Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹68.3 L+₹58,602 (0.87%)Rejected-Finance 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹68.5 L+₹78,636 (1.16%)Rejected-Finance 23 2 PANCHANANTOLA ROAD KOLKATA 700041 | KOLKATA | HOWRAH | WEST BENGAL | 700041 | L3 | Rejected-Finance L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
24 Sept 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE/EC-I/EM/KMDA
Office of the Superintending Engineer, Electrical Circle-I, EM Sector, KMDA, D-Block, 2nd Floor, Unnayan Bhavan, Salt Lake-91.
Round the clock Operation, including Daily / Periodic checking, maintenance, cleaning of all electromechanical equipments and articles installed at Nazrul mancha Kolkata (16 Months).
2024_KMDA_745134_1
KMDA/EM/SE/EC-I/NIQ-09/2024-25
Open Tender
ELECTRICAL WORKS M/R
Item Rate
480 days
Nazrul Mancha
Please refer tender documents.
8 documents required · 8 mandatory
₹0
₹1.3 L
Electrical Circle-I, EM Sector, KMDA
2 Jan 2025
5 Sept 2024
27 Sept 2024
5 Sept 2024
24 Sept 2024
5 Sept 2024
11 Sept 2024
Amount
Round the clock operation & minor maintenance of Sub-station equipments and aritcles, Stage Lights, General Lights of auditorium and other places, Split type ACs of VIP Room, Artist Room, Main LT Pannel & Other Distribution Panels, Yard lights, decorative lights infront of the auditoriuma and above the main gate, Fire detection and protection equiments including MCC panel with Engine driven P/M Set, water & Drinking water pumping equipment, CC cameras, softner plant etc. at Nazrul Mancha, Kolkata with staff pattern as enclosed as per direction of the EIC.
Checking of all the Mechanical parts of fire pumps, gears of light bar, curtain bars, pullies etc. and preventive maintenance of all pump machinary as per technical specification and scope of work and direction of the EIC. (Once a Week)
Checking of all the Electrical parts including HT Panel, Transformers, Main LT Panel, Distribution panels, DBs, Stag , auditorium & surrounding lights and preventive maintenance of all fire pump machinary as per technical specification and scope of work and direction of the EIC. (Once a Week)
Supervision of all the staffs & look after the entire auditorium to ascertain the overall condition of all the electro-mechanical equipments and conveying the same to the EIC or his authorized representative and to carry out the instructions given by them within the stipulated time frame . (Once a Week)
Supply & delivery of 415V,50 Hz, 50/60 KA Manually Drawout type, 4-pole following Microprocessor based Air Circuit Breaker (Thermal Magnetic DN1) Capacity (make L&T/ABB/SCHNEIDER: 1000 A (50KA)
Supply and fixing of 240/230 volt, 50 Hz, T.P., power contactor (Make: L & T/ABB/Schneider/Simence/ GE) having contact block of the following range :95-160 A, 2 NO+2NC
Supply and delivery of MCCBs with thermal magnetic release breaking capacity Thermal release rang 125-160A, Breaking capacity Icu at 415V AC,50Hz, 50KA4pole
Supply and delivery of MCCBs with thermal magnetic release breaking capacity Thermal release rang 200-250A, Breaking capacity Icu at 415V AC,50Hz, 50KA4pole
Cleaning, Refilling, Hydro testing of Existing ABC type fire extinguisher of 6 K.G. capacity with change of damaged spares including removing from site & re-fixing after refilling
Thorough Serviceing, over hauling of Main fire pump(75 Hp, discharge 2850 LPM, Head - 70 M), Sprinkler pump(60 Hp, discharge 2400 LPM, Head - 70 M), jockey pump(12.5 Hp, discharge 180 LPM, Head - 70 M), diesel driven stand by fire pump(56 Kw, discharge 2850 LPM, Head - 75 M) inluding diesel engine( Kirlosker Make), supply and replacement of 12 V battery, repairing of battery charger, UPS, making adjustment in the pressure switch for automation including supply and replacement of CI foot valve (150 mm) complete as per direction
Programming of notifier panel, beam detector
Supply and replacement of LED luminaries : RC366B LED33-6500 of Philips or equivalent model as per direction of EIC
...Do..Do.. DN195BLED20S-3000 PSU of Philips or equivalent model as per direction of EIC
...Do..Do.. BRP322 LED 232 CW NR FG 54 XTFC L GR of Philips or equivalent model as per direction of EIC
Supply and laying of XLPE insulated 1.1 kV grade heavy duty AR Al conductor cable : 3½ C 300 Sq mm
Supply and laying of XLPE insulated 1.1 kV grade heavy duty AR Al conductor cable : 3½ C 50 Sq mm
Supply and laying of XLPE insulated 1.1 kV grade heavy duty AR Al conductor cable :4 C 16 Sq mm
SUPPLYING OF FOLLOWING THREE CORE HT POWER CABLE WITH STRANDED COMPACTCIRCULAR ALUMINIUM CONDUCTOR, CONDUCTOR SCREEN WITH EXTRUDED SEMI CONDUCTING COMPOUND, XLPE INSULATED, INSULATION SCREENING WITH EXTRUDED SEMI CONDUCTING COMPOUND IN COMBINATION WITH COPPER TAPE, CORES LAID UP, INNERSHEATH OF PVC, GALVANISED STEEL FLAT STRIP ARMOURED, AND OVERALL PVC SHEATHED CABLE CONFORMING TO IS 7098 (PART-2) 2011 WITH UP TO DATE AMENDMENTS. 11 KV 240 Sq mm UE
Laying of 11 KV …... masonry open duct as required 240 Sq mm
Supplying and making indoor cable end termination with heat srinkable jointing kit …. 240 Sq mm
Comprehensive Annual Maintenance and servicing of Air conditioning machine of following ratings : 2.0 Ton Split :
T.D.K. ENTERPRISE (BID ID -5589775)
JAYBEECO (BID ID -5594202)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .