Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAdmitted-Finance BAKRABAD BAMRAULI ALLAHABAD U P | ALLAHABAD | U P | L1 | Admitted-Finance | |
| 2 | L2₹44.4 L+₹39,212.50 (0.89%)Admitted-Finance RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L2 | Admitted-Finance | |
| 3 | L3₹45.2 L+₹1.3 L (2.89%)Admitted-Finance EAST VIVEKANANDAPALLY RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L3 | Admitted-Finance | |
| 4 | L4₹46.7 L+₹2.7 L (6.25%)Admitted-Finance MILITARY ROAD OPP RHYTHM SHIVMANDIR PO KADAMTALA DARJEELING 734 011 | DARJEELING | DARJEELING | WEST BENGAL | 734011 | L4 | Admitted-Finance | |
| 5 | L5₹46.8 L+₹2.8 L (6.46%)Admitted-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Embee associates L3 | MS ORIENT ENGINEERING WORKS L5 | M/S RANEN PAL L6 | M/S DAWN ELECTRICAL INDUSTRIES L2 | G C DUTTA N CO L4 | M/S KESRI WORKERS L1 | PAUL CONSTRUCTION L8 | M/S. KARMAKAR ENGINEERING COMPANY L9 | MASSIVE CONSTRUCTION L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for daily inspection, maintenance and servicing of all DG sets of following capacity and locations including Alternator, AMF/ Non AMF panels of connected DG set for daily routine check ( 'A' - check as specified below ) for smooth functioning as per the Manufacturers instructions by Employing experienced one DG Mechanic etc. complete all as specified and as directed by the Engineer-in-Charge. 'A' Check/ daily routine check by each Month include the followings for item No.1 :-(i) Check Engine oil level and toping up as and when required (Engine oil shall l be supplied by MES free for filling )(ii) Check Engine Coolant level if required top up (Coolant shall be measured and paid separately under relevant item)(iii) Check Belts if there is belt slippage adjust or replace(New belt shall be measured and paid separately under relevant item] (iv) Check oil bath cleaner oil level .(v) Check Exhaust System for leakage. (vi) Drain sediment from Fuel filter & Fuel Tank.(vii) Check dry type air filter element and clean or replace (Replacement required shall be measured and paid separately)(viii) Check engine alternator coupling and mounting bolts. (ix) Tight all bolts and nuts in Alternator Terminal Box.(x) Check carbon brushes (Brush type) and connections in Alternator.(xi) Check and tight all Electric connections in DC control wiring.(xii) Check all Radiator rubber Hoses.(xiii) Record oil pressure, water and oil Temp.(xiv) Record RPM, Voltage, AMPS and Hz(xv) Check Anti Vibrating Mountings.(xvi) Check throttle linkage.(xvii) Check starting battery electrolyte level and specific gravity, top up level regularly Note for item No.1.00 to 1.38:i) Routine check / repair work of AMF Panel will be measured and paid separately under respective item of sch here in after. | 9 | Per Month | 280 ₹2,520 Lowest | 35,000 ₹3,15,000 | 36,000 ₹3,24,000 | 34,000 ₹3,06,000 | 35,613 ₹3,20,517 | 46,100 ₹4,14,900 | 36,500 ₹3,28,500 | 36,000 ₹3,24,000 | 36,033 ₹3,24,297 |
| 1.01ii) Repair/maintenance of Panels of DG set other than AMF panel is deemed to be inclusive of rate except control switches ie MCCB/ Main Switch/ Voltmeter, Ammeter, Hz meter, Selector switches and CT's etc., 1.02 DG set 320 KVA installed at signal centre 1.03 DG (No. 01) 250 KVA installed at Signal centre , 1.04 DG set (No 02) 250 KVA installed at Singnal centre, 1.05 DG set 250 KVA installed at Madhuban PH, 1.06 DG set 180 KVA installed near Signal centre, 1.07 DG set 125 KVA installed at Md Accn PH Sukna, 1.08 DG set 82.5 KVA installed at MAP - 2, 1.09 DG set 63 KVA installed at Md Accn PH Sukna, 1.10 DG set 62.5 KVA installed at TRHS, 1.11 DG set 62.5 KVA installed at Map - 2, 1.12 DG set 62.5 KVA installed at Rocket Regt, 1.13 DG set 58.5 KVA installed at Rocket Regt, 1.14 DG set 50 KVA installed at 15 MAHAR, 1.15 DG set 50 KVA installed at 72 Enger Regt, 1.16 DG set 40 KVA installed at 12 PARA (SF), 1.17 DG set 40 KVA installed at 22 DOG Unit. 1.18 DG set 40 KVA installed at 108 Wksp, 1.19 DG set 35 KVA installed at 33 CSr, 1.20 DG set 35 KVA installed at 7033 EME Bn, 1.21 DG set 32.5 KVA installed at Taranju bari, 1.22 DG set 30 KVA installed at 63 Mnt Brig, 1.23 DG set 30 installed at Core PH, 1.24 DG set 30 KVA installed at Hopper Tank, 1.25 DG set 30 KVA installed at Rangpur PH-I, 1.26 DG set 30 KVA installed at Pinaka Site, 1.27 DG set 30 KVA installed at 5033 ASC Bn, 1.28 DG set 25 KVA installed at Pinaka, 1.29 DG set 25 KVA installed at MAP PH-I | ||||||||||||
| 2.00Supply only the following spares as per existing make all as directed :- | ||||||||||||
| 2.01 | Engine oil 20 W 40 / 10 W 40 Grade. | 480 | Litre | 285 ₹1,36,800 | 290 ₹1,39,200 | 300 ₹1,44,000 | 280 ₹1,34,400 Lowest | 296 ₹1,42,080 | 370 ₹1,77,600 | 295 ₹1,41,600 | 300 ₹1,44,000 | 299 ₹1,43,520 |
| 2.02 | Coolant for DG set. | 250 | Litre | 225 ₹56,250 | 222 ₹55,500 | 225 ₹56,250 | 215 ₹53,750 | 224 ₹56,000 | 270 ₹67,500 | 210 ₹52,500 Lowest | 230 ₹57,500 | 227 ₹56,750 |
| 2.03 | Diesel exhaust fluid,aqueous urea solution (AUS 32) | 300 | Litre | 290 ₹87,000 | 286 ₹85,800 | 290 ₹87,000 | 280 ₹84,000 | 290 ₹87,000 | 190 ₹57,000 Lowest | 290 ₹87,000 | 290 ₹87,000 | 294 ₹88,200 |
| 2.04 | Distilled water for battery set. | 50 | Litre | 30 ₹1,500 | 26 ₹1,300 | 30 ₹1,500 | 20 ₹1,000 | 26 ₹1,300 | 19.95 ₹997.5 Lowest | 30 ₹1,500 | 30 ₹1,500 | 26 ₹1,300 |
| 2.05 | Oil Filter for 320 KVA DG set.
(Make: - Greaves Cotton Ltd.) | 2 | Each | 5,200 ₹10,400 | 5,100 ₹10,200 | 5,210 ₹10,420 | 5,000 ₹10,000 Lowest | 5,190 ₹10,380 | 5,225 ₹10,450 | 5,250 ₹10,500 | 5,150 ₹10,300 | 5,251 ₹10,502 |
| 2.06 | Oil Filter for 250 KVA DG set.
(Make: - Mahindra) | 6 | Each | 5,230 ₹31,380 | 5,100 ₹30,600 | 5,210 ₹31,260 | 5,000 ₹30,000 | 5,190 ₹31,140 | 4,275 ₹25,650 Lowest | 5,250 ₹31,500 | 5,150 ₹30,900 | 5,251 ₹31,506 |
| 2.07 | Oil Filter for 180 KVA DG set.
(Make: - Kirloskar ) | 2 | Each | 4,000 ₹8,000 | 4,200 ₹8,400 | 4,190 ₹8,380 | 4,000 ₹8,000 | 4,172 ₹8,344 | 3,800 ₹7,600 Lowest | 4,200 ₹8,400 | 4,150 ₹8,300 | 4,221 ₹8,442 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Aug 2026, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIR AND MAINT OF DIFFERENT CAPACITY DG SETS CABLES SWITCH GEARS AND OTHER MISC E/M WORKS UNDER AGE E/M OF GE SUKNA AT MIL STN SUKNA
2026_MES_779209_1
GE Sukna/9157
Open Tender
Civil Works
Works
180 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹90,000
14 Aug 2026
17 Jul 2026
10 Aug 2026
18 Jul 2026
7 Aug 2026
31 Jul 2026
18 Jul 2026 - 7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for daily inspection, maintenance and servicing of all DG sets of following capacity and locations including Alternator, AMF/ Non AMF panels of connected DG set for daily routine check ( 'A' - check as specified below ) for smooth functioning as per the Manufacturers instructions by Employing experienced one DG Mechanic etc. complete all as specified and as directed by the Engineer-in-Charge. 'A' Check/ daily routine check by each Month include the followings for item No.1 :-(i) Check Engine oil level and toping up as and when required (Engine oil shall l be supplied by MES free for filling )(ii) Check Engine Coolant level if required top up (Coolant shall be measured and paid separately under relevant item)(iii) Check Belts if there is belt slippage adjust or replace(New belt shall be measured and paid separately under relevant item] (iv) Check oil bath cleaner oil level .(v) Check Exhaust System for leakage. (vi) Drain sediment from Fuel filter & Fuel Tank.(vii) Check dry type air filter element and clean or replace (Replacement required shall be measured and paid separately)(viii) Check engine alternator coupling and mounting bolts. (ix) Tight all bolts and nuts in Alternator Terminal Box.(x) Check carbon brushes (Brush type) and connections in Alternator.(xi) Check and tight all Electric connections in DC control wiring.(xii) Check all Radiator rubber Hoses.(xiii) Record oil pressure, water and oil Temp.(xiv) Record RPM, Voltage, AMPS and Hz(xv) Check Anti Vibrating Mountings.(xvi) Check throttle linkage.(xvii) Check starting battery electrolyte level and specific gravity, top up level regularly Note for item No.1.00 to 1.38:i) Routine check / repair work of AMF Panel will be measured and paid separately under respective item of sch here in after. | 9 | Per Month | - | - |
| 1.01 | ii) Repair/maintenance of Panels of DG set other than AMF panel is deemed to be inclusive of rate except control switches ie MCCB/ Main Switch/ Voltmeter, Ammeter, Hz meter, Selector switches and CT's etc.,
1.02 DG set 320 KVA installed at signal centre 1.03 DG (No. 01) 250 KVA installed at Signal centre , 1.04 DG set (No 02) 250 KVA installed at Singnal centre, 1.05 DG set 250 KVA installed at Madhuban PH, 1.06 DG set 180 KVA installed near Signal centre, 1.07 DG set 125 KVA installed at Md Accn PH Sukna, 1.08 DG set 82.5 KVA installed at MAP - 2, 1.09 DG set 63 KVA installed at Md Accn PH Sukna, 1.10 DG set 62.5 KVA installed at TRHS, 1.11 DG set 62.5 KVA installed at Map - 2, 1.12 DG set 62.5 KVA installed at Rocket Regt, 1.13 DG set 58.5 KVA installed at Rocket Regt, 1.14 DG set 50 KVA installed at 15 MAHAR, 1.15 DG set 50 KVA installed at 72 Enger Regt, 1.16 DG set 40 KVA installed at 12 PARA (SF), 1.17 DG set 40 KVA installed at 22 DOG Unit. 1.18 DG set 40 KVA installed at 108 Wksp, 1.19 DG set 35 KVA installed at 33 CSr, 1.20 DG set 35 KVA installed at 7033 EME Bn, 1.21 DG set 32.5 KVA installed at Taranju bari, 1.22 DG set 30 KVA installed at 63 Mnt Brig, 1.23 DG set 30 installed at Core PH, 1.24 DG set 30 KVA installed at Hopper Tank, 1.25 DG set 30 KVA installed at Rangpur PH-I, 1.26 DG set 30 KVA installed at Pinaka Site, 1.27 DG set 30 KVA installed at 5033 ASC Bn, 1.28 DG set 25 KVA installed at Pinaka, 1.29 DG set 25 KVA installed at MAP PH-I | - | - | - | - |
| 2Supply only the following spares as per existing make all as directed :- | |||||
| 2.01 | Engine oil 20 W 40 / 10 W 40 Grade. | 480 | Litre | - | - |
| 2.02 | Coolant for DG set. | 250 | Litre | - | - |
| 2.03 | Diesel exhaust fluid,aqueous urea solution (AUS 32) | 300 | Litre | - | - |
| 2.04 | Distilled water for battery set. | 50 | Litre | - | - |
| 2.05 | Oil Filter for 320 KVA DG set.
(Make: - Greaves Cotton Ltd.) | 2 | Each | - | - |
| 2.06 | Oil Filter for 250 KVA DG set.
(Make: - Mahindra) | 6 | Each | - | - |
| 2.07 | Oil Filter for 180 KVA DG set.
(Make: - Kirloskar ) | 2 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_872884.xls
BOQ • 0.43 MB
Tenderdoc9157.pdf
Tender Documents • 1.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .