Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | Admitted-Finance |
| 2 | Admitted-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹99,990
Closing Date
7 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF OLD DETERIORATED FAULTY UNDERGROUND LT CABLES METER PANEL BOARDS INCLUDING REPAIR OF ELECTRIC METERS AND CONNECTED WORKS AT VARIOUS BLDGS AT CELL 02 NOFRA COLABA MUMBAI
2024_MES_673896_1
8329
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹99,990
Yes
17 Oct 2024
11 Sept 2024
9 Oct 2024
11 Sept 2024
7 Oct 2024
25 Sept 2024
11 Sept 2024 - 18 Sept 2024
Amount
Note : (a) Functional tools & plants shall be carried by tradesman all time for attending any site. (b) Necessary ladder / cloth or any other material reqd. (c) Debris / site clearance immediately before leaving site. (d) Safety eqpt to be carried all time. (e) In case of non-adherence of any of above fine/ penalty to be carried as under:- (i) 1st Time - Rs 200/- (ii) 2nd Time - Rs 500/- (iii) 3rd Time - Warning to contractor. (f) In case of 3 warning to contractor, it will be reflected in WLR for slow progress. (g) Complaint registered upto 11:00AM & emergency complaint to be attended same day. (h) Complaint Team consist of 02 Electrician alongwith reqd helpers.
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels/Meter Panels Indoor type by taking shut down from appropiate authority including following activities (i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectify the same with help of new GI nut bolts and washers. (iii) Replaceing the burnt out colour coated PVC Sleeve of main and fedders bus with appropriate size of New PVC heat shrinkable sleeves -01Job. (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses. (v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job. (vi) Replacing Burnt out Bus Bar of feeders with appropriate size new bus bar (Copper/Aluminum) -01Job (vii) Replacing Burnt out Insulators of feeders with appropriate size new Insulators -01Job (viii) Note For item No (iv),(vi),(vii) New items will be measured and paid seperately as supply only item no 4,5,8,9,10 in this schedule
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric FPB Out door type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter /Ammeter/CT/LED lamps of any type and discription etc
(i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectify the same with help of new GI nut bolts and washers (iii) Replacing the burnt out colour coated PVC Sleeve of main and fedders bus with appropriate size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses. (v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of feeders with appropriate size new bus bar (Copper/Aluminum) -01Job (vii) Replacing Burnt out Insulators of feeders with appropriate size new Insulators -01Job (viii) Re welding of Doors with new hinges (viii) Note For item No (iv),(vi),(vii) New items will be measured and paid seperately as supply only item no 4,5,8,9,10 in this schedule.
Supply only Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply only Copper Bus Bar strip, of any size, for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply and fix in repair suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.
supply only indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 230Volts AC and all as specified and directed.
Supply & fix in repair MCCB,4Pole,400 Amps,35kA,thermal magnetic adjustable type, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,320 Amps,35kA, thermal magnetic adjustable type,415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,250 Amps,25kA, thermal magnetic adjustable type,415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,200 Amps,25kA,Thermal magnetic adjustable type, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,160 Amps,25kA,thermal magnetic adjustable type, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,125 Amps,25kA,thermal magnetic adjustable type, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,100 Amps,16kA,thermal magnetic adjustable type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair MCCB,4Pole,63 Amps,16kA,thermal magnetic adjustable type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Change Over Switch ,4Pole,400 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Change Over Switch ,4Pole,250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 95Sqm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 70Sqmm to 50Sqmm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 35Sqmm to 25Sqmm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Aluminum Lugs with PVC Insulation Tape of size 16Sqmm to 10Sqmm complete all as specified and directed by Engr-in-charge.
Supply & fix in repair Current Transformers,415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Supply & fix in repair Current Transformers,415V 300/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Supply & fix in repair Current Transformers,415V 250/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Supply & fix in repair Current Transformers,415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Supply & fix in repair following Spare parts suitable for -ACB 415V , 630 to 1200Amps Amps indoor type all as specified and directed by Engineer-in-Charge.
Shunt Trip Device/Electronic trip relay
Closing coil assembly
Mismatch Prevention Device
Moving contacts assembly
Fixed Contact assembly
Auxialary Switch
Arc chute with hardware
Material and labour for fault finding on LT cables of any size and any length with fault detector machine by TDR/Thumber method and all as and directed by Engineer-in-charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT KIT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 16 to 25 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT KIT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 35 to 50 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT KIT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT KIT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge.
Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in LT Panels Boards/FPB/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 400Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 300Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core and all as directed by Engineer-In-Charge.
M&L for Cutting and removing of old faulty cable piece and Supply and laying XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 185Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 35Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 25Sqmm 3.5core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 16Sqmm 4core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4core and all as directed by Engineer-In-Charge.
Taking down Old XLPE cable of any size as specified and directed.
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.
Material and Labour for Attending Faults/Trippings and rectifing /repairing the faults in DG Sets/AMF Panels etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. [Note : (i) Spare parts will be measured and paid separately in item no 89,90,91,92 of this schedule. (ii) Fault rectification and restore the supply with in 4hrs otherwise penalty liable Rs 500 per hour till supply will restore.]
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening Minimum size 1200x1200x 600 mm or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening suitable at site or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening suitable at site or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
Dismantling of old damaged panel Boards all as specified and directed.
M&L for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2(using 20mm graded stone aggregate) and PCC cover 1:2:4 type B1(using 20mm graded stone aggregate) weatering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strips complete all as specified and directed by Engr - in - Charge.
Supply, install, testing and commissioning of LT Feeder Pilar CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening and suitable size for fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 1000 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
Material and labour for servicing of DG set of capacity 62.5 KVA to 125 KVA by carrying out the following maintenance including testing on completion for satisfactory performance for a period of 02 hrs. at connected load complete all as specified and as directed :- (Note: Spare parts,Engine Oil, Coolent will be measured and paid seperately as 'Supply only item no 63,64,65,66 of this schedule')
Supply only of Engine Oil 20W40 for DG set of capacity 62.5KVA to 125KVA and all as specified and directed by Engineer-in-Charge.
Supply only of Coolent for DG set of capacity 62.5KVA to 125KVA and all as specified and directed by Engineer-in-Charge.
Supply only of Distile water for DG set of capacity 62.5KVA to 125KVA and all as specified and directed by Engineer-in-Charge.
Supply only of Battery Acid for DG set of capacity 62.5KVA to 125KVA and all as specified and directed by Engineer-in-Charge.
Material & Labour for Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/spring assembly bearing, regulator etc. of any make, type and capacity 62.5KVA DG set complete all as specified and directed by Engineer In Charge.
Material & Labour for Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/spring assembly bearing, regulator etc. of any make, type and capacity 82.5 to 125KVA DG Set complete all as specified and directed by Engineer In Charge.
Supply and fixing in replacement battery charger 24 Volts suitable for 12 volts 180 AH Battery Float cum Boost type complete all as specified and directed by Engineer In Charge.
M&L for Dismantling and Servicing/repairing of Radiator assembly , flushing it complete, testing the radiator of water tightness,soldering the leakage spot, replace the loose radiator cap , rubber hose and re connect the radiator assembly to engine capacity 62.5KVA and testing complete all as specified and directed by Engineer In Charge.
M&L for Dismantling and Servicing/repairing of Radiator assembly , flushing it complete, testing the radiator of water tightness,soldering the leakage spot, replace the loose radiator cap , rubber hose and re connect the radiator assembly to engine capacity 82.5KVA to 125KVA and testing complete all as specified and directed by Engineer In Charge.
M& L for Servicing of alternator including cleaning of field and ammature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system capacity 62.5KVA etc complete all as specified and directed by Engineer In Charge.
M& L for Servicing of alternator including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system capacity 82.5KVA to 125KVA etc complete all as specified and directed by Engineer In Charge.
Supply and fix in replacement of AVR for following DG set complete all as specified and directed by Engineer In Charge.
DG Set 125KVA
DG Set 62.5 to 82.5KVA
M &L for Cleaning of the fuel tank of 62.5 KVA to 125 KVA capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity 62.5KVA to 125KVA complete all as specified and directed by Engineer In Charge.
Material & Labour for servicing of Self Starter 12/24VoltsDC from DG set,dismantling complete and replacement of solonide field coils,cleaning the cummutator strips including replacing the bearing,bends pinion re assembling,connecting and testing complete all as directed by Enginee-In-Charge
M&L for Callibration of fuel injector of DG set capacity 62.5 KVA DG Set complete all as specified and directed by Engineer In Charge.
M&L for Callibration of fuel injector of DG set capacity 82.5 to 125 KVA DG Set complete all as specified and directed by Engineer In Charge.
Supply & Fix in repair of Exhaust silencer suitable for Diesel Engine,capacity 62.5KVA all as specified and directed by Engineer-In-Charge.
Supply & Fix in repair of Exhaust silencer suitable for Diesel Engine,capacity 82.5KVA to 125KVA all as specified and directed by Engineer-In-Charge.
Supply & Fix in repair Self starter suitable for 62.5 KVA DG Set complete all as specified and directed by Engineer In Charge.
Supply & Fix in repair Self starter suitable for 82.5KVA to 125 KVA DG Set complete all as specified and directed by Engineer In Charge.
Supply & fix in replacement of battery 12 volts 180 AH suitabe for DG set starting complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.
Supply & fix in replacement of battery 12 volts 150 AH suitable for DG set starting complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.
Supply & fix in replacement of unserviceable pre Lube Hyd lift pump VIC for 62.5KVA and taking down the same complete all as specified and directed by Engineer In Charge.
Supply & fix in replacement of unserviceable pre Lube Hyd lift pump VIC for 82.5KVA to 125KVA and taking down the same complete all as specified and directed by Engineer In Charge.
M&L for Taking down the old unserviceable water body of DG set of capacity 62.5KVA by un screw the ,fan, fan belt, hose pipe and remove the its position and replacing with new water body as per sample complete all as specified and directed by Engineer In Charge.
Taking down the old unserviceable water body of DG set 82.5KVA to 125KVA by un screw the ,fan, fan belt, hose pipe and remove the its position and replacing with new water body as per sample complete all as specified and directed by Engineer In Charge.
Supply & fix Power Contactor,80Amps ,4pole with 2NO+2NC suitable for 62.5KVADG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.
Supply & fix Power Contactor,100Amps ,4pole with 2NO+2NC suitable for 82.5KVADG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.
Supply & fix Power Contactor,160Amps ,4pole with 2NO+2NC suitable for 125KVA set existing AMF Panel and complete all as specified and directed by Engineer In Charge.
Supply & fix LED indicating lamps(Red/Green/Yellow/Blue) 24/230V DC/AC in existing AMF Panel and complete all as specified and directed by Engineer In Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in soft/loose soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. [Note :- Only compacted thickness of sand will be measured and paid.]
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
OM SAI POWER SYSTEMS (BID ID -3121168)
N.S.ENTERPRISES (BID ID -3128261)
ASHOK ENTERPRISES (BID ID -3120649)
B P ENTERPRISES (BID ID -3119955)
NOEL ENGINEERS (BID ID -3127406)
SHREE JAGDISH FURNITURE CO. (BID ID -3121170)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .