| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹82.1 L+₹7.6 L (10.2%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹82.9 L+₹8.4 L (11.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹84.3 L+₹9.8 L (13.1%)Rejected-Finance VILLAGE PO RAJAIN TEHSIL BHATTIYAT DISTT CHAMBA HP | L4 | Rejected-Finance L4 | |
| 5 | L5₹88.7 L+₹14.2 L (19.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹73.5 L
EMD Value
₹1.1 L
Closing Date
27 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division Jubbal
Providing LWSS to PC Hab of CV Ghunda Jabrog CHatoli Koti etc in GP Himri and Ghunda Tehsil Kotkhai Distt Shimla HP
2022_HPIPH_60722_1
JBL-SML-09-718
Open Tender
Civil Works
Item Rate
365 days
Gumma
Please refer Tender documents.
9 documents required · 9 mandatory
₹800
₹1.1 L
Yes
5 Sept 2022
17 May 2022
27 May 2022
17 May 2022
27 May 2022
17 May 2022
120 days
Amount
Excavation in foundation for digging well in dry excavation from ground level upto the level where well curb is placed including dispositing spoils in 20 mtrs radius and filling space outside the well after complation(pick work in all kinds of soil with in all leads & lifts and disposing of surplus soil excavatd earth with in all leads and lifts as per the direcion of Engineer-in-Charge
Wet well sinking in gravel including all pumping shoring etc, within all leads and lifts.
From sumping level to 3 mtrs.
From sumping level from 3 Mtr to 6 mtrs.
From sumping level from 6 Mtr to 9 mtrs.
From sumping level from 9 Mtr to 12 mtrs.
Steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in R.S. Joists,channels, angles, tees etc. with in all leads and lifts as directed by the Engineer Incharge
Lowering of well curb with in all leads and lifts as directed by the Engineer Incharge
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Columns, Pillers, Posts with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing and laying (porus) No fine cincrete 1:4 (1 cement: 4 graded stone agg. 40mm) and above and curing complete with weep holes or porus etc. with in all leads & lifts as per the entire satisfaction & direction of the Engineer Incharge.
Providing from work of steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooden battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for insitu reinforced concrete and plain concrete work with in all leads and lifts as per the direction of the Engineer-in-charge in -
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like with in all leads and lifts as per the direction of the Engineer - in - Charge.
Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness with in all leads and lifts as per the direction of the Engineer - in - Charge.
Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth.
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Column, pillar & post upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Beams, cantilever Girders& lintals sides&soffits of beams, beams,haunching cantilever girders not exceeding 1mtr. Depth.
Slopping and battering surfaces I/c folding plates where inclination to horizontal plane not exceeding 30 degrees.
Edge of slab and break in floor 20 cm wide
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces with in all leads and lifts as per the direction of the Engineer in Charge.
Providing mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Square rubble masonry with approved quality including racking out of joints in foundation & plinth in cement mortar 1:45 (1 cement : 4 Mortar) above NSL/GL.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:3 (1cement: 3sand) with in all leads and lifts as directed by the Engineer-in-Charge.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded stone aggregate 40mm (Forty millimeter nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per direction of Engineer - in charge.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in CM 1:4 (1cement: 4sand)With in all leads and lifts as per the direction of the Engineer- in- charge.
Providing and Fixing (M.S. Sheet & Angle Iron) 600x600 mm size man hole cover with frame and controling chaber for wheel valve complete in all respects including locking arrangements etc. (not less than 58 Kg) within all leads and lifts and as directed by the Engineer-in-charge.
Providing 200mm wide cast iron rungs with chequered or ribbed non slip surface i/c fixing in manholes with 200x200x100mm cement concrete 1:3:6 (1 cement :3 sand 6graded stone aggregate 20mm nominal size.)
Boulder filling behind R/wall & B/wall within all leads and lifts and as directed by the Engineer-in-charge.
Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts as per the directions of the Engineer in charge.
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Column, pillar & post upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
Profile - A
Profile - B
Profile - C
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 50mm thick: 2nd class deodar wood.
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 40 mm thick 2nd class deodar wood.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
6 mm thick cement plaster in CM 1:3( 1cement 3 sand in roof slabs
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surfaceto give an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other foreigm matter
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts an da directed by the Engineer-in-charge.
Providing and fixing bright finished brass sliding door bolt with nut and screws complete. 250mm x 16mm
Providing and fixing Anodized aluminium tower bolts withnuts and screws complete.
200mm x 10mm
100mm x 10mm
Providing and fixing Anodized aluminium handle withnuts and screws complete.
125 mm dia.
100 mm dia.
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge.
Providing and laying cement concrete 1:1:2 (1cement :1Sand: 2 graded stone aggregate 20 mm N/S) and curing complete excluding cost of form work and reinforcement for Rainforced concrete work in
foundation and plinths complete as per the direction of the Engineer - in - Charge.
Walls (Any thickness) attached pillasters, pillasters, buttresses, beam girder and contilevers upto floor two level with in all leads & lifts as per direction of Engineer - in charge.
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcment for reinforcement concrete work in Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Laying, butt welding and testing of ISI marked steel tubes plain ended in trenches of following dia as per IS 1239-2001, including jointing the pipes with butt welding at both the ends according to relevant BIS standards/approved specifications including manufacturing reducers/tapers, all short pices and bends as per site requirement and made from parent tubes ( to be measurer and paid alongwith pipes. Bends shall be manufactured in such a way that not more than 111/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in-charge. The damaged portion of galvanization due welding shall be provided with anticorrosive treatment by providing two coats of bituminous paint over priming coat as per AWWA specification C-203-1978. (Earth work to be measure & paid for separately).
G.I Pipes 65mm dia (Heavy Class) Wall thickness = 4.50mm.
Providing and welding MS flanges as per table below confirming to IS:6392-1971(up to date ammendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS 814-1967 including required Nos. and size of MS nuts and bolts as per IS: 1369-1967 and compressed asbestos fiber jointless gaskets sheets not less than 3mm thick as per IS:2712-1965.The welding of flanges to be done in three layers ( two out side +one inside) to make the joints leak proof and complete in all respects with in all leads & lifts as per directions of Engineer - in - charge. Dia F. Table.
Pumping Machinery for booster stage. Providing and installation submersible pump make KSB/Kirlosker/ Mather and Platt) confirming to IS 9034-1976 alongwith directly coupled submersible type squirel cage electric induction motor suitable for operation on 415 Volt. 3 phase 50 C.P S.E.A supply water lubricated bearing and provided with pivoted segment type thrust bearing to with stand non vertical lead with minimum wear and tear and dully filled with device to take up to the expension including of water with heating of motor complete in all respects including entire satisfection of Engineer-in-Charge. a) Pump Specifications: 1. Make 2. Model 3. No. of stages 4. Material Manufactures certificate to be appended performances: 1. Total Head = 77.87 Mtr. 2. Discharge = 3.13 LPS. 3. BHP absorbed 4. Efficiency = 60% 5. NPSH. b) Motor: 1. Make 2. Model 3. Motor rating 4. Speed .... RPM. 5. Insulation. (2x7.50 HP)
Supply and fixing of control panel for mono submersible pump complete with shaft and angle iron, febricated duly painted and complete with internal wiring and comprising of air break starter main switch of suitable Amp., T.P volt meter, ameter, phase indicating lamp water level gaurd and single phase preventor including entire satisfection of Engineer-in-Charge.
Supply and fixing submersible cable 2.5 Sqmm to Mono submersible pump including entire carriage and satisfection of Engineer-in-Charge.
Pumping Machinery for 1st. Stage. (Jabrog). Providing horizontal spindle,horizontal/redial split casing/and suction(Back-full out arrangements single/double/multi stage centrifugal pump or combination of pumps. In series/parallel of recommended make such as Mather and Platt/KSB/Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammend-ments read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor/motors of standard make such as Kirlosker/BHEL/Crompton/NGEF/GEC/Siemens/Jyoti and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts bolts and painting etc. and should meet the following requirements. . (2x40 HP)
Duty Conditions: i) Discharge (Q) = 3.13 LPS foe each pump. ii) Total dynamic head 453.09 Mtr. a) LWL in sump well (h) = 1500 Mtr. b) Shaft level = 1500 Mtr. c) Level at discharge point = 1903 Mtr. d) Suction lift (+) head Mtr. e) Discharge head Mtr. f) Static head = 403.00 Mtr. iii) Rising main: a) Length of R/main= 1800 Mtr. b) Dia of R/main = 65mm. iv) Pumping hours = 8 hours. v) Altitude of installation above MSL Mtr. vi) Characterstics of water: clear cold water. a) Temperature 0c. b) Ambient temp 0c. c) Turbidity JTU. d) Alkalinity e) Size of the solids NIL mm. f) Others.
Providing ICTP Main switch with HRC fuses of Kilburn/L&T/siemens/Standard/Havells make and having capacity 30% extra of the operational rating as per IS: 4064:1978 with upto date ammendments immeidately after the power meter of the HPSEB. ICTP Switch Make Type Capacity
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capacable of mounting the following accessories withina ll internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities. Panel Switch Board Drawing Layout plan
ACB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB Make Range Capacity
Earth leakage circuit breaker of recommonded make L&T/MEI/GEC as per IS:2516- 1977 with upto date ammendements and of suitable range which should have control box,operating,handle and trip/reset bush button on/off indicators re-indicating off spring condition of the circuit breaker for over current protection. The cicuit should be equipped with magnet thermal release with matallic tape CST, it should be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and suitable for above motor and the voltage meter relay 3 phase with all protection and usual indicators and electrid siran against single phasing, low voltage,reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition) ELCB Make Type Range
100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/ Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. Volt meter Make Type Range:
Power factor mtr of standard make as per relevent IS code with upto date ammendements. Power Fector Meter Type Make
Frequency mtr of standerd make as per relevent IS code with upto date ammendements. Frequency Meter Make Type Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-with uptodate ammendments.
ICTPswitches with HRC fuses of Kulburn/L&T/Siemens/Standered/Havells make and of suitable capacity as per IS:4064-1978 with up to date ammendments. ICTP Switches Make Capacity
Three phase indicator lamps complete with toggie switches for individual motors as per per IS:3452(P_I&II) with up to date ammendements. Three phase indicator Make Capacity
Capacitor of Mecheil/BHEL/GEC/L&Tmake as per IS2834-1986 with up to date ammendements,to raise the power factorat site to 0.95 for direct connection to induction motor individuaily of required KVA rating according to H.P offered including cables as per relevent ISI code(of Siemens/Ciocter/ IEC make0 from busbar chamber to capacitor and also including ICTP switches of appropriate up date ammendements. Capacitor Make Range
Hours run meter of reputed make.
P/fixing suitable oil immersed Star Delta strarter L&T/Siemensmake as per IS:8544-1979 with up to date ammendements for squirrel cage/ slip ring motor mounted on panel board with magnetic type over load release and dashpot pot, time lag under voltage release with or with out initial oil filling as the case may be with single phase preventer as per IS:1248(P-V)-1983 with up to date ammendements. Single Type: Make:
P/Fixing cast iron flanged/screw type stainer as per IS:4038-1986 with up to date ammendement of Kirlosker/Karter valve Machneil/Kilburn Leader make 65 mm dia. Make: Dia:
Providing/Fixing of Cast iron double flanged sluice valve of class-II 65 mm dia of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on suction side as per the relevant IS code. Sluice valve Make: Class: Dia:
Providing/Fixing of Cast iron double flanged sluice valve of class-II 65 mm dia of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on suction side as per the relevant IS code. Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast steel reflux valve of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and of 65 mm dia having bypass arrangements on the delivery side of the pump and capable of with standing the normal sheet pressure as per IS:5312-1984(P-1) with up to date ammendements class ASA to be mentioned by the firm. Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast steel reflux valve of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and of 65 mm dia having bypass arrangements for rising main and capable of with standing the normal sheet pressure as per IS:5312-1984(P-1) with up to date ammendements class ASA to be mentioned by the firm. Sluice valve Make: Class: Dia:
Provading mm dia circular dial pressure guage of Fiebig/Bourden/PREGA/Precision make complete with all accessories such as stop cock, copper tubing etc.as per IS :3624-1987 with up to date ammendements. Pressure gauge Make: Digital .
Providing and fixing double flanged API pipe work (Layout to be approved by the Engineer -incharge of work for suction and delivery pipe suitable for pump(s) offered and common header as per the R/main respectively complete with all specials such as bends,tees,reducers,increasers with conpanion flanges mating with the relevent spectifications of the accessories as indicated in the drawing no 2 including rubber/asbestos gasket of minium 3mm thickness as per IS:2712-1979 and required no,s of nuts and bolts as per IS1364-1983. the pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1 the size of the various components to be as under:- I)Suction pipe mm dia II)Delivery pipe mm dia III)Common header mm dia and will be extendewd up to 5mtrs from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable (one vable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-I) 1988 or latest with up to date ammend ements of siemens/Gloster/IEC/ICC/ EICO/National/GRANDLY make including all other accessories such as thimbles,flexible pipes, solder,nuts and bolts,vable glands etc. laid in pipes or trenches under floor. Armored power cable Motor side (from switch to starter and starter to motor) Size Make Type Core Supply side(From meter of HPSEB to bus bar Size Make Type Core
Providing and fixing double loop earthing with copper plate 600 mm*600mm*3mm thick electrode complete with material such as thimble,nuts and bolts,charcoal and common salt 25mm*5mm copper strips as per IS:3043_1987 with up to date ammendements for motor and other electrical equipments and digging of pits etc. complete in all respect and as per the direction of Engineer-in-charge.
Pumping Machinery for 2nd. Stage. (Ghunda). Providing horizontal spindle,horizontal/redial split casing/and suction(Back-full out arrangements single/double/multi stage centrifugal pump or combination of pumps. In series/parallel of recommended make such as Mather and Platt/KSB/Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammend-ments read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor/motors of standard make such as Kirlosker/BHEL/Crompton/NGEF/GEC/Siemens/Jyoti and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts bolts and painting etc. and should meet the following requirements. . (2x20 HP)
Duty Conditions: i) Discharge (Q) = 2.36 LPS foe each pump. ii) Total dynamic head 228.00 Mtr. a) LWL in sump well (h) = 1900 Mtr. b) Shaft level = 1900 Mtr. c) Level at discharge point = 2103 Mtr. d) Suction lift (+) head Mtr. e) Discharge head Mtr. f) Static head = 203.00 Mtr. iii) Rising main: a) Length of R/main= 1200 Mtr. b) Dia of R/main = 65mm. iv) Pumping hours = 8 hours. v) Altitude of installation above MSL Mtr. vi) Characterstics of water: clear cold water. a) Temperature 0c. b) Ambient temp 0c. c) Turbidity JTU. d) Alkalinity e) Size of the solids NIL mm. f) Others.
Providing ICTP Main switch with HRC fuses of Kilburn/L&T/siemens/Standard/Havells make and having capacity 30% extra of the operational rating as per IS: 4064:1978 with upto date ammendments immeidately after the power meter of the HPSEB. ICTP Switch Make Type Capacity
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capacable of mounting the following accessories withina ll internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities. Panel Switch Board Drawing Layout plan
ACB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB Make Range Capacity
Earth leakage circuit breaker of recommonded make L&T/MEI/GEC as per IS:2516- 1977 with upto date ammendements and of suitable range which should have control box,operating,handle and trip/reset bush button on/off indicators re-indicating off spring condition of the circuit breaker for over current protection. The cicuit should be equipped with magnet thermal release with matallic tape CST, it should be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and suitable for above motor and the voltage meter relay 3 phase with all protection and usual indicators and electrid siran against single phasing, low voltage,reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition) ELCB Make Type Range
100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/ Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. Volt meter Make Type Range:
Power factor mtr of standard make as per relevent IS code with upto date ammendements. Power Fector Meter Type Make
Frequency mtr of standerd make as per relevent IS code with upto date ammendements. Frequency Meter Make Type Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-with uptodate ammendments.
ICTPswitches with HRC fuses of Kulburn/L&T/Siemens/Standered/Havells make and of suitable capacity as per IS:4064-1978 with up to date ammendments. ICTP Switches Make Capacity
Three phase indicator lamps complete with toggie switches for individual motors as per per IS:3452(P_I&II) with up to date ammendements. Three phase indicator Make Capacity
Capacitor of Mecheil/BHEL/GEC/L&Tmake as per IS2834-1986 with up to date ammendements,to raise the power factorat site to 0.95 for direct connection to induction motor individuaily of required KVA rating according to H.P offered including cables as per relevent ISI code(of Siemens/Ciocter/ IEC make0 from busbar chamber to capacitor and also including ICTP switches of appropriate up date ammendements. Capacitor Make Range
Hours run meter of reputed make.
P/fixing suitable oil immersed Star Delta strarter L&T/Siemensmake as per IS:8544-1979 with up to date ammendements for squirrel cage/ slip ring motor mounted on panel board with magnetic type over load release and dashpot pot, time lag under voltage release with or with out initial oil filling as the case may be with single phase preventer as per IS:1248(P-V)-1983 with up to date ammendements. Single Type: Make:
P/Fixing cast iron flanged/screw type stainer as per IS:4038-1986 with up to date ammendement of Kirlosker/Karter valve Machneil/Kilburn Leader make 65 mm dia. Make: Dia:
Providing/Fixing of Cast iron double flanged sluice valve of class-II 65 mm dia of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on suction side as per the relevant IS code. Sluice valve Make: Class: Dia:
Providing/Fixing of Cast iron double flanged sluice valve of class-II 65 mm dia of Leader/.Bhel Kirlosker/ GIED/ Kilburn/ Fouress make on suction side as per the relevant IS code. Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast steel reflux valve of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and of 65 mm dia having bypass arrangements on the delivery side of the pump and capable of with standing the normal sheet pressure as per IS:5312-1984(P-1) with up to date ammendements class ASA to be mentioned by the firm. Sluice valve Make: Class: Dia:
P/F double flanged Swing type cast steel reflux valve of Leader/BHEL/Kirlosker/ Kilburn/GLED/Kartar valve/Fouress make and of 65 mm dia having bypass arrangements for rising main and capable of with standing the normal sheet pressure as per IS:5312-1984(P-1) with up to date ammendements class ASA to be mentioned by the firm. Sluice valve Make: Class: Dia:
Provading mm dia circular dial pressure guage of Fiebig/Bourden/PREGA/Precision make complete with all accessories such as stop cock, copper tubing etc.as per IS :3624-1987 with up to date ammendements. Pressure gauge Make: Digital .
Providing and fixing double flanged API pipe work (Layout to be approved by the Engineer -incharge of work for suction and delivery pipe suitable for pump(s) offered and common header as per the R/main respectively complete with all specials such as bends,tees,reducers,increasers with conpanion flanges mating with the relevent spectifications of the accessories as indicated in the drawing no 2 including rubber/asbestos gasket of minium 3mm thickness as per IS:2712-1979 and required no,s of nuts and bolts as per IS1364-1983. the pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1 the size of the various components to be as under:- I)Suction pipe mm dia II)Delivery pipe mm dia III)Common header mm dia and will be extendewd up to 5mtrs from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable (one vable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-I) 1988 or latest with up to date ammend ements of siemens/Gloster/IEC/ICC/ EICO/National/GRANDLY make including all other accessories such as thimbles,flexible pipes, solder,nuts and bolts,vable glands etc. laid in pipes or trenches under floor. Armored power cable Motor side (from switch to starter and starter to motor) Size Make Type Core Supply side(From meter of HPSEB to bus bar Size Make Type Core
Providing and fixing double loop earthing with copper plate 600 mm*600mm*3mm thick electrode complete with material such as thimble,nuts and bolts,charcoal and common salt 25mm*5mm copper strips as per IS:3043_1987 with up to date ammendements for motor and other electrical equipments and digging of pits etc. complete in all respect and as per the direction of Engineer-in-charge.
Roshan Chauhan
M/s Pardeep Sublaik
AJAY MEHTA
rupinder justa govt contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .