Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹27.7 L+₹1,626.84 (0.06%)Admitted-Finance H NO 31 DUPLEX MOTIAZ ROYAL FAME VILL CHAJJA MAJRA PO LANDRAN SEC 117 DISTT SAS NAGAR MOHALI PB PIN 140307 | S A S NAGAR | PUNJAB | 140307 | L2 | Admitted-Finance | |
| 3 | L3₹27.9 L+₹20,341.84 (0.74%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Dharm Singh Contractor L2 | S Rajan L3 | M/S Sudhir Kumar Gupta L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying, laying or fixing, GI water tubing, medium grade, 50mm dia bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up/ down existing unserviceable GI tubing with fittings / connections carefully from trenches / celiling /walls/roofs etc complete all as specified and as directed. | 380 | RM | 1,600 ₹6,08,000 | 1,500 ₹5,70,000 Lowest | 1,558 ₹5,92,040 |
| 2.00 | Supplying, laying or fixing, GI water tubing, medium grade, 80mm dia bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up/ down existing unserviceable GI tubing with fittings / connections carefully from trenches / celiling /walls/roofs etc complete all as specified and as directed. | 30 | RM | 2,550 ₹76,500 | 2,500 ₹75,000 | 2,378 ₹71,340 Lowest |
| 3.00 | S & F submersible Pumping Sets, 5 HP including suitable starter with sheet metal enclosure outdoor type for housing for starter electrical driven, three phase, pump Energy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Motors (IE2) , 2840 RPM (enclosure confirming to protection IP 55 as per IS:4691-1968) horizontal foot mounted induction motors, continuously rated suitable for operation on 415+/-10%, 50 Hz+/5%, A.C. supply with class 'F' insulation for 50 Deg C ambient temperature and altitiude less than 1000M above MSL, Head upto 25 mtr, Discharge: 400 (LPM) and confirming to IS 325:1996 & IS 12615:2011 complete all as specified and as directed.
Note:
(i) Rates for PCC foundation are deemed to be inclusive
(ii) Rates for NRV as recommended by OEM are to be measured seperately under respective items
(iii) Rates of Foot Valve of required size is deemed to be included in the quoted rate. | 2 | Each | 1,15,000 ₹2,30,000 | 95,000 ₹1,90,000 | 81,999.18 ₹1,63,998.36 Lowest |
| 4.00 | S & F submersible Pumping Sets, 2 HP including suitable starter and pump foundation with PCC, electrical driven, three phase, pump Energy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Motors (IE2) , 2840 RPM (enclosure confirming to protection IP 55 as per IS:4691-1968) horizontal foot mounted induction motors, continuously rated suitable for operation on 415+/-10%, 50 Hz+/5%, A.C. supply with class 'F' insulation for 50 Deg C ambient temperature and altitiude less than 1000M above MSL, Head range: 24-39 mtr, Discharge: 455-200 (LPM) and confirming to IS 325:1996 & IS 12615:2011 complete all as specified and as directed.
Note:
(i) Rates for PCC foundation are deemed to be inclusive
(ii) Rates for NRV as recommended by OEM are to be measured seperately under respective items
(iii) Rates of Foot Valve of required size is deemed to be included in the quoted rate. | 1 | Each | 58,000 ₹58,000 | 75,000 ₹75,000 | 40,999.18 ₹40,999.18 Lowest |
| 5.00 | Supply, install mild steel measuring scale with proper measuring numbers with synthetic enamel paint complete all as specified and as directed. | 1 | Each | 5,000 ₹5,000 | 30,000 ₹30,000 | 2,459.18 ₹2,459.18 Lowest |
| 6.00 | S & F PVC sheathed submersible copper cable of size 3 Core x 4 Sqmm complete all as specified and as directed. | 50 | RM | 380 ₹19,000 Lowest | 500 ₹25,000 | 819.18 ₹40,959 |
| 7.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. | 49.6 | Cum | 400 ₹19,840 Lowest | 900 ₹44,640 | 491.18 ₹24,362.53 |
| 8.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in excavated soil all as specified and as directed. | 44.1 | Cum | 200 ₹8,820 | 450 ₹19,845 | 163.18 ₹7,196.24 Lowest |
| 9.00 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed. | 5.5 | Cum | 200 ₹1,100 Lowest | 500 ₹2,750 | 245.18 ₹1,348.49 |
| 10.00 | S & F Gate valve flanged of class 1.0 PN 50mm dia complete all as specified and as directed. | 2 | Each | 6,500 ₹13,000 Lowest | 9,800 ₹19,600 | 16,399.18 ₹32,798.36 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
6 Oct 2025, 6:00 pmClosed
GE
GE (I) CAMPBELL BAY, ARMY LAND, CAMPBELL BAY, GREAT NICOBAR-744302
PROVN OF CONTINUOUS WATER SUPPLY CONNECTION AT INS BAAZ, 1.5 TON X 04 SPLIT AC AT INS BAAZ, SPL REP TO CERTAIN LT SWITCH GEAR EQUIPMENTS AT INS BAAZ, CEILING FAN IN EXISTING TRAINING SHED AT 172 INF BN (TA) MADRAS CINCAN LAND (ARMY) CAMPBELL BAY
2025_MES_729752_1
8204/E8
Open Tender
Civil Works
Item Rate
180 days
CAMPBELL BAY
PLEASE REFER TENDER DOCUMENT AND NIT
9 documents required · 9 mandatory
₹500
GE(I) CAMPBELL BAY
₹56,000
Yes
1 Nov 2025
8 Sept 2025
8 Oct 2025
8 Sept 2025
6 Oct 2025
22 Sept 2025
Amount
Supplying, laying or fixing, GI water tubing, medium grade, 50mm dia bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up/ down existing unserviceable GI tubing with fittings / connections carefully from trenches / celiling /walls/roofs etc complete all as specified and as directed.
Supplying, laying or fixing, GI water tubing, medium grade, 80mm dia bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up/ down existing unserviceable GI tubing with fittings / connections carefully from trenches / celiling /walls/roofs etc complete all as specified and as directed.
S & F submersible Pumping Sets, 5 HP including suitable starter with sheet metal enclosure outdoor type for housing for starter electrical driven, three phase, pump Energy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Motors (IE2) , 2840 RPM (enclosure confirming to protection IP 55 as per IS:4691-1968) horizontal foot mounted induction motors, continuously rated suitable for operation on 415+/-10%, 50 Hz+/5%, A.C. supply with class 'F' insulation for 50 Deg C ambient temperature and altitiude less than 1000M above MSL, Head upto 25 mtr, Discharge: 400 (LPM) and confirming to IS 325:1996 & IS 12615:2011 complete all as specified and as directed. Note: (i) Rates for PCC foundation are deemed to be inclusive (ii) Rates for NRV as recommended by OEM are to be measured seperately under respective items (iii) Rates of Foot Valve of required size is deemed to be included in the quoted rate.
S & F submersible Pumping Sets, 2 HP including suitable starter and pump foundation with PCC, electrical driven, three phase, pump Energy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Motors (IE2) , 2840 RPM (enclosure confirming to protection IP 55 as per IS:4691-1968) horizontal foot mounted induction motors, continuously rated suitable for operation on 415+/-10%, 50 Hz+/5%, A.C. supply with class 'F' insulation for 50 Deg C ambient temperature and altitiude less than 1000M above MSL, Head range: 24-39 mtr, Discharge: 455-200 (LPM) and confirming to IS 325:1996 & IS 12615:2011 complete all as specified and as directed. Note: (i) Rates for PCC foundation are deemed to be inclusive (ii) Rates for NRV as recommended by OEM are to be measured seperately under respective items (iii) Rates of Foot Valve of required size is deemed to be included in the quoted rate.
Supply, install mild steel measuring scale with proper measuring numbers with synthetic enamel paint complete all as specified and as directed.
S & F PVC sheathed submersible copper cable of size 3 Core x 4 Sqmm complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in excavated soil all as specified and as directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
S & F Gate valve flanged of class 1.0 PN 50mm dia complete all as specified and as directed.
M & L for valve chamber of size 600mm x 600mm x 600mm (Internal) with brick masonry 230 mm thick in CM( 1:6), PCC (1:4:8) type, D-2 foundation 75 mm thick, finished fair and even, PCC (1:2:4) type, B-1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar (1:4) plaster on exposed surfaces of brick wall (both internal and external), mild steel cover of 3.15 mm thick including mild steel angle iron 40 x 40 x 6 mm size frame fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary excavation and earth work complete all as specified and directed.
S & F of energy efficient 5 Star rating, BLDC motor, dust proof, Ceiling Fan 1200 mm sweep size, copper winding with minimum air delivery of 210 cu.mtr/min, A.C, single phase, 220 volt 50 Hz including canopy reel , flexible copper conductor fixing with necessary lugs drawn through flexible PVC conduit from ceiling rose, including necessary hook, rubber bush & safety pin all necessary accessories complete all as specified and as directed.
M & L for point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing surface type and accessories of suitable size ISI marked and terminal boxes modular type of 1.0 mm thick of suitable size including fixing/ grouting modular surface box as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for One fan point controlled by one, one way switch 6 Amps complete all as specified and as directed.
S & F Modular switch 1 way 6 A, 1 Module complete all as specified and as directed.
S & F Modular Fan step regulator, 80W-2 Module complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
M & L for fan down rod made out of GI pipe light grade 20 mm dia including cutting, threading and making holes for the purpose of down rods to ceiling fans with making good by applying two coats of white colour oil paint over one coat of red oxide and including 'D' clamp with all fixing arrangements on channel/pipe, nut and bolts for hanging of ceiling fans complete all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs, IP-43, 8 way with 200 Amps rated busbar, 240 volts, as per IS-8623 complete all as specified and as directed.
S & F MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc., complete all as specified and as directed.
S & F MCB SP 6-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc., complete all as specified and as directed.
M & L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in plate No. 3 of SSR PART 1 of 2009 to the earthing test point including testing on completion all as specified and as directed. Note :- (i) The cost of excavation and earth work PCC pit and RCC cover funnel & watering pipe, wiremesh, charcoal dust and common salt earth lead protection pipe upto 7.5 Rmt shall be deemed included in the unit rate. (ii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 Sqmm 2.0 core complete all as specified and as directed.
S & F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having inner dia 50 mm complete terminated up to termination end point complete all as specified and as directed.
M & L for submain wiring with two single core 4 Sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable drawn through in and including 20mm dia rigid PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire complete all as specified and as directed. Note: 3 run of 4 Sqmm & one run of PVC conduit shall be measured as single unit
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Supply & install invertor based split AC of capacity 1.5 TON (copper coil) electric driven single phase, 230 volts, BEE 5 star rating including all accessories like brackets.,rubber tubing, copper tubing, gas charging with auto filter clean technology etc including testing and commissioning as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as specified and as directed.
Supply, installation, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
S & F Split AC stand of outdoor unit suitable for 1.5 ton includingnecessary fixing arrangement complete all as specified and as directed.
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size, 3 Phase 4 wire system Outdoor type 3.15mm, double door front and back opening type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 Core in and out(Panel board shall have sufficient space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENTS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50 x 50 x 6mm thick duly painted and embeded in PCC 1:3:6 type C1, including taking down old u/s one complete and consisting the following provisions:-
(a) MCCB 400 Amps Four Pole AC 415 Volts, 50 Hz, 36kA , Adjustable Thermal & fixed Magnetic settings - 01 No(Incoming) (b) Aluminium Busbar 600 Amps with Sleeves -04( three phase with neutral and connectors set of 4) (c) Indicator lamp set of 3 - 01 Set (d) Control wiring with PVC insulator multistranded copper conductor, insulators for busbar mounting 3 Nos of suitable CT's and accessories - 01 Set (e) Digital Type multi dislay VAF+PF cl-0.5 accuracy-01 No (f) Insulators:SMC/DMC
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size, 3 Phase 4 wire system Outdoor type 3.15mm, double door front and back opening type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 Core in and out(Panel board shall have sufficient space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENTS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50 x 50 x6mm thick duly painted and embeded in PCC 1:3:6 type C1, including taking down old u/s one complete and consisting the following provisions:-
(a) MCCB 125Amps Four Pole AC 415 Volts,50Hz,25kA , Adjustable Thermal & fixed Magnetic settings - 01 No(Incoming). (b) MCCB 100 Amps 3Pole, AC, 50Hz 415 Volts, 25 kA -01 No (Outgoing), adjustable thermal & fixed magnetic settings – 01 No (Incoming) (c) MCCB 63 Amps, 3 Pole, AC, 50 Hz, 415 Volts, 16kA -01 No (Outgoing), adjustable thermal & fixed magnetic settings – 01 No (Incoming) (d) Aluminium Busbar 200 Amps with Sleeves -04( three phase with neutral and connectors set of 4) (e) Indicator lamp set of 3 - 01 Set (f) Control wiring with PVC insulator multistranded copper conductor, insulators for busbar mounting 3 Nos of suitable CT's and accessories - 01 Set (g) Digital Type multi dislay VAF+PF cl-0.5 accuracy-01 No (h) Insulators:SMC/DMC
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as requied 25 x 6mm galvanised iron strip including taking old unserviceable one complete all as specified and as directed.
Supply, test, install & commsissioning of 4-Way, 200 Amps Bus bar chambers (including 4 bus bars i.e R,Y,B and neutral), 3-Ph with neutral,1100 volts, 50Hz including suitable sheet metal enclosure along with necessary screws, nuts, bolts and other misc accessories and making connections (input & out put) with cable terminal ends complete for the following current carrying capacities, panel mounted on suitable size & thickness of angle iron frame (proper mounting shall be done) duly painted and embeded in necessary required quantity of PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level complete all as specified and as directed.
Supply, test, laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade (earthed), 3.5 core 185 Sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/ tunnel /under ground/ surface up to the termination point (as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool, nuts, bolts etc complete all as specified and as directed.
Supply, test, laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade (earthed), 3.5 core 150 Sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/ tunnel /under ground/ surface up to the termination point (as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool, nuts, bolts etc complete all as specified and as directed.
Dharm Singh Contractor (BID ID -3443426)
S Rajan (BID ID -3438267)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .