and paid separately. Note:- Taking down old unserviceable dilapidated chemical earthing are included in quoted rate.
M&L in repair for Air break Switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11000 volts complete all as specified and directed.
M & L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of copper and copper strip of size 25 x 3 mm & strip connection on the top of the electrode and copper strip of size 25 x 3 mm for inter connection of 03 nos copper bonded rods and laying at least 500 mm below in the ground and further connected to test point terminal block (copper strip and test terminal block shall be measured separately), including back filling of bore holes with advanced earth enhancing compound 96 kilogram (minimum) of Make : Erico or equivalent of Macmet/True Power/Ennov for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as directed and including necessary earth work and testing complete all as specified and directed. Note:- Taking down old unserviceable delapidated chemical earthing are included in quoted rate.
M&L for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level copper earth lead strip 20 x 3mm size by mean of nut/bolt and washer of copper as shown in electrical plate no 3 of SSR part I including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnelled wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed at site. Note:- (i) Main earth lead beyond 7.5 meter shall be measured and paid separately. (ii) Taking down old unserviceable delapidated copper earthing are included in quoted rate.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Taking down HT switch gear (Vacuum circuit breaker SF 6) of capacity 11 KV comprising of following repairs, overhauling, servicing and refixing the same after repairs/overhauling:- (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley/SF6 for servicing/inspection/overhauling (b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. (c) Servicing/Inspecting/checking of circuit spout and circuit spout connections for RYB phases and replacement of spares if required. (d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f) Servicing/Inspecting/checking of secondary sockets/bus bar earthing plugs/earthing sockets and replacement of spares if required.
S & F in repair protection Relay CSDPR-V2 suitable for 11 KV HT panel SF 6 complete all as specified and directed.
Cleaning, desludging and removing of all scales and dirt from OH Pressed Steel Tank of capacity 9600 gallons installed at height of 40' staging and write (size of lettering 75 mm height) on indicated space at a height 3.5 mtr from ground level(ie. DATE OF CLEANING................, CAPACITY OF TANK ..................etc.) in black synthetic paint over white synthetic enamel paint all as directed and specified. Note:- (a) Cost of staging/working platform involved shall be deemed to be included in the unit rate quoted. (b) consumption of bleaching powder for cleaning of each tank shall not be less than 12 Kg (c) Maximum two times cleaning of each tank in entire C.A. period (Measured separately each time).
Labour only for cleaning of under ground sump of capacity 40KL, including removal/taking out of sludge, cleaning of side wall by jute with necessary bleaching powder, complete all as specified and as directed. Note:- Cost of staging/working platform, bleaching powder involved shall be deemed to be included in the unit rate quoted.
S&F in repairs steel water tubing medium grade galvanized, with all fittings laid in trenches of size 40 mm bore complete all as specified and as directed. Note:- Excavation and earth work if required will be measured and paid separately.
All as per item 133 here-in-before but 80mm bore complete all as specified and as directed.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and as directed.
All as per item 135 but for 25mm bore pipe complete all as specified and as directed.
All as per item 135 but for 40mm bore pipe complete all as specified and as directed.
All as per item 135 but for 80mm bore pipe complete all as specified and as directed.
Supply and fixing in repairs foot valve gun metal ISI marked 80 mm dia complete all as specified and as directed.
Attending emergency breakdown of sewage/water supply installation where directed, taking out defective submersible pump set of capacity 5HP/10HP incl column pipes from bore well, transporting pump set from site to work shop for repairs and back and lowering the pump set incl column pipes and making water and electric connection as per existing for running of pump motors complete all as directed. Note:- (i) Spare Parts shall be measured & paid under relevant items. (ii) Spare parts shall be of OEM or equivalent in approved make.
Supply only Upper housing 80 mm for 5 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Mitchel thrust bearing gunmetal V6 for 05 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
Supply only Rotor for, 05 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Intermediate piece for 5 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
Rewinding of stator of submersible motor for 5 HP capacity with water proof insulated copper wire of existing gauge to achieve the specified/required RPM including taking out old unserviceable winding, complete all as specified and as directed.
Rewinding of stator of induction motor working on AC 440 / 230 volts for Centrifugal/monoblock pump set of 5 HP capacity with copper wire winding of appropriate existing gauge including taking out old unserviceable winding complete all as specified and as directed.
S&F in repairs Fully Automatic Star Delta Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (9-14 Amps) suitable for 5/10 HP submersible pump, and connection, testing, complete all as specified and as directed.
S&F in repairs DOL Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (7-10 Amps) suitable for 5 HP pump , and connection , testing ,complete all as specified and as directed by Engr-in-charge.
Taking up GI water mains from trenches for repair/rectification of leakage of GI water line of sizes 15 to 25 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed. Note:- Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 40 to 50 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed. Note:- Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Material and labour in repairs Earth continuity conductor or main earthing lead or lightning conductor, 20mmx3mm copper strip, fixed to wall on batten with saddles and fixing screws, PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including dismantling and removing existing old copper strip, complete all as specified and directed.
S & F in repairs power factor improvement static condenser (capacitors) of required capacity, complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO 01 NC complete all as directed.
S & F in repairs APFC Relays with auto set function having steps 6 stage suitable for 415 Volts incl necessary connections all as directed.
S & F in repairs electronic protection Relays overload, single phasing, current unbalance, under current complete all as specified and directed.
Schedule of Credit
M/S RK Trading
M/S Abhi Traders
Prova Stores
M/s Pramillabh Construction
M/S R & R D ENTERPRISES
M/s Lalowari Electricals
M/S Dee Dee Singhania & Sons
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .