| 1 | | Supplying of 1.5 TR inverter type 5 Star rated split AC unit as per BEE star rating, minimum ISEER of 5.2 with temperature control thermistor remote control unit filters, rotary scroll type compressor, copper tubes for both indoor and outdoor unit, topping up of refrigerant if required, transportation of all of the above to the various sites and supplying the following up to the length of 3 mtrsetc as required.
1. hot and cold refrigerant piping each and
2. suitable connecting electrical cable between indoor and out door unit. 1. The unit shall have atleast 12 months manufacturers / Suppliers warranty from date of installation. Warranty on PCB shall be minimum 5 years and compressor shall be minimum 10 yearsas. 2.The Rotary compressor shall be of Matsushita/Hitachi/Toshiba/Carrier/ Emerson /LG/ Tecumseh/Danfoss make and shall be covered by manufacturers test certificate and Type Test Certificate according to JIS or ASHRAE .Note 1. The length of refrigerant piping for liquid refrigerant , hot gas refrigerant and lenght of copper conductor cable for connection from indoor to outdoor unit shall be included upto 3 mtrs. Extra length of refrigerant piping and power cable shall be paid as per item no.2 and 3. The drain pipe of good quality as recommended by the manufacturer upto3 mtrs is also included in this item. | 20 | Nos | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 2 | | Supply of 3 TR Metal Body Ductable Air conditioning unit operating on 400 V, 3Phase 50 Hz AC supply, suitable for R 410A/32 or similar environment frendly refrigerant gas with Rotary/Scroll Compressor, corded remote, Air cooled condenser etc including transportation, fixing the Outdoor unit on the existing Platform / stand with necessary vibration arrestors, fixing the indoor unit on the ceiling /wall, providing interconnection between indoor and outdoor units, electrical connection from power outlet near condenser unit to condenser etc, first charging of Refrigerant gas, making opening in the wall if required and making good the damages, leak testing etc complete as per specifications and terms and conditions attached
Make Panasonic / Voltas /Hitachi / LG /
Carrier / Daikin / Mitsubishi / Samsung / O General /
Blue star / Voltas | 20 | Nos | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 3 | | Installation, Testing and Commissioning of 1.5 TR inverter type split AC unit having nominal cooling capacity of 4500 Kcal / hr 5.2 KW, minimum room air flow of 700 cub.mtr/hr and minimum Indian Seasonal Energy Efficient Ratio ISEER of 5 along with the copper pipe, suitable size of PVC insulated cord wire and PVC drain pipe up to the length of 3 mtrs. including transportation, gas charging, insulation, and making opening in wall and making good the damages etc., complete as per specifications, terms and conditions attached as required. For item no. 1 above. | 20 | Nos | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 4 | | Providing and fixing the following additional items suitable for the above AC units, over and above 3 mtrs length where ever required. a. Copper pipes hot gas and liquid line including insulation etc., as required. | 60 | Mtr | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 5 | | b. 3x2.5 sqmm size of PVC insulated copper condr. Flexbile cable. | 100 | Mtr | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 6 | | c. 20mm NS size of PVC drain pipe. | 100 | Mtr | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 7 | | d. Heavy Duty Powder coated M.S. Stand for outdoor unit. | 20 | Nos | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 8 | | Installation, Testing and Commisioning of ductable Air conditioning complete with supporting , fitting of ducting , stand, lead, damper/grill, canvas with suitable insulation and conduit complete in all respect. For item no. 2 above. | 20 | Job | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 9 | | Supplying and laying of refrigerant piping both liquid and suction lines in the existing tray for the above 3 TRn ductable split AC unit along with necessary accessories like nitrile rubber insulation, clamping etc as required. | 80 | mtr | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |
| 10 | | Fabrication and fixing of MS frame made of required size MS angle, MS flats etc for supports for Indoor units, out door unit ladder type trays etc I/c cutting, drilling holes, welding grouting, painting, fixing on wall, roof etc as required . As directed by Engineer in charge | 40 | Job | Sudhanshu Saxena 226001,O/o CE(Electrical)First Floor, Bhopal House, Lalbagh Lucknow-226001 | 60 |