Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 CrAdmitted-Finance | ₹38.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹41.3 CrAdmitted-Finance 301 306 PANORAMA COMPLEX R C DUTT ROAD VADODARA VADODARA GUJARAT 390007 | VADODARA | GUJARAT | 390007 | ₹41.3 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical EN 62 7TH FLOOR SALTLAKE CITY KOLKATA SECTOR V WEST BENGAL 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | - | - | Rejected-Technical Bidder does not meet the techno commercial eligibility criteria as per NIT and SBD |
| Sl No | Description | Qty | Unit | Sterlite Power Transmission Limited L1 | Apar Industries Limited L2 |
|---|---|---|---|---|---|
| 1.00HTLS Re-conductoring of Transmission line including Design, Manufacturing & Supply of Carbon Fibre Composite Core Type HTLS Conductor, Insulator, Hardware fittings and Accessories for 132 kV D/C Hiranagar-Kathua TL from existing ACSR Panther to Carbon Fibre Composite Core Type HTLS Conductor | |||||
| 1.01Schedule Of Rates For Supply Works | |||||
| 1.02 | Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 200 | Kms | - | - |
| 1.03 | Dead End fittings for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 934 | Nos | - | - |
| 1.04 | Mid Span Compression Joint fittings for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 117 | Nos | - | - |
| 1.05 | Repair Sleeve for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 35 | Nos | - | - |
| 1.06 | Single Suspension Pilot fitting for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 132 | Nos | - | - |
| 1.07 | Vibration Damper suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 2,232 | Nos | - | - |
| 1.08 | 70 KN Long Rod Composite polymer Insulator- single suspension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 90 | Nos | - | - |
| 1.09 | 70 KN Long Rod Composite polymer Insulator- Double suspension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther) | 84 | Nos | - | - |
Tender Value
₹37.5 Cr
EMD Value
₹75 L
Closing Date
27 Jan 2020, 4:00 pmClosed
Executive Engineer TLMD-II JKPTCL Gladni Jammu
Executive Engineer TLMD-II JKPTCL Gladni Jammu
HTLS reconductoring of 132KV D C Hiranagar Kathua Transmission Line and Twinning of 220KV Main and Reserve Busbar from Double ACSR Zebra to Double HTLS Conductor
2019_PDD_87209_1
TLMD-II/Gld/J/04 of 2019-20 dated 25-11-2019
Open Tender
Electrical Works
365 days
Jammu
As per NIT and SBD
3 documents required · 3 mandatory
₹10,000
Executive Engineer TLMD-II JKPTCL Jammu
₹75 L
Office of Chief Engineer Transmission JKPTCL Jammu
14 Mar 2020
2 Dec 2019
3 Feb 2020
3 Dec 2019
27 Jan 2020
23 Dec 2019
6 Dec 2019 - 13 Dec 2019
16 Dec 2019
Amount
HTLS Re-conductoring of Transmission line including Design, Manufacturing & Supply of Carbon Fibre Composite Core Type HTLS Conductor, Insulator, Hardware fittings and Accessories for 132 kV D/C Hiranagar-Kathua TL from existing ACSR Panther to Carbon Fibre Composite Core Type HTLS Conductor
Schedule Of Rates For Supply Works
Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
Dead End fittings for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
Mid Span Compression Joint fittings for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
Repair Sleeve for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
Single Suspension Pilot fitting for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
Vibration Damper suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
70 KN Long Rod Composite polymer Insulator- single suspension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
70 KN Long Rod Composite polymer Insulator- Double suspension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
70 KN Long Rod Composite polymer Insulator- Single suspension Piolet fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
120 KN Long Rod Composite polymer Insulator- single Tension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
120 KN Long Rod Composite polymer Insulator- Double suspension fitting suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
120KN Long Rod Composite polymer Insulator for Gantry End suitable for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Panther)
70KN Single Suspension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
70KN Double Suspension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
120KN Single Tension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
120KN Double Tension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
Schedule Of Rates For Erection,Testing & Commissioning Works
Erection of new carbon fibre composite core type HTLS Conductor along with fittings & accessories and Dismantling of existing Line Conductor and write- back of the de-erected material to the Divisional Stores
Twining of 220kV Bus Bar ( Main and Reserve) from Double ACSR Zebra to Double HTLS Conductor (Carbon Fibre Composite core equivalent to ACSR Zebra) of the existing 220/132/66kV Hiranagar Substation
Schedule Of Rates For Supply Works
Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Zebra)
120KN Single Tension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
70KN Single Suspension Fitting with clamps suitable for Twin Carbon Fibre Composite Core type HTLS Conductor ( equivalent to ACSR Zebra)
Twin T Clamp for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Zebra) to Single ACSR Zebra
Twin T Clamp for Carbon Fibre Composite Core type HTLS Conductor (equivalent to ACSR Zebra) to Twin ACSR Zebra
120 KN Long Rod Composite polymer Insulator, Size 20x1305 (mm), Min.Creepage Distance 4495mm, Mechanical strength of Insulator string alongwith Hardware fittings 120kN
120 KN Long Rod Composite polymer Insulator, Size 20x1305 (mm), Min.Creepage Distance 4495mm, Mechanical strength of Insulator string alongwith Hardware fittings 70kN
Spacer for Twin Carbon Fibre Composite Core type HTLS Conductor (Equivalent to Zebra)
PG Clamps for Carbon Fibre Composite Core type HTLS Conductor (equivalent to Zebra)
Schedule Of Rates For Erection,Testing & Commissioning Works
Erection of new carbon fibre composite core type HTLS Conductor along with fittings & accessories and Dismantling of existing Bus Conductor (Main and Reserve) and write- back of the de-erected material to the Divisional Stores
Apar Industries Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.61 MB
SBD.pdf
Tender Documents • 28.36 MB
CEAGuidelines.pdf
Additional Documents • 3.59 MB
BOQ_163068.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid