Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 CrAccepted-AOC OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | ₹24.7 Cr | L1 | Accepted-AOC QUALIFIED |
| 2 | L2₹24.8 CrRejected-AOC YOGESHWARI NAGARI RING ROAD AMBAJOGAI | AMBAJOGAI | BEED | MAHARASHTRA | ₹24.8 Cr | L2 | Rejected-AOC QUALIFIED |
| 3 | L3₹26.2 CrRejected-AOC DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | ₹26.2 Cr | L3 | Rejected-AOC QUALIFIED |
| 4 | Rejected-Technical HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | - | - | Rejected-Technical DISQUALIFIED |
| 5 | Rejected-Technical | - | - | Rejected-Technical DISQUALIFIED |
| Sl No | Description | Qty | Unit | Klassic Associates L3 | OMKAR CONSTRUCTION L1 | Vinayak Construction Ambajogai L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means.. | 2,603.22 | One Cubic Metre | 300 ₹7.8 L | 258.75 ₹6.7 L | 247.37 ₹6.4 L |
| 2.00 | Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means. | 980.62 | One Cubic Metre | 325 ₹3.2 L | 315 ₹3.1 L | 301.14 ₹3.0 L |
| 3.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 meters beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre to 3.0 metre) by Mechanical Means. | 924.15 | One Cubic Metre | 650 ₹6.0 L | 655 ₹6.1 L | 626.18 ₹5.8 L |
| 4.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. | 5,405.39 | One Square Metre | 50 ₹2.7 L | 133.75 ₹7.2 L | 127.87 ₹6.9 L |
| 5.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. | 2,078.34 | One Square Metre | 50 ₹1.0 L | 140 ₹2.9 L | 133.84 ₹2.8 L |
| 6.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. | 2,307.35 | One Square Metre | 50 ₹1.2 L | 135 ₹3.1 L | 129.06 ₹3.0 L |
| 7.00 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete. | 657.22 | One Cubic Metre | 2,300 ₹15.1 L | 1,727.5 ₹11.4 L | 1,651.49 ₹10.9 L |
| 8.00 | Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete.
Spec. No. : Bd.A. 11/Page No. 262 | 715.89 | One Cubic Metre | 150 ₹1.1 L | 150 ₹1.1 L | 143.4 ₹1.0 L |
| 9.00 | Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete.
Spec. No. : Bd.A. 11/Page No. 263 | 886.53 | One Cubic Metre | 1,000 ₹8.9 L | 150 ₹1.3 L | 143.4 ₹1.3 L |
| 10.00 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 milimetre with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications. | 195.36 | One Cubic Metre | 1,200 ₹2.3 L | 1,515 ₹3.0 L | 1,448.34 ₹2.8 L |
Tender Value
₹25.1 Cr
EMD Value
₹12.6 L
Closing Date
11 Oct 2024, 5:30 pmClosed
Executive Engineer,Public Works Division, Akluj
Executive Engineer,Public Works Division, Akluj
Construction of Administrative Building at Karmala Tal.Karmala Dist.Solapur
2024_PWDRP_1095825_1
ETENDER NOTICE NO_05_2024-25
Open Tender
Civil Works - Buildings
730 days
Tal.Karmala Dist.Solapur
As per tender Booklet
3 documents required · 3 mandatory
₹3,540
₹12.6 L
Cheif Engineer, Public Works Region, Pune (Virtual
7 Nov 2025
27 Sept 2024
14 Oct 2024
27 Sept 2024
11 Oct 2024
27 Sept 2024
3 Oct 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means..
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means.
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 meters beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre to 3.0 metre) by Mechanical Means.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 milimetre with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications.
Providing and laying Weep Holes of 100 milimetre diameter Asbestos Cement / PolyVenylChloride pipes as per drawing for abutment returns, return walls etc. complete.
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15of trap/ granite/ quartzite/ gneiss metal for steps including steel centering, plywood/steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Ground Floor Providing and laying cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor Providing and laying cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Third Floor Providing and laying cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Ground Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Ground Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Ground Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Ground Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).
Ground Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / granite /gneiss / quartzite metal for Reinforced Cement Concrete Fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.
Second Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / granite /gneiss / quartzite metal for Reinforced Cement Concrete Fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.
Third Floor Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / granite /gneiss / quartzite metal for Reinforced Cement Concrete Fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.
Ground Floor Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
First Floor Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Second Floor Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Third Floor Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
Ground Floor Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
First Floor Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
Second Floor Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
Third Floor Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
Ground Floor Providing Second class fly ash brick masonry with conventional /Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 milimetre diameter/ two hoop iron strips 25 milimetre x 1.60 milimetre at every third course, properly bent and bounded at ends scaffolding raking joints and watering complete.
First Floor Providing Second class fly ash brick masonry with conventional /Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 milimetre diameter/ two hoop iron strips 25 milimetre x 1.60 milimetre at every third course, properly bent and bounded at ends scaffolding raking joints and watering complete.
Second Floor Providing Second class fly ash brick masonry with conventional /Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 milimetre diameter/ two hoop iron strips 25 milimetre x 1.60 milimetre at every third course, properly bent and bounded at ends scaffolding raking joints and watering complete.
Third Floor Providing Second class fly ash brick masonry with conventional /Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 milimetre diameter/ two hoop iron strips 25 milimetre x 1.60 milimetre at every third course, properly bent and bounded at ends scaffolding raking joints and watering complete.
Ground Floor Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.
First Floor Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.
Second Floor Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.
Third Floor Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.
Ground Floor Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
First Floor Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Second Floor Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Third Floor Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Ground Floor Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
First Floor Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Second Floor Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Third Floor Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Ground Floor Providing and applying plaster with plaster of paris in 6 Milimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
First Floor Providing and applying plaster with plaster of paris in 6 Milimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
Second Floor Providing and applying plaster with plaster of paris in 6 Milimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
Third Floor Providing and applying plaster with plaster of paris in 6 Milimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
Ground Floor Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.
First Floor Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.
Second Floor Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.
Third Floor Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.
Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
First Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
Second Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
Third Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
Ground Floor Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete.
First Floor Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete.
Second Floor Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete.
Third Floor Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete.
Ground Floor Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.
First Floor Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.
Second Floor Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.
Third Floor Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.
Ground Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (Including the primer coat.) etc. complete
First Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (Including the primer coat.) etc. complete
Second Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (Including the primer coat.) etc. complete
Third Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (Including the primer coat.) etc. complete
Ground Floor Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface. (Including primer coat) etc. complete.
First Floor Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface. (Including primer coat) etc. complete.
Second Floor Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface. (Including primer coat) etc. complete.
Third Floor Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface. (Including primer coat) etc. complete.
Ground Floor Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
First Floor Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Second Floor Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Third Floor Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Ground Floor Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
First Floor Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
Second Floor Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
Third Floor Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
First Floor Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqare metre per kilogram with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Second Floor Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqare metre per kilogram with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Third Floor Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqare metre per kilogram with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
First Floor Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Second Floor Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Third Floor Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete).
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
First Floor Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
Third Floor Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
Third Floor Providing and laying jointless Polydee-LM jointless a highly flexible elastometric coating for Reinforced Cement Concrete/ cementitious surface for terrace waterproofing on brick bat Coba/ Reinforced Cement Concrete, after application of TP-42 Primer on perfectly clean substrate (free from loose dust and foreign matter), application of 1st coat of Polydee-LM at the rate 700 gram per square metre applying second coat of Polydee-LM at the rate 700 gram per square metre and finishing the same with sprinkling the AG-10 granules on the wet coating. After finishing covering the treatment with 25 milimetre cement plaster for protection with fibrillated 6 milimetre Plyplast fibre at the rate 125 gram per square metre (to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs.100/- etc. complete.
Ground Floor Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
First Floor Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
Second Floor Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
Third Floor Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
Ground Floor Providing and laying 18 milimetre thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 milimetre (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's reco milimetre endations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Flooring
Ground Floor Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
First Floor Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Second Floor Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Third Floor Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Ground Floor Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
First Floor Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
Second Floor Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
Third Floor Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
Ground Floor Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
First Floor Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Second Floor Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Third Floor Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Ground Floor Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
First Floor Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
Second Floor Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
Third Floor Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standard 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete.
Ground Floor Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
First Floor Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Second Floor Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Third Floor Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Ground Floor Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.
First Floor Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.
Second Floor Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.
Third Floor Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.
Ground Floor Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 milimetre to 30 milimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
First Floor Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 milimetre to 30 milimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Second Floor Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 milimetre to 30 milimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Third Floor Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 milimetre to 30 milimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Ground Floor Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
First Floor Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Second Floor Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Third Floor Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Ground Floor Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
First Floor Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Second Floor Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Third Floor Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimeter thickness for flooring with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with bitumen complete.
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 milimetre thickness of having a strength of 400 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning etc. complete using 100 percent crushed sand.
Ground Floor Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
First Floor Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
Second Floor Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
Third Floor Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
Ground Floor Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete.
First Floor Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete.
Second Floor Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete.
Third Floor Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete.
Ground Floor Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
First Floor Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Third Floor Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Ground Floor Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.
First Floor Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.
Second Floor Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.
Third Floor Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.
Ground Floor Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 milimetre thick as per detailed drawing consisting panelled vertical styles 100 milimetre x 35 milimetre and lock and bottom rail 200 milimetre x 35 milimetre and panels 12 milimetre thick both side commercial ply faced particle board including stainless steel fixtures and fastening and teak wood beading at juncations of panel inserts and as instructed by the Engieer in chagre including three coats of oil painting etc. complete.
First Floor Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 milimetre thick as per detailed drawing consisting panelled vertical styles 100 milimetre x 35 milimetre and lock and bottom rail 200 milimetre x 35 milimetre and panels 12 milimetre thick both side commercial ply faced particle board including stainless steel fixtures and fastening and teak wood beading at juncations of panel inserts and as instructed by the Engieer in chagre including three coats of oil painting etc. complete.
Second Floor Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 milimetre thick as per detailed drawing consisting panelled vertical styles 100 milimetre x 35 milimetre and lock and bottom rail 200 milimetre x 35 milimetre and panels 12 milimetre thick both side commercial ply faced particle board including stainless steel fixtures and fastening and teak wood beading at juncations of panel inserts and as instructed by the Engieer in chagre including three coats of oil painting etc. complete.
Third Floor Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 milimetre thick as per detailed drawing consisting panelled vertical styles 100 milimetre x 35 milimetre and lock and bottom rail 200 milimetre x 35 milimetre and panels 12 milimetre thick both side commercial ply faced particle board including stainless steel fixtures and fastening and teak wood beading at juncations of panel inserts and as instructed by the Engieer in chagre including three coats of oil painting etc. complete.
Ground Floor Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.
First Floor Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.
Second Floor Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.
Third Floor Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.
Ground Floor Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge.
First Floor Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge.
Second Floor Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge.
Third Floor Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge.
First Floor Supplying and fixing in position Powder Coated Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83 kg per metre and top and side section of size 122x 31.75 mm weighing 1.15 kg per running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6 kg per running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete.
Second Floor Supplying and fixing in position Powder Coated Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83 kg per metre and top and side section of size 122x 31.75 mm weighing 1.15 kg per running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6 kg per running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete.
Third Floor Supplying and fixing in position Powder Coated Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83 kg per metre and top and side section of size 122x 31.75 mm weighing 1.15 kg per running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6 kg per running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete.
Ground Floor Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.
First Floor Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.
Second Floor Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.
Third Floor Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.
First Floor Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete.a) Without powder coating
Second Floor Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete.a) Without powder coating
Third Floor Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete.a) Without powder coating
First Floor Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete.
Second Floor Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete.
Third Floor Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete.
Ground Floor Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of overall size 1.50 metre x 2.40 metre or as specified with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter compr Indian Standard Institute ng of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre, 2.90 milimetre thick top rails 47.62 x 44.45 milimetre, 3.18 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels, Indian Standard I. mark, heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beeding, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150milimetre diameter m. pad handle, as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments.
First Floor Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of overall size 1.50 metre x 2.40 metre or as specified with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter compr Indian Standard Institute ng of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre, 2.90 milimetre thick top rails 47.62 x 44.45 milimetre, 3.18 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels, Indian Standard I. mark, heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beeding, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150milimetre diameter m. pad handle, as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments.
Third Floor Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of overall size 1.50 metre x 2.40 metre or as specified with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter compr Indian Standard Institute ng of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre, 2.90 milimetre thick top rails 47.62 x 44.45 milimetre, 3.18 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels, Indian Standard I. mark, heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beeding, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150milimetre diameter m. pad handle, as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments.
Ground Floor Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
First Floor Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
Second Floor Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
Third Floor Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
Ground Floor Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).
First Floor Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).
Second Floor Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).
Third Floor Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).
First Floor Providing and fixing 900 milimetre high S.S. 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 m center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Second Floor Providing and fixing 900 milimetre high S.S. 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 m center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Third Floor Providing and fixing 900 milimetre high S.S. 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 m center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Ground Floor Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
First Floor Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Second Floor Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Third Floor Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete.
Ground Floor Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
First Floor Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
Second Floor Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
Third Floor Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
Ground Floor Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
First Floor Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
Second Floor Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
Third Floor Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
Ground Floor Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
First Floor Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
Second Floor Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
Third Floor Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
First Floor Providing and fixing Ivory glazed urinal of size 710x460x300 milimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
Second Floor Providing and fixing Ivory glazed urinal of size 710x460x300 milimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
Third Floor Providing and fixing Ivory glazed urinal of size 710x460x300 milimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
First Floor Providing and fixing Ivory Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Venyl Chloride flushing cistern of 5 litre s capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.
Second Floor Providing and fixing Ivory Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Venyl Chloride flushing cistern of 5 litre s capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.
Third Floor Providing and fixing Ivory Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Venyl Chloride flushing cistern of 5 litre s capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.
First Floor Providing and fixing ORISSA TYPE colour glazed earthen ware 625 x 450 milimetre Water Closet Pan including trap, C.I.soil and vent pipe upto the out side face of wall including 100 milimetre diameter C.I.plug, bend, 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.
Second Floor Providing and fixing ORISSA TYPE colour glazed earthen ware 625 x 450 milimetre Water Closet Pan including trap, C.I.soil and vent pipe upto the out side face of wall including 100 milimetre diameter C.I.plug, bend, 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.
Third Floor Providing and fixing ORISSA TYPE colour glazed earthen ware 625 x 450 milimetre Water Closet Pan including trap, C.I.soil and vent pipe upto the out side face of wall including 100 milimetre diameter C.I.plug, bend, 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.
First Floor Providing and fixing half turn 25 milimetre diameter gunmetal flushing cock including all accessories complete.
Second Floor Providing and fixing half turn 25 milimetre diameter gunmetal flushing cock including all accessories complete.
Third Floor Providing and fixing half turn 25 milimetre diameter gunmetal flushing cock including all accessories complete.
First Floor Providing and fixing Orissa type white glazed earthenware 575 mm water closetpan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outsideface of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and itsaccessories etc. complete.
First Floor Providing and fixing Ivory european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
Second Floor Providing and fixing Ivory european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
Third Floor Providing and fixing Ivory european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
Ground Floor Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
First Floor Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
Second Floor Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
Third Floor Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
Ground Floor Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
First Floor Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Second Floor Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Third Floor Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
First Floor Providing and fixing wall hung white wash basin of size 350x450x165 milimetre with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge.
Second Floor Providing and fixing wall hung white wash basin of size 350x450x165 milimetre with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge.
Third Floor Providing and fixing wall hung white wash basin of size 350x450x165 milimetre with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge.
First Floor Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
Second Floor Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
Third Floor Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
First Floor Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.
Second Floor Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.
Third Floor Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.
Ground Floor Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.
First Floor Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.
Second Floor Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.
Third Floor Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
First Floor Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.
Second Floor Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.
Third Floor Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.
First Floor Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Second Floor Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Third Floor Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Ground Floor Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.
First Floor Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.
Second Floor Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.
Third Floor Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.
First Floor Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Second Floor Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Third Floor Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
First Floor Providing and fixing Crome Plated pillar cock long neck with aerator of approved make including necessary sockets/union nut etc. complete.
Second Floor Providing and fixing Crome Plated pillar cock long neck with aerator of approved make including necessary sockets/union nut etc. complete.
Third Floor Providing and fixing Crome Plated pillar cock long neck with aerator of approved make including necessary sockets/union nut etc. complete.
First Floor Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.
Second Floor Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.
Third Floor Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.
Ground Floor Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First Floor Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Second Floor Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Third Floor Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Ground Floor Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First Floor Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Second Floor Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Third Floor Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Ground Floor Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First Floor Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Second Floor Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Third Floor Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Ground Floor Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First Floor Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Second Floor Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Third Floor Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Ground Floor Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
First Floor Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Second Floor Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Third Floor Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Ground Floor Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.
First Floor Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.
Second Floor Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.
Third Floor Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete.
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete.
Providing and fixing on walls/ ceiling/ floors, 15 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 1.48 kilograme per metre with necessary fitting, remaking good the demolished portion and applying primer of anticorrosive oil paint in 2 coats complete.
Providing and laying in trenches 40 milimetre diameter medium grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 3.68 kilogram per metre with necessary fitting, remaking good the demolished portion with filling trenches and with primer of anti-corrosive primer oil paint two coats complete.
Providing and fixing on walls/ ceiling/ floors, 25 milimetre diameter heavy grade having embossed as Indian Standard Institute mark galvanised iron pipes of 3.01 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anticorrosive oil paint in 2 coats complete.
Providing and fixing on walls/ ceiling/ floors, 32 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 3.89 kilogrames per metre with necessary fitting,remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete.
Providing and fixing on walls/ ceiling/ floors, 40 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 4.49 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete.
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete.
Providing and laying in trenches 50 milimetre diameter medium grade having embossed as Indian Standard Institute mark galvanised iron pipes of 5.17 kilogram per metre with necessary fitting, remaking good the demolished portion with filling trenches and with primer of anti-corrosive primer oil paint two coats complete.
Ground Floor Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
First Floor Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Second Floor Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Third Floor Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Ground Floor Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
First Floor Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Second Floor Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Third Floor Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Ground Floor Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
First Floor Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
Second Floor Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
Third Floor Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
Providing and laying concrete pipe of Indian Standard Non Pressure class of 100 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters.
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including necessary (excluding excavation and laying)
Providing soak pit of size 120 centimetre x 120 centimetre x 120 centimetre including excavating and filling with brick-bats.
First Floor Providing and fixing machine cut both side mirror polished 18 milimetre to 20 milimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete.
Second Floor Providing and fixing machine cut both side mirror polished 18 milimetre to 20 milimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete.
Third Floor Providing and fixing machine cut both side mirror polished 18 milimetre to 20 milimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete.
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing mild steel grill of angle 75x75x8milimetre with 20milimetre diameter bar at 75milimetre center to center with 75X8 milimetre Mild Steel flat horizontaly placed at center end will be residue including fabricating, fix-tures, erecting, painting the grill work with one coat of anti-corrosive paint and two coats of oil painting with approved colour as per specifiction
Providing fine cement finish 1.5 milimetre thick over green plaster surface including scaffolding curing etc. complete.
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300 milimetre thick side filling around outside of RCC rings (annular space) with 40 milimetre size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75 milimetre clean washed gravels followed by 0.5m depth of 10-25 milimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300 milimetre thick sidefilling around outside of RCC rings (annular space) with 40 milimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 milimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 milimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Boring/drilling bore well of 300 milimetre dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre height letter, figures including painting the letters/ figures with approved colour and shade complete.
Providing and fixing lightening conductor system compr Indian Standard Institute ng of errecting Air-Termination consisting of tubular copper rod of 25 milimetre diameter 1.2 milimetre think with multiple points head 1.2 metre long (Heavy Duty) welded or clamped to Galvanised Iron pipe pole, B Grade 50 milimetre diameter of required length with mild steel round base plate of 25 centimetre diameter and 10 milimetre thick at bottom, embeded in cement concrete block of 1:3:6 foundation of size 45 centimetre diameter x 45 centimetre in height and providing earthing with copper earth plate of size 60x60x0.30 centimetres with cadimium plated nut bolts to fix earthing strips burried in specially prepared earth pit 1.5 metre below ground level with 40 kilogram charcoal and salts with altrernate layers of charcoal and salt and Galvanised Iron pipe 40 milimetre diameter and of 2 metre length burried in earth up to earthing plate remaining portion above ground level for watering and refilling complete.
Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding complete.
Ground Floor Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 milimetre square at 10 cm center to center).
First Floor Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 milimetre square at 10 cm center to center).
Second Floor Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 milimetre square at 10 cm center to center).
Third Floor Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 milimetre square at 10 cm center to center).
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix- 10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
Providing and fixing bituminous pad 25 millimeter thick for expansion joints in retaining wall, compound wall etc. complete
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 metre). By Mechanical Means
Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources).
Construction of granular sub-base by Plant Mix Method by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site,spreading in uniform layers with Motor Grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401.For Grading I Material.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (Natural Sand/ VSI grade finely washed Crushed Sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/ by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing and curing including preparation of sub-grade surface if required etc. complete.
Providing and fixing in position TMT FE-500,32 milimetre diameter dowel bars precoated with anticorrosive epoxy paint 60 centimetre long and at 30.00 centimetre center to center wherever directed including handling, straightening, necessary cutting supported by HYSD chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing and fixing in position TMT FE-500, tie bars precoated with anticorrosive epoxy paint of 12 milimetre diameter 70 centimetre long and at 30.00 centimetre center to center and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening, supported by assembly of HYSD chairs with proper alignment etc. complete.
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for Concrete Road including laying plastic sheet of 125 micron with groove cutting of 4 milimetre wide and 20 milimetre deep, with necessary refilling with Refilling with Polysulfide Sealent (pouring Grade) conforming to BS:5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing polyethylene foam backer road of required diameter (excluding reinforcement) with course and fine agreegates using VSI quality artificial sand etc. complete.
Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00 milimetre thickness in single coat application white(or as required colour) based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2).
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm)
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Barrier type Kerb with gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
GARDEN SOIL : Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10 milimetre sixe free from stones rubbish like dried grass mots and other such materials. The soil should be fresh from qarry. The colour of the soil generally be red. The soil will be measured b measuring box .(Farma) (Item includes Royalty charges ., Transporting, loading unloading etc.) lead charges for 20 k.m. is considered
FARM YARD MANURE :Supplying on site well decayed, well dried , well powered, without clods and free from stones, dried grass and other rubbish material . The colour fo manure generally be black. The manure will be measured by measuring box. (Fanna)(Item includes Transporting , loading unloading etc.) lead charges for 20 k.m. is considered
Preparing Lawn (30 Centimetre.Depth) Excavating the ground to a required depth of 30 Centimetre. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30Centimetre. Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete (R.A.No.1)
Sub Work No -1 Providing Internal Electrification to Proposed New Administrative Building at Karmala Dist - Solapur. Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW ( for Wall Bracket Fan)
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of one hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12 V/26Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
Supplying, installing, testing and commissioning ofsingle phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of Two hr. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (Inverter Battery Rack/ 50 kg -7 Nos)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. Cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW (
Supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 100 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 20 Ports+4G Combo, Managed Layer 2, POE Switch erected in provided rack complete.
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/ GBS
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Providing Supplying, & fixing of 3LCD Projector with 3300 Imns , HDMI USB . VGA Ports . Bright high-quality images with easy to use XGA model featuring 3LCD technology Resolution 1024x768, Contrast Ratio 15000: 1 Throw Ratio 1.44- 1.95:1 Video Color, modes: Blackboard, Cinema, Dynamic. Presentation, sRGB 2 Watt inbuilt loudspeaker, Weight 2.4kg. Colour reproduction upto 1.07 billion colours Aspect ratio 4:3
Providing supplying. & fixting of Motorized 4 x 6 mat finish screen with 2 "black border ,Seamless compund milti-layers diffuse reflection fabric . Tabular Motor with smooth & quiter operation
Proving Supplying & Fixing of celling mount kit Heavy Quality, adjustable with -/+ 15' Tilting. 2 feet x 2 feet to fit EPSON make 3LCD Projector with adjustable Bracket
SUB- WORK - NO-2 Providing External Services allied with Substation Works, Pump system to Proposed New Administrative Building at Karmala Dist - Solapur. Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (For 50& 95sqmm HT cable)
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 600 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
Supplying and erecting minimum Three & above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 1.5 KW/2HP suitable for erection on open well, pump having delivery head from 29 to 7 m and discharge from 30 to 600 litres. . per minute & pipe of Suction 50 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting ISI mark GI pipe 25 mm. dia. ‘B’ class dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting non return valve 25 mm dia in position made of gun metal complete.
Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 48W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries)
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included)
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Supplying, installing, testing and commissioning of 10 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 30 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).(for Solar Mounting stand).
Sub Work No-3 Providing Fire Fighting, Fire Alarm System PA system to Proposed New Administrative Building at Karmala Dist - Solapur. Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height framemade out of 30x30x4 mm angle iron with cross supports forlegs, welded with 4 hooks and duly painted with one coat ofred lead and two coats of silver paint complete.
Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/ SSC/ DP
Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200) mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR.
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
SITC of self Luminous Exit Sign in accordance with BS5499as per sample approved by incharge (FIRE EXIT 300mm X 150mm)
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity,interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Sub Work No-4 Providing Split AC unit with allied services for Proposed New Administrative Building at Karmala Dist - Solapur. Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system.
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( For AC OD Frame-)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. X 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Sub Work No-5 Providing CCTV system Work to Proposed New Administrative Building at Karmala Dist - Solapur. Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, Maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specifications CCTV-HDD
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
Supplying & erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2, Contrast Ratio: minimum 1000:1, Viewing angle: 178/178 deg., Response time: maximum 8 ms, Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multibrand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR
Supplying and erecting modular type 3 pin 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg · Floors :- G+3 floor (4 Stops/4 Landings) · Travel :- 12 mtrs · Location of Lift Machine:- MR/ MRL · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 2000 mm deep,1500 mm Pit depth, 4200 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. A For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift having 700mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. for 3 floor B For Full Collective control system, add as below. 1 For Lift travelling above First floor & up to Sixth floor
Vinayak Construction Ambajogai (BID ID -6279559)
Klassic Associates (BID ID -6266026)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid