Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.8 LAccepted-AOC | L-1 | Accepted-AOC Accept | |
| 2 | L-2₹37.9 L+₹10,827.50 (0.29%)Rejected-Finance | L-2 | Rejected-Finance High rates | |
| 3 | L-3₹40.0 L+₹2.2 L (5.88%)Rejected-Finance | L-3 | Rejected-Finance High rates | |
| 4 | L-4₹40.9 L+₹3.2 L (8.37%)Rejected-Finance A SECTOR BHAGWATI BHAVAN VIJAY NAGAR LAL GHATI BHOPAL M P 462030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L-4 | Rejected-Finance High rates | |
| 5 | L-5₹41.1 L+₹3.3 L (8.77%)Rejected-Finance 50 PANCHVATI COLONY KODARIYA MHOW PIN 453441 | MHOW | MHOW | MP | 453441 | L-5 | Rejected-Finance High rates |
Tender Value
₹48.4 L
EMD Value
₹96,880
Closing Date
2 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
SRW FOR 34 BATHROOMS (GROUND FLOOR- 17 AND FIRST FLOOR-17 OF FRONT RIGHT FLANK) IN BLDG NO WB-261 C (C BLOCK) AT CTW MCTE UNDER GE (MCTE) MHOW
2023_MES_631214_1
GE(MCTE)/MHOW/38(T) OF 2023-24
Open Tender
Civil Works
Works
180 days
GE (MCTE) Mhow
As Per Tender Document
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) Mhow
₹96,880
Yes
26 Feb 2024
6 Dec 2023
4 Jan 2024
6 Dec 2023
2 Jan 2024
20 Dec 2023
Amount
B/R WORK
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar, complete all as specified and directed.
Demolition of Brickwork of stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete (reincorcement cut as required to facilitate demolition) of any description and in any position not otherwise specified complete all as directed.
Taking down cement plaster on brick wall/ ceiling built in cement mortar including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Taking down Chowkhats with shutters (without taking off shutters from the frame) area not exc 1.5 Sqm each complete as specified and directed.
Taking down Shutters of any description exc. 1 sqm but n. exc 2 sqm each of any description complete all as specified and directed.
M&L for Nonskid ceramic tiles 7 to 8mm thick of any shade (square/ rectangular) area of each tile as in floors exc 0.11 and not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bedding layer in cement sand mortar 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450 x 300 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in 1:4 CM complete all as specified and directed.
S & F 35mm thick second class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, moulded on solid (for each side) : supplied and fitted to chowkat, complete all as specified and directed.
M&L for Machine cut mirror polished kota stone slab flooring with rounded edge 20-25mm thick over & including cement screed bed (1:6) 15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
M&L for Machine cut kota stone skirting 18-20mm thick in riser of steps skirting, dado, and pillar over & including 10mm thick backing coat in cement mortar in (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and mirror polishing complete all as specified and directed.
M&L for brick work built in cement mortar (1:6) using sub class “B” bricks (old) size bricks straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and fair incl cutting joints and filling with bitumen and sand mixture complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of concrete/ brick exterior surfaces in cement mortar 1:4 mixed with WPC @ 3% by weight of cement or as per manufacturer instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item as specified and directed.
M&L for rendering, 5mm thick in cm 1:4, on ceiling surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15mm thick on ceiling, chajja in two layers Ist layer 10mm in cement mortar (1:4) on faces of brick work and 2nd layer 5mm in cement mortar (1:4) and finished the surface fair and even using WPC complete all as specified and directed. Note :- WPC shall be measured and paid separetely.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ® 15014B including Providing and applying plaster of paris complete all as specified and directed including four year gaurantee.
M &L for preparation of newly plastered surface of wall and applying two coats of distemper oil emulsion over a coat of alkali resistance primer and 1mm thick cement base wallcare putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying Two coat of distemper oil emulsion incl priming the surface and incl 1mm thick ceiling putty all as directed by Engr-in-Charge.
M&L for preparation of complete removal of existing treatment on surfaces of walls, surfaces should be free from any loose paint, for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. complete all as specified and directed with four year gaurantee.
M&L for complete removal of existing treatment and preparation of of wall, washing, scrubbing down and stopping of distemper and painted surface old plastered/ decorated surface and applying 1mm thick cement base wallcare putty for smooth finished of the surface and applying two coats of distemper oil emulsion over a coat of alkali resistance primer complete all as specified and directed.
M&L for preparation of old plaster surfaces of ceiling and applying two coat of distemper oil emulsion complete all as specified and directed.
M&L for preparation of old plaster surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
M&L for preparation of Old steel surfaces of any description, over 10 cm width or girth and applying one coats of synthetic enamelled paint complete all as specified and directed.
M&L for Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed.
M&L for applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing in SSR Part-II with prelam sheet
S&F Factory made solid panel pvc door shutter 30mm thick consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15 x 15mm for top & bottom rails. M.S. frame shall have a coated of steel primers of approved make and manufacture. MS frame covered with 5mm thick heat moulded PVC "C" channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming styles and 5mm thick 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to from top and bottom rail and 115mm vide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to from lock rail. Top, bottom and lock rail shall be provided either side of the panel 10mm (5mm x 2) thick, 20mm wide cross PVC sheet to be provided as gap insert for top rail & bottom rail. panelling of 5mm thick both side PVC sheet to be fitted with MS frame welded/ sealed to the stiles & rails with 7mm (5mm + 2mm) thick x 15mm wide PVC Sheet beading to inner side and jointed together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C channel using PVC solvent adhesive etc. suppling & fixing in the frame at site as per specification & drawing in SSR Part-II.
S&F powder coated anodised aluminium ventilator, half portion of the ventilator covered with 5.5mm thick frosted glasses and half portion fitted with frosted louvers and outer side fitted with mosquito proof galvanised wiremesh including removing old steel ventilators incl finishing the demolished surfaces with rendering 10-15mm thick CM 1:4 fair finish including filling the holdfast holes with PCC 1:2:4 (12.5mm graded aggregate) including 02 coat of cement based paints with primer incl all fittings, accessories etc all as specifed and directed by Engr-in-Charge.
M&L for Cutting holes in brick/ block walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc half brick n.exc one brick complete as specified.
S & F mild steel bands, straps, support or stays for rainwater ventilating pipes including bolts if required, hook and eye, Hold fasts wall ties hooks for hanging fans, plain angle etc all as specified and directed.
S&F Factory made 35mm thick second class hard wood skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass/ wire mesh, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
S&F in repair anodised aluminium curtain rod/ rail 25mm dia and thickness not less than 0.75mm complete all as specified & directed.
S&F in repair Stainless steel curtain rod brackets 25mm dia including necessary stainless steel clamp complete all as specified & directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame incl punching or drilling out old glazing pins/ spring clips and providing and fixing new ones.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane.
M&L for 3mm thick sheet figured glass, pin headed type and glazing with oil putty in square n exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
S&F in repairs 18mm thick factory made PVC sheet one side pre-laminated sheet ktichen cabinet shutter. The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for marking edge lipping bending for 0.5mm thick PVC sheet lipping at all four edges using bonding tape etc complete all as specified and directed.
S & F in repairs factory made PVC shelf/ partition of required size consisting of panel of 18mm thick required size consisting of panel of 18mm thick celuka PVC ply and for supporting the hold of shelf/ partition and shall provided 3 edges in size 18mm x 18mm as per required lenght the front side of the edge visible in the front of the shelf/ partition to be edge lipped by 18mm widht x 1mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement etc. complete all as specified and directed.
M&L for providing PVC WALL PANELLING of 5mm thick consisting of panel of desired size stuck on inner frame work of 50mm wide strips of 5mm thick prelaminated PVC sheet. The panel & strips shall be density of 600 kg/CBM manufactured by ISO-9001-2015 certified company. The strips should have in their centre a gove of 6mm widht and 1mm depth for sinking the head screws used to fix the strip to the wall vertically at an equal interval of 10 inch between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long MS screws through the groove in the strip by using PVC fasteners the distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall optionally a strips of 5mm thick PVC sheets of width 75mm feathered at the edges shall be stuck at the places where two panels are joined using solvent cement. complete all as specified and directed.
S&F stainless steel shelf closing hinges 75mm size for PVC door shutters complete all as specified and directed.
S&F 50 x 15mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed.
S& F 100mm size MS mat/ glossy finish handle complete all as specfied and directed.
S&F Butt hinges, extruded aluminum alloy with galvanized mild steel hinge pin, anodised and fixed, type C-21 of size 100mm
S & F Aluminum handle cast type anodized size 150mm long, complete all as specified and directed.
S & F Aluminimum anolised barrel tower bolt of extroded section 150mm long, complete all as specified and directed.
S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Hasp & staple aluminium anodised, safety type, including bolt to hinge plate and fixed with screw 100mm size. complete all as specified and directed.
S&F door spring with 300mm mild steel rat rail rod pattern of standard quality including roller and roller plate complete Helical spring), complete all as specified and directed.
S & Fixed in repair Vitreous china, wash down water closet pan (pedestal pattern), white, including plastic water closet seat cover, closed pattern with flat bottom, connection to drain (or outgoing pipe) and to flushing pipe, antisiphonage pipe etc complete all as specified and directed.
S&F in repairs low level Flushing cistern 10 ltr capacity, PVC valveless syphonic action type, white with inlet, ball valve, float valve and handle, flush pipe, incl brackets and flushing pipe fixed in repairs complete all as specified and directed.
S&F in repairs vitreous china, white, wash hand basin, flat back size 550 x 400mm 'including MS brackets including cutting for and pinning in, including waste pipe complete all as specified and directed.
S&F in repair chromium plated brass wall mixer 2-in-1 fancy type with provison for both hand shower and overhead shower complete with wall flange (without hand &over head Shower screwd down for 15mm GI bore pipe complete all as specifed and directed.
S&F in repair chromium plated brass Central hole basinmixer without popup waste system complete screwd down for 15mm GI bore pipe complete all as specifed and directed.
S&F in repair 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F in repairs Health Faucet ABS with Rubbit Cleaning System, 1.25 m Long PVC Flexible Tube & ABS Wall Hook. complete all as specified and directed.
S&F in repair 15mm size PVC connections internally threaded with PVC washer, PTMT nuts of length 450mm complete all as specified and directed.
S&F Grating 100mm dia of CP with or without hole complete all as specified and directed.
S&F in repair 125mm size Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specifed and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as directed.
S & F in repairs Stop/angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions. complete all as specified and directed.
S & F in repairs two way Stop/angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs Toilet Paper Holder Stainless Steel fixed to wall all complete all as specified and directed.
S & F in reparis Stainless Steel Soap Case fixed to wall all as complete all as specified and directed.
S&F in repair corner shelf assembly 300mm consisting of 8mm thick sheet glass with chromium plated bracket guard and railing complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
S&F, laying and testing for 15mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specifed and directed.
Taking up or down steel tubing and connections for bore of tube 20mm, complete all as specified and directed.
S&F GI tubing Medium grade galvanised with all fitting and fixed bore of tube 20mm, with necessary union, socket, nipleetc complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in Stone, concrete block or slab walls
Taking down Old PVC or AC rainwater/ waste/ vent pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fix to wall all as spcified.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fix to wall all as spcified.
S&F PVC (SWR) Bends (any radius), diminishing pieces or tapers, bore of pipe 75mm, complete all as spcified.
S&F PVC (SWR) Bends (any radius), diminishing pieces or tapers, bore of pipe 110mm, complete all as spcified.
S&F in repairs PVC (SWR) Branch pieces, double (double Y) equal or unequal of pipe 75mm bore complete all as spcified.
S&F PVC (SWR) Branch pieces, double (double Y) equal or unequal of pipe 110mm bore complete all as spcified.
S&F PVC floor trap, with grating 75mm including jointing to wast pipe fixed in cement concrete type B1 (1:2:4), in repairs and including waterleak proor treatment complete all as spcified.
Dismantling water tanks and removing to store exc 500 & n. exc 1000 litres capacity, complete all as spcified.
S&F Rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I 1000 litres capacity, complete all as spcified.
S&F in repair 20mm dia Ball valves, of PTMT high pressure, with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15 to 25mm to 142 - 455 gms), complete all as spcified.
S&F in repair 20mm dia Gun-metal, golbe or gate valves, with iron wheel head, screwd both ends or iron pipe and fixed, complete all as spcified.
Taking down existing water proofing treatment of tar felt of any description from roof surfaces and removing rubbilsh to a distance not exc 100mtres complete all as specified and directed
M&L for PCC 25mm thick (1:2:4) type Bo using 12mm graded stone aggregates mixed with integral water proofing chemical PIDI PROOF-LW mixed in proportion of 200ML/50Kg cemet of DR fixit of pidilite industries Ltd or STP No.1 (Liquid) of STP Ltd in proportion 200ML/ 50Kg cement as in padding on roof surfaces and sunken floor for correcting/ making proper slope on roof/ chhaja and roof kerbs/ benching complete all as specified and directed.
M & L for Water proofing on roof/ parapet with testing & 10 year gaurantee as per the follwing steps: STEP-I. Firstly to clean the existing surface of the roof peparation and making the surface dust free. STEP- II. Opening of crack in V groove more than 0.5mm and filling with epoxy mortor. STEP-III. Initial coat (mixed 1/2 litre of water in 1 liter of Roof seal of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT. Dr. Fixit) as a primer (Area cover 1 litre = 9-10 sqmtr) STEP-IV. After six hours of primer, apply first coat (one coat) of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT. Dr. Fixit roof seal in a particular direction without mixing of water. Now left it for six hours (Area cover 1 litre = 1.2 sqmtr). STEP-V. After again six hours of first coat and apply the second coat of Dr. Fixit Roof seal in a other direction without mixing of water (Area cover 1 litre = 1.2 sqmtr). Now left it 24 hours. all as specified and directed by Note :- The work of water proofing treatment shall be got executed through expert team of manufacturers of authorised applicator of manufacturer. Make : Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT or equivalent approved.
M&L for 10mm thick screed bed on concrete surfaces in CM(1:3) finished even and smooth without using extra cement complete complete all as specified and directed.
M&L for Cement concrete type B-2 1:5:10, 40mm graded stone aggregate filling and mass-concrete in sunken floor complete all as specified and directed.
M&L for water proofing treatment to sunken surfaces of the slab in following sequences with testing & 10 years gaurantee
(a) Water proofing Application : Providing and applying accylic cement two component watee proof coating Dr. Fixt Hydrocem/ Dr. Fixit pidifin 2kin two coats @ 0.55-0.58 M2/Kg/2 coats having minimum elongation of 50% Allow the coating to application in adirection perpendicular to the first. Vertical application of coating should be applied up to a height of 1 Mtr, complete all as specified.
(b) Horizontal protection & slope : Providing & laying 50mm THK protective screed or of Cement Concrete of 1:1.5:3 mix admixed with integral compound conforming to IS 2645:2003, Dr. Fixit Pidiproof LW+ @ 200ml per bag of cement or Brick Bat Coba in the sunk area, to provide slope to the horizontal surface towards drain outlet and also to protect the waterproofing, keeping the surface broomed, curing and testing for water tightness for 7 days etc. complete all as spcified.
(c) Vertical protection : Apply a spatter dash bond coat which comprises of Cement : Dr. Fixit URP : Silica sand (1:1:1.5) over the cured water proofing coating and apply the key coat of plaster as wet on wet application. The plaster should be placed approx.12-15mm thick plaster in two coats over the prepared surface of cement sand mortar admixed with integral water proofing compound Dr. Fixit Pidiproof LW+ forming to IS 2645:2003 @ 200 ml per bag of cement, complete all as spcified.
E/M WORK
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified.
Taking down carefully copper/ aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc complete all as specified.
Taking down carefully MCB DBs/ sheet metal earth plug socket any size and any type including MCBs any type and making good the disturbed surface of walls and floors complete all as specified.
Taking down existing geyser any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/ connector complete all as specified.
Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FRLSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including metal flush box, modular cover plate saitable size and cover frame of suitable size all fittings and accessories and making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:-
(a) One light/ fan/ bell point controlled by one way switch, complete all as specified
(b) One 5 Amps socket out let point controlled by one switch on SAME BOARD with other switches.
(c) One 5 Amps socket out let point on independent board controlled by one switch.
All as per item No.102 here in before but using pvc FRLSH insulated unsheathed 2.5 sqmm cross sectional area cable for phase/ neutral & for earth 2.5 Sqmm green PVC FRLSH insulated cable for 15 Amps socket point on independent board complete all as specified and directed for the following:-
(a) One power point controlled by one way switch complete all as specified.
(b) One power point controlled by two way switch complete all as specified.
Supply and fix in repairs Modular Switch flush type 6 Amps single pole, one way complete all as specified.
Supply and fix in repairs Modular Socket outlet, multi purpose, 5 Pin combined 6 Amps flush type complete all as specified.
Supply and fix in repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socket complete all as specified.
Supply and fix in repairs Modular Switch 16 Amps single pole, one way complete all as specified.
Supply and fix in repairs Modular Switch 16 Amps single pole, two way complete all as specified.
S&F in repairs ceiling rose surface bakelite three terminal complete all as directed.
S&F in repairs lamp holder insulated body with back plate for batten fittings complete all as directed.
Supply and fix LED bulb of 7 watt, Of base B-22, suitable for fixing in lamp holde complete all as specified.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient high transmissitivity diffuser, high lumen ouput 230 volts and intregrated electronic driver connector block etc. complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : Havells Cat Part No LHEXBLP7PN1W022 or its equivalent approved in Philips, Wipro.
S & F for LED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make : Havells Cat Part No LHEXACP7IN1W010 or its equivalent approved model in Wipro, Philips.
M&L for Sub main wiring in repairs with two runs of single core PVC FRLSH insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC FRLSH insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 6.00 sqmm cable, one run of 6.00 sqmm cable and one run of PVC conduit will be measured as one unit.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Supply and fix MCB SPN 6 to 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed by complete all as spcified.
Supply and fix MCB SP 6 to 32 Amps 10 KA, 'B' series including connection with suitable size aluminium/ copper lugs complete all as specified
M&L for single pole and neutral encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with one single pole MCB SP 20 Amps complete all as specified and directed. Make : Indoasian Cat Part No 810393 or equivalent approved in Crompton/ L&T/ ABB/ Scheider
Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for 100-125 Amps MCCB as incomer and SPN/ TP MCBs as out going, 6 way (Optium 1+18 Module) complete all as specified.
S&F (in replacement) MCCB 4 pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 63 Amps Adjustable type with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply & fix plastic body exhaust fan, AC single phase 230/ 240 V of size 250/200mm sweep with louver, white in colour including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed.
S & F for water heater storage type (Geyser) vertical/ Horizental type as per site requirement with inner container of capacity 25 ltrs, electrically operated, AC 230 Volts,BEE 5 star rated, ISI marked including 04 Nos of hold fastner nuts required suitable size fixed in brick wall, PVC connection pipe hot & cold for MES IB incliding writting the MES Number with synthetic enamel paint complete all as specied and as directed.
M&L for in repairs for Sub main wiring in repairs with two runs of single core PVC FRLSH insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 4.00 sqmm cable, one run of 4.00 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised Iron Wire of size 4 sqmm as earthing lead by means of bolts, nuts, cheek nut and washers of galvanised iron or steel besides at all joints as shown in Electrical Plate No-3 of SSR Part-I and including excavation and earth work GI pipe 20mm dia light grade protection pipe and including chorcoal filling common salt, PCC 1:3:6 type CI using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 6mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm dia graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both ways with MS handle 12mm dia, CI funnel and wire mesh 20mm dia GI pipe medium grade for watering and connected to earth Test point (Including testing complete all as specified and directed).
M/s Shree Ganesh Traders
Chitragupta Construction
JYOTI ENTERPRISES
BHATIA ASSOCIATES
sunway associates
SATHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .