Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | ₹29.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.3 L+₹82,759 (2.81%)Rejected-Finance | ₹30.3 L+₹82,759 (2.81%) | L2 | Rejected-Finance Being L2 |
Tender Value
₹29.5 L
EMD Value
₹52,000
Closing Date
6 Sept 2021, 5:00 pmClosed
XEN Elect Divn No II
XEN Elect Divn No II HPPWD Shimla-2
Providing manifold system
2021_PWD_51627_1
ED.II.GA.Tender/21-22-3859-60 dated 23.08.2021
Open Tender
Electrical Works
Item Rate
30 days
Theog District Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Elect Divn No II
₹52,000
21 Oct 2021
27 Aug 2021
7 Sept 2021
27 Aug 2021
6 Sept 2021
27 Aug 2021
Amount
Supply, Installation ,Testing and Commissioning of 10 + 10 manifold system complete with NRV & TAIL pipes as required complete at site.
Supply, installation, testing and commissioning of fully Automatic Control Panel for Oxygen manifold as directed at site.
Supply and installation of Duplex vaccumme system complete withbacteria filter and receiver tank.The filters should be designed for removal of solid, liquid and bacterial contamination from the suction side of vacuum pump systems, preventing damage to the pump and the potential biological infection of the surrounding environment. The dryer should be particulate filter dryer with ability to remove particles as small as 1micron. Each individual filter shall have the capacity to deliver full design flow such that one set is designated duty and the other will be standby. Bacteria filters shall have efficiency at least 99.999% when tested by the sodium flame method in accordance with BS 3928:1969/as per required standard utilizing particles in the 0.02 to 2 micron size range. The pressure drop across each clean filter at 50% of the system design flow should not exceed 25 mm Hg (3 kPa) at a vacuum of 475mm of Hg (63 kPa). Bacteria filters shall be marked with the legend ‘Bio-Hazard’. Each bacteria filter shall be provided with a transparent sterilizable collection jar to collect condensate.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 120 sq. mm (3.5 core)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
250 Amp. -35 KA
ULTIMED SOLUTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .