Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.5 L
EMD Value
₹4,500
Closing Date
2 Mar 2026, 6:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER REW ANANTNAG
OFFICE OF THE EXECUTIVE ENGINEER REW ANANTNAG
INTERNAL ELECTRIFICATION OF BDO ACCOMMODATION BLOCK VERINAG
2026_RDPR_304435_15
ENIT227of2025-26
Open Tender
Civil Works
Percentage
30 days
ANANTNAG
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
OFFICE OF THE EXECUTIVE ENGINEER REW ANANTNAG
₹4,500
3 Mar 2026
25 Feb 2026
3 Mar 2026
25 Feb 2026
2 Mar 2026
25 Feb 2026
Wiring for light point(22)/ fan point(5)/exhaust fan (3) point with 1.5.sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in existing surface /recessed medium class PVC conduit,with modular switch (Anchor roma urban /eq.make), base plate,cover plate,suitable modular GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable etc as required (Havells /Legrand/roma urban/Eq.make as par ISI Standard Note The GI boxes can be of different sizes of Modulues to hold the Modular Boxes and Modular Switches for lights/fans/exhaust fans and are included in the point rate
Supply, fixing,drawing testing and commissioning of 3x2.5 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed 2 medium class PVC conduit for circuit wiring of Lighting /Inverter Note This includes Three wires (Phase, Neutral and earth) and 1 Ckt meter is equivalent to 3 meters
Supply,fixing, drawing testing and commissioning of 3x4 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make), single core cable in existing surface /recessed 3 medium class PVC conduit for Circuit Wiring of Heating Points Note This includes Three wires (Phase, Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply,fixing, drawing testing and commissioning of 3x6 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make), single core cable in existing surface /recessed 3 medium class PVC conduit For AC Points 4 Note This includes Three wires (Phase, Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply of fixing of 25/20 mm size PVC condute along with accessories(bends,sockets,iron staples/saddles/screws,pvc fastener etc) in surface /recess include in cutting the wall and making good the same by cement sand and paint in case of recessed/Surface condute as required for Walls/slab
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 16/32 amp /230 V AC modular socket and 16/32 amp modular switch (Anchor Ro urban/SSK NV/Havells/Eq.make)
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess Including providing and fixing of 3 pin 5/6 amp/230 V AC modular socket and 5/6 amp modular switch (Anchor Ro urban/SSK NV/Havells/Eq.make)
Supply installation testing and commissioning of 1200 mm dia sweep Ceilng fan of standard make
Supply installation testing and commissioning of 900 mm dia sweepCeiling fan of standard make
Supply of fixing of 6 amp /230 V AC fan dimmer step type 2 module with cover plateAnchor Ro urban/SSK NV/Havells /Eq.make.
SITC of 150-200 mm dia Sweep Exhaust Fan with ceiling rose of standard make
S/F testing nd comm..of recessed/surface mounted 12 watt LED down lighters SMD type 11 system Luman efficacy >= 100<120 Im/watt Philips /havalles /bajaj/Crompton make of eq. standards
SITC of 20 watt LED bulk lights of standard make (Complete Job)
Suppling and fixing of 6(4+18)/24 way (4 quadrant) horizontal type Three pole and neutral sheet steel,MCB distribution board,415 V,On surface /recess, complet with neutral bus bar,earth bar,din bar interconnection,powder painted including earthing etc.as required.(But with out mcb/ Rccb/Isolator):-Hager /Legrand /ssk/equt.standard
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 63 Amp TPN MCB
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 6-25 Amp SP MC
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 32-63 Amp DP MCB
Supply,laying overhead or underground, testing and commissioning of 16 sqmm Four Core Al Armoured cable in conduit of standards make
SITC of 100 amp Tap off Box with Al bus bars including Providing of 5x10sqmm cu wire( mini25mtr) from Mains DB to Tap off box to be installed outside the building Job
Earthing with Gl earth Pipe 2.15 metre long,40 mm dia including and providing charcoal/coke/salt as required along with 10 SWG GI Wire /25X3 mm GI Strp upto the nearest point of earth to be supplied/drawn from Main Power distribution Board/Tap off box and connecting the same (Complete Job) as per the directions of engineer incharge
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_988903.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .