Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.5 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹29.0 L+₹4.8 L (19.7%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L-2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L-3₹30.7 L+₹6.4 L (26.6%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L-4₹31.4 L+₹7.1 L (29.4%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L-5₹35.3 L+₹11.1 L (45.7%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
31 Jul 2021, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
REPAIR, MAINTENANCE AND REPLACEMENT OF INTERNAL WIRING INCLUDING FITTINGS, COOLING APPLIANCES, CEILING FANS, EXHAUST FANS, MES INSTALLATION AND CONNECTED WORKS AT DAMANA UNDER GE JAMMU
2021_MES_456966_1
GEJC-26/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹80,000
Yes
28 Oct 2021
3 Jul 2021
2 Aug 2021
3 Jul 2021
31 Jul 2021
17 Jul 2021
Amount
Charges for attending E/M petty complaint in respect repair/rectification of fault in electric fitting MCB DBs,internal wiring LT Panel and fixture and rectify the faults and replacement of unsv any type of fitting/fixture, MCB's, any type, bakalite sheet restore the electric supply and made the item functionable light point, fan point, socket point 5A/15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DBs and all electrical accessories and day to day /door to door maintenance, making the points/accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 mtr) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses and as directed. The scope also include cutting of existing bakelite sheet to accommodate new wiring accessories all type electric fitting/fixture.
Note : Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting/fixture and MCB's of any type is deemed to be included in the above item.
(i) Contractor representative/engineer will report to complaint cell for morning and afternoon to collect routine/urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (two electrician and two helper) equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type and requisite T&P items to his tradesman. All routine/ urgent job received on job slip will be repaired and got signature of user's and will be deposited to complaint cell with in 24 hrs. In case of any delay in attending the complaint more than 12hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (iii) If the Contractor did not attend complaints a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deems to included in the item for repair i.e. Electrician/Helper, as all the items of CA are to be supply and fixed by the contractor. (v) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (vi) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (vii) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and directed.
Supply only Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only bell, AC 230 volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only holder any type for batten fitting including taking old one ISI marked complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps, 240 Volt 'B' series complete all as specified and directed.
Supply only SPN 32 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per Serial item No 18.00 here-in-before but one 5 pin socket outlet 5 amps on the same board complete all as specified and directed.
Description all as per Serial item No 18.00 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
Description all as per serial item No 18.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including new CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per Serial item No 22.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per serial item No 22.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and directed.
Description all as per serial item No 22.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
Description all as per serial item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non metallic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.
Description all as per serial item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including pressed steel with existing colour terminated boxes of Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Note: Suitable module white cover sheets with frame as specified to be provided in replacement to MS/Galvanised sunken boxes and measured and paid separately as per relevant item. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per serial item No 28.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per serial item No 28.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and directed.
Description all as per serial item No 28.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F in replacement modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
M&L for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be of same make.
M&L for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCBs should be of same make.
M&L for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCBs should be of same make.
S&F in replacement MCCB 4 pole, 415 volt fixed thermal and fixed magnetic setting of cap 125 Amps 16 KA complete all as specified and directed.
S&F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
S&F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
Supply and fixing in replacement of SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
Supply and fixing in replacement of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
Supply and fixing in replacement of 415 V 10 KA 'B' curve TPN 40 to 125 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and directed.
S&F in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and directed.
S&F in replacement for switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and directed.
S&F in replacement for socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
S&F in replacement for socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and directed.
S&F in replacement for switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and directed.
S&F in replacement for switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts complete all as specified and directed.
S&F in replacement for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and directed.
S&F in replacement for ceiling rose 3 terminal surface type complete all as specified and directed.
S&F in replacement for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement for Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed.
S&F in replacement for LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and directed.
S&F in replacement of LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb complete all as specified and directed.
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F in replacement calling bell Ding Dong/buzzer AC 230 Volts, single pole complete all as specified and directed.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 4.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sq mm for phase and neutral and one run of 2.5 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sq mm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sq mm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube floor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion including taking down old unsv earthing complete with galvanised mild steel earth plate electrode complete all as specified and directed.
S&F in replacement unsv wooden/CI Shunken box with new CRCA pressed steel terminal box of size 7 X 4' including taking down old complete with cemented and patch work complete all as specified and directed.
S&F in replacement unsv wooden/CI Shunken box with new CRCA pressed steel terminal box of size 4 X 4' including taking down old complete with cemented and patch work complete all as specified and directed.
S&F in replacement unsv wooden/CI Shunken box with new CRCA pressed steel terminal box of size 10 X 8' including taking down old complete with cemented and patch work complete all as specified and directed.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8 '' X 5'' complete all as specified and directed.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12'' X 10'' complete all as specified and directed.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5'' X 5'' complete all as specified and directed.
Supply and fixing in replacement of plug top 15 Amps complete all as specified and directed.
S&F in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with Copper bus bars, neutral links, Earthing bar complete all as specified and directed including taking down old UNSV DB/MCB any type. Note:- (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCBs shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt along with switch piano 5 amp 240 volt complete all as specified and directed.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt along with switch piano 15 amp 240 volts complete all as specified and directed.
Notes :- (i) For Serial No 17 to 81 : The Contractor has to complete the work assigned for above items with in 72 hrs failing in which recovery at the rate 25 Rs. Per complaint per day. (ii) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deems to included in the item for repair i.e. Electrician/Helper, as all the items of CA are to be supply and fixed by the contractor. (iii) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (iv) All the complaint slip, register and connected document will be provided by the contractor without any extra cost. (v) After any repair the site has to be cleaned and make the surface good.
Labour for repair/servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair/washing/varnishing and removing of old lubricating substance from bearing/bush using Kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning, including replacement of worn out/unserviceable minor spare parts, split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES Store yard. (Replacement of Spares flexible wire etc/rewinding of ceiling fan shall be measured and paid separately under respective item for material and labour cost).
Description all as per serial item No. 84.00 here-in-before but for exhaust fan of any type mm sweep complete all as specified and directed.
Description all as per serial item No. 84.00 here-in-before but for wall mounting fan of any size / type complete all as specified and directed.
Rewinding of ceiling fan, of any make / type and size (1200/1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator/rotor, connection and testing complete all as specified and as directed.
Description all as per serial item No 87.00 here-in-before but for exhaust fan of any make / type and size complete all as specified and directed.
Description all as per serial item No 87.00 here-in-before but for wall mounting fan of any make/type and size complete all as specified and directed.
Labour for remetalling of worn out shaft of fan, cutting, brazing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation complete all as specified and directed. (Bearing shall be measured and paid separately).
Supply and fixing ball bearing of any size and type, suitable for any type/make/size of ceiling Fan complete all as specified and directed.
Description all as per serial item No 91.00 here-in-before but for exhust fan of any type/make and size complete all as specified and directed.
Description all as per serial item No 91.00 here-in-before but for wall mounted fan of any type/Make and size complete all as specified and directed.
Supply, fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceilling fan, Exhaust Fan and Wall mounted Fan complete all as specified and directed.
Description all as per serial item No 94.00 here-in-before but of rated capacity 4.0 MFD for Exhaust Fan complete all as specified and directed.
Supply and connection of PVC insulated, unsheathed multi stranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and directed.
Supply and fixing only bush of suitable size for exhaust fan of any type/size as per existing type complete all as specified and directed.
Description all as per serial item No 97.00 here-in-before but suitable for wall mounted fan of any type/size as per existing type complete all as specified and directed.
Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and directed.
Supply and fixing of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and directed.
Supply and fixing of GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long, 10 mm dia half threaded type with split pin hole complete all as specified and directed.
S&F in replacement MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and directed.
S&F in replacement of ceiling fan down rod 12 mm dia and 30/45 cm long complete with MS Clamp Rubber reel, split pin, nut, bolts etc complete all as specified and directed.
Supply and fixing in replacement of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground/First/Second floor etc complete with using fastener bolt, drilling for exhaust fan up to 400 mm sweep including taking down old one complete all as specified and directed. Note : (i) Rates are deemed to be including charges for hiring any type of T&P ladder, cutter etc. (ii) Contractor shall be responsible for life care of staff deployed for fixing louver shutter.
Cleaning of ceiling fan assembly of any type/size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and directed.
Description all as per serial item No 105.00 here-in-before but for exhaust fan upto 450 mm complete all as specified and directed.
S&F in replacement PVC canopy set of two pieces for ceiling fans of any size complete all as specified and directed.
Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing, lubrication and assembling complete all as specified and directed.
S&F in replacement of Ceiling Fan blade set of three pieces suitable for 1200/1400 mm sweep of White/Brown/Ivory colors complete all as specified and directed.
M&L for repair/Maint to desert coolers complete with and including cleaning, scrapping/rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint over a coat of red oxide primer externally and black paint internally with synthetic enamelled paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No/unit name complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt,1400 RPM, 230 volt 50 Hz single phase conforming to ISI complete with fan blade and capacitor of sutitable size complete all as specified and directed.
Supply and fixing in replacement of Desert cooler submersible pumping set single phase 230 volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead complete all as specified and directed.
Supply and fixing in replacement of PVC accessories of desert cooler i.e. PVC pipe 20 mm dia heavy duty 2 mtr appx, PVC distributor 4 way with nut, bolts, PVC elbow - 03 Nos, MS clamps etc complete all as specified and directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from MS having duty complete with key bolt complete all as specified and directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty MS sheet and matching with the existing Desert Cooler body size complete with Khas Khas pads set of three pieces complete all as specified and directed.
Supply and fixing in replacement of Desert Cooler UNSV/leakage body made out from heavy duty MS Sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow - 03 Nos, PVC distributor 4 way - 01 No, PVC distrbution pipe - 2 mtr appx, Black painted internally, Aluminium painted externally complete with provn of necessary arrangement for fixing front cover and fan motor complete all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement of plug top 3 pin 5 Amp 230 volt 50 Hz complete all as specified and directed.
M&L for fabrication of Desert Cooler stand made out from angle iron 40X40X6 mm thick, bend to shape, welding as per site requirement fixing in brick/stone masonary wall complete with cemented work necessary rawl plug, nut, bolts etc including taking out old cooler stand complete all as specified and directed.
Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for Desert Cooler fan motor, 230 volt 50 Hz complete all as specified and directed.
Supply and fixing in replacement of unsv Khas Khas/Glass wool for desert cooler set of three pieces complete all as specified and directed.
Repair/Maint/Servicing to refrigerator/deep freezer/water coolers/AC's of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing/Chiller plant/water tanks, condensing coils, repair to wiring, flushing/cleaning condensing/cooling coils/internal/External unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator/deep freezer/water coolers/AC's in serviceable condition complete all as specified and directed by Engr-in-Charge. Note: Spare/Gas charging shall be paid separately.
Charges for fixing in replacement of unsv sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling/charging of refrigerant gas to meet the requirement complete with vibration rubber pads four no's each nut, bolts etc and testing on full load complete all as specified and directed by Engr-in-charge. (Spare parts shall be measured and paid separately under respective items). Note :- "Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised service center. Further, a warranty of 12 month shall be provided on such replacement in writing."
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas conforming to ISI as under:-
For refrigerator 165/286 Ltr capacity
For refrigerator 290/320 Ltr capacity
For Deep Freezer 100/200 Ltr capacity
For Deep Freezer 300/400 Ltr capacity
For Water Cooler 40/80 Ltr capacity
For Water Cooler 60/120 Ltr capacity
Split/Window AC 1.5 Ton Capacity
Split/Window AC 2.0 Ton Capacity
Supply and fixing in replacement of unsv/burnt condensing fan motor 1/35 HP Single phase 230 volt 50 Hz complete with blade, fan belts for water cooler of capacity 40/80 Ltr and 60/120 ltr complete all as specified and directed.
Supply only condensing fan motor 1/5 HP 1440 rpm single phase 230 Volt 50 HZ with double blade and shaft end with fan belts for windows AC/Split AC conforming to ISI of capacity 1.5/2.0 ton complete with vibration parts etc complete all as specified and directed.
Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator/deep freezer/water coolers/AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and directed.
Supply and fixing in replacement of following spare parts for refrigerator/deep freezer/water coolers/AC's of any capacity:-
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unsv spare parts of water cooler of any capacity: -
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/Wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unsv following spare parts of window/Split AC unit of capacity 1.5 to 2.0 ton: -
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PCB of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible branded pipe of 20 mm dia for Split AC water drain out complete all as specified and directed.
Supply and fixing in replacement of outer split AC condensing unit complete for Split AC 1.5 ton complete all as specified and directed.
Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for split AC 1.5 ton complete with all accessories complete all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection/repair complete all as specified and directed.
Supply and fixing in replacement of condensing unit of Refrigerator/Deep Freezer/Water Cooler of any capacity complete with cutting and brazzing work complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 5 KVA complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 3 KVA complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 2 KVA complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 1 KVA complete all as specified and directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/stay assembly/cable complete all as specified and directed.
M&L for road cutting, PCC hard standing with width 0.4 and depth 0.9 mtr including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25m thick complete all as specified and directed.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.
M&L in replacement of GI Pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and directed.
M&L in replacment of GI Pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and directed.
M&L in replacment of GI Pipe light grade 40 mm bore for cable protection as a guard pipe or for holding of air termination rod complete all as specified and directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge in trenches over the cable for protection.
Supplying & Laying in ducts/trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil at E/M installation inside the peripherry of installation and deposit removal materials 50 mtr away from the site complete all as specified and directed.
M&L for loose filling with aggregate of gauge 40mm broken stone and boulder deposited, spread, levelling in larger n.exc 15 cm thick, watered and ramming at E/M installation around 50 mtr of transformer complete all as specified and directed.
Taking down cement plaster of any description on bricks or stone walls or from concrete surface or from concrete surface and similar including racking out joints, hacking for key, scrubbing down with water and removing unserviceable material outside the cantt area complete all as specified and directed by Engr-in-Charge.
M&L rendering 10 mm thick (average) in CM 1:4 on concrete surface/brick surface and similar including two or more dubbing coat, surface finished even and fair without using extra cement with necessary frame work, scaffolding for external surface complete all as specified and directed.
Taking out existing burnt defective under ground XLPE cable of any size of 1100 volt grade from trenches/poles complete with protection pipe, sand cushioning, bricks etc for repair/rectification of fault and relaying the same cable in position after necessary repair/rectification of fault complete with relaying old bricks/sand, protection pipes etc and connection incuding testing all as per site requirement complete all as specified and directed.
Repair/maint of existing burnt defective UG XLPE cable 1100 volt grade cable of any size complete with charges for trace out the fault, cutting/repair and jointing complete with using insulation tape, aluminium thimble, lugs, fitment of jointing kit, thimbles, necessary earth work complete all as specified and directed. Note : Aluminium thimble, lugs, jointing kit, thimbles, earth work shall be measured and paid seperately.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 300 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 240 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 185 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 120 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 70/95 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 50 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 35 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs/thimble of size 25 sqmm complete all as specified and directed.
Supply and fix in replacement of cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 25 to 95 sq mm complete all as specified and directed.
M&L in replacement of cable jointing kit for 11000 Volts grade (E) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 sqmm to 95 sqmm and jointing materails for making joints and testing complete all as specified and directed.
M&L in replacement of cable jointing kit for 11000 Volts grade (E) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 to 120 Sqmm and jointing materails for making joints and testing complete all as specified and directed.
M&L in replacement of cable jointing kit for 11000 Volts grade (E) cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 sqmm to 95 sqmm and jointing materails for making joints and testing complete all as specified and directed.
M&L in replacement of cable jointing kit for 11000 Volts grade (E) cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 to 120 Sqmm and jointing materails for making joints and testing complete all as specified and directed.
S&F in replacement of PVC fibre separator for LT line 1100 volt OH conductor 3 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and directed.
S&F in replacement of PVC fibre separator for LT line 1100 volt OH conductor 4 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and directed.
S&F in replacement of PVC fibre separator for LT line 1100 volt OH conductor 5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and directed.
Labour for re-straining, tightening of existing saged ACSR OH conductors spans of any size/type on HT/LT poles including necessary new aluminium binding wire for fixing with insulator/PVC sleeves for jumper etc as required complete all as specified and directed. Note : Pole to pole will be considered as one span of any length and no's of conductor).
Supply and fixing in replacment of ACSR conductor of any size and type from over head HT/ LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT/HT poles complete all as specified and directed.
M&L in replacement of Galvanised steel wire 4.0 mm dia for continuous earth wire and Cradles hexagonal/rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire complete all as specified and directed.
M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e M.S. channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete all as specified and directed.
Labour for cutting of tree branches 2 mtr vicinity of the conductor which are touching to the 11/9 mtr Over Head Lines in vertically & horizontally conductor and poles etc, complete clear in a standard Span in between two poles as per SSR Part-I, 19.59 and removing cutting material not exc 50 mtr and depositing where directed at a distance level not exc 3 mtr from starting point. Note : Pole to pole will be considered as one span of any length and no's of conductor.
M&L for welding to damaged/broken hinges of unsv LT panel board shutters complete with painting and matching with existing colour complete all as specified and directed. Note: - Welding of two no hinges will be considered as one Job.
M&L for replacement of old unsv/broken shutter of LT panel with 3 mm thick CRCA sheet as per existing size to match with the existing panel duly powder coated and welding hinges and fixing complete all as specified and directed by Engr-in-Charge.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing surface internally and externally including preparation of old rusted surface after taking proper shut down complete all as specified and directed by Engr-in-Charge.
M&L painting of transformer externally with two coats of spray painting with heat resistance/smoke grey heat resistence synthetic enamelled paint after cleaning rusted surface thoroughly with thinner and scrapper and preparing the surface to required standard including writing and marking such as MES No, SM No, Capacity, on the body of transformer capacity upto 400 KVA complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular poles 11/9 mtrs long type 410 SP-31, 55 and applying one coat of synthetic enamel paint up to 1.2 mtr height in black and white strip of width 30cm each as per exising pattern above the PCC coping and two coats of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles up to 1 mtr radius complete all as specified and directed.
Material and labour for preparation of old painted surfaces of PCC poles 11/9 mtrs long type 410 SP-31, 55 and applying two coats of synthetic enamel paint up to 1.2 mtr height in black and white strip of width 30cm each as per existing pattern above the PCC coping and two coats of aluminium paint to cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles up to 1 mtr radius complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular two pole structure 11/9 mtrs long type 410 SP-31, 55 and applying one coat of synthetic enamel paint up to 1.2 mtr height in black and white strip of width 30cm each as per exising pattern above the PCC coping and two coats of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles up to 1 mtr radius complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular four pole structure 11/9 mtrs long type 410 SP-31, 55 and applying one coat of synthetic enamel paint up to 1.2 mtr height in black and white strip of width 30cm each as per existing pattern above the PCC coping and two coats of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles up to 1 mtr radius complete all as specified and directed.
M&L for cleaning to over head RCC reservoir of any capacity internally at appx 40 feet high stagging by using water treatment chemical/bleaching powder/Sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising / distribution sluice valves complete all as specified and directed.
M&L for cleaning to under ground sump of any capacity internally at any height/ stagging by using water treatment chemical/bleaching powder/Sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising / distrbution sluice valves complete all as specified and directed. Note: Rate of labour to empty tank deem to be included in quoted rates.
Material and labour for providing two coats of synthetic enamelled base paint on external surface of MS Sheet/ rails /rising main / distrbution pipe / wash out MS / CI pipe with suitable colour coding to OH RCC reservoir at stagging appx 22 mtr complete all as specified and directed.
Material and labour for preperation of existing cement base plaster surfaces of upto 22 mtr height and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank and UG Sump, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of any capacity over head tank and UG Sump complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of integral LED Aviation obstruction light 30 Watt comprising of aluminium housing with polycarbonate enclosure with decorated opal acrylic diffuser with IP-65/66 protection complete all as specified and directed. Make: Bajaj, C&S, Havells
S&F in replacement of Air termination single pointed aluminium rod 12 mm dia and 300mm long fixed with 40mm dia, 4 mtr long GI Pipe including providing flat iron clamps, nuts and bolts, embedding the GI pipe in PCC M-10 block (nominal mix) of size 30 x 30 x 40cm and connecting complete all as specified and directed by Engr-in-charge. Note: GI pipe and PCC will be measured and paid separately.
S&F in replacement of Aluminium strip 25 x 3.15 mm on OH tank with saddle on min distance of 0.5 mtr through out the aluminium strip including nuts, bolts, washers, screws complete all as specified and directed by Engineer-in- Charge.
S&F in replacement of GI strip 32 x 6mm as earth continuity conductor for loop earthing complete with fixing of saddles, nuts, bolts, washers, screws complete all as specified and directed.
M&L in replacement of Test point terminal block made of flat earth strip metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 no's 8mm dia 25mm long hex head screw complete all as specified and directed.
M&L in replacement of old existing unsv mechanical water level indicator for OH RCC reservoir / UG sump with replacement of GI pulley (02 No's), GI wire rope as per site requirement, S.S. float valve of suitable size and painting of indicator, scales with black/red paints (radium type), marking on scales (as per site requirement) with all accessories and testing complete all as specified and directed.
Labour charges for repair/replacement of old/damaged MS sheet cover on valve pits 3.15 mm thick with handle and locking arrangement, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fashioners length not less than 15cm - 04 No's) and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 25x4mm by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part-I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, connected to LT panel board as indicated including testing including taking out old earthing complete all as specified and as directed.
Note: For Item No 145 to 202 (i) Rates are deem to be included charges of hiring T&P, Veh, Ladders, steel shuttering or any equipment required at site for execution of work. (ii) Contractor shall be fully responsible for life insurance of the person deployed at site and get the repair under his supervision. (iii) Contractor will take the permission for shutdown the electric supply in writing for cutting of tree branches, re-stretching etc.
M/S Chib Engineers
M/s. Aggarwal Engineers
BMMJ TRADERS AND ENGINEERS
M/S LANGER CONSTRUCTION COMPANY
Bidder Name
BMMJ TRADERS AND ENGINEERS
M/S Chib Engineers
Sarbat Construction Co
M/s. Aggarwal Engineers
M/S LANGER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .