| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹9.5 L+₹2.0 L (26.3%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹9.5 L+₹2.0 L (27.0%)Rejected-Finance MISRA ELECTROSTATE CENTRE BAR ASSOCIATION COMPOUND CIVIL COURT AYODHYA 224123 UP | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹14.9 L+₹7.4 L (99.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹14.9 L
EMD Value
₹29,720
Closing Date
3 Oct 2023, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/ MAINT OF APFC PANEL, CAPACITOR BANK AND ALLIED WORK AT AYODHYA CANTT UNDER AGE (I) AYODHYA.
2023_MES_617341_1
81773/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) Ayodhya
₹29,720
Yes
11 Nov 2023
5 Sept 2023
10 Oct 2023
6 Sept 2023
3 Oct 2023
19 Sept 2023
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured & Paid.
Supply & laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engineer-in-Charge.
50 Sqmm 4 Core.
70 Sqmm 3. 5 Core.
95 Sqmm 3. 5 Core.
M&L for control relay MXO 4OE (4 NO) (Auxilary Contactor) for automatic power factor correction panel including taking out of old one complete all as specified and as directed.
M&L for ultra heavy duty Capacitors Cylindrical Series of capacity 5 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one complete all as specified and as directed.
M&L for ultra heavy duty Capacitors Cylindrical Series of capacity 10 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one complete all as specified and as directed.
M&L for ultra heavy duty Capacitors Cylindrical Series of capacity 15 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one complete all as specified and as directed.
M&L for ultra heavy duty Capacitors Cylindrical Series of capacity 20 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one complete all as specified and as directed.
M&L for ultra heavy duty Capacitors Cylindrical Series of capacity 25 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one complete all as specified and as directed.
M&L for LED phase Indicator lamp Red/Yellow/blue 16 mm panel mounting type including taking out of old one complete all as specified and as directed.
M&L for Push Button Red/ Green panel mounting type including taking out of old one complete all as specified and as directed.
S&F MCB 415 V, triple pole, 25 to 63 Amps, 'C' curve, 10 kA including taking out of old one complete all as specified and as directed.
S&F in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB, 4 pole, 125 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB, 4 pole, 500 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 30 kVAR including taking out of old one complete all as specified and as directed.
S&F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 12.5 kVAR including taking out of old one complete all as specified and as directed.
S&F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 8.5 kVAR including taking out of old one complete all as specified and as directed.
S&F three phase digital Voltmeter with LED display, accuracy class 1.0, voltage measurement range between phase to phase 50-550 volt AC flush mounting type of size 96 x 96 mm including taking out of old one complete all as specified and as directed.
S&F three phase digital Ammeter with LED display, accuracy class 1.0, AC flush mounting type of size 96 x 96 mm including taking out of old one complete all as specified and as directed.
S&F Current Transformer tape wound ring of capacity 200/5 Amp, burden 15 VA, precision class 1% including taking out of old one complete all as specified and as directed.
S&F Current Transformer tape wound ring of capacity 400/5 Amp, burden 15 VA, precision class 1% including taking out of old one complete all as specified and as directed.
S&F Current Transformer tape wound ring of capacity 500/5 Amp, burden 15 VA, precision class 1% including taking out of old one complete all as specified and as directed.
S&F APFC replay of step (5 +1*) of size 96 x 96 (3 Step APFC controller + 3 step plug-in-module) complete all as specified and as directed.
S&F APFC replay of step (7 +1*) of size 96 x 96 (5 Step APFC controller + 3 step plug-in-module) complete all as specified and as directed.
S&F APFC replay of step (15 +1*) of size 144 x144 (8 Step APFC controller + 3 step plug-in-module + 3 step plug-in-module) complete all as specified and as directed.
M&L for Painting 40 to 200 KVAR APFC Panel, remove by scraping the existing painting, cleaning, filling the cavities and applying single coat of spray painting with synthetic enamel paint (colour approved by AGE (I) including writing the size of capacitor complete all as specified and as directed.
M&L for tools and transport for shiftifng of existing APFC panel from one location and refixing testing and commissioning to another location complete complete all as specified and as directed.
M&L for dismentling/Taking down the existing old unsv APFC Panel complete and transporting the same and depositing MES store yard complete all as specified and as directed.
(B) PF COMPENSATION DETAILS :- (i) 5 KVAR heavy duty capicitor - 02 Nos. (ii) 10 KVAR heavy duty capicitor - 02 Nos. (iii) 25 KVAR heavy duty capicitor - 02 Nos. (C) CONTACTOR DETAILS:- (i) 8.5 KVAR capacity capacitor heavy duty contactor - 02 Nos. (ii) 12.5 KVAR capacity capacitor heavy duty contactor - 02 Nos. (iii) 30 KVAR capacity capacitor heavy duty contactor - 02 Nos. (D) CAPACITOR PROTECTION DETAILS:- (i) MCB 16 Amp TP "C" curve, 10 kA (for 5 KVAR) - 02 Nos. (ii) MCB 32 Amp TP "C" curve, 10 kA (for 10 KVAR) - 02 Nos. (iii) MCB 63Amp TP "C" curve, 10 kA (for 25 KVAR) - 02 Nos.
M&L for installing, testing and commissioning of factry made bus bar chamber comprising of 4 Nos Copper bus bar of 200 Amp rating supported on insulator and enclosed with sheet steel enclosure out door type made out of 3.15 mm thick CRCA sheet, with top edge tappered, dust and vermin proof , having locking arrangement at front and opening arrangement from front & rear both including fixing arrangement on pole/gorunting in floor, with colour coded FRP with compression cable glands for entry & exit of cables, powder coated complete all specified and directed by Engineer-in-Charge.
M&L for Structural steel work using rolled mild steel section of Fe-290 (Gde E-165) like Angles, flat, square, round bars as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc complete all specified and directed
M&L for Cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B1, 1:2:4, using 20 mm graded stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all specified and directed
Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron 4.00 mm dia connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engineer-in-Charge.
M/s RAM LAKHAN GUPTA
MISRA TRADING CORPORATION
His And Her Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .