Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
5 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
AGE (I) AF Manauri
AGE (I) AF Manauri
REPAIR/MAINT/SERVICING MISC SUMMER APPLAINCES AT 24 ED MANAURI
2026_MES_798750_1
8000/81/E8
Open Tender
Civil Works
Item Rate
270 days
Manauri Prayagraj
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Manauri
₹18,000
Yes
14 Nov 2026
14 Nov 2026
7 Dec 2026
14 Nov 2026
5 Dec 2026
28 Nov 2026
14 Nov 2026 - 23 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation and testing Air cooled Inverter based split AC 1.5 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode) Air conditoner will have following conditons :-
(a) Refrigerant - R-410 a/R-32
(b) EER-5 Star Rating
(c) Tonnage - 1.5 TR
(d) Indoor Noise level - Not more than 40 Db
(e) Filter - As recommended by OEM
(f) Remote As recommended by OEM including 02 Nos remote bty
(g) Temp display, turbo mode and auto swing facility
All specification will be as per IS-1391 (Part 2) and latest amendments | 4 | Each | - | - |
| 2 | Supply, installation and testing Air Cooled Inverter based tower AC of vertical type air conditioner capacity 4.00 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode), 415 volts, 50 Hz, 3 phase, turbo cool, wide angle, Specific Refrigerant which is suitable for tower AC, Noise level not more than 40Db, Temp display,power full air flow 2 way swing, Anti corrosive gold fins in indoor units, blower motor, PCB kit, remote control with suitable battery, communication cable from out door unit to indoor unit including with all accessories as per OEM specification complete all as specified and directed including taking down old unserviceable indoor/outdoor unit capacity 4.0 TR. Note :- (a) contractor should be submit the guarntee period of indoor unit and OEM purchase voucher with test certificate to department. | 2 | Each | - | - |
| 4 | Supply, installation,commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 Ltrs and nominal cooling capacity 40 Ltrs complete with all accessories all as directed by Engr-in-Charge. | 2 | Each | - | - |
| 5 | Supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180V to 250V with voltage stabilzer at 230V with Digital display, accuracy of (+) 2.5% and capacity 4 KVA complete all as specified and as directed by Engineer-in-charge | 4 | Each | - | - |
| 6 | Taking down old unsv sub main wiring and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 4.00 Sqmm 1100 volts grade drawn PVC conduit of size 19/20 mm (ISI marked) including PVC accessories (conduit on wall complete including making good to disturbed surface etc)complete etc including one run of 4.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 4.00 Sqmm cable and one run of 6.00Sqmm earth wire & 20 mm PVC conduit shall be measured as one unit length. | 160 | RM | - | - |
| 7 | Supply and fixing Tower Air Conditioner outdoor Mounting stand (wall/Flour Mounting), MS factory made stand powder coated (as per sample) including zebra bolts & washers, including grouting in wall/Flour. Building works, cement works, nut bolts and painting extra complete all as specified and directed. | 3 | Each | - | - |
| 8 | Supply and fixing in replacement industrial Switch socket combination in sheet enclosure 32 Amp three phase (3P+N+E) 415 volts, IP 30 protecion, ISI marked, including with MCB four pole 32 Amp, top plug in existing specification including making all connection complete all as specified and directed. | 3 | Each | - | - |
| 9 | Taking down old unsv sub main wiring and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC conduit of size 19/20 mm (ISI marked) including PVC accessories (conduit on wall complete including making good to disturbed surface etc)complete etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6.00 Sqmm cable and one run of 6.00Sqmm earth wire & 20 mm PVC conduit shall be measured as one unit length. | 90 | RM | - | - |
| 10 | Supply and fixing sheet metal enclosure with socket and plug top single pole and neutral enclosure with two pin and earth plug and socket complete with one MCB 20-25 Amp 'c' series single pole complete with connection all as directed by Engr-in-Charge. | 7 | Each | - | - |
| 11 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as directed by Engineer-in-Charge. | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TENDER81.pdf
Tender Documents • 0.80 MB
BOQ_896069.xls
BOQ • 0.32 MB
PS81.pdf
Additional Documents • 0.27 MB
ListofMakes81.pdf
Additional Documents • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .