MR SE DURG 2 TAMAL LAL BHARTI(DFLT)
CE,DURG
Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt—Durg WITH ELECTRIFICATION WORK
201898
NIT NO. 356/Durg(Durg/2026
RESTRICTED TENDER
WORKS
PERCENTAGE
CE
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
5 documents required · 5 mandatory
Public Works Department (PWD)
WORKS
MR SE DURG 2 TAMAL LAL BHARTI(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C
CE,DURG
DURG,CIRCLE
DIVISION DURG
120
No
1
159491000
13102020
201898
3 Nov, 2026 5:30:00 PM IST
6 Nov, 2026 11:00:00 AM IST
15 Oct, 2026 7:30:00 PM IST
09102026
NIT NO. 356/Durg(Durg/2026
Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt—Durg WITH ELECTRIFICATION WORK
115000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
15301000.00
2
5 Nov, 2026 5:30:00 PM IST
15301000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
12
18d 22h 27m
W17471
5 documents required · 5 mandatory
₹0
₹1.1 L
15 Oct 2026
15 Oct 2026
6 Nov 2026
15 Oct 2026
5 Nov 2026
GOVERNMENT OF CHHATTISGARH
PUBLIC WORKS DEPARTMENT
Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.)
ESTIMATE FOR T.S.
AMOUNT OF ESTIMATE - Rs. 69.56 Lacs
OFFICE OF THE EXECUTIVE ENGINEER P.W.D. DURG, DIVISION - DURG
REPORT & SPECIFICATION
1 Name of work : Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.)
3 Amount of T.S. Estimate. : Rs. 69.56 Lakhs
4 Authority : Education Department of C.G. Govt.,New Raipur (C.G.)
5 Necessity : The term "DIET" typically stands for District Institute of Education and Training, an Indian government body providing teacher training and educational support at the district level, Presently this DIET College at Achhoti of Durg District is being developed as DIET-COE but in the Academic Building of DIET College is not sufficient . Therefore to provide these facilities, The State Council of Educational Research & Training, Chhattisgarh Government has been given the Administrative Approval by ordered No./परिषद्/समग्र शिक्षा/DIETCOE- 2ND/2025/3227, रायपुर दिनाँक-06/10/2025. So the estimate has been framed to cover the cost of these constuction work for Technical Sanction.
6 Provisions : The following provisions have been made in this Estimate.
1. SURFACE DRESSING
a) Surface dressing of the ground i/c removing, vegitation & making up undulations.
a) Foundation is designed with R.C.C. column rectangle column footing and excavated till the safe hard strata. Footing is designed till a depth of 2.5m with R.C.C. M-25 concrete and reinforcement confirming to TMT bar.
b) Plinth height is 90 cm.
c) Plinth is filled with moorum / sand with proper watering and ramming.
3. SUPER STRUCTURE
All R.C.C. framed structure with M-20 grade concrete and reinforcement confirming to TMT bar.
Form work of the structure is proposed with steel plates in the R.C.C. work.
Fly ash brick work of the plinthe & structure will be 200 mm thick in cement mortar 1:6
a) 6 mm thick plaster in chhajja ceiling in CM 1:3.
b) 12 mm thick plaster in internal walls in CM 1:5
c) 15 mm thick plaster in external walls in CM 1:5
7. FLOORING AND STONE WORK
a) Vitrified tiles & granite flooring.
b) Ceramic glazed wall tiles in skirting upto 2.10m level in toilet.
c) Ceramic glazed floor tiles on floor in toilet.
8. PAINTING & FINISHES
a) Internal walls - Acrylic premium emulsion paint.
b) External walls - Premium acrylic smooth exterior paint.
c) Door, Window & Shutter - Painting with Satin synthetic enamel paint.
9. DOOR & WINDOWS
a) Door frame, window frame & ventilator frame made of cold rolled pressed steel sheet and 35 mm thick flush door are provided with all necessary fittings .
b) Window & ventilator shutter made by aluminium with glazing .
10. WATER SUPPLY, DRAINAGE & SANITARY INSTALLATION, SEPTIC TANK
a) Water supply pipelines are provided in G.I. pipes and all drainage pipe line will be in PVC.
11. Rain Water Harvesting & Land scapping work.
13. Electrificatioin : Internal / External work.
7 Rates & Specifications Rates provided in this estimate are as per S.O.R. of Building work in force from 01.01.2015 & S.O.R. for road work w.e.f. 01.01.2015 and S.O.R. for Electrical & Mechanical work w.e.f. 01.07.2015 issued by E-in-C, CG P.W.D. Raipur and ammended upto date. The building work shall be executed as per C.P.W.D. Specification and the instruction issued by the department time to time and road work as per MORTH specifications.
Sub Engineer Sub Divisional Officer Executive Engineer
Sub Div. No.-3, Durg Sub Div. No.-3, Durg Durg Division, Durg
Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.)
GENERAL ABSTRACT
S.No. Sub Head Amount
1 Ground floor 1399907600
2 Water supply & Sanitary fittings 000 103848
3 Septic Tank 000 76564
B Electrification Works @ 10% of Civil Work 000 0 0.00 Lakhs
SAY Rs. 139.99 Lakhs 69.55873 70.43 Lakhs
Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.) 15301085.00 1399907600 7223615 6365.9
S.N. Depart ment SOR Year SOR Item DESCRIPTION Total Qtty UNIT RATE AMOUNT 153.01
1 2 3 4 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m WAITING and lead upto 50m (at least 5m away from the dressed area). 5850.00 sqm 7.20 42120.00
2 PWD Building 2015 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m WAITING and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
PWD Building 2015 1.1.1 In all types of soils. 1013.26 cum 185.00 187452.00
3 PWD Building 2015 1.6 Extra for every additional WAITING of 1.5 m or part thereof.
PWD Building 2015 1.6.1 All types of soils 128.73 cum 26.50 3411.00
4 PWD Building 2015 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and WAITING upto 1.5 M. 1013.26 cum 65.00 65862.00
5 PWD Building 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. 1094.92 cum 371.00 406214.00
6 PWD Building 2015 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
PWD Building 2015 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 208.96 cum 2970.00 620599.00
7 PWD Building 2015 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
PWD Building 2015 3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 541.93 cum 4163.00 2256055.00 1200522
8 PWD Building 2015 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
PWD Building 2015 3.12.2 Thermo-Mechanically treated bars FE 550D 55803.61 Kg 54.50 3041297.00
9 PWD Building 2015 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
PWD Building 2015 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 1038.92 sqm 139.00 144409.00
PWD Building 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape 827.04 sqm 297.00 245631.00
PWD Building 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) 1316.25 sqm 235.00 309319.00
PWD Building 2015 2.1.13 Weather shade, chhajja, Cornices and mouldings 193.83 sqm 294.00 56986.00
PWD Building 2015 2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings 43.37 sqm 230.00 9974.00
PWD Building 2015 2.1.8 Beams, lintels, cantilevers & walls 686.99 sqm 202.00 138771.00
9 PWD Building 2015 7.2 Brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in foundation and plinth in:
PWD Building 2015 7.2.1 Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) 9.22 cum 3722.00 34317.00
10 PWD Building 2015 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
PWD Building 2015 7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand) 271.81 cum 3263.00 886913.00
11 PWD Building 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. 3.19 cum 4237.00 13522.00
12 PWD Building 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 125.63 sqm 93.50 11746.00
#REF! PWD Building 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 286.31 cum 97.50 27915.00
PWD Building 2015 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 41.16 cum 195.00 8025.00
#REF! PWD Building 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 245.39 cum 121.00 29692.00
#REF! PWD Building 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. 25.20 sqm 3330.00 83916.00
#REF! PWD Building 2015 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate prime
PWD Building 2015 9.18.4 Single rebate/ mullion 100mm x50mm size, 1.6mm thick sheet. 207.60 meter 474.00 98402.00
#REF! PWD Building 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. 4865.40 Kg 67.50 328415.00
#REF! PWD Building 2015 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply eneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.
PWD Building 2015 8.12.1 35mm. thick (single leaf) 71.82 sqm 2005.00 143999.00
#REF! PWD Building 2015 8.15 Extra for double leaf shutter instead of single leaf. 65.52 sqm 52.00 3407.00
#REF! PWD Building 2015 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
PWD Building 2015 8.60.1 300x16mm 72.00 each 475.00 34200.00
#REF! PWD Building 2015 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
PWD Building 2015 8.62.2 200x10mm 60.00 each 231.00 13860.00
#REF! PWD Building 2015 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
PWD Building 2015 8.65.1 125 mm 98.00 each 55.50 5439.00
#REF! PWD Building 2015 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete. 70.00 each 44.00 3080.00
1 PWD Building 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. 60.00 each 346.00 20760.00
#REF! PWD Building 2015 8.152 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter).
PWD Building 2015 20.16 each 2318.00 46731.00
#REF! PWD Building 2015 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
PWD Building 2015 9.47.1 For fixed portion 430.11 kg 331.00 142366.00
PWD Building 2015 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). 430.11 kg 338.00 145377.00
#REF! PWD Building 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. 143.37 kg 27.00 3871.00
#REF! PWD Building 2015 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
PWD Building 2015 2 With float glass panes of 5 mm thickness 143.37 sqm 708.00 101506.00
#REF! PWD Building 2015 10.1 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm)
PWD Building 2015 10.1.1 1.00 mm thick sheet (weight 8.60 kg/m2) 45.56 sqm 964.00 43922.00
#REF! PWD Building 2015 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
PWD Building 2015 12.7.2 Size above 200x300mm 52.14 sqm 646.00 33682.00
#REF! PWD Building 2015 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
PWD Building 2015 12.9.2 Size above 300x300mm 204.86 sqm 728.00 149134.00
#REF! PWD Building 2015 12.74 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete.
PWD Building 2015 12.74.3 Size 600x600mm thickness 7 to 8 mm 1180.63 sqm 897.00 1059025.00
#REF! PWD Building 2015 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
PWD Building 2015 12.46.2 Granite stone black 48.18 sqm 2719.00 131001.00
#REF! PWD Building 2015 12.44 Extra for nosing in Granite stone for treads. 115.20 meter 126.00 14515.00
#REF! PWD Building 2015 12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.
PWD Building 2015 12.3.1 40 mm thick 207.00 sqm 222.00 45954.00
PWD Building 2015 12.3.2 50 mm thick 8.00 sqm 254.00 2032.00
#REF! PWD Building 2015 10.53 Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately)
PWD Building 2015 10.53.1 Flat surface 300.72 sqm 849.00 255311.00
PWD Building 2015 10.53.2 Curved surface 300.72 sqm 895.00 269144.00 #REF!
#REF! PWD Building 2015 60. 10.58 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above. 180.43 sqm 457.00 82457.00
#REF! PWD Building 2015 11.1 Providing and making 6mm thick cement plaster of mix:
PWD Building 2015 11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand) 1162.48 sqm 93.00 108111.00
#REF! PWD Building 2015 11.2 Providing and making 12mm thick cement plaster of mix:
PWD Building 2015 11.2.1 In cement Mortar 1:3 (1 cement : 3 fine sand) 32.40 sqm 115.00 3726.00
PWD Building 2015 11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand) 3034.24 sqm 96.50 292804.00
#REF! PWD Building 2015 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
PWD Building 2015 11.3.3 In Cement Mortar 1:5 (1 cement : 5 fine sand) 2083.07 sqm 113.00 235386.00
#REF! PWD Building 2015 11.33 Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
PWD Building 2015 11.33.1 12 mm thick 590.00 meter 4.20 2478.00
#REF! PWD Building 2015 11.5 Neat Cement punning. 32.40 sqm 33.00 1069.00
#REF! PWD Building 2015 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. 2.80 Kg 43.50 122.00
#REF! PWD Building 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and WAITINGs etc. complete before plastering upto 10mts in height. 142.80 sqm 86.00 12281.00
#REF! PWD Building 2015 Ammendment No-08 14.54 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
PWD Building 2015 14.54.1 Upto 2 mm thickness to make surface even and smooth in line and level. 4196.72 sqm 82.00 344131.00
#REF! PWD Building 2015 Ammendment No-08 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth & even with all tools tackles and labour etc. complete for the work. 2083.07 sqm 86.00 179144.00
#REF! PWD Building 2015 Ammendment No-08 14.59 Providing and applying polymeric cement primer on all surface applied @ 0.80litrs/10 sqm as pe relevant IS code 15489:1974 (product such as Birla white prime coat/activcoat, Asian trucare, Dulux interior cement primer, Opus Calista/110) with all tools tackles and labour etc. complete for the work. 6279.79 sqm 29.00 182114.00
#REF! PWD Building 2015 Ammendment No-08 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats applied @1.25 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -1 Class D & C(Glossy & Semi Glossy Finish) of required shed (product such as Tractor emulsion, Dulux Promise, Nerolac Beauty Silver, Berger bison/breeze, Opus 130/Style Paint) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty) 4196.72 sqm 74.00 310557.00
#REF! PWD Building 2015 Ammendment No-08 14.67 Providing and applying on exterior surface with ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @1.43 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -2 Class D & C (Glossy & Semi Glossy Finish) (Product such as Asian ACE , Dulux Promise exterior, Berger wall Masta, Nerolac Suraksha Plus, Nippon Shogun Opus, One Style Power Bright) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty) 2083.07 sqm 70.00 145815.00
#REF! PWD Building 2015 Ammendment No-08 14.72 Providing and applying Glossy Finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10 Sqm upto final finish as per relevant IS Code 2932:2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthetic Enamel, Opus Prime Enamel) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. 912.89 sqm 120.00 109547.00
#REF! PWD Building 2015 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
PWD Building 2015 9.57.2 SS Grade 304 93.02 Kg 525.00 48833.00
1 PWD Building 2015 18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
PWD Building 2015 18.4.1 White pedestal type 5.00 each 2882.00 14410.00
2 PWD Building 2015 18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :
PWD Building 2015 18.17.1 White Size 550x450 mm 4.00 each 1430.00 5720.00
3 PWD Building 2015 18.25 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
PWD Building 2015 18.25.1 32 mm dia 4.00 each 68.50 274.00
4 PWD Building 2015 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 4.00 each 599.00 2396.00
5 PWD Building 2015 18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.
PWD Building 2015 18.76.1 75 mm dia pipe. 54.00 metre 182.00 9828.00
PWD Building 2015 18.76.2 110 mm dia pipe. 88.00 metre 267.00 23496.00
6 PWD Building 2015 18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
PWD Building 2015 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90°
PWD Building 2015 18.77.2 Double "Y" with or without door
PWD Building 2015 18.77.3 Vent covel
PWD Building 2015 18.77.3.2 110 mm 2.00 each 44.00 88.00
PWD Building 2015 18.77.4 Access door cap
PWD Building 2015 18.77.4.1 75 mm 4.00 each 49.50 198.00
PWD Building 2015 18.77.6 Nahani trap 110x75mm 8.00 each 90.50 724.00
7 PWD Building 2015 18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
PWD Building 2015 18.78.1 75 mm 40.00 each 57.00 2280.00
8 PWD Building 2015 19.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
PWD Building 2015 19.4.3 25 mm nominal outer dia .Pipes. 50.00 metre 199.00 9950.00
PWD Building 2015 19.4.4 32 mm nominal outer dia .Pipes. 34.00 metre 271.00 9214.00
PWD Building 2015 19.4.5 40 mm nominal outer dia .Pipes. 50.00 metre 362.00 18100.00
9 PWD Building 2015 19.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
PWD Building 2015 CONCEALED WORK including cutting chases and making good the walls etc.,
PWD Building 2015 19.5.1 15 mm nominal outer dia .Pipes. 50.00 metre 133.00 6650.00
PWD Building 2015 19.5.3 25 mm nominal outer dia .Pipes. 72.00 metre 213.00 15336.00
10 PWD Building 2015 19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality:
PWD Building 2015 19.13.2 Bib cock (350 grams) 8.00 each 237.00 1896.00
PWD Building 2015 19.13.3 Stop cock (350 grams) 8.00 each 237.00 1896.00
11 PWD Building 2015 19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
PWD Building 2015 19.14.2 Long nose bib cock (500 grams) 4.00 each 455.00 1820.00
PWD Building 2015 19.14.4 Piller Cock (400 grams) 4.00 each 398.00 1592.00
PWD Building 2015 19.14.16 Towel rail (600mm long x 20mm dia) 4.00 each 338.00 1352.00
PWD Building 2015 19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) 4.00 each 774.00 3096.00
12 PWD Building 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 8.00 each 51.00 408.00
13 PWD Building 2015 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
PWD Building 2015 19.16.1 25 mm nominal bore 4.00 each 436.00 1744.00
PWD Building 2015 19.16.3 40 mm nominal bore 4.00 each 596.00 2384.00
14 PWD Building 2015 19.17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
19.17.3 25 mm nominal bore 2.00 each 432.00 864.00
15 PWD Building 2020 19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same : 30.00 each 125.00 3750.00
16 PWD Building 2020 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 4.00 each 4644.00 18576.00
17 PWD Building 2020 19.49 Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 4.00 each 8013.00 32052.00
18 PWD Building 2020 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 2000.00 litre 7.30 14600.00
Electrification (E&M) : #REF! 6955873 7032948 13988821 -13988821
1 PWD ELECT 2020 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)) 1.7.1 Short Point 39 Point 266.00 10374.00
2 PWD ELECT 2020 1.7.2 Medium Point 78 Point 424.00 33072.00
3 PWD ELECT 2020 1.7.3 Long Point 250 Point 350.00 87500.00
4 PWD ELECT 2020 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 4 Point 420.00 1680.00
5 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 90 Point 216.00 19440.00
6 PWD ELECT 2020 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point 8 Point 442.00 3536.00
7 PWD ELECT 2020 1.10.3 Long Point 7 Point 922.00 6454.00
8 PWD ELECT 2020 1.10.4 Extra Long Point I 8 Point 1302.00 10416.00
9 PWD ELECT 2020 1.10.5 Extra Long Point II 9 Point 1657.00 14913.00
10 PWD ELECT 2020 1.10.6 Extra Long Point III 7 Point 1995.00 13965.00
11 PWD ELECT 2020 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)1.11.3 Long Point 2 Point 1350.00 2700.00
12 PWD ELECT 2020 1.5.4 Extra Long Point I 2 Point 1807.00 3614.00
13 PWD ELECT 2020 1.5.5 Extra Long Point II 1 Point 2315.00 2315.00
14 PWD ELECT 2020 1.5.6 Extra Long Point Ill 3 Point 2825.00 8475.00
15 PWD ELECT 2020 1.12 Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5).1.12.4 Extra Long Point 1 2 Point 2326.00 4652.00
16 PWD ELECT 2020 1.12.5 Extra Long Point II 2 Point 3016.00 6032.00
17 PWD ELECT 2020 1.12.6 Extra Long Point III 3 Point 3708.00 11124.00
18 PWD ELECT 2020 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1. 3 X 1.5 sq. mm in 20mm conduit 269 Point 92.00 24748.00
19 PWD ELECT 2020 1.13.2 3 X 2.5 sq. mm in 20mm conduit 400 Point 111.00 44400.00
20 PWD ELECT 2020 1.13.3 6 X 2.5 sq. mm in 25mm conduit 300 Point 172.00 51600.00
21 PWD ELECT 2020 1.13.4 9 X 2.5 sq. mm in 32mm conduit 83 Point 238.00 19754.00
22 PWD ELECT 2020 1.13.5 12 X 2.5 sq. mm in 32mm conduit 26 Point 288.00 7488.00
23 PWD ELECT 2020 1.13.6 3 X 4 sq. mm in 25mm conduit 150 Point 145.00 21750.00
24 PWD ELECT 2020 1.13.7 3 X 6 sq. mm in 25mm conduit 15 Metre 182.00 2730.00
25 PWD ELECT 2020 1.13.13 6 X 6 sq. mm in 32mm conduit 97 Metre 312.00 30264.00
26 PWD ELECT 2020 1.13.14 6 X 10 sq. mm in 40mm conduit 88 Metre 515.00 45320.00
27 PWD ELECT 2020 1.13.15 6 X 16 sq. mm in 50mm conduit 15 Metre 772.00 11580.00
28 PWD ELECT 2020 2.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5)2.15.1 20 mm 125 Metre 32.00 4000.00
30 PWD ELECT 2020 3.12 Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.12.2 2 pair 180 Metre 11.00 1980.00
31 PWD ELECT 2020 3.13 Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.13.1 RG-6 grade 180 Metre 14.00 2520.00
32 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification.. 5.4.9. Fan regulator (two module size) electronic stepped type moving all rounds 86 Point 223.00 19178.00
33 PWD ELECT 2020 5.4.12 Plug Top (Deluxe type) 3 pin 25 Amps (For power plug). 4 Point 74.00 296.00
34 2020 5.4.15 Telephone socket outlet 6 Each 70.00 420.00
35 2020 5.4.16 T.V. antenna socket outlet 2 Each 74.00 148.00
36 2020 5.4.17 Computer Outlet Jack 11 Each 242.00 2662.00
37 PWD ELECT 2020 5.4.18 25/32 amp A.C. Starter switch 7 Each 246.00 1722.00
38 PWD ELECT 2026 5.4.20 Ceiling rose 3 pin 5 amp 103 Each 40.00 4120.00
39 PWD ELECT 2020 5.4.22 Batten/ angle holder 68 Each 41.00 2788.00
40 PWD ELECT 2020 5.4.23 Blanking plate 120 Each 28.00 3360.00
41 PWD ELECT 2020 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. 11 Each 816.00 8976.00
42 PWD ELECT 2020 5.7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification.5.7.2) Delux 10 Point 107.00 1070.00
43 PWD ELECT 2020 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. 96 Point 42.00 4032.00
44 PWD ELECT 2020 5.10 Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification. 96 Point 109.00 10464.00
45 PWD ELECT 2020 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments.6.1.3)1200 mm sweep 83 Point 1697.00 140851.00
46 PWD ELECT 2020 6.11 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11..2)60 cm long 85 Point 40.00 3400.00
47 PWD ELECT 2020 6.11.3 90 cm long 11 Each 58.00 638.00
48 PWD ELECT 2020 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan) 96 Point 56.00 5376.00
49 PWD ELECT 2020 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1) 300 mm sweep 25 Point 2446.00 61150.00
50 PWD ELECT 2020 6.8 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.2) 300 mm sweep 2 Point 1270.00 2540.00
51 PWD ELECT 2020 6.15 Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.6.15.6) 18/20 Watt 19 Each 868.00 16492.00
52 PWD ELECT 2020 6.16 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.6.16.1 24 watt, size 300 x 300mm 8 Each 1775.00 14200.00
53 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.6.19.3) 18/20 watt {4 feet} 148 Point 443.00 65564.00
54 PWD ELECT 2020 6.17 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt6.17.4). 9 Watt 50 Point 143.00 7150.00
55 PWD ELECT 2020 6.17.6 15 Watt 18 Point 249.00 4482.00
56 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt6.28.7).60 watt 10 Point 3622.00 36220.00
58 PWD ELECT 2020 6.48 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 96 Point 10.00 960.00
59 PWD ELECT 2020 6.50 Providing and fixing wooden board of suitable size for energy meter etc complete as required. 2 Point 123.00 246.00
60 PWD ELECT 2020 7.10 Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately)7.10.2 .63 amps 5 Point 1915.00 9575.00
61 PWD ELECT 2020 7.11 Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately).7.11.3) 63 amps 6 Point 162.00 972.00
62 PWD ELECT 2020 9.4 Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator)9.4.4) 4 way Double door 5 Point 1716.00 8580.00
63 PWD ELECT 2020 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification9.11.2) .6 amps to 32 amps 60 Point 148.00 8880.00
64 PWD ELECT 2020 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification 9.16.5) .63 amps 4 Point 1316.00 5264.00
65 PWD ELECT 2020 9.18 Supplying and fixing 4 Pole MCB, 440 volts in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.9.18.2)100 amps 1 Point 5721.00 5721.00
66 PWD ELECT 2020 9.20 Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.9.20.2) 63 amps 2 Point 621.00 1242.00
67 PWD ELECT 2020 12.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) 5 Set 3243.00 16215.00
68 PWD ELECT 2020 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) 2 Point 6209.00 12418.00
69 PWD ELECT 2020 12.4 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification. 65 Point 77.00 5005.00
70 PWD ELECT 2020 12.12 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification. 130 Point 36.00 4680.00
71 PWD ELECT 2020 12.20 Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres 16.5 Cum 168.00 2772.00
72 PWD ELECT 2020 14.1 Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification14.1.1) .63 mm outer dia and 50 mm Inner dia 165 Point 184.00 30360.00
73 PWD ELECT 2020 15.1 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1)15.1.11).3.5x25 sq. mm 200 Point 315.00 63000.00
74 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification.15.23.13) 3½ X 35 sq. mm (28 mm) 8 Point 153.00 1224.00
76 PWD ELECT 2020 24.7 Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification 24.7.2.5 KVA 4 Each 4367.00 17468.00
77 PWD ELECT 2020 24.10 Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification24.10.1) 5/8 " 30 Metre 375.00 11250.00
79 PWD ELECT 2020 23.3 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant23.3.3 ) .2.0 HP, single phase 2 Each 19805.00 39610.00
80 PWD ELECT 2020 23.6 Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification 23.6.2 ) .50 mm outer dia 405 Metre 118.00 47790.00
81 PWD ELECT 2020 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set 2 Each 4030.00 8060.00
82 PWD ELECT 2020 23.12 Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification. 4 Metre 291.00 1164.00
83 PWD ELECT 2020 23.13 Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification 2 Each 388.00 776.00
84 PWD ELECT 2020 23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant.23.14.2) 3x2.5 sqmm 430 Metre 64.00 27520.00
85 PWD ELECT 2020 24.24 Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification.25.24.1) 25 Ltrs/hr output capacity 1 Each 23508.00 23508.00
86 PWD ELECT 2020 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. 63 Point 168.00 10584.00
TOTAL AMOUNT 15301085
Sub - Engineer Sub-Divisional Officer Executive Engineer
P.W.D. Sub Dn.3 Durg P.W.D. Sub Dn.3 Durg P.W.D. Durg Division, Durg
Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.) 13999076.00 1399907600 7223615 6365.9
S.N. SOR Item DESCRIPTION QTY. (ACD) Septic Tank QTY.(ADM) Total Qtty UNIT RATE AMOUNT 13988821
Depart ment SOR Year 10255
1 2 3 4 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m WAITING and lead upto 50m (at least 5m away from the dressed area). 2925.00 21060.00 0.00 2925.00 21060.00 0.00 5850.00 5850.00 sqm 7.20 42120.00
2 PWD Building 2015 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m WAITING and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 0.00 0.00 0.00 0.00
3 PWD Building 2015 1.6 Extra for every additional WAITING of 1.5 m or part thereof. 0.00 0.00 0.00 0.00
4 PWD Building 2015 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and WAITING upto 1.5 M. 479.21 31148.65 29.841 1939.67 504.21 32773.46 0.00 1013.26 1013.26 cum 65.00 65862.00
5 PWD Building 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. 809.423 300295.93 12.6435 4690.74 272.85 101227.07 0.00 1094.92 1094.92 cum 371.00 406214.00
6 PWD Building 2015 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 0.00 0.00 0.00 0.00
PWD Building 2015 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 101.712 302084.64 2.1315 6330.56 101.66 301919.81 3.46 10264.32 208.96 208.96 cum 2970.00 620599.00
7 PWD Building 2015 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 0.00 0.00 0.00 0.00
8 PWD Building 2015 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 0.00 0.00 0.00 0.00
9 PWD Building 2015 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 0.00 0.00 0.00 0.00
PWD Building 2015 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 512.69 71263.91 9.8 1362.20 516.42 71783.08 0.00 1038.92 1038.92 sqm 139.00 144409.00
PWD Building 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape 343.44 102001.68 0.00 303.48 90133.56 180.12 53495.64 827.04 827.04 sqm 297.00 245631.00
PWD Building 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) 596.25 140118.75 0.00 525.25 123433.75 194.75 45766.25 1316.25 1316.25 sqm 235.00 309319.00
PWD Building 2015 2.1.13 Weather shade, chhajja, Cornices and mouldings 104.38 30687.72 0.00 63.14 18563.16 26.31 7735.14 193.83 193.83 sqm 294.00 56986.00
PWD Building 2015 2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings 21.6825 4986.98 0.00 21.68 4986.98 0.00 43.37 43.37 sqm 230.00 9974.00
9 PWD Building 2015 7.2 Brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in foundation and plinth in: 0.00 0.00 0.00 0.00
PWD Building 2015 7.2.1 Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) 0 0.00 9.22 34316.84 0.00 0.00 9.22 9.22 cum 3722.00 34317.00
10 PWD Building 2015 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in: 0.00 0.00 0.00 0.00
11 PWD Building 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. 1.5605 6611.84 0.00 1.63 6910.55 0.00 3.19 3.19 cum 4237.00 13522.00
12 PWD Building 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 65.01 6078.44 0.00 60.62 5667.97 0.00 125.63 125.63 sqm 93.50 11746.00
#REF! PWD Building 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 161.061 15703.45 0.00 125.25 12211.70 0.00 286.31 286.31 cum 97.50 27915.00
PWD Building 2015 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 0.00 0.00 0.00 0.00 41.16 41.16 cum 195.00 8025.00
#REF! PWD Building 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 87.032 10530.87 0.00 118.45 14331.85 39.91 4828.87 245.39 245.39 cum 121.00 29692.00
#REF! PWD Building 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. 18 59940.00 0.00 7.20 23976.00 0.00 25.20 25.20 sqm 3330.00 83916.00
#REF! PWD Building 2015 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate prime 0.00 0.00 0.00 0.00
PWD Building 2015 9.18.4 Single rebate/ mullion 100mm x50mm size, 1.6mm thick sheet. 100 47400.00 0.00 78.80 37351.20 28.80 13651.20 207.60 207.60 meter 474.00 98402.00
#REF! PWD Building 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. 3445.2 232551.00 0.00 1015.20 68526.00 405.00 27337.50 4865.40 4865.40 Kg 67.50 328415.00
#REF! PWD Building 2015 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply eneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 8.15 Extra for double leaf shutter instead of single leaf. 30.24 1572.48 0.00 25.20 1310.40 10.08 524.16 65.52 65.52 sqm 52.00 3407.00
#REF! PWD Building 2015 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete. 26 1144.00 0.00 22.00 968.00 22.00 968.00 70.00 70.00 each 44.00 3080.00
1 PWD Building 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. 0 0.00 0.00 45.00 15570.00 15.00 5190.00 60.00 60.00 each 346.00 20760.00
#REF! PWD Building 2015 8.152 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). 0 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: 0.00 0.00 0.00 0.00
PWD Building 2015 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). 217.08 73373.04 0.00 152.28 51470.64 60.75 20533.50 430.11 430.11 kg 338.00 145377.00
#REF! PWD Building 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. 72.36 1953.72 0.00 50.76 1370.52 20.25 546.75 143.37 143.37 kg 27.00 3871.00
#REF! PWD Building 2015 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 0.00 0.00 0.00 0.00
PWD Building 2015 2 With float glass panes of 5 mm thickness 72.36 51230.88 0.00 50.76 35938.08 20.25 14337.00 143.37 143.37 sqm 708.00 101506.00
#REF! PWD Building 2015 10.1 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm) 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 12.74 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 12.44 Extra for nosing in Granite stone for treads. 57.6 7257.60 0.00 57.60 7257.60 0.00 115.20 115.20 meter 126.00 14515.00
#REF! PWD Building 2015 12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 10.53 Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately) 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 60. 10.58 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above. 87.12 39813.84 0.00 67.51 30852.98 25.80 11790.60 180.43 180.43 sqm 457.00 82457.00
#REF! PWD Building 2015 11.1 Providing and making 6mm thick cement plaster of mix: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 11.2 Providing and making 12mm thick cement plaster of mix: 0.00 0.00 0.00 0.00
PWD Building 2015 11.2.1 In cement Mortar 1:3 (1 cement : 3 fine sand) 0.00 32.4 3726.00 0.00 0.00 32.40 32.40 sqm 115.00 3726.00
#REF! PWD Building 2015 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 11.33 Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 0.00 0.00 0.00 0.00
#REF! PWD Building 2015 11.5 Neat Cement punning. 0.00 32.4 1069.20 0.00 0.00 32.40 32.40 sqm 33.00 1069.00
#REF! PWD Building 2015 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. 0.00 2.79936 121.77 0.00 0.00 2.80 2.80 Kg 43.50 122.00
#REF! PWD Building 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and WAITINGs etc. complete before plastering upto 10mts in height. 36 3096.00 0.00 67.20 5779.20 39.60 3405.60 142.80 142.80 sqm 86.00 12281.00
#REF! PWD Building 2015 Ammendment No-08 14.54 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete 0.00 0.00 0.00 0.00
PWD Building 2015 14.54.1 Upto 2 mm thickness to make surface even and smooth in line and level. 1764.74 144708.68 0.00 1704.84 139796.72 727.14 59625.73 4196.72 4196.72 sqm 82.00 344131.00
#REF! PWD Building 2015 Ammendment No-08 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth & even with all tools tackles and labour etc. complete for the work. 922.61 79344.46 0.00 690.44 59377.84 470.02 40421.29 2083.07 2083.07 sqm 86.00 179144.00
#REF! PWD Building 2015 Ammendment No-08 14.59 Providing and applying polymeric cement primer on all surface applied @ 0.80litrs/10 sqm as pe relevant IS code 15489:1974 (product such as Birla white prime coat/activcoat, Asian trucare, Dulux interior cement primer, Opus Calista/110) with all tools tackles and labour etc. complete for the work. 2687.35 77933.15 0.00 2395.28 69463.06 1197.16 34717.58 6279.79 6279.79 sqm 29.00 182114.00
#REF! PWD Building 2015 Ammendment No-08 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats applied @1.25 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -1 Class D & C(Glossy & Semi Glossy Finish) of required shed (product such as Tractor emulsion, Dulux Promise, Nerolac Beauty Silver, Berger bison/breeze, Opus 130/Style Paint) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty) 1764.74 130590.76 0.00 1704.84 126158.01 727.14 53808.58 4196.72 4196.72 sqm 74.00 310557.00
#REF! PWD Building 2015 Ammendment No-08 14.67 Providing and applying on exterior surface with ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @1.43 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -2 Class D & C (Glossy & Semi Glossy Finish) (Product such as Asian ACE , Dulux Promise exterior, Berger wall Masta, Nerolac Suraksha Plus, Nippon Shogun Opus, One Style Power Bright) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty) 922.61 64582.70 0.00 690.44 48330.80 470.02 32901.05 2083.07 2083.07 sqm 70.00 145815.00
#REF! PWD Building 2015 Ammendment No-08 14.72 Providing and applying Glossy Finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10 Sqm upto final finish as per relevant IS Code 2932:2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthetic Enamel, Opus Prime Enamel) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. 464.436 55732.32 0.00 353.74 42448.32 94.72 11365.92 912.89 912.89 sqm 120.00 109547.00
#REF! PWD Building 2015 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. 0.00 0.00 0.00 0.00
1 PWD Building 2015 18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 0.00 0.00 0.00 0.00
2 PWD Building 2015 18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 0.00 0.00 0.00 0.00
3 PWD Building 2015 18.25 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 0.00 0.00 0.00 0.00
4 PWD Building 2015 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 2 1198.00 0.00 0.00 2.00 1198.00 4.00 4.00 each 599.00 2396.00
5 PWD Building 2015 18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 0.00 0.00 0.00 0.00
6 PWD Building 2015 18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 0.00 0.00 0.00 0.00
PWD Building 2015 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 0.00 0.00 0.00 0.00
PWD Building 2015 18.77.2 Double "Y" with or without door 0.00 0.00 0.00 0.00
PWD Building 2015 18.77.3 Vent covel 0.00 0.00 0.00 0.00
PWD Building 2015 18.77.4 Access door cap 0.00 0.00 0.00 0.00
7 PWD Building 2015 18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 0.00 0.00 0.00 0.00
8 PWD Building 2015 19.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 0.00 0.00 0.00 0.00
PWD Building 2015 19.4.3 25 mm nominal outer dia .Pipes. 25 4975.00 0.00 0.00 25.00 4975.00 50.00 50.00 metre 199.00 9950.00
PWD Building 2015 19.4.4 32 mm nominal outer dia .Pipes. 17 4607.00 0.00 0.00 17.00 4607.00 34.00 34.00 metre 271.00 9214.00
PWD Building 2015 19.4.5 40 mm nominal outer dia .Pipes. 25 9050.00 0.00 0.00 25.00 9050.00 50.00 50.00 metre 362.00 18100.00
9 PWD Building 2015 19.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 0.00 0.00 0.00 0.00
PWD Building 2015 CONCEALED WORK including cutting chases and making good the walls etc., 0.00 0.00 0.00 0.00
PWD Building 2015 19.5.1 15 mm nominal outer dia .Pipes. 25 3325.00 0.00 0.00 25.00 3325.00 50.00 50.00 metre 133.00 6650.00
PWD Building 2015 19.5.3 25 mm nominal outer dia .Pipes. 36 7668.00 0.00 0.00 36.00 7668.00 72.00 72.00 metre 213.00 15336.00
10 PWD Building 2015 19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: 0.00 0.00 0.00 0.00 0.00 0.00
11 PWD Building 2015 19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 0.00 0.00 0.00 0.00
PWD Building 2015 19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) 2 1548.00 0.00 0.00 2.00 1548.00 4.00 4.00 each 774.00 3096.00
12 PWD Building 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 4 204.00 0.00 0.00 4.00 204.00 8.00 8.00 each 51.00 408.00
13 PWD Building 2015 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 0.00 0.00 0.00 0.00
14 PWD Building 2015 19.17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 0.00 0.00 0.00 0.00
15 PWD ELECT 2020 19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same : 15 1875.00 0.00 0.00 15.00 1875.00 30.00 30.00 each 125.00 3750.00
16 PWD ELECT 2020 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 2 9288.00 0.00 0.00 2.00 9288.00 4.00 4.00 each 4644.00 18576.00
17 PWD ELECT 2020 19.49 Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 2 16026.00 0.00 0.00 2.00 16026.00 4.00 4.00 each 8013.00 32052.00
18 PWD ELECT 2020 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1000 7300.00 0.00 0.00 1000.00 7300.00 2000.00 2000.00 litre 7.30 14600.00 0
PWD ELECT 2020 Rs: 139.99
Detailed Estimate for Consrtuction of Additional Room (Administrative Block) in DIET College at Achhoti, Distt--Durg (C.G.) 1480103.00 703294800 -6.18 Lakhs
S.N. SOR Item DESCRIPTION Measurment QTY. UNIT RATE AMOUNT
NO. L W H. / D.
1 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
2 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Chhajja over Window W1 7 2.10 0.60 0.10 0.88
Ventilator Chhajja V1 2 0.80 0.60 0.10 0.10
Roof Slab with projection 1 180.00 0.125 22.50
Column upto Parapet top C0 2 0.30 0.30 0.90 0.16
Column upto Slab top C1 19 0.20 0.45 3.60 6.16
Column upto Tower Room 4 0.20 0.45 3.00 1.08
3 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Qtty same as Previous item TOTAL: 41.16 cum 195.00 8025.00
4 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D Taking '@ 100 Kg/cum of RCC 4115.60 Kg 54.50 224300.00
5 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
Upto Slab Top :
Upto TR Slab Top :
2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Roof Slab with projection 1 180.00 180.00
2.1.13 Weather shade, chhajja, Cornices and mouldings
Chhajja over Window W1 7 2.10 0.60 8.82
OTS Chhajja 1 17.20 0.60 10.32
Ventilator Chhajja V1 2 0.80 0.60 0.96
2.1.8 Beams, lintels, cantilevers & walls
Lintel beam 1x2 66.80 0.20 26.72
Slab Beam 1x2 66.80 0.45 60.12
6 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work above pilnth 1 66.80 0.20 2.90 38.74
Parapet Wall 1 49.70 0.20 0.90 8.95
7 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Qtty same as above 39.91 cum 121.00 4829.00
8 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate prime
9.18.4 Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.
9 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
10 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply eneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.
8.12.1 35mm. thick (single leaf)
11 8.15 Extra for double leaf shutter instead of single leaf.
12 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
13 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
14 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
TOTAL: 14.00 each 55.50 777.00
15 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
TOTAL: 22.00 each 44.00 968.00
16 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.
TOTAL: 15.00 meter 346.00 5190.00
17 8.152 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter).
8.152.1 PVC door shutter
18 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
9.47.1 For fixed portion
9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
19 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
AS PER ITEM NO.9.47 TOTAL: 20.25 kg 27.00 547.00
20 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
2 With float glass panes of 5 mm thickness
21 10.1 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm)
10.1.1 1.00 mm thick sheet (weight 8.60 kg/m2)
22 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.2 Size above 200x300mm
23 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
12.9.2 Size above 300x300mm
24 12.74 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete.
12.74.3 Size 600x600mm thickness 7 to 8 mm
Multipurpose Hall 1 12.20 5.00 61.00
RC/TLC & MD CELL 1 5.00 5.00 25.00
25 10.53 Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately)
10.53.1 Flat surface
Multipurpose Hall 1 12.20 5.00 61.00
RC/TLC & MD CELL 1 5.00 5.00 25.00
Taking 50 % of above 43.00 sqm 849.00 3650700 36507
10.53.2 Curved surface Qtty same as above 43.00 sqm 895.00 3848500 38485
26 10.58 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above.
Multipurpose Hall 1 12.20 5.00 61.00
RC/TLC & MD CELL 1 5.00 5.00 25.00
Taking 30 % of above 25.80 sqm 457.00 1179100 11790.6
27 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand)
Multipurpose Hall 1 12.20 5.00 61.00
RC/TLC & MD CELL 1 5.00 5.00 25.00
Beam Offsets 9x2 5.00 0.35 31.50
28 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Beam Offsets 6x2 4.75 0.35 19.95 5.00
Column Offset 6x2 0.25 3.60 10.80 3.60 1.50
Taking 50% Qtty of above (B) 18.41
29 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Outer parameter 2 12.90 5.40 139.32
Column Offset 2x26 0.25 5.40 70.20
Taking 50% Qtty of above (B) 18.41
30 11.33 Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
11.33.1 12 mm thick
Plaster 1 189.00 189.00
TOTAL: 189.00 meter 4.20 794.00
31 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and WAITINGs etc. complete before plastering upto 10mts in height.
32 Ammendment No-08 14.54 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
14.54.1 Upto 2 mm thickness to make surface even and smooth in line and level.
Qtty as per 6 mm plaster 187.07
Qtty as per 12 mm plaster 540.07
33 Ammendment No-08 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth & even with all tools tackles and labour etc. complete for the work.
Qtty as per 12 mm plaster 470.02
34 Ammendment No-08 14.59 Providing and applying polymeric cement primer on all surface applied @ 0.80litrs/10 sqm as pe relevant IS code 15489:1974 (product such as Birla white prime coat/activcoat, Asian trucare, Dulux interior cement primer, Opus Calista/110) with all tools tackles and labour etc. complete for the work.
Qtty as per sum of above 2 items 1197.16
35 Ammendment No-08 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats applied @1.25 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -1 Class D & C(Glossy & Semi Glossy Finish) of required shed (product such as Tractor emulsion, Dulux Promise, Nerolac Beauty Silver, Berger bison/breeze, Opus 130/Style Paint) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of wall putty 727.14
36 Ammendment No-08 14.67 Providing and applying on exterior surface with ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @1.43 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -2 Class D & C (Glossy & Semi Glossy Finish) (Product such as Asian ACE , Dulux Promise exterior, Berger wall Masta, Nerolac Suraksha Plus, Nippon Shogun Opus, One Style Power Bright) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of external putty 470.02
37 Ammendment No-08 14.72 Providing and applying Glossy Finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10 Sqm upto final finish as per relevant IS Code 2932:2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthetic Enamel, Opus Prime Enamel) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work.
Total 1480103.00
SUB ENGINEER SUB DIVISIONAL OFFICER EXECUTIVE ENGINEER
PWD, SUB DIV.No.-3, DURG PWD, SUB DIV.No.-3, DURG PWD, DURG, DIVISION-DURG
Detailed Estimate for Consrtuction of Additional Room (Administrative Block) in DIET College at Achhoti, Distt-Durg (C.G.) 106730.00
SANITARY AND WATER SUPPLY
S.N. S.O.R. DESCRIPTION NO. L W H. / D. QTY. UNIT RATE AMOUNT
1 18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
18.4.1 White pedestal type 3 3.00 each 2882.00 8646.00
2 18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :
3 18.25 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
w/basin 2 2.00 each 68.50 137.00
4 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 2 2.00 each 599.00 1198.00
5 18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.
18.76.1 75 mm dia pipe.
Toilet 2 6.50 13.00
TOTAL: 27.00 metre 182.00 4914.00
18.76.2 110 mm dia pipe.
Toilet 2 4.50 9.00
up to septic tank 1 35.00 35.00
6 18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90°
18.77.2 Double "Y" with or without door
18.77.3 Vent covel
18.77.4 Access door cap
18.77.6 Nahani trap 110x75mm 4 4.00 each 90.50 362.00
7 18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
8 19.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
19.4.3 25 mm nominal outer dia .Pipes. 1 25.00 25.00 metre 199.00 4975.00
19.4.4 32 mm nominal outer dia .Pipes. 2 8.50 17.00 metre 271.00 4607.00
19.4.5 40 mm nominal outer dia .Pipes. 1 25.00 25.00 metre 362.00 9050.00
9 19.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
CONCEALED WORK including cutting chases and making good the walls etc.,
19.5.1 15 mm nominal outer dia .Pipes. 2 12.50 25.00 metre 133.00 3325.00
19.5.3 25 mm nominal outer dia .Pipes. 2 18.00 36.00 metre 213.00 7668.00
10 19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality:
19.13.3 Stop cock (350 grams) 4 4.00 each 237.00 948.00
11 19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
19.14.2 Long nose bib cock (500 grams) 2 2.00 each 455.00 910.00
19.14.4 Piller Cock (400 grams) 2 2.00 each 398.00 796.00
19.14.16 Towel rail (600mm long x 20mm dia) 2 2.00 each 338.00 676.00
19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) 2 2.00 each 774.00 1548.00
12 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 4 4.00 each 51.00 204.00
13 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
19.16.1 25 mm nominal bore 2 2.00 each 436.00 872.00
19.16.3 40 mm nominal bore 2 2.00 each 596.00 1192.00
14 19.17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
19.17.3 25 mm nominal bore 1 1.00 each 432.00 432.00
15 19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same : 15 15.00 each 125.00 1875.00
16 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 2 2.00 each 4644.00 9288.00
17 19.49 Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 2 2.00 each 8013.00 16026.00
18 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 2 500.00 1000.00 litre 7.30 7300.00
Total Rs: 106730.00
SUB ENGINEER SUB DIVISIONAL OFFICER EXECUTIVE ENGINEER
PWD, SUB DIV.No.-3, DURG PWD, SUB DIV.No.-3, DURG PWD, DURG, DIVISION-DURG
Detailed Estimate for Consrtuction of Additional Room (Administrative Block) in DIET College at Achhoti, Distt-Durg (C.G.) 5446115.00 703294800 -6.18 Lakhs
S.N. SOR Item DESCRIPTION Measurment QTY. UNIT RATE AMOUNT
NO. L W H. / D.
Ground to Plinth Level :
1 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m WAITING and lead upto 50m (at least 5m away from the dressed area).
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m WAITING and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils. 0.08
Plinth Protection 1 89.00 0.30 0.40 10.68 27.2 27.6
3 1.6 Extra for every additional WAITING of 1.5 m or part thereof.
1.6.1 All types of soils
4 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and WAITING upto 1.5 M.
Qtty of excavation Used as Back Filling 504.21 cum 65.00 32773.00
5 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Qtty. of Excavation Qtty as per Item No. (2) 504.21
Filling under Plinth :
Principal Room 1 6.00 5.00 0.80 24.00
Office/Staff Room 1 8.00 5.00 0.80 32.00
Vice Principal Room 1 5.00 5.00 0.80 20.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 0.80 100.00
Toilet /Record Room 6 2.40 1.50 0.80 17.28
Filling under plinth Protection 1 89.00 0.80 0.50 35.60
Deduct - Qtty. of CC M - 10 Qtty as per Item No.6 -29.00
Deduct - Qtty. Of Coln upto PL & Footing Qtty as per Item No.7 -49.26
Back Filling Qtty as per Item No.4 -504.21
6 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Plinth Protection 1 89.00 0.30 0.10 2.67
Plinth Protection Top 1 89.00 1.00 0.10 8.90
Base Below Flooring :
Principal Room 1 6.00 5.00 0.10 3.00
Office/Staff Room 1 8.00 5.00 0.10 4.00
Vice Principal Room 1 5.00 5.00 0.10 2.50
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 0.10 12.50
Toilet /Record Room 6 2.40 1.50 0.10 2.16
7 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column Footing C0/F0 2 1.90 1.90 0.20 1.44
Trapozoidal portion C0 2 (1.90x1.90+0.50+0.50)/2 0.40 1.54 1.930
Column Footing C1/F1 51 1.70 1.95 0.20 33.81
Trapozoidal portion C1 18 (1.70x1.95+0.4x0.65)/2 0.35 11.26 1.788
Column Footing C2/F2 1 1.70 1.80 0.20 0.61
Trapozoidal portion C2 1 (1.70x1.80+0.50x0.60)/2 0.35 0.59 1.680
Column casting up to ground level
Column upto plinth level
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.3 Thermo-Mechanically treated bars FE 550D Taking '@ 100 Kg/cum of RCC 8556.28 Kg 55.00 470595.00
9 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column Footing C0/F0 4 1.90 0.20 1.52
Column Footing C0/F0 4 1.90 0.20 1.52
Column Footing C1/F1 102 1.90 0.20 38.76
Column Footing C1/F1 102 1.95 0.20 39.78
Column Footing C2/F2 36 1.70 0.20 12.24
Column Footing C2/F2 36 1.80 0.20 12.96
Column shuttering up to ground level
Ground beam shuttering 1x2 145.60 0.45 131.04
Plinth beam shuttering 1x2 119.60 0.50 119.60
Column upto plinth level
10 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Up to Plint level brickwork 1 119.60 0.20 0.50 11.96
Plinth Protection 1 89.00 0.20 0.50 1.20
11 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Up to Plint level brickwork 1 119.60 0.20 0.05 1.20
Plinth Protection 1 89.00 0.20 0.05 0.12
12 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
PLINTH LEVEL DPC
Up to Plint level brickwork 1 119.60 0.20 23.92
Plinth Protection 1 89.00 0.20 17.80
Plinth Level to Slab Level :
1 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Stair case: Waist Slab 1 3.60 1.50 0.15 0.81
Landing Slab 1 3.20 1.50 0.15 0.72
Chhajja over Window W1 18 2.10 0.60 0.10 2.27
Ventilator Chhajja V1 8 0.80 0.60 0.10 0.38
Roof Slab with projection 1 504.00 0.125 63.00
Column upto Parapet top C0 2 0.30 0.30 4.625 0.83
Column upto Slab top C1 51 0.20 0.45 3.600 16.52
2 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Qtty same as Previous item TOTAL: 125.25 cum 97.50 12212.00
3 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D Taking '@ 100 Kg/cum of RCC 12524.83 Kg 54.50 682603.00
4 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
COLUMN SHUTTERING PL.TO SLAB LVL.
2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Roof Slab with projection 1 504.00 504.00
2.1.13 Weather shade, chhajja, Cornices and mouldings
Chhajja over Window W1 18 2.10 0.60 22.68
OTS Chhajja 1 39.00 0.60 23.40
Ventilator Chhajja V1 8 0.80 0.60 3.84
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings
Stair case: Waist Slab 1 3.60 1.50 5.40
Landing Slab 1 3.20 1.50 4.80
2.1.8 Beams, lintels, cantilevers & walls
Lintel beam 1x2 236.45 0.20 94.58
5 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work above pilnth 1 236.45 0.20 2.90 137.14
6 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Qtty same as above 118.45 cum 121.00 14332.00
7 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
8 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate prime
9.18.4 Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.
9 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
10 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply eneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.
8.12.1 35mm. thick (single leaf)
11 8.15 Extra for double leaf shutter instead of single leaf.
12 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
13 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
14 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
15 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
TOTAL: 22.00 each 44.00 968.00
16 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.
17 8.152 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter).
8.152.1 PVC door shutter
16 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
9.47.1 For fixed portion
9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
17 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
AS PER ITEM NO.9.47 TOTAL: 50.76 kg 27.00 1371.00
18 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
2 With float glass panes of 5 mm thickness
19 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.2 Size above 200x300mm
Record Room 2 2.40 1.50 7.20 4.50
20 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
12.9.2 Size above 300x300mm
21 12.74 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete.
12.74.3 Size 600x600mm thickness 7 to 8 mm
Principal Room 1 6.00 5.00 30.00
Office/Staff Room 1 8.00 5.00 40.00
Vice Principal Room 1 5.00 5.00 25.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 125.00
Corridor L/S 2 16.80 2.10 70.56
Corridor R/S 2 11.90 2.10 49.98
Enterance 1 4.00 5.00 20.00
Stair Room 1 3.20 5.20 16.64
Vice Principal Room 1 4x5.00 0.10 2.00 5.00 5.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 4x5.00 0.10 10.00 5.00 5.00
22 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
12.46.2 Granite stone black
Landing Slab 1 3.20 1.50 4.80
23 12.44 Extra for nosing in Granite stone for treads.
in Edges 24 1.50 36.00
24 12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.
12.3.1 40 mm thick
Plinth Protection 1 89.00 1.00 89.00
25 10.53 Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately)
10.53.1 Flat surface
Principal Room 1 6.00 5.00 30.00
Office/Staff Room 1 8.00 5.00 40.00
Vice Principal Room 1 5.00 5.00 25.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 125.00
10.53.2 Curved surface Qtty same as above 112.52 sqm 895.00 10070500 100705.4
26 10.58 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above.
Principal Room 1 6.00 5.00 30.00
Office/Staff Room 1 8.00 5.00 40.00
Vice Principal Room 1 5.00 5.00 25.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 125.00
27 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand)
Principal Room 1 6.00 5.00 30.00
Office/Staff Room 1 8.00 5.00 40.00
Vice Principal Room 1 5.00 5.00 25.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 5.00 5.00 125.00
Corridor L/S 2 16.80 2.10 70.56
Corridor R/S 2 11.90 2.10 49.98
Enterance 1 4.00 5.00 20.00
Beam Offsets 9x2 5.00 0.35 31.50
Stair case : Waist Slab 1 3.60 1.50 5.40
Landing Slab 1 3.20 1.50 4.80
28 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Vice Principal Room 1 4x5.00 3.48 69.60 5.00 5.00
DFI & SI Cell, PSTE Cell, SE Cell, ISTE Cell &ISTE Cell 5 4x5.00 3.48 348.00 5.00 5.00
Beam Offsets 6x2 4.75 0.35 19.95 5.00
Column Offset 6x2 0.25 3.60 10.80 3.60 1.50
Taking 50% Qtty of above (B) 44.58
29 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Outer parameter 2 27.20 5.40 293.76
Column Offset 2x26 0.25 5.40 70.20
Taking 50% Qtty of above (B) 44.58
30 11.33 Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
11.33.1 12 mm thick
Plaster 1 189.00 189.00
TOTAL: 189.00 meter 4.20 794.00
31 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and WAITINGs etc. complete before plastering upto 10mts in height.
32 Ammendment No-08 14.54 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
14.54.1 Upto 2 mm thickness to make surface even and smooth in line and level.
Qtty as per 6 mm plaster 435.78
Qtty as per 12 mm plaster 1269.06
33 Ammendment No-08 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth & even with all tools tackles and labour etc. complete for the work.
Qtty as per 12 mm plaster 690.44
34 Ammendment No-08 14.59 Providing and applying polymeric cement primer on all surface applied @ 0.80litrs/10 sqm as pe relevant IS code 15489:1974 (product such as Birla white prime coat/activcoat, Asian trucare, Dulux interior cement primer, Opus Calista/110) with all tools tackles and labour etc. complete for the work.
Qtty as per sum of above 2 items 2395.28
35 Ammendment No-08 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats applied @1.25 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -1 Class D & C(Glossy & Semi Glossy Finish) of required shed (product such as Tractor emulsion, Dulux Promise, Nerolac Beauty Silver, Berger bison/breeze, Opus 130/Style Paint) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of wall putty 1704.84
36 Ammendment No-08 14.67 Providing and applying on exterior surface with ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @1.43 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -2 Class D & C (Glossy & Semi Glossy Finish) (Product such as Asian ACE , Dulux Promise exterior, Berger wall Masta, Nerolac Suraksha Plus, Nippon Shogun Opus, One Style Power Bright) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of external putty 690.44
37 Ammendment No-08 14.72 Providing and applying Glossy Finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10 Sqm upto final finish as per relevant IS Code 2932:2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthetic Enamel, Opus Prime Enamel) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work.
38 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
9.57.2 SS Grade 304
Stair Railing 1 7.95 0.90 7.16
Taking 6.5 Kg/Sqm 46.51 Kg 525.00 24416.00
Total 5446115.00
SUB ENGINEER SUB DIVISIONAL OFFICER EXECUTIVE ENGINEER
PWD, SUB DIV.No.-3, DURG PWD, SUB DIV.No.-3, DURG PWD, DURG, DIVISION-DURG
Detailed Estimate For Construction of Staff Toilet in Main Administrative Building at ITI Campus Power House, Bhilai, Distt.-Durg (C.G.) 76564.00
S.No. S.O.R. Item No L B H / D Qtty Unit Rate Amount
1 1.1 P-9 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
2 1.6 P- 10 Extra for every additional lift of 1.5 m or part thereof.
3 1.18 P-9 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Side filling 1 14.60 0.45 1.60 10.51
4 1.17 P-11 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. Qtty same as item (1) 29.84 M3 65.00 1940.00
5 3.1 P-22 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 1 4.90 2.90 0.15 2.13 M3 2970.00 6331.00
6 7.2 P-44 Brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in foundation and plinth in: 1.3
7.2.1 Cement Mortar 1:5 (1 Cement : 5 Coarse Sand)
Buffel Wall 1 2.00 0.20 1.80 0.72
7 3.2 P-23 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size)
8 3.12 P-24 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.1 Thermo-Mechanically treated bars FE 415 1.58 Cum @ 100 Kg / Cum 158.40 Kg 54.50 8633.00
9 3.4 P-23 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 2
Slab Bottom 1 4.00 2.00 8.00
10 11.2 P-103 Providing and making 12mm thick cement plaster of mix:
11.2.1 In cement Mortar 1:3 (1 cement : 3 fine sand)
I/Side plaster 1 2(4.00+2.00) 2.10 25.20
Buffel Wall 1x2 2.00 1.80 7.20
11 11.5 P-104 Neat Cement punning. Qtty same as above 32.40 M2 33.00 1069.00 0.0972
12 11.9 P-104 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. Qtty same as above x 0.012 x0.25 = 0.081Cum x 28.80=2.80 2.80 Kg 43.50 122.00 2.79936 2.3328
13 12.3 P-111 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.
Sub - Engineer Sub-Divisional Officer Executive Engineer
Sub Dn.-3,Durg P.W.D. Sub Dn.3 Durg P.W.D. Division, Durg
Detailed Estimate for Consrtuction of Additional Room (Acadamic Block) in DIET College at Achhoti, Distt--Durg (C.G.) 6775461.00 765146000
S.N. SOR Item DESCRIPTION Measurment QTY. UNIT RATE AMOUNT
NO. L W H. / D.
Ground to Plinth Level :
1 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m WAITING and lead upto 50m (at least 5m away from the dressed area).
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m WAITING and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
Plinth Protection 1 118.00 0.30 0.40 14.16
3 1.6 Extra for every additional WAITING of 1.5 m or part thereof.
1.6.1 All types of soils
4 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and WAITING upto 1.5 M.
Qtty of excavation Levelling of ground 479.21 cum 65.00 31149.00
5 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Qtty. of Excavation Qtty as per Item No. (2) 479.21
Filling under Plinth :
Filling under plinth Protection 1 118.00 0.80 0.50 47.20
Deduct - Qtty. of CC M - 10 Qtty as per Item No.6 -26.30
Deduct - Qtty. Of Coln upto PL & Footing Qtty as per Item No.7 -95.97
6 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Plinth Protection 1 118.00 0.30 0.10 3.54
Plinth Protection Top 1 118.00 1.20 0.10 14.16
Base Below Flooring :
7 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column Footing C1/F1 46 1.90 1.70 0.20 29.72
Column Footing C2/F2 22 1.70 1.70 0.15 9.54
Trapozoidal portion C1 22 (1.702+0.502)/2 0.35 12.09 1.570
Column casting up to ground level
Column upto plinth level
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.3 Thermo-Mechanically treated bars FE 550D Taking '@ 100 Kg/cum of RCC 12731.80 Kg 55.00 700249.00
9 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column Footing C1/F2 92 1.90 0.20 34.96
Column Footing C1/F2 92 1.70 0.20 31.28
Column Footing C2/F2 44 1.70 0.15 11.22
Column Footing C2/F2 44 1.70 0.15 11.22
Column shuttering up to ground level
Ground beam shuttering 1x2 141.40 0.45 127.26
Plinth beam shuttering 1x2 112.55 0.50 112.55
Column upto plinth level
10 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Up to Plint level brickwork 1 112.55 0.20 0.40 9.00
Plinth Protection 1 118.00 0.20 0.50 1.20
11 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Up to Plint level brickwork 1 112.55 0.20 0.05 1.13
Plinth Protection 1 118.00 0.20 0.05 0.12
12 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
PLINTH LEVEL DPC
Up to Plint level brickwork 1 112.55 0.20 22.51
Plinth Protection 1 118.00 0.20 23.60
Plinth Level to Slab Level :
1 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Stair case: Waist Slab 1 3.60 1.50 0.15 0.81
Landing Slab 1 3.20 1.50 0.15 0.72
Chhajja over Window W1 21 2.10 0.60 0.10 2.65
Front Chhajja 1 39.35 0.60 0.10 2.36
Ventilator Chhajja V1 8 0.80 0.60 0.10 0.38
Roof Slab with projection 1 575.00 0.125 71.88
Column upto Parapet top C1 46 0.30 0.45 4.625 28.72
Column upto Parapet top C1 40 0.30 0.45 0.90 4.86
Column upto Tower Room 4 0.30 0.45 3.000 1.62
2 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Qtty same as Previous item TOTAL: 161.06 cum 97.50 15703.00
3 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D Taking '@ 110 Kg/cum of RCC 17716.71 Kg 54.50 965561.00
4 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
COLUMN SHUTTERING PL.TO SLAB LVL.
2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Roof Slab with projection 1 575.00 575.00
2.1.13 Weather shade, chhajja, Cornices and mouldings
Chhajja over Window W1 21 2.10 0.60 26.46
Front Chhajja 1 39.35 0.60 23.61
Ventilator Chhajja V1 8 0.80 0.60 3.84
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings
Stair case: Waist Slab 1 3.60 1.50 5.40
Landing Slab 1 3.20 1.50 4.80
2.1.8 Beams, lintels, cantilevers & walls
Lintel beam 1x2 225.20 0.20 90.08
5 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work above pilnth 1 225.20 0.20 2.90 130.62
6 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Qtty same as above 87.03 cum 121.00 10531.00
7 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
8 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate prime
9.18.4 Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.
9 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
10 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply eneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.
8.12.1 35mm. thick (single leaf)
11 8.15 Extra for double leaf shutter instead of single leaf.
12 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
13 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
14 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
15 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
16 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
9.47.1 For fixed portion
9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
17 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
AS PER ITEM NO.9.47 TOTAL: 72.36 kg 27.00 1954.00
18 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
2 With float glass panes of 5 mm thickness
19 10.1 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm)
10.1.1 1.00 mm thick sheet (weight 8.60 kg/m2)
20 12.74 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete.
12.74.3 Size 600x600mm thickness 7 to 8 mm
Class Room 5 8.00 6.00 240.00
Corridor L/S 1 37.80 2.20 83.16
Corridor X/S 1 20.60 2.20 45.32
Stair Room 1 3.20 6.00 19.20
Entrance 1 4.50 6.00 27.00
21 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
12.46.2 Granite stone black
Landing Slab 1 3.20 1.50 4.80
22 12.44 Extra for nosing in Granite stone for treads.
in Edges 24 1.50 36.00
23 12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.
12.3.1 40 mm thick
Plinth Protection 1 118.00 1.00 118.00
24 10.53 Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately)
10.53.1 Flat surface
Class Room 5 8.00 6.00 240.00
10.53.2 Curved surface Qtty same as above 145.20 sqm 895.00 12995400 129954
25 60. 10.58 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above.
Class Room 5 8.00 6.00 240.00
26 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand)
Class Room 5 8.00 6.00 240.00
Corridor L/S 1 37.80 2.20 83.16
Corridor X/S 1 20.60 2.20 45.32
Stair Room 1 3.20 6.00 19.20
Entrance 1 4.50 6.00 27.00
Beam Offsets 8x2 6.00 0.35 33.60
Stair case : Waist Slab 1 3.60 1.50 5.40
Landing Slab 1 3.20 1.50 4.80
27 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Column Offset 2x26 0.25 3.60 46.80
Taking 50% Qtty of above (B) 114.81
28 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.3 In Cement Mortar 1:5 (1 cement : 5 fine sand)
Internal wall plaster
Outer parameter 2 47.50 5.40 513.00
Column Offset 2x26 0.25 5.40 70.20
Taking 50% Qtty of above (B) 114.81
29 11.33 Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
11.33.1 12 mm thick
plaster 1 212.00 212.00
TOTAL: 212.00 meter 4.20 890.00
30 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and WAITINGs etc. complete before plastering upto 10mts in height.
31 Ammendment No-08 14.54 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
14.54.1 Upto 2 mm thickness to make surface even and smooth in line and level.
Qtty as per 6 mm plaster 539.63
Qtty as per 12 mm plaster 1225.11
32 Ammendment No-08 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth & even with all tools tackles and labour etc. complete for the work.
Qtty as per 12 mm plaster 922.61
33 Ammendment No-08 14.59 Providing and applying polymeric cement primer on all surface applied @ 0.80litrs/10 sqm as pe relevant IS code 15489:1974 (product such as Birla white prime coat/activcoat, Asian trucare, Dulux interior cement primer, Opus Calista/110) with all tools tackles and labour etc. complete for the work.
Qtty as per sum of above 2 items 2687.35
34 Ammendment No-08 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats applied @1.25 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -1 Class D & C(Glossy & Semi Glossy Finish) of required shed (product such as Tractor emulsion, Dulux Promise, Nerolac Beauty Silver, Berger bison/breeze, Opus 130/Style Paint) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of wall putty 1764.74
35 Ammendment No-08 14.67 Providing and applying on exterior surface with ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @1.43 lit/10 Sqm upto final finish as per relevant IS Code 15489:2013 Type -2 Class D & C (Glossy & Semi Glossy Finish) (Product such as Asian ACE , Dulux Promise exterior, Berger wall Masta, Nerolac Suraksha Plus, Nippon Shogun Opus, One Style Power Bright) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. ( With 2 yearwarranty)
Quantity of external putty 922.61
36 Ammendment No-08 14.72 Providing and applying Glossy Finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10 Sqm upto final finish as per relevant IS Code 2932:2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthetic Enamel, Opus Prime Enamel) inclusive of providing abro tape on edge and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work.
37 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
9.57.2 SS Grade 304
Stair Railing 1 7.95 0.90 7.16
Taking 6.5 Kg/Sqm 46.51 Kg 525.00 24416.00
Total 6775461.00
SUB ENGINEER SUB DIVISIONAL OFFICER EXECUTIVE ENGINEER
PWD, SUB DIV.No.-3, DURG PWD, SUB DIV.No.-3, DURG PWD, DURG, DIVISION-DURG
Detailed Estimate for Consrtuction of Additional Room (Administrative Block) in DIET College at Achhoti, Distt-Durg (C.G.)
GENERAL ABSTRACT
S.No. Sub Head Amount
1 Ground Floor 544611500 5446115
2 First Floor 148010300 1480103
3 Water supply & Sanitary fittings 10673000 106730
B Electrification Works @ 10% of Civil Work 000 0
SAY Rs. 70.33 Lakhs 70.32948 -6.18 Lakhs
Detailed Estimate for Consrtuction of Additional Room (Administrative Block) in DIET College at Achhoti, Distt-Durg (C.G.) 76564.00
S.No. S.O.R. Item No L B H / D Qtty Unit Rate Amount
1 1.1 P-9 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
2 1.6 P- 10 Extra for every additional lift of 1.5 m or part thereof.
3 1.18 P-9 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Side filling 1 14.60 0.45 1.60 10.51
4 1.17 P-11 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. Qtty same as item (1) 29.84 M3 65.00 1940.00
5 3.1 P-22 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 1 4.90 2.90 0.15 2.13 M3 2970.00 6331.00
6 7.2 P-44 Brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in foundation and plinth in: 1.3
7.2.1 Cement Mortar 1:5 (1 Cement : 5 Coarse Sand)
Buffel Wall 1 2.00 0.20 1.80 0.72
7 3.2 P-23 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size)
8 3.12 P-24 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.1 Thermo-Mechanically treated bars FE 415 1.58 Cum @ 100 Kg / Cum 158.40 Kg 54.50 8633.00
9 3.4 P-23 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 2
Slab Bottom 1 4.00 2.00 8.00
10 11.2 P-103 Providing and making 12mm thick cement plaster of mix:
11.2.1 In cement Mortar 1:3 (1 cement : 3 fine sand)
I/Side plaster 1 2(4.00+2.00) 2.10 25.20
Buffel Wall 1x2 2.00 1.80 7.20
11 11.5 P-104 Neat Cement punning. Qtty same as above 32.40 M2 33.00 1069.00 0.0972
12 11.9 P-104 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. Qtty same as above x 0.012 x0.25 = 0.081Cum x 28.80=2.80 2.80 Kg 43.50 122.00 2.79936 2.3328
13 12.3 P-111 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.
Sub - Engineer Sub-Divisional Officer Executive Engineer
Sub Dn.-3,Durg P.W.D. Sub Dn.3 Durg P.W.D. Division, Durg
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
8235061755327496645_201898_Affidavit.docx
NIT • 0.01 MB
5250634917130230385_201898_BID-CAPACITY-2.docx
NIT • 0.03 MB
4231973230134108988_201898_English Notice more than 1 Crore.docx
NIT • 0.03 MB
597993845007837207_201898_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7048173411536933958_201898_Latest A_ 2.doc
NIT • 0.16 MB
4762215986137243811_201898_Latest NIT APPENDIX 2.doc
NIT • 0.32 MB
8314290355740542225_201898_NIT Schedule of Achhoti M.xlsx
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .