Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC NATIONAL HIGHWAY BYE PASS CROSSING ATHWAJAN SRINAGAR 191101 KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹2.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.8 Cr+₹58.4 L (26.9%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | ₹2.8 Cr+₹58.4 L (26.9%) | L2 | Rejected-Finance BEING L2 |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
3 Jul 2021, 6:00 pmClosed
CE AF Udhampur
CE AF Udhampur
PROVN OF OTM ACCN AND ALLIED WORKS SERVICES AT AF STN SRINAGAR CEAFU-16/2019-20
2019_MES_284080_1
CEAFU-16/2019-20
Open Tender
Civil Works
Lump-sum
549 days
srinagar
Refer as per NIT and Tender Documents
10 documents required · 10 mandatory
₹2,000
GE P AF SRINAGAR
₹3.0 L
Yes
29 Jul 2021
12 Feb 2021
5 Jul 2021
12 Feb 2021
3 Jul 2021
21 Jun 2021
12 Feb 2021 - 5 Mar 2021
Amount
Total amount of Sch 'A' PART-I ( BUILDING WORK)
Total amount of Sch 'A' PART-II (SEC-I) (ROAD/HARDSTANDING /CULVERT/CAUSE WAY WORK)
Total amount of Sch 'A' PART-III(SEC-I)(SEWAGE DISPOSAL WORK)
Sch 'A' PART-III (SEC-II) (SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of Soakage well, of internal size 3.6m dia and 3m deep ( brick masonry construction) complete all as specified and shown on drawings .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2
Construction of septic tank 50 users, Brick construction complete all as specified and as directed and shown on drawing. .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2
Total amount of Sch 'A' part-IV (AREA DRAINAGE WORK)
Total amount of Sch 'A' PART-VI (Sec-I) ( INTERNAL WATER SUPPLY AND PLUMBING WORK)
Sch 'A' PART-VI (SEC-II) ( INTERNAL WATER SUPPLY AND PLUMBING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F CP central hole mixer for mixing hot and cold water including comlete accessories all as specified and as directed
S&F CP urinal spreader for urinal complete all as speciefied and as directed
S&F CP push type angle volve for urinal complete all as speciefied and as directed
S&F CP health faucet with pvc tubing 1 Mitre complete all as speciefied and as directed
Total amount of Sch 'A' PART-VII ( Section-I) (EXTERNAL WATER SUPPLY WORK)
SCHEDULE `A' PART-VII (Sec-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Cutting existing steel tubing for alteration or additions, 150 /200 mm bore GI tubing complete all as specified and directed by Engineer-in-Charge.( Each cut measured).
Material and labour cast iron flanged sluice valve of class 1.0 PN complete with brass spindle with H/W, nuts, bolts, gaskets of size 80 mm dia complete all as specified and directed .
Material and labour cast iron air release valve single flanged double chamber complete with nuts, bolts and gasket, confirming to IS-14845 of size 80 mm dia complete all as specified and as directed.
Material and labour for valve chamber (0.9M x 0.9M x 1.2M) with brick masonary(1:3) cement mortar valve chamber, PCC foundation, plastering and necessary excavation and earth work in any type of soil, MS sheet cover 5 mm thickness along with angle iron frame of size (40 x 40 x 6) mm with locking arrangement & necessary fixing materials like hinges, nut/bolts etc and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc complete all as specified and directed .
Material and labour for valve chamber (0.6M x 0.6M x 0.9M) with brick masonary(1:3) cement mortar valve chamber, PCC foundation, plastering and necessary excavation and earth work in any type of soil, MS sheet cover 5mm thickness along with angle iron frame of size (40 x 40 x 6) mm with locking arrangement & necessary fixing materials like hinges, nut/bolts etc and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc all as specified and directed.
Total amount of Sch 'A' PART-VIII( Section-I) (HOT WATER SUPPLY WORK)
SCHEDULE `A' PART-VIII (Sec-II) (HOT WATER SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and installation of water heater Storage type of capacity 25 litres, electric supplied 5 star rating complete all as specified and as directed.
Total amount of Sch 'A' -IX (Section-I) (EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK)
Sch 'A' Part-IX (Section-II)( EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material and labour for cable route indicators, made of 15 cm dia 12 mm thick CI sheet , engraved with type, size and voltage of cable and painted, embedded in PCC block (1:2:4) type B-1 of size 200x150x150mm fixed in ground angle iron of size 40x40x6mm at 1 mtr height above ground level and 0.8 mtr under ground and a hook of suitable size welded at bottom of angle to hook the cable indicating the route of cable complete all as specified and as directed.
Supply and fixing New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LED as light source 1 x 70 Watt, LED , IP 65/66 Protection type , optics General Spread type Complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor of suitable size long with suitable size mounting bracket complete all as specified and as directed.
Supply and fix MS box (Kiosk) weather proof made out of 16 SWG MS sheet of size 30cmx23cmx20cm including 4 strip Three phase bus bar of aluminium strip with neutral link 32 A rating mounted on insulators of inflammable material and fixed with one Nos MCB SP 240 volts, 6 Amps for controlling street light fittings to be mounted on poles at easily accessible height for repairing/replacement from ground with flat iron clamps 40 X 6mm and shutter to be opended/closed vertically with locking system complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.0) mm thick buried directly into ground vertically to depth not less than 4metre below normal ground level with top edge of earth plate at a depth not less than 3.25 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earth lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps upto Machinary or equipment to be Earthed and watering pipe of bore 20 mm dia GI medium grade from bottom of plate to Ground level, including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate including form work cement mortar including MS Pit cover 10mm Thick with frame necessary excavation and earth work in any type of soil, including Testing of Earthing on completion for desired result all as specified. Note: (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. (ii) 4 mm dia earth lead wire & GI protection pipe up to 7.5 metre is deemed to be included in the unit rate quoted against this item .
Earthing complete with GI earth plate electrode of size (600 x 600 x 6.0) mm thick buried directly into ground vertically to depth not less than 4 mtr below normal ground level with top edge of earth plate at a depth not less than 3.25 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to copper strip of size 32 x 6 mm by means of lugs, bolts, nuts, washer, check nuts of GI all as shown in Electrical plate No. 3, strip protected by dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps upto Machinary or equipment to be Earthed and watering pipe of bore 20 mm dia GI medium grade from plate bottom end to Ground level including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate including MS Pit cover 10mm Thick with frame necessary excavation and earth work in any type of soil, including Testing of Earthing on completion for desired result all as specified and directed. Note: (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. (ii) Copper strip & GI protection pipe up to 7.5 metre is deemed to be included in the unit rate quoted against this item .
Total amount of Sch 'A' PART-X(Sec-I) (AIR CONDITIONING SYSTEM WORKS)
SCHEDULE `A' PART-X ( AIR CONDITIONING SYSTEM WORKS ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing of 32 Amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB all as specified and directed.
Supply and fix outdoor unit mounting brackets Factory made heavy duty made out of MS sheet bent to shape duly slotted for adjustment duly painted with synthetic enamel paint over a coat of red oxide primer complete with stainless steel dash/hole fastener's of adequate length for fixing the bracket to wall for mounting of Out Door unit complete all as specified and directed (Set of Two).
Material and labour for fabricating and fixing of a snow /rain protection cover / shed for outdoor unit made out of MS equal angle frame work of size 50cm x 120cm made out of 25x25x5 mm angle 5 cm height in front of 15 cm height in back side with one supporting member in centre of the frame with heavy duty acrylic sheet of suitable size and thickness complete with GI hooks/nuts and grouted into the wall and making good the disturbed surface including painting the MS work with synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete ISI marked complete all as specified and as directed.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete ISI marked complete all as specified and directed.
Total amount of Sch 'A' PART-XI (Section-I) (INTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-XI (Section-II) (INTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S & F LED integrated batten T5 of 18 Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated type complete all as specified and as directed..
S & F LED integrated batten T5 of 2 x 18 Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated type complete all as specified and as directed..
S&F distribution board vertical load line type iron clad , double door with IP-43 IK -09 - protection suitable for MCCB TPN as incommer and MCB SP as outgoing , 415 Volts 3 phase 50 C/s 4 way complete with appropriate size copper bus bar and neutral link complete with one MCCB TPN , 415 volts 63 amps rating with rupturing cap 10 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and as directed.
LED Street light of 40 Watt , IP66 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass for protection including connection electrically with twin core flexible cable with and including street light bracket made out of 43 mm dia GI tubing medium grade 1.2 mtr long ,bent to shape, with all necessary fittings i.e nuts,bolts, clamps made out of flat iron 50X6mm -02 nos.and necessary electric connection complete all as specified and as directed by Engr-in-Charge.
S &F Surface mounted LED luminaire for mirror lighting 10 watt Complete with lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated sheathed with flexible copper conductor of size 0.50 sqmm all as required.
S &F Lamp holder insulated body with back plate ISI marked for batten fittings including LED 5 Watt complete all as specified and as directed.
S&F ceiling fan 5 star rated (as per BEE recommendation) 1200mm sweep suitable to work on single phase 230 volts 50 Hz AC supply complete with electronic regulator step type hum free suitable to control speed of fan 0 to 100 % connecting electrically to ceiling rose or connector block using PVC insulated and over all sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor complete all as required at site complete all as specified and as directed .
S & F heavy duty exhaust fan (as per BEE recommendation) 230mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as required at site or directed by Engr-in-Charge
S & F heavy duty exhaust fan (as per BEE recommendation) 380mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as required at site or directed by Engr-in-Charge
MCB single pole & neutral 240 volts 6 to 32 amps,with rupturing capacity 10 KA, ISI Marked complete all as specified and as directed. .
MCB single pole 240 volts 6 to 32 amps, with rupturing capacity 10 KA, ISI Marked complete all as specified and as directed.
Total amount of Sch 'A' part-XII (SITE CLEARANCE , EXCAVATION AND EARTH WORK)
M/S ZAHOOR AHMAD KHAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .