Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.9 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.2 Cr+₹22.8 L (11.8%)Rejected-AOC NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹2.2 Cr+₹22.8 L (11.8%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹2.5 Cr+₹53.5 L (27.7%)Rejected-AOC | ₹2.5 Cr+₹53.5 L (27.7%) | L3 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
19 Mar 2024, 6:00 pmClosed
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
PROVISION OF LIFTS AT VARIOUS DEPARTMENT/ WARDS AT CHAF BANGALORE
2023_MES_615882_3
87401CWEAFNBAN
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) BANGALORE
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) BANGALORE
₹2.5 L
Yes
21 Jun 2024
2 Feb 2024
21 Mar 2024
2 Feb 2024
19 Mar 2024
7 Mar 2024
3 Feb 2024 - 7 Feb 2024
Amount
BOQ Dated
GENERAL SUMMARY NOTE : Schedule 'A' Part II to IX are prepriced by MES under Ser No. 1 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by Contractor for "Building or Works" as listed in Schedule Á' Part I
Lumpsum price worked out by Contractor for "Addition/ Alteration to building for Lifts" as listed in Schedule Á' Part II
Lumpsum price worked out by Contractor for "Internal Electric Supply" as listed in Schedule Á' Part III.
Lumpsum price worked out by Contractor for "Earthwork and Site clearance" as listed in Schedule Á' Part IV.
Lumpsum price worked out by Contractor for "Path/ Hardstanding" as listed in Schedule Á' Part V.
Lumpsum price worked out by Contractor for "Area Drainage" as listed in Schedule Á' Part VI.
Lumpsum price worked out by Contractor for "Sewage disposal" as listed in Schedule Á' Part VII.
Lumpsum price worked out by Contractor for "External water supply" as listed in Schedule Á' Part VIII.
Lumpsum price worked out by Contractor for "External Electric supply" as listed in Schedule Á' Part IX.
SCHEDULE Á' PART X Fittings / Fixtures and Misc Items ADDN/ALTN TO BUILDING FOR LIFT Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position, including concrete jalli work not otherwise specifically provided for. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Demolition of brick work or stone/boulder masonry, PCC block masonry built in cement mortar or cement lime mortar Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Demolition of cement concrete in floors and pavings not exc 15cm thick below or above ground level. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. [Quantity of 7 Cum is for Path/ hardstanding].
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the premises. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Taking down chowkhats or frames exc 4 sqm but not exc 8 sqm with shutter without taking of shutter from the frames including taking out hold fasts and PCC holdfast block all as specified and directed.
Taking up or down steel tubing and connections, fittings etc for 20mm bore complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work ( Ground floor to Third floor).
Taking up or down steel tubing and connections, fittings etc for 20mm bore complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work (Ground floor to Third floor).
AREA DRAINAGE Demolition of brick work or stone/boulder masonry, PCC block masonry built in cement mortar or cement lime mortar. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Demolition of cement concrete in floors and pavings not exc 15cm thick below or above ground level. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Dismantling of PVC drain pipes of 75/110mm bore, including all fittings, jointed in cement mortar and taking out of trenches, if required and removing from site of work complete all as directed.
SEWAGE DISPOSAL Demolition of plain cement concrete in foundation/copings/ bed concrete of drain pipes in any position all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Excavation in trenches not exceeding 1.5 meters wide and 1.5 meters in depth and getting out in any type of soil including cutting of roots any dia all as specified and directed.
EXTERNAL WATER SUPPLY Refixing Cast iron pipes 150mm with spigot and socket ends centrifugally cast Class A in any length retrieved from Ser item No 1 laid in trenches complete all as specified and as directed.
Dismantling including material and labour for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminous paint over a coat of red oxide primer on steel surfaces and necessary earth work in soft/loose soil complete all as specified and directed.
Dismantling and refixing Sluice valve cast iron body 150mm with brass spindle, class-1 ISI marked, PN-1.0, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete all as specified and as directed
(xv) Alarm button (xvi) Adjustable door open time (xvii) Car fan (xviii) Door open and door close buttons in car operating panel. (xix) Blower fan in car for ventilation (xx) Anti nuisance (empty car) (xxi) Emergency light (xxii) Infrared screen for car door (xxiii) Attendant control (xxiv) Home landing (xxv) Door closing retries (xxvi) Voice announcement unit in English language with music during operation time in car. (xxvii) Intercom system (xxviii) Motor overheat protection (xxix) Phase failure and phase reversal protection etc all specified by manufacturer
(xv) Alarm button (xvi) Adjustable door open time (xvii) Car fan (xviii) Door open and door close buttons in car operating panel. (xix) Blower fan in car for ventilation (xx) Anti nuisance (empty car) (xxi) Emergency light (xxii) Infrared screen for car door (xxiii) Attendant control (xxiv) Home landing (xxv) Door closing retries (xxvi) Voice announcement unit in English language with music during operation time in car. (xxvii) Intercom system (xxviii) Motor overheat protection (xxix) Phase failure and phase reversal protection etc all specified by manufacturer
(xv) Alarm button (xvi) Adjustable door open time (xvii) Car fan (xviii) Door open and door close buttons in car operating panel. (xix) Blower fan in car for ventilation (xx) Anti nuisance (empty car) (xxi) Emergency light (xxii) Infrared screen for car door (xxiii) Attendant control (xxiv) Home landing (xxv) Door closing retries (xxvi) Voice announcement unit in English language with music during operation time in car. (xxvii) Intercom system (xxviii) Motor overheat protection (xxix) Phase failure and phase reversal protection etc all specified by manufacturer
Supply and fix switch piano flush button SP two way 5 Amps, 240 V all as specified and directed.
Supply and fixing LED security light 25 watt made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK 07 including necessary clamp and GI bracket of 1 mtr bend to the shape of size 43mm dia. Make - Surya Lexon or equivalent model in Crompton/ Bajaj.
Supply and fix MCB distribution board sheet double door with Acrylic cover, powder coated DB's fitted with Bus bar, neutral link, earth bar and din rail of SPN 6 way 240 V, 200 Amps bus bar all as specified and directed.
PRACHANIVA CONSTRUCTIONS
B5BUILDING SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .