Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest bidder. | |
| 2 | L2₹10.9 L+₹22,438 (2.10%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹13.5 L+₹2.9 L (26.8%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹11.7 L
EMD Value
₹23,400
Closing Date
16 Jul 2020, 6:00 pmClosed
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_342284_3
GE(S)/PAT-16/S/2020-21
Open Tender
Civil Works
Item Rate
150 days
Mil Stn Sangrur
refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹23,400
Yes
25 Aug 2020
29 Jun 2020
18 Jul 2020
29 Jun 2020
16 Jul 2020
2 Jul 2020
29 Jun 2020 - 1 Jul 2020
Amount
Taking down chowkhats or frames (Wooden or steel chowkats) complete with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removal from site complete all as specified and directed by Engineer-incharge.
Taking down chowkhats or frames (Wooden or steel chowkats) complete with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removal from site complete all as specified and directed by Engineer-incharge.
Taking down wooden shutters of any description exc 1.00 sqm but not exc 2.00 Sqm each and removal from site complete all as specified and directed by Engineer-incharge.
Taking down wooden shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and refixing the shutter in same opening after easing and adjusting complete as directed by Engineer-incharge.
Pressed steel framed made out of 1.25mm thick MS sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed.
All as per serial item No 5 here-in-before but size 105 x 60mm complete all as specified and directed.
Cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in mass concrete or filling backs of chowkats complete all as specified and as directed by Engineer in charge.
S & F Factory made 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Factory made 35 mm thick Glazed and skeleton shutters,2nd class Hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified.
S & F Anodised aluminium powder coated of any colour( thickness of powder not less than 50 microns) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified.
S & F Anodised aluminium window and ventilator shutters fixed type without sash bar, powder coated of any colour ( thickness of powder not less than 50 microns). Aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified
S&F Aluminium tower bolt 200mm long of extruded section and fixed complete all as specified and directed.
Mild steel sliding door bolt of size 250mm bolt type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Supply only Mild steel butt hinges of size 100mm medium weight cold rolled complete all as specified and directed.
S & F Floor door stopper 150 mm long of aluminium alloy body and toungue anodised with hard drawn steel fixed complete all as specified and directed by Engr-in-Charge
S & F Aluminium handles of size 150mm oval type, cast type anodised complete all as specified and directed by Engr-in-Charge.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conformint to Fe-410 W complete all as specified and directed.
Factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S & F 100 mm size PVC butt hinges all as specified and directed.
S & F 125 mm PVC handles all as specified and directed .
S & F 200 mm long PVC tower bolt all as pecified and directed .
Preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer incharge.
Taking down/ removing old unserviceable wire cloth any size from wooden/ metal frames and removal from site complete all as specified and as directed fixed in repair.
S & F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples incl replacement of second class wooden beading where ever reqd complete all as specified & as directed.
M & L for Built in cup boards with pressed steel frame of size 75x45x1.25mm thick and shutter of 1.00 mm thick MS sheet including spray painting 2 coats over a coat of red-oxide primer on steel shurfaces all around all shown on drawing No TD-178 sheet 2/3 to 3/3 dated 12 May 2001 (overall external size of cup board shutter incl frame shall be taken into consideration for the pupose of measurement) including One No hanging rod of CP steel 15/20mm bore with brackets & two Nos peg set of three pegs each fixed inside the shutter complete fixed in repairs i.e, icl taking down and removal of old unserviceable wooden or steel built-in-cupboards incl frame from site all as specified and directed by Engineer-incharge.
Hacking out old broken glass (any thickness , size , quality or description) from wooden or metal frames glazed with oil putty or fixed with beads, removal from site complete all as specified.
S & F Sheet glass ordinary quality 4 mm thick not exe.0.50 sqm glazing with oil putty or fixed with wooden beads in squares any size of pane complete all as specified & as directed.
All as per serial item No 29 here-in-before but 4mm thick frosted glass complete all as specified and directed.
S&F Mild steel rat tail rod pattern helical door spring of size 300mm including roller and roller plate fixing to iron frame by welding complete all as specified & as directed.
Demolition of cement concrete un-reinforced in ground floors and pavings n'exec 150 cm thick (above or below ground level) and removal from site complete all as specified and directed.
Demolition of re-inforced cement concrete of any description and in any position incl cutting of re-inforcement to facilitate demolition where ever required and removal from site complete all as specified and directed.
Glazed ceramic coloured tiles in verticle surfaces joinfree with rectified edges with glazed first quality of size 300 x 600mm or bigger size 7 mm thick as approved set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over 10 mm thick rendering in cement mortar in CM 1:3 for Dado etc., complete all as specified. Note for skirting only Skirting may be provided from the same tiles as being used in the floor of same room to match in lieu of economy finish tiles but nothing extra shall be admissible on this account.
Non Skid Ceramic joinfree tiles {Non Skid finish/ Matt superior finish 7 to 8 mm thick with rectified edges, (square/rectangular) area of each tile exceeding 400mm x400 mm x6 to 7 mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick cement screed in CM 1:4, over 25 mm thick cement concrete 1:2:4 type B-0 complete all as specified and directed by Engr-in-Charge
Rotational molded polythene water storage tanks (cylinder vertical with closed top ) of capacity 500 ltrs, double walled hoisted and fixed in position all as specified in SSR, fixed in repairs, including dismantling of unserviceable water tanks and removing from site, complete all as specified and directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 20mm bore iron pipe or brass ferrule and fixed in repairs complete all as specified and as directed.
S & F Stop valves (Stop Cocks), cast copper alloy, chromium plated screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule for 15 mm bore pipe fixed in repair including taking down & removing old unserviceable stop cock from site complete all as specified and as directed by Engineer incharge.
All as per serial item no 38 here in before but 20 mm bore pipe fixed in repair including taking down & removing old unserviceable stop cock from site complete all as specified and as directed by Engineer incharge
S & F Bib taps, copper alloy, chromium plated, small body with capstan head, screwed for iron pipe 15 mm bore or for brass furrule and fixed in repair including taking down & removing old unserviceable bib cock complete all as specified.
Angle stop valve (Angle cocks), cast copper alloy, chromium plated with capstain head & cup, screwed down high pressure, screwed both ends for 15 mm bore iron pipe or for union, fixed in repair i.e., including taking down & removing old unserviceable stop cock from site complete all as specified.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe 15 mm bore and fixed in repairs i.e., including taking down & removing old unserviceable pillar cock from site complete all as specified.
S & F brass shower rose 125 mm size (Chromium plated) with swivel joint complete, suitable for 15 mm bore iron pipe complete fixed in repair including taking down & removing old unserviceable shower rose any type from site complete all as specified.
S & F Vitreous china squatting pan of Orissa patten size 580 x 440 white with integral foot rests and jointing to 'P' trap with cement joint and to flushing pipe/ anti-syphonage pipe, etc, (but excluding flushing cistern & flush pipe) fixed in repairs i.e., incl taking down carefully & removing old unserviceable Water Closet any pattern complete and making good to floor in CM 1:3 and removal of unserviceable material from site all as specified and as directed by Engineer incharge.
Vitreous china wash hand basin white flat back size 550 x 400 mm including PVC waste pipe 32 mm bore and CP Waste coupling with and incl a pair of suitable mild steel brackets, fixed all in repairs, including cutting for or pinning in and making good disturbed portion as reqd and removal of unserviceable material from site complete all as specified .
PVC valveless, syphonic action type flushing cistern, low level 10 ltr capicity Dual Flush Mechanic incl, PVC flush pipe 32 mm bore and mild steel brackets of angle iron 25 x 25 x 3 mm, oval all length 20 cm with red-oxide primer complete all as specified incl taking down any type of flushing cistern and making good the disturbed surfaces in CM 1:3 and removal of unserviceable material from site complete all as specified and directed.
S& F 450 to 600 mm long PVC connection with brass nuts on both ends for 15mm bore pipes of approved quality complete and fixed in repairs i.e., incl taking down & removing old unserviceable PVC connection any size from site complete all as specified and directed,
Taking up or down 15mm bore steel water tubing from trenches or walls etc. and removal from site complete all as directed
Taking up or down 20mm bore steel water tubing from trenches or walls etc. and removal from site complete all as directed
Refixing old serviceable steel tubing of 15 mm bore incl provn of new GI fittings such as Elbows, Tees, Sockets, unions etc., fixed in new or old position fixed to walls, ceiling or laid in floors etc., complete all as specified and as directed by Engineer incharge.
Refixing old serviceable steel tubing of 20 mm bore incl provn of new GI fittings such as Elbows, Tees, Sockets, unions etc., fixed in new or old position fixed to walls, ceiling or laid in floors etc., complete all as specified and as directed by Engineer incharge.
S & F Steel water tubing 15mm bore, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floor incl making connections with existing pipe if reqd at site complete all as specified and as directed by Engineer incharge.
S & F Steel water tubing 20mm bore, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floor incl making connections with existing pipe if reqd at site complete all as specified and as directed by Engineer incharge.
M & L for 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring finished even and smooth without using extra cementcomplete all as specifiedand as directed.
Glass dividing strips 38 mm wide and 3mm thick laid and fixed in position for laying floor finishes complete all as specified and directed.
M & L for RCC 1:2:4 type B-0 (12.5mm graded agg) as in shelves/ chajjas etc complete all as specified and directed.
M&L for TMT bars of 6 to 8mm dia cut to length bent to shape required and binding with and incl MS (annelead) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
Form work to soffits & sides of shelves/ Chhajjas and the like fair finished complete all as specified.
Demolition of Brick work including all quains and arches pillars etc built in cement mortar or cement lime mortar and removal of unserviceable material from site complete all as specified and directed.
M&L for brick work in cement mortar (1:6) using sub class 'B' old size bricks staight or curved on plan exc 6.0 m mean raidus complete all as specified and directed
50mm thick PCC (1:3:6) type C2 (using 40mm grade aggregate) as in plinth protection, finishing the surfaces even & smooth w/o using extra cement, all as specified and directed by Engineer-incharge.
75mm thick Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base under floors etc complete all as specified and as directed.
M &L for Rubber moulded Machine pressed precast concrete interlocking paver block(available in different colour for making patterns) any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with gray cement and pigment including laid over 25mm thick sand cushioning complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 using WPC as on sunken portion all as directed. Note: - Supply only WPC Shall be measured & paid separately as per manufacturers instructions.
M&L for applying three coats of brush bond acrylic based cementions material of approved quality for sunken treatment all as per manufactures instructions and providing 200 mm micron thick polythene film over 85/25 grade bitumen layer @ 0.5 Kg/Sqm all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for sunken portion and removal from site complete all as specified and directed.
Providing cement concrete 1:7:12 using brick aggregate of size 40 to 60 as in mass concrete/ filling of sunken portion complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified.
Demolition of mud phuska, in roof any thickness including leeping plastering (whether full, thickness removed or only a part thereof) and removal of waste material from site.
PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof padding, roof kerbs, mud stops, steps small sumps and like items slightly rounded or chamfered on the edges all as directed.
Providing and laying APP (Atactic polypropylene polymer) modified pre-fabricated five layer water proofing memorene 3 mm thick having weight not less than 3.60 kg/sqm black finished reinforced with non wooven polymer matt fix after applying one coat of cold applied solvant based bituminious primer @ 0,40 ltrs per sqm using botane torch and sealing all joint etc confirming to IS 3488 and cement plaster 15 mm thick in cm 1:3 all as per manufacturer instruction complete all as specified.
40mm thick brick tiles laid on cement mortar 15 mm thick in cm 1:6 jointed, grouted & pointed flush in separate operation in cm 1:3 mixed with 5% crude oil by weight of cement all as specified.
All as per item no 73 here-in-before but using old brick tiles (Old serviceable tiles as retrieved shall be reused under this item).
S&F 110 mm dia PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls with and including stack clamps made out of 40mm by 3mm FI and 12mm dia round iron stays and making good the disturbed portion in CM 1:3 to match with surrounding area, complete including taking down of old CI rain water pipe all as specified and directed.
S&F PVC ( HDPE) bends of any radius for 110 mm bore complete all as specified.
Cast iron soil waste and vent pipe of bore 100mm, sand cast, in any length with or without ears with run lead joints, laid in trenches or in floors, as in repair complete all as specified and directed.
All as per Serial Item No. 77 here-in-before but of bore 75mm
All as per Serial Item No. 77 here-in-before but of size 50mm bore, fixed to walls,
M&L Cast iron floor trap with 75mm dia out let with stainless steel grating including jointing with and including run lead, to waste pipe, as in repairs complete all as specified and directed.
S&F Cast iron bends (any radius) diminishing pieces or tapers of size of 100mm, as in repairs, with inspection eye including jointing with and including run lead complete all as specified and directed.
All as per item No 81 but bore of size 75mm complete all as specified and directed
Cast Iron branch pieces single (equal or unequal) ordinary or inverted, 100mm including with and including run lead inspection eye, as in repairs complete all as specified and directed.
All as per item No 83 but bore of size 75mm complete all as specified and directed
CI 'P' or 'S' trap suitable for 100mm bore pipe, including jointing with run lead at one end, fixed as in repairs complete all as specified and directed.
M&L for granite work (slab) 20 mm thick (table rubbed & polished) in steps, jambs, pillars, window cills, cooking plateforms, shelves and like (in single piece) laid over and incl 15mm thick screed bed in CM 1:4 and pointing in white cement (1:2) using granite dust with admixture of pigment to match with granite shade complete all as specified and directed
Chequered cement concrete tiles 20cm x 20cm x 25mm thick, with grey and pigment, machine pressed, set, jointed and pointed in neat cement slurry @ 3 Kg per SQM, in floors, over and including 15mm thick screed bed in cement mortar 1:4 incl taking down old one, complete all as specified and directed
S & F Stainless steel sink with drainage board made out of 1mm thick stainless stell sheet , kitchen type, with plug, wahser and waste pipe incl cantiliver brackets and connecting union to pipe over all size 915 x460mm, bowl size 410 x 330mm x 160mm
Curtain rod 32mm dia MS fancy with teak wood finish incl fixing brackets, stops of 2nd class hard wood with french polishetc complete etc all as specified & directed. (For the purpose of mesurement and payment running length of curtain rod only shall be considered.)
Taking down cement plaster or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal of debris from site complete all as specified and as directed
M & L for rendering 15mm thick cement plaster in cement mortar 1:4 using WPC on fair faces of brick or concrete surfaces on walls etc., finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge . Note: - Supply only WPC Shall be measured & paid separately as per manufacturers instructions.
M & L for rendering 10mm thick cement plaster in cement mortar 1:6 on fair faces of brick or concrete surfaces on walls etc., finished even and smooth without using extra cement, complete all as specified and directed.
M & L for Rendering 5mm thick cement plaster in CM 1:3 on concrete surfaces in ceiling/ Chhajjas finished even and smooth without using extra cement all as specified.
Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order.
Preparation of new plastered or unplastered surfaces of walls etc and applying two coat of distemper oil emulsion (OBD) over a coat of chalk whiting (as primer) complete all as specified and as directed.
M & L for Preparation of new plastered or unplastered surfaces of ceiling surfaces and applying three coat of lime white wash on ceiling surfaces all as specified.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using specified of emulsion and primer complete all as specified and directed.
Supply only liquid water prooing compound
Complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grinder complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location.
Taking down un- serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer – in – Charge.
Taking down ceiling fan of any descrptions, cleaning and servicing of fans as required, re-fixing again, connecting and testing the fan for its satisfactory function complete all as directed by Engineer – in – Charge.
Taking down exhasust fan of any descrptions, secleaning and servicing of fans as required, re-fixing again, connecting and testing the fan for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer – in – Charge.
Taking down elect water heater of any descrptions, re - fixing back, connecting and testing the geyser for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer – in – Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ complete all as specified and directed. in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
All as per item no 105 above but in existing conduit, complete all as specified and directed.
All as per serial item no 105 but for One light/fan point controlled by two way switch
All as per serial item no 105 but for One 3/5 pin socket outlet , 5 Amp on independent board
All as per serial item no 105 but for One 3/5 pin socket outlet , 5 Amp on same board
All as per serial item no 105 but for one bell /buzzer point controlled by one push button on independent board
M & L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.
M &L in replacement for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length)
Switch Modular type, 6 Amp, 240 Volts , one way complete fixed as in repair all as specified.
Switch Modular type, 6 Amp, 240 Volts , Two way complete fixed as in repair all as specified.
Switch Modular type, 16 Amp,240 Volts , one way complete fixed as in repair all as specified.
Socket outlet, Modular type, 6 Amp complete fixed as in repair all as specified.
Socket outlet, Modular type, 6 & 16 Amp complete fixed as in repair all as specified.
Bell Push, Modular type, 6 Amp complete fixed as in repair all as specified.
Fan regulator, modular type electronic step type complete fixed as in repair all as specified.
S & F ceiling rose surface bakelite two to three terminal 65 x 50 mm.
S&F in replacement Retrofit LED batten T-8 Tube light fittings 1 X 20 Watt, 4 ft long incl LED tube rod and incl 3 core flexible wire 0.5 Sqmm copper cable all as specified & directed.
S & F in replacement Tube light fittings LED type 1 X 10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
S & F in replacement LED bulk head fitting 6 watt with IP 43 in engineering plastic husing with clear plastic diffuser and making connection with PVC insulated copper conductor 3 core cable of size 0.75 Sq. mm, complete all as specified.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed.
S& F in bell ding dong operating on AC 230 volt single phase, complete all as specified and directed.
S & F MCB DB SPN 8 Way with acrylic double door complete all as specified and directed.
S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth bar including provision of MCCB, FP of 40 to 100 Amp conforing to IP 43 as incomer all as complete specified and directed. ( Note MCB,MCCB will be measured under seperate item)
S&F RCBO for earth leakage, short circuit and over load protection 240V , 32 Amps, Double pole, 30mA, complete all as specifed and directed.
S&F MCB SP 240V 6 to 32 Amps C series 10 KA, complete all as specifed and directed.
Taking Down the KWH meter along with wooden board / DB after removing all electrical connection and Refixing & connecting the same after wiring complete all as directed by Engr in Chargecomplete all as directed by Engineer in Charge.
Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accomodating electric energy meter including brick/cement works as per site requirement includiing flushing the box in walll and making good the disturbed portion of wall /surface complete alll as specified & directed by Engr in charge.
Supply laying jointing cable XLPE insulated PVC shetahted strip wire armoured 1100 volt 4 core 16 SQ mm multi stranded aluminium conductor laid in trenches/wall/ducts etcincluding necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2 mtr deep below ground level with top edgw of the plate not less than 1.4 mtr below normal ground level , connected earth wire 4 sqmm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type C-1 cast iron frame 50mm thick pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necesary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and funnel with watering pipe wire mesh copper lugs etc GI protection pipe of size 15 mm bore including testing complete all s specified & directed by Engr in Charge.
NARINDER KUMAR SONS
M/s Shakti Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .