Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹5.8 L+₹32,860 (5.98%)Rejected-AOC | L2 | Rejected-AOC REJECT | |
| 3 | L3₹6.3 L+₹85,300 (15.5%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC REJECT | |
| 4 | L4₹9.0 L+₹3.5 L (63.7%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-AOC REJECT |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
18 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NORTH MUMBAI
GARRISON ENGINEER NORTH MUMBAI - 400029
8844 REPAIRS AND REPLACEMENT OF COOLING APPLIANCE AT DGQA UNDER GE NORTH MUMBAI
2020_MES_346138_1
8844/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER NORTH MUMBAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NORTH MUMBAI
₹12,000
Yes
5 Aug 2020
20 May 2020
20 Jun 2020
20 May 2020
18 Jun 2020
4 Jun 2020
21 May 2020 - 3 Jun 2020
60 days
Amount
Supply and fix in repairs sealed compressor suitable for 1.5 Ton Window type AC and making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram or equivalent. Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out from authorized dealers of original manufacturer's only.
All as per item No. 1 described here-in-before but 1.5 Ton Split type AC
Supply and fix in repairs running capacitor 36 MFD, 3 Pole & 2 Pole suitable for 1.5 Ton window / split type air conditioner all as specified and as directed by Engineer-in-Charge. Make : Asian/Unister/Apcos/Electro.
All as per item No. 3 described here-in-before but capacitor 45 MFD
Supply and fix in repairs starting capacitor, 80 to 100 MFD suitable for 1.5 Ton window / split type air conditioner complete all as specified and as directed by Engineer-in-Charge. Make : Asian/Unister/Apcos/Electro
All as per item No. 5 described here-in-before but capacitor 100 to 150 MFD for 2.0 Ton window / split type air conditioner
Supply and fix in repairs starting relay with new starting relay suitable for 1.5 / 2 Ton air conditioner complete all as specified and as directed by Engineer-in-Charge. Make : Asian/Unister/Apcos/Electro
Supply and fix in repairs thermostat control switch for window/ split type Air Conditioner of 1.5 Ton /2.0 Ton capacity complete all as specified and as directed by Engineer-in-Charge. Make : Renutral, Denfos or equivalent.
Material and labour for gas charging R-22 in window/split type AC 1.5 Ton capacity of any make and type, including pressure leakage testing, vacuumsing, rectification, testing and commissioning including suitable size copper tubing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs copper condenser coil assembly for 1.5 Ton AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately
Supply and fix in repairs copper condenser coil assembly for 2.0 Ton AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately
Material and labour for taking down window type / split type air conditioner of any type/make/capacity after dismantling all electric connection from site (either in ground / any floor), transporting to work site, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, decaling with acid on both side of cooling coil and components, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs electric writing kit (PCB) suitable for 1.5 Ton / 2.0 Ton window / split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs full body base suitable for 1.5 to 2 Ton capacity window / split type air conditioner, made out of GI sheet of 14 SWG and other portion with GI sheet of 20 SWG including motor mounting frame fixing with nuts and bolts of suitable size, duly painted with two coats of synthetic enamel paint over one coat of red zinc chrome primer etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Mild Steel bracket (heavy duty) duly power coated paint suitable for outdoor unit of split AC 1.5/2.0 ton capacity including 8 Nos anger bolt 12mm dia x 80mm long complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs outer cover for window / split type AC of Capacity 1.5 to 2 TR, made out of GI sheet 20 SWG, duly painting with two coats of synthetic enamel paint over one coat of red zinc chrome primer complete all as specified and as directed by Engineer-in-charge
Supply, fix and testing of fan blade of motor for widow / split type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton including taking down of old fan blade and removing complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs blower fan motor for 1.0 Ton / 1.5 Ton /2.0 Ton capacity, window / split type Air conditioners including testing, complete all as specified and as directed.
Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs blower drum suitable for split type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs defective front cover grill with new front cover grill suitable for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed.
Supply and fix in repairs capacitor 4 MFD for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed.
Supply and fix in repairs capacitor 6 MFD for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed.
Material and labour for shifting of window type AC of any capacity and make, after dismantling of all electrical connection and carrying it to the new location, refixing it after making suitable size hole in wall, making electrical connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge
Material and labour for shifting of split type AC of any capacity and make, after dismantling inner and outer unit, dismantling suction/discharge pipe, removing all electrical connection and carrying it to new location, refixing including commissioning, testing, and installation complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs of swing motor suitable for window type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs of swing motor suitable for split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs sealed compressor suitable for Water cooler of capacity 40 ltrs, making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out by original company's authorized dealer only.
Material and labour for gas charging R-134 A in water cooler of capacity 40 ltrs including pressure leakage testing, vacuumsing, rectification, testing of entire unit and commissioning including provision of suitable size copper tubing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs starting capacitor 40 Mfd for water cooler complete all as specified and as directed by Engineer-in-Charge. Make : Asian/Unistar/Tibcon/Telsa
Supply and fix in repairs running capacitor 10 Mfd for water cooler complete all as specified and as directed by Engineer-in-Charge. Make : Asian/Unistar/Tibcon/Telsa
Supply and fix in repairs thermostatic control switch for water cooler complete all as specified and as directed by Engineer-in-Charge. Make : Renutral/Ind foss/Annapurna (AES)
Supply and fix in repairs Ball Valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed of 15 mm bore complete all as specified and as directed by Engineer-in-Charge (Minimum weight - 142 gms) Make :Prayag or equivalent as approved by GE.
Supply and fix in repairs single pole and neutral enclosure with a three pin & earth plug with socket complete with one single pole MCB 20 to 30 Amps, 240Volts, 'C series, 50 Hz , breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :Legrand / L&T / Havells
Supply and fix in repairs PVC cable, insulated, unearthed, multistranded, 1100 Volts grade, ISI marked,3 core, 2.5 Sqmm flexible FRLS copper conductor suitable for AC window / split complete all as specified and as directed by Engineer-in-Charge. Make :Finolex / Polycab / Havells
PRABHA ENTERPRISES
Shree Ayyappa Engineering
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .