| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹7.1 L+₹2,407 (0.34%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer |
| Sl No | Description | Qty | Unit | M/S RAHUL GUPTA L1 | ABINASHI ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm each, all as specified. | 6 | Each Leaf | 50 ₹300 | 20 ₹120 Lowest |
| 2.00 | S&F 30 mm thick plain framed panelled door shutters of 2nd class hard wood (Factory made) two panel with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed. | 3.6 | Sqm | 2,500 ₹9,000 Lowest | 2,500 ₹9,000 Lowest |
| 3.00 | S&F 35 mm thick 2nd class hard wood plain framed factory made glazed and skelton shutters open rebated and prepared to receive glass/ wire gauge etc (without sas bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for secring glass,etc size of members of shuters as specified in SSR Part-I,Section 8, clause 8.24 (a); supply and fitted to chowkhats, all as specified | 3.6 | Sqm | 2,200 ₹7,920 Lowest | 2,500 ₹9,000 |
| 4.00 | S & F factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick (stiles) with 2 4 or 6 panels design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specifications and drawings as per SSR Pt-II 2020, complete all as specified and directed. | 3.15 | Sqm | 6,200 ₹19,530 | 3,400 ₹10,710 Lowest |
| 5.00 | S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed. | 4 | Each | 150 ₹600 | 50 ₹200 Lowest |
| 6.00 | S&F butt hinges 100mm, cold rolled medium weight mild steel all as specified. | 16 | Each | 50 ₹800 | 20 ₹320 Lowest |
| 7.00 | S&F 150 mm size, extruded aluminium alloy handles, fabricated type, anodised. | 4 | Each | 50 ₹200 Lowest | 60 ₹240 |
| 8.00 | S&F 200 mm long aluminium tower bolts (ISI Marked) extruded type all as specified. | 6 | Each | 50 ₹300 Lowest | 60 ₹360 |
| 9.00 | S&F 300mm long Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed | 4 | Each | 220 ₹880 Lowest | 260 ₹1,040 |
| 10.00 | S&F 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. | 2 | Each | 300 ₹600 | 200 ₹400 Lowest |
Tender Value
₹9.6 L
EMD Value
₹19,280
Closing Date
7 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/MAINT TO CERTAIN BLDGS, INTERNAL ELECTRIFICATION, LEDISATION, REFRIGERATION AND AIR CONDITIONING EQUIPMENTS AND CONNECTED WORKS AT 156 INF BN TA UNDER AGE(I) CIF(R)
2025_MES_711778_1
AGE(I)/R-29/2025-26
Open Tender
Miscellaneous Works
Item Rate
120 days
AGE (I) CIF(R)
Class E and above and category a(i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,280
Yes
28 Aug 2025
31 May 2025
14 Jul 2025
31 May 2025
7 Jul 2025
16 Jun 2025
Amount
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each, all as specified.
S&F 30 mm thick plain framed panelled door shutters of 2nd class hard wood (Factory made) two panel with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood plain framed factory made glazed and skelton shutters open rebated and prepared to receive glass/ wire gauge etc (without sas bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for secring glass,etc size of members of shuters as specified in SSR Part-I,Section 8, clause 8.24 (a); supply and fitted to chowkhats, all as specified
S & F factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick (stiles) with 2 4 or 6 panels design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specifications and drawings as per SSR Pt-II 2020, complete all as specified and directed.
S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed.
S&F butt hinges 100mm, cold rolled medium weight mild steel all as specified.
S&F 150 mm size, extruded aluminium alloy handles, fabricated type, anodised.
S&F 200 mm long aluminium tower bolts (ISI Marked) extruded type all as specified.
S&F 300mm long Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified.
S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, gazed with putty or fixed with beads.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.50 Sqm in each pane all as specified.
Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water, M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement mixed including two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for keys scrubbing down with water, M&L Rendering 10mm thick in cement mortar 1:6 on fair aces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick in CM 1:6 complete all as specified and directed.
Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4, all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Vitrified Ceramic light shade tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm laid over screed bed 15 mm thick in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 15mm bore medium grade galvanised ISI marked with all fittings complete on walls complete all as specified and directed.
Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 20mm bore medium grade galvanised with all fittings and fixed to short length complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan and trap, (pedestal pattern) including fixing bolts, 'P' and 'S' trap and connecting to drain pipe, including white seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, anti symphonic pipe etc complete all as specified and directed.
S&F in repair Vitreous china Urinal, Half stall type, white (excluding flushing cistern, flush pipe) complete incl providing and fixing plugs, beddding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in cement; including waste pipe.
S&F in repair vitreous china wash hand basin white of bowl size 550x400mm including waste coupling and waste pipe PVC 32mm dia to be fixed over mild steel bracket complete all as specified and directed.
S&F in repair low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern low level white with inlet ball valve float ovel handle including 32mm dia PVC flushing pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair bib taps, fancy type, chromium plated, cast copper aloy ISI marked with crutch or butter fly handle high pressure screwed down for iron pipe of 15mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repairs 15mm bore angle valve chromium plated screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair fancy type Pillar tap cast copper alloy chromium plated with capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed.
S&F in repair bib taps, standard of PTMT any colour high pressure screwed for iron pipe of 15mm bore complete all as specified and directed
S&F in repair 20mm PVC ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified.
S&F grating round 125 mm size of PTMT (Minimum weight 40 gms) as in repair, complete all as specified and directed.
S&F in repair centre hole basin / Wall mixture valve, cast copper alloy fancy type 15mm brass chromium plated mixer for mixing hot & cold water screwed down for iron pipe, complete all as specified.
Dismantling water tanks (Capacity of tank exc 250 Ltr but n exc 500 Ltr) and removing from site, S&F Rotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade complete all as specified.
M&L for disconnecting existing tank, setting side for reparing cleaning and removing all scale and dirt from tanks and from mouths circulating pipes and housing in same position of capicity upto and including 500 ltrs and endrosed the word " CLEANED WITH DATE" complete all as specified.
Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by Engineer-in-Charge complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on old steel surfaces on any description not otherwise described over 10 cm width or girth including prepration of old painted surfaces, all as specified and directed.
Material & labour for one coat of cement base paint including preparation of old surface to match the shade as per colour scheme as approved by Engr-in-Charge.
M&L for two coat of oil bound distemper to old plastered surfaces including preparation of surfaces complete all as specified and directed.
S&F in repair stainless steel curtain rods 20 mm dia including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape all as directed and as approved by Engr in Charge.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets and S&F in position suspended anodised aluminium false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 605X605 mm fixed in the grid of E-grid suspended ceiling grid system duly suspended by 6 mm dia GI(upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size long and expansion hold fasteners 12.5 mm dia 40 mm long and M&L for exposed metal frame ceiling with 6 mm thick calcium silicate boards of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600X600 mm grid complete all as directed and as approved by Engr in Charge
Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
M&L for point wiring for one light/fan point controlled by one switch concealed type with PVC insulated unsheathed copper cable FRLSH 1.5 sqmm multi stranded two single copper conductor in and including suitable size PVC conduit pipe 20 mm dia complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSH continous earth wire, re-recessed mounting pressed steel GI sheet box 2 mm thick suitable for modular switch/socket of adequate size including iner and outer white cover plate of modular complete all as specified and directed for followings :-
One light/fan/5 Amp socket independent/bell controlled by one, one way switch.
One three pin socket outlet 5 Amps independent board complete
One 3 pin 5 Amp socket out let on the same board.
All as per item No 43 above but with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 1.5 Sqmm PVC insulated unsheathed continuous earth wire and connecting to common earth dolly.
S&F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed.
S&F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed.
S&F in replacement of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement of modular bell push 6A 1 module complete all as specified and directed.
M&L for replacement of Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board and 3mm thick laminated sheet top covers including 1 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:-
One light/fan/5 Amp socket independent/bell controlled by one, one way switch.
One three pin socket outlet 5 Amps independent board complete
One 3 pin 5 Amp socket out let on the same board.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size
All as per item No 50 above but with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 2.5 Sqmm PVC insulated unsheathed continuous earth wire and connecting to common earth dolly.
Supply and Fixing in replacement switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed.
Supply and Fixing in replacement socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed.
Supply and Fixing in replacement switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed.
Supply and Fixing in replacement socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and directed.
Supply and Fixing in replacement of switch socket combination 2 in one, 3 pin, 5/6 Amps, 240 volts AC flush type universal complete all as specified and directed.
Supply and Fixing in replacement of switch socket combination 2 in one, 3 pin, 5/6/16 Amps, 240 volts AC flush type universal complete all as specified and directed.
Supply and Fixing in replacement of Bell push, flush type, 5 amp 230 volts AC complete all as specified and as directed.
Supply and fixing in replacement of Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified.
Supply and fixing in replacement of ceiling rose 65X50 mm two to three terminals complete all as specified.
Supply and fixing in replacement of lamp holder insulated body with back plate batten/angle type for batten fitting complete all as specified.
Supply and Fixing in replacement of step type electronic Fan regulator, 120W single pole 240 volts complete all as specified.
Supply and Fixing in replacement of modular Fan regulator electronic step type heavy duty 2 module 230 volts120W complete all as specified and as directed.
Supply & Fix Ultra modern recess mounting luminaire with high performonging LEDs suitable for mounting with armstrong/grid ceiling 2'x2' LED 36W 6500K or 3000K and connecting up with three core copper conductor cable with Ceiling including taking down old. Make : Havells cat part No. LHEBAEP7IW1W036 94051100 or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixing in replacement of Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver wall mounted LED Batten 20 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.Make as per Havells Cat Part No. LHEXAWP7UN1W020 or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixing in replacement of Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver wall mounted LED Batten 10 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.Make as per Havells Cat Part No. LHEXAXPNIN1W010 or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of 3 pin plug top, AC 230 V, 16 Amps complete all as specified and directed
S&F in replacement of 3 pin plug top, AC 230 V, 5/6 Amps complete all as specified and directed
Supply in replacement of hylam sheet cover 3 mm thick for fixing of switch,socket,regulator,etc of following size on existing box complete all as specified and directed.
(a) Size of 4 x 4 inches
(b) Size of 7 x 4 inches
S&F in replacement of PVC conduit medium grade with all fittings,ISI marked,of following size complete all as specified and directed.
(a) Size of 20 mm dia
(b) Size of 25 mm dia
S&F in replacement of PVC casing & capping with all fittings,ISI marked,of following size complete all as specified and directed.
(a) Size of 20 x 12 mm
(b) Size of 25 x 16 mm
S&F in replacement of PVC switch boards, closed recessed suitable for surfaces of following sizes with all fittings complete all as specified and directed.
(a) Size of 4 x 4 inches
(b) Size of 4 x 7 inches
(c) Size of 8 x 6 inches
Supply and fixing in replacement LED Bulbs white /warm white (as per demand) in colour of 9/10 Watt,B-22 base Cap
Supply and fixing in replacement of LED lights 20 watt recess mounted square type Ceiling cutout Including connection with 1.5 sqmm PVC insulated copper wire complete. Make : Havells Cat Part LHEBLDP7IN1W020 or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixing in replacement of LED lights 10 watt recess mounted Round type Ceiling cutout including connection with 1.5 sqmm PVC insulated copper wire complete. Make : Havells Cat Part No. LHEBLDP7IN1W010 or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixing in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make:- Havells cat HEXAFT10WLED857SSYMBOPC) or equivalent cat part of make as specified in list of make here-in-after.
M&L in replacement of two single core sub main wiring 4.0 Sqmm multi-strand PVC insulated copper conductor FRLSH cable including PVC insulated copper conductor cable of size 4.0 Sqmm as cotinuous earth wire connecting to common earth including in 20mm PVC rigid conduit including connections of cable with MCBs or bus bars complete all as specified and directed. (Note: 2x4 + 1x4.00 sqmm copper coductor with PVC Conduit shall be measured as one unit).
Supply and fixing in replacement of sheet metal enclosure for MCB DB 2 way Single door SPN, complete all as specified.
Supply and fixing in replacement of sheet metal enclosure for MCB DB 4 way Single door SPN, complete all as specified.
Supply and fixing in replacement of Sheet metal enclosure MCB DB 4 way double door SPN, complete all as specified.
Supply and fixing in Replacement of Sheet metal enclosure MCB DB 8 way double door SPN, complete all as specified.
Supply and fixing in replacement of MCB single pole 6 to 32 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 40 to 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. (Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only (ii) Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule. (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v)Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR/ bill as follows: (a) For first day Rs 200 (b) For second day Rs 300 and (c) For next every day Rs 500
All as per serial item No.93.00 here-in-before but for exhaust fan of size 300mm/450mm sweep
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the ceiling fan (1200/1400mm sweep) armature/motor with new super enamelled copper wire of existing gauge including supply and fixing necessary E class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
M&L for rewinding of heavy duty exhaust fan motor of 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor and testing including removing burnt out copper winding wire from fan motor complete all as specified and directed.
All as per Item No.96.00 above but 450mm.
Supply only gun metal bush suitable for ceiling fan/Exhaust fan/Air circulator fan /wall mounted fan of any sweep/type of any size (Make - TATA/MSP).
Supply only Ball bearing No.6201/6202/6203/6204 for ceiling fan (Make - TATA/SKF /NBC/NRB).
Supply only fan condensor 2.5 mfd,230 volt,AC 50Hz confirming to IS 1709 for ceiling fan,exhaust fan,wall mounted fan and pedestal fan (Make - USHA/UNIVERSAL/Havells)
Supply only fan condensor 3.15 mfd (Make - USHA/UNIVERSAL/Havells)
Supply & fixing Electronic fan regulator stepped type with five step ,two module, 100Watt 240 volts complete all as directed.
Supply only flexible multi stranded copper wire three core of size 0.75 sqmm all as specified and as directed.
Supply only PVC connector 4 way 6Amp with connection screws nuts etc complete all as directed.
Supply only PVC canopy set of two pieces for ceiling fans of any size complete all as directed.
Supply only rubber reel with nuts bolts clamp and washers of suitable size for ceiling fan complete all as specified and as directed.
Supply only down rod made of MS pipe medium grade 15mm bore of 900mm long including drilling hole both ends & making slot in one end for fixing of ceiling fan of any sweep/type including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 35 Ltrs comprising of the following :- (a) Inspection, taking down , opening or dismantling, de-scaling,brushing and thoroughly cleaning the storage tank up to the satisfaction of the Engineer-in-charge. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point. (d)Checking,and re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydro chloric acid or clear pedette solution. (f)Checking of indicator lamp for it serviceability . (g)Re-assembling the Geyser, re-install and testing complete. (h) The rate for above ietm are deemed to include for transportation of geyser to the work shop as approved by Engr-in-Charge for necessary repairs and testing of Geyser at workshop. (j) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (k)Repair works of geysers should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR/ bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item no. 108 & 109
All as per item No.108 here-in-above but Geysers of capacity 25 ltrs .
Supply only thermostat(Adjustable type) of Rod/stem Type EST-11EM,20A resistive , 250 Volt, opening on temperature rise of approved make and having ISI mark all as specified.
Supply only steel inner tank suitable for storage type water heater (geyser) 25 litre capacity.
Supply only steel inner tank suitable for storage type water heater (geyser) 35 litre capacity.
Supply only steel siphon geyser assembly 6/9 hole suitable for 35 ltr capacity geysers any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket all as specified and as directed
All as per item No.113 here-in-above but siphon assembly suitable for 25 ltrs capaity Geysers.
Supply only heating elements of capacity 1.5 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartige type),ISI marked all as specified and as directed.
All as per item No.115 here-in-above but of capacity 2 KW AC 240 volts
Supply only glass wool for geyser 25/35 litre capacity complete all as specified and as directed.
Supply only gasket of thickness 5mm for geyser assembly of 09 holes/09 holes complete all as specified and as directed.
Supply only geyser indicator pilot lamps(red and green lamps) with wiring round/square/rectangle suitable for geysers of any type.
Supply & fixing PVC connection pipe 15 mm dia, 450mm long with end nuts and washer, suitable for cold/hot water outlet of geyser complete all as specified and directed.
Supply & fixing PVC connection pipe 15 mm dia, 600mm long with end nuts and washer, suitable for cold/hot water outlet of geyser complete all as specified and directed.
Supply only safety valve suitable for 25 Ltr/35 Ltr geyser all as specified and as directed.
Supply only non return valve 15mm bore as in replacement of old one and connection and testing complete all as specified and as directed.
Supply and fixing of plug top 3 pin 16 Amps,240 volts.
Supply only flexible multi stranded copper wire three core of size 2.5 sqmm all as specified and as directed.
Supply only fastner mild steel 100/150/200mm long complete all as directed.
Supply and fix in replacement Oil Room Heater 2900 Watt Suitable for 11 Fin,weight 18 Kg with fan complete all as specified and as directed.of Havells Model No OFR 11 Fin or equivalent /Bajaj/Morphy.
Supply and fix in replacement of Single pole and neutral enclosure(1P+N+E ) with a two pin and earth plug and socket complete with one double pole 20A MCB all as directed.
Servicing and Replacment of unservicable parts of Refrigerator/Deep freezer/water cooler of any capacity complete with chemical solution to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, including tracing out the leaking of condenser/evaporator filling the holes by using gas welding, complete with refilling of refrigerant R12/R11/R134a(whichever is applicable) etc complete all as specified and as directed. (Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only
Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed.
Supply only starting capacitor 40/60 MFD Make: EPCOS/Sycaparisto/ASIAN
Supply only Running capacitor 10 to 15 MFD Make: EPCOS/Sycaparisto/ASIAN
Supply only over load protector relay (Suitable for any make / model of compressor all as approved by Engineer-in-Charge (Make : Kilxen/KCL/ Electrica)
Supply only AC electric condensor motor of 1/35 HP , SP 230 Volts, complete with blade all as specified and directed. (Make : KSB/Beacon/ Kirlosker)
Supply and charging the gas refrigerant R-12/R-134a (freon) suitable for reezer/Refrigerator including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 Sqmm aluminium Stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 10 Sqmm aluminium Stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
Supply and fix in replacement voltage stabilizer 2 KVA suitable for window/split type AC/ Deep freezer/ Refrigerator working on AC 240 V,50Hz single phase all as specified and as directed.
Supply and fixing new compressor unit for 310 Ltr capacity refrigerator including taking down existing old/unserviceable conpressor unit from refrigerator. Make: Whirlpool/VOLTAS/LG/GODREJ
Supply only blower fan motor suitable for refrigerator of cap up to 310 Ltr cap.
Supply only thermostat switch with defrosting arrangement suitable for Refrigerator of capacity up to 310 Ltrs
Supply only starting relay suitable for refrigerator of cap up to 310 Ltr cap.
Supply only magnetised door lock rubber strip gasket set complete for refrigerator of cap up to 310 Ltrs
Supply only freezer for refrigerator for 280/310 Ltrs capacity
Supply only electric bulb SP 230 volts screw/Pin type with base all as directed
Supply only over load protection for refrigerator of capacity up to 310 ltr.
Supply only Freezer door with hinges for refrigerator of cap 280 ltr/310 Ltrs (As per sample)
Supply and fix new compressor sealed unit for deep freezer capacity up to 320 Ltrs obtained from the factory outlet /authorised dealer alongwith test certificate and with one year guarantee card and testing on full load complete all as specified and directed by Engineer in charge. Make: Blue star / Emerson/Tecumesh/LG/Kirloskar/Whirlpool. Note : Gas charging and gas shall be paid and measured separately under appropriate item of this sch
Supply and fix blower motor 1/9 HP 230 volt single phase Make: Unitech/Universal.
Supply and fix Thermostat for Deep Freezer upto 320 Ltrs capacity.
suopply only starting relay suitable for deep freezer upto capacity 500Litres.
Supply only overload protector device for deep freezer upto 500 litres capacity.
Supply only Running capacitor for deep freezer upto 400 Litres capacity.
Supply only Starting capacitor for deep freezer upto 400 Litres capacity.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 27,632.00 during AOC Note:- Tenderers shall not quote for this Schedule
ABINASHI ENTERPRISES (BID ID -3343348)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .