Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹41.8 L+₹1.9 L (4.65%)Rejected-Finance 385 GROUND FLOOR GANESH MURTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹48.1 L+₹8.1 L (20.4%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹52.5 L+₹12.5 L (31.4%)Rejected-Finance INDEX NO D 91 CESC PUNE R NO 15 6 10 JAISWAR CHAWL JAGRUTI MITRA MANDAL D M ROAD VAKOLA SANTACRUZ E MUMBAI 400055 | MUMBAI SUBURBAN | MAHARASHTRA | 400055 | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹55.7 L+₹15.8 L (39.5%)Rejected-Finance FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
30 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
Garrison Engineer NW Kunjali Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 400005
8383 REPAIR MAINT TO CERTAIN BR NATURE MARINE ASSETS AND OTHER CONNECTED ITEMS IN CRUISER WHARF AND ASSOCIATED AREAS AT ND MB
2021_MES_447908_1
8383/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹96,000
Yes
21 Jul 2021
2 Jun 2021
2 Jul 2021
9 Jun 2021
30 Jun 2021
16 Jun 2021
2 Jun 2021 - 9 Jun 2021
60 days
Amount
S&F in repairs 1st class hardwood (TEAK WOOD) Plain, solid, straight, rebated on the solid, rounded or chamfered segmental supplied and fixed (wooden planks of size 3000 mm x 300 mm x 150 mm) including MS fastner size as per directed by Engineer-in-Charge including filling the fastener holes/gaps with microconcrete etc., complete all as specified and as directed.
S&F in repairs 1st class hardwood (TEAK WOOD) Plain, solid, straight, rebated on the solid, rounded or chamfered segmental supplied and fixed (wooden planks of size 2000 mm x 300 mm x 150 mm) including MS fastner size as per directed by Engineer-in-Charge including filling the fastener holes/gaps with microconcrete etc., complete all as specified and as directed.
S&F in repairs 1st class hardwood (TEAK WOOD) Plain, solid, straight, rebated on the solid, rounded or chamfered segmental supplied and fixed (wooden planks of size 1000 mm x 300 mm x 150 mm) including MS fastner size as per directed by Engineer-in-Charge e including filling the fastener holes/gaps with microconcrete etc., complete all as specified and as directed.
M&L for preparation of new decorated wooden surfaces of any description over 10 cm width or girth, applying two coat of synthetic enamel paint over a coat of pink primer of approved colour all as specified and directed.
M&L for preparation new decorated wooden surfaces of any description over 10 cm width or girth, applying two coat of synthetic enamel paint of approved colour over a coat of pink primer all as specified and directed.
Material & labour as fixed in repair for Stainless steel decorative railings, staircase (design and pattern as approved) made out of SS pipes, SS flats, SS plates etc. of grade 316 complete with and including necessary welding, buffing/ polishing and fixing complete all as specified and directed by Engineer-in-Charge. Design for stairs/ladders or any others will be as approved by GE.
Material & labour as fixed in repair for Stainless steel decorative railings chains alloy grade 316 having 8mm minimum thickness (design and pattern as approved) as used to connect two stainless steel post with hooks etc. complete with and including necessary welding, buffing/ polishing and fixing complete all as specified and directed.
M&L for taking down, chipping and removing the loose, spilt, damaged cement concrete, cement mortar surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned rebar surface wash the rebar with clean water for removing all rusts from the old rebar surfaces, fixing new reinforcement to strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortar in CM 1:3 mix , 40mm thk in two coats, using polymer as per manufacturer's instructions and including scaffolding upto any height complete all as specified and directed. Make : Dr. Fixit/Sunanda/chemestik/Fosrok Note :- New reinforcement and MS Sections will be measured and paid separately
Demolition of cement concrete in coving above Chajja, canopy etc including removing loose particles and cleaning the surface with water after brushing with wire brush etc and including scaffolding upto any height complete all as specified and directed.
M&L for PCC (1:1½:3), type B0 using (12.5mm graded stone aggregate) as in coving above Chajja, canopy etc and including scaffolding upto any height complete all as specified and directed.
M&L for Complete removal of existing water proofing treatment upto concrete surface of roof slab including cleaning, wire brushing, watering, removal of debris out side from MD Land complete all as specified and as directed
M & L PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope complete all as specified and as directed
M&L for taking down, chipping and removing the loose, spilt, damaged cement concrete, cement mortar surfaces of RCC Columns, beams, walls, chajjah etc and stone/concrete in jetty , dock, retaining wall, piers of jetty and bottom portion of deck slab etc above sea including all necessary equipment such as scaffolding etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned rebar surface wash the rebar with clean water for removing all rusts from the old rebar surfaces, fixing new reinforcement to strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and jacketing around columns/beams / other RCC members with Micro concrete (Mokith-MC) including all lifts, shuttering, drilling holes and fixing shear anchor/deficient reinforcement as per manufacturer's specification and including scaffolding upto any height complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately. (Rates quoted shall be including jacketing, formwork and micro concrete). Make :- Dr. Fixit, STP, Fosroc as approved.
M&L for replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as specified and directed
Providing and fixing additional main steel bar or stirrups of designed diameter in various structural elements like column, beams and foundations including drilling, bending and fixing the bars with epoxy putty etc. complete all as specified and directed (Steel provided on the basis of 1% of volume of concrete).
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzles directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzles in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty and including scaffolding upto any height
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency, Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/ specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating and including scaffolding upto any height complete filling of grout in the holes drilled. Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd.
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including Mixing of material as: Mixing of material components (part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting: Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100/Protectsil CIT or Ferogard 903. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles and including scaffolding upto any height
M&L for applying oil bound primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree celsius on the prepared dry roof surface and provide and lay 4mm thick APP modifed water proofing membrane reinforced with non-woven polyster matt with physical properties as given in particular specification. The laying shall got be done through authorized applicator of manufacturer as specified in particular specifications. Provide over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/sqm as prescribed by manufacturer of membrane including Ten years guarantee on prescribed form complete all as per particular specification , manufacturers instructions and as directed by Engineer-in-Charge. Note : Rate inclusive of taking down and refixing of existing lightning arrestor system including provision of new PCC block for damaged PCC block and disconnecting water tank,water connection pipe and refixing the same complete as directed by Engineer-in-charge
M&L for brushing neat cement slurry with 3Kg of cement per square metre all as specified and directed.
M&L for rendering 20 mm thick cement plaster in CM (1:3) on roof top surface finished even and fair including WPC by weight of 3% of total cement content complete all as specified and as directed. Note : WPC will be measured separately
Supply only integral water proofing compound
M&L for factory made cement concrete tiles 25cmX25cmX22mm thick, machine pressed with glossy finished, (with grey cement & no pigments), set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:3 all as specified & directed.
Material & labour for cleaning the surface of the stone/concrete in jetty, dock, retaining wall, piers of jetty and bottom portion of deck slab etc above sea with mechanical grinder and specialized water misting techniques applying water jet using a fine nozzle sprinkling system calibrated to spray a fine mist along the stone/concrete surface complete and removing all sea vegetation complete all as specified and directed. Note:- Quoted rate shall be inclusive of scaffolding or alternative way of carrying out the work with proper safety instruction required at site.
Material and labour for applying two coats of preventive coating (minimum thickness 150micron) to protect against attack of acidic gases, sulphate , chloride, carbon dioxide, like DEKGUARD S of FOSROC, SIKA or equivalent over a coat of primer DEKGUARD of FOSROC, SIKA or equivalent as per manufacturer's instruction over concrete surface in jetty/dry dock above sea level complete all as specified and as directed. Note:- Quoted rate shall be inclusive of scaffolding or alternative way of carrying out the work with proper safety instruction required at site.
Demolition of cement concrete in ground floor and paving any thickness below or above ground level unreinforced complete all as specified and directed
Material and labour for Polymer modified concrete (prepared at site or Ready mix as per instruction) in Pavement/Hard standing of Design Mix M-40 grade with synthetic fibre reinforcement, laid in bays or as directed with and including steel formwork to sides of concrete & laid, spread, compacted and finished in a continuous operation including all as specified and directed. Note :- (i) The flexural strength of concrete shall be 40 KN/mm2 at 28 days on field is to be achieved without considering the effect of synthetic fibres. (ii) Rate quoted shall be inclusive of Synthetic fibre reinforcement @ 125gm per bag of cement. Item to be mixed at site in presence of JE/Engineer-in-Charge. (iii) Cost of admixtures required to achieve the desired properties of concrete shall deemed to be included in the quoted rate. (iv) Quoted rate is deemed inclusive of cost of necessary form work as required at any height.
M & L Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
S & F MS plate (Plane/Chequered) 5mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of epoxy paints over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces exc 10 cm width or girth and applying a coat of epoxy paint complete all as specified and directed.
MADHU ENTERPRIZES
M/s S.D Construction Co
m/s ashoka enterprises
RAJENDRA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .