Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86,044.72Accepted-Finance | ₹86,044.72 | L1 | Accepted-Finance First Lowest |
| 2 | L2₹86,602.56+₹557.84 (0.65%)Accepted-Finance | ₹86,602.56+₹557.84 (0.65%) | L2 | Accepted-Finance Second Lowest |
| 3 | L3₹87,620.90+₹1,576.18 (1.83%)Accepted-Finance | ₹87,620.90+₹1,576.18 (1.83%) | L3 | Accepted-Finance Third Lowest |
| 4 | L4₹88,680.25+₹2,635.53 (3.06%)Accepted-Finance | ₹88,680.25+₹2,635.53 (3.06%) | L4 | Accepted-Finance Fourth Lowest |
| Sl No | Description | Qty | Unit | AZHAGAPPAN L4 | ALLWIN COOL SERVICE L1 | SADASIVAN ENTERPRISES L2 | SRI GANESH REFRIGERATION L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Installation of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of | 1 | No | 47,100 ₹47,100 | 46,130 ₹46,130 Lowest | 46,150 ₹46,150 | 46,150 ₹46,150 |
| 1.01Cooling Dehumidifying Air Circulating Filtering The installation works for the above split type AC units includes the following. 1.Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit. (Carrier/Voltas/O General) (Blood Bank ) | |||||||
| 2.00 | Supply and Installation of 5KVA Capacity Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 1 | No | 4,700 ₹4,700 | 4,600 ₹4,600 Lowest | 4,645 ₹4,645 | 4,700 ₹4,700 |
| 3.00 | Supply and fixing of MS stand for fixing the Outdoor unit. | 1 | No | 979 ₹979 | 970 ₹970 Lowest | 975 ₹975 | 1,000 ₹1,000 |
| 4.00 | Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) | 3 | Mtrs | 1,050 ₹3,150 | 978 ₹2,934 Lowest | 980 ₹2,940 | 1,000 ₹3,000 |
| 5.00 | Supply and fixing of water drain pipe line (1" PVC PIPE) | 20 | Mtrs | 70 ₹1,400 | 58 ₹1,160 Lowest | 60 ₹1,200 | 70 ₹1,400 |
| 6.00 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. | 32 | Mtrs | 260 ₹8,320 | 252 ₹8,064 Lowest | 255 ₹8,160 | 260 ₹8,320 |
| 7.00 | Supply and fixing of 32 Amps DP MCB with sheet steel enclosure (Higher end) in flush with wall and making good of the concealed portion with earth connection. (The DP MCB & Enclosure should be of (Higher end) | 3 | Nos | 1,340 ₹4,020 | 1,300 ₹3,900 Lowest | 1,339 ₹4,017 | 1,400 ₹4,200 |
| 8.00 | Supply and fixing of Single Pole 6A to 32A, 10KAin Existing DB including labour charges. | 2 | Nos | 180 ₹360 | 160 ₹320 Lowest | 170 ₹340 | 180 ₹360 |
| 9.00 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall/floor/ground for earth connection. | 9 | Mtrs | 200 ₹1,800 | 180 ₹1,620 Lowest | 190 ₹1,710 | 200 ₹1,800 |
Tender Value
₹86,620
Closing Date
18 Sept 2026, 10:00 amClosed
Executive Engineer (Elec),PWD.,Electrical Division
OFFICE OF THE EXECUTIVE ENGINEER (ELECTRICAL), PWD., Electrical Division, Tirunelveli.
Providing 1 No 2.0 TR Airconditioner, AC Power Mains Arrangements and supply connection to the UPS for CRYOSTAT Machine in PATHOLOGY Department at Faculty Block in the Kanniyakumari Govt. Medical College at Asaripallam in Kanniyakumari District.
2026_PWD_699573_1
5(20)EE/2026-27 dated.27.08.2026
Open Tender
Electrical and Maintenance Works
Lump-sum
30 days
Asaripallam
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
22 Sept 2026
3 Sept 2026
18 Sept 2026
3 Sept 2026
18 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and Installation of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of | 1 | No | 46,140 | ₹46,140 |
| 1.01 | Cooling
Dehumidifying
Air Circulating
Filtering
The installation works for the above split type AC units includes the following.
1.Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.
3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.
4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit.
5. Leakage testing the entire system unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit. (Carrier/Voltas/O General) (Blood Bank ) | - | - | - | - |
| 2 | Supply and Installation of 5KVA Capacity Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 1 | No | 4,646 | ₹4,646 |
| 3 | Supply and fixing of MS stand for fixing the Outdoor unit. | 1 | No | 979 | ₹979 |
| 4 | Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) | 3 | Mtrs | 980 | ₹2,940 |
| 5 | Supply and fixing of water drain pipe line (1" PVC PIPE) | 20 | Mtrs | 58 | ₹1,160 |
| 6 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. | 32 | Mtrs | 255 | ₹8,160 |
| 7 | Supply and fixing of 32 Amps DP MCB with sheet steel enclosure (Higher end) in flush with wall and making good of the concealed portion with earth connection. (The DP MCB & Enclosure should be of (Higher end) | 3 | Nos | 1,339 | ₹4,017 |
| 8 | Supply and fixing of Single Pole 6A to 32A, 10KAin Existing DB including labour charges. | 2 | Nos | 170 | ₹340 |
| 9 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall/floor/ground for earth connection. | 9 | Mtrs | 196 | ₹1,764 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
TNO55.pdf
Tender Documents • 0.80 MB
BOQ_840976.xls
BOQ • 0.39 MB
corrigendum5.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .