Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 2RA 135 PRESS COLONY KHARVEL NAGAR UNIT III BHUBANESWAR 751001 | BHUBANESWAR | KHORDHA | ODISHA | 751001 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance HOUSE NO HIG 4 3 HOUSING BOARD COLONY CHANDRA SEKHAR PUR BHUBANESWAR KHURDA ODISHA 751016 | KHORDHA | ODISHA | 751016 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.9 L
EMD Value
₹3,769
Closing Date
4 Apr 2026, 5:00 pmClosed
DIRECTOR NISER
NISER Bhubaneswar, Jatni
Provision for installation of AC power points and AC three phase static energy meter for the Cafeteria Dining Hall in the Auditorium
2026_NISER_903858_1
NISER/IWD-ELECT/AUD/26-27/01
Open Tender
Electrical Works
Works
30 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3,769
Yes
6 Apr 2026
27 Mar 2026
6 Apr 2026
27 Mar 2026
4 Apr 2026
28 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (8 + 12), Double door
Make-Legrand/Hager/Schnieder/Havells | 1 | Each | - | - |
| 0.0 | Supplying and fixing following rating, four pole, 63Amp, 415 V, isolator MCB in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Make-Legrand/Hager/Schnieder/Havells | 1 | Each | - | - |
| 3 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp RCCB
Make-Legrand/Hager/Schnieder/Havells | 1 | Each | - | - |
| 0.0 | Supplying and fixing 25 A rating, 240/415 V, 10 kA, "C" curve, SP MCB (miniature circuit breaker) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required in the existing DB. Make-Legrand/Hager/Schnieder/Havells | 6 | Each | - | - |
| 5 | SITC of AC three phase static energy meter Projection Mounted:-
AC Three Phase Trivector Meter DLMS Compliance of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display of rating 20-100A. (Measures & Trivector energy, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical & RS232 Communication Port & Display in absence of Power. | 1 | Each | - | - |
| 0.0 | Supplying and fixing 25 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 25 A "C" curve, DP, RCCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make-Legrand/Hager/Schnieder/Havells | 6 | Each | - | - |
| 7 | Supply and Cable laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.3.5Cx25 Sq MM AL Armoured XLPE Cable with 10SWG GI wire. Make: Polycab/Finolex/RR Kabel | 200 | Mtr | - | - |
| 0.0 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5Cx25 SQmm Cable (28mm) | 2 | Each | - | - |
| 9Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR | |||||
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
Tendernotice_2.pdf
PDF • 0.42 MB
BOQ_950041.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .