| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹91,318.20 (6.74%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹14.5 L+₹91,408.20 (6.75%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | Rejected-Technical H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | - | Rejected-Technical Not Enlishted required catergory |
Tender Value
Refer Docs
EMD Value
₹32,700
Closing Date
23 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Dinesh Sharma
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINTENANCE OF SUMMER APPLIANCES, RO PLANTS, SOLAR WATER HEATER, HEATING SYSTEM, HT AND LT OH LINES, UNDER GROUND CABLES, POLES, STREET/ SECURITY LIGHTS AND OTHER CONNECTED WORKS AT DHARMUND UNDER GE (I) 873 EWS
2020_MES_372056_1
NIT-41 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
BHADERWAH
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) 873 EWS
₹32,700
Yes
3 Nov 2020
26 Aug 2020
28 Sept 2020
26 Aug 2020
23 Sept 2020
9 Sept 2020
60 days
Amount
Taking down carefully AC ceiling fan 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearing, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin/screw for fan down rod/check nuts as required for different makes of ceiling/exhaust fans to put fans to smooth and satisfactory working and refixing ceiling fan/exhaust fan after executing necessary servicing to their position connecting to electric system with suitable size of cable and testing, complete all as specified & directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
Preparation of old painted steel surfaces of ceiling fan, exhaust fan and wall mounting fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying two coats of synthetic enamelled first quality paint using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed.
Rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed. Make:- Atlas/ Finolex/ GEC
Rewinding of exhaust fan, 230 volts, 50 Hz, 450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed. Make:- Atlas/ Finolex/ GEC
Ball bearing 6202/6203, fixed in repair suitable for AC ceiling fan of 1200mm sweep/ exhaust fan/ air circulation fan of any make to replace the unserviceable bearing including greasing as required, complete all as specified & directed. Make:- SKF/ NBC/ Tata
Capacitor fixed in repair, 4 Mfd 230 volts, AC, 50 Hz, complete all as specified & directed. Make:- Crompton Greaves/ Bajaj/ Orient/ GEC/ Khaitan
Capacitor fixed in repair, 2.5 Mfd 230 volts, AC, 50 Hz, complete all as specified & directed. Make:- Crompton Greaves/ Bajaj/ Orient/ GEC/ Khaitan
Fan canopy fixed in repair, complete all as specified & directed. Make:- Crompton Greaves/ Bajaj/ Orient/ GEC/ Khaitan
Preparation of old painted steel surfaces by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and repainting by applying two coats of synthetic enamelled first quality paint using spray gun over one coat of red oxide zinc chrome primer and marking Srl No SM No / MES No with black paint of following items :-
Refrigerator of capacity 300/310 Litres.
Deep Freezer of capacity 320 Litres.
The following unserviceable items of refrigerator of 300/310/320 litres, fixed in repair as required at site including testing of the same, complete all as specified & directed :-
MS condensing coil with fixing arrangement for 300 litres capacity complete with gas charging.
Deep Freezer door for 320 litres refrigerator. Make:- Voltas/ Whirlpool/ LG/ Samsung
Over load protector. Make:- Voltas/ Whirlpool/ LG/ Samsung
Thermostat switch (Auto defrost). Make:- Voltas/ Whirlpool/ LG/ Samsung
Temp control knob with defrost push button. Make:- Voltas/ Whirlpool/ LG/ Samsung
Electrical lamp pin/threaded type 15 watt, 240 volts AC supply. Make:- Voltas/ Whirlpool/ LG/ Samsung
PVC vegetable tray with glass cover supper quality. Make:- Voltas/ Whirlpool/ LG/ Samsung
PVC ice tray of superior quality. Make:- Voltas/ Whirlpool/ LG/ Samsung
Adjustable shelves. Make:- Voltas/ Whirlpool/ LG/ Samsung
Chiller tray. Make:- Voltas/ Whirlpool/ LG/ Samsung
Bottle supporter. Make:- Voltas/ Whirlpool/ LG/ Samsung
Magnetic door gasket. Make:- Voltas/ Whirlpool/ LG/ Samsung
Door handle. Make:- Voltas/ Whirlpool/ LG/ Samsung
Relay as per existing. Make:- Voltas/ Whirlpool/ LG/ Samsung
PVC drain tray. Make:- Voltas/ Whirlpool/ LG/ Samsung
Taking down defective Split AC of 1.5 Ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/worn-out parts & making serviceable, complete all as specified & directed by Engr-in-charge. Note:- Worn out spares parts required for making AC serviceable/functional shall be measured and paid separately under respective item of schedule 'A'.
Supply only Fan motor for 1.5 ton AC. Make:- Voltas/ Hitachi/ Daikin/ Carrier/ Fedders Lelyod/ Whirlpool
Supply only AC compressor for 1.5 ton AC. Make:- Voltas/ Hitachi/ Daikin/ Carrier/ Fedders Lelyod/ Whirlpool
Supply only gas 22 R for 1.5 ton AC.
Supply only AC copper pipe of size 8mm and 15 mm for 1.5 ton AC.
Supply only 45 Mfd capacitor for 1.5 ton AC. Make:- L&T/ ABB/ Siemens/ Schneider/ GE.
Supply only contactor, single phase, 30 Amp for 1.5 ton A Make:- L&T/ ABB/ Siemens/ Schneider/ GE.
Supply only fan belt for 1.5 Ton AC.
Supply only cabinet body/compressor body for 1.5 ton AC. Make:- Voltas/ Hitachi/ Daikin/ Carrier/ Fedders Llyod/ Whirlpool
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 4.0 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 6.0 Sqmm wire, one run of 4.0 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart with 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable cable complete complete all as specified and directed.
MCB SPN 40 Amp 10 KA 415 Volts, 'C' Series, complete all as specified and as directed.
Dismantling and refixing the complete unit of Solar Water Heater installed at various sites complete overhauling, cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nuts, bolts, washers and all other minor accessories as required at site including painting to solar water heater by rubbing the old paint and applying with two coats of synthetic enamelled paint by spray painting and testing the same after repair, complete all as specified and directed of the following description. Note : Replacement of spares shall be measured and paid for separately.
(a) Capacity 500 LPD
(b) Capacity 300 LPD
Supply only the follwing items / spares required for Solar Water Heaters of various capacities complete all as specified and directed :- Make : Surya Shakti / TATA Solar / Racold Solar
Heating Element (Electric rod) of capacity up to and including 2 KW having rubber washer of size 1½" or 1¼".
Heating Element (Electric rod) of capacity up to and including 1.5 KW having rubber washer of size 1½" or 1¼".
Glycol (Anti freezing solution) for filling in copper tubes.
Float valve assembly 25mm bore.
Thermostat suitable for solar water heater.
Dead flange with nut, bolts and washers.
Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
MCB SP 6 to 32 Amp 10 KA 'C' Series, complete all as specified and as directed.
MCB SPN 6 to 32 Amp 10 KA 'C' Series, complete all as specified and as directed.
On-site Repair / Maintenance and Servicing of RO plants by dismantling, checking all parts i.e. Pre-filter, granular activated carbon block filter, membrane, UV disinfection / filtration system, adaptor, pressure pump set, main pump motor, solenoid valve, flow controller, all gauges, filling of anti-scalent liquid, checking functioning of all type meters, electric wiring, contactors & relay, switches, valves and replacement of old unserviceable parts, checking of leakages of any part of plants and pipe line by new parts and pipe line including re-assembling the same as original and reinstalling at same place including re-connecting with the existing water supply system and testing at full capacity discharge of filtered water complete all as specified and as directed of the following description :-
(a) RO Plant of 50 Ltrs/Hours capacity
(b) RO Plant of 100 Ltrs/Hours capacity
(c) RO Plant of 150 Ltrs/Hours capacity
Notes for Serial Item No 24 :- 1. Spare parts required for replacement of the defective parts to make the RO Plant fully functional shall be measured and paid separately under appropriate item of this Schedule as 'Supply only'. 2. The Contractor will ensure that all RO plants are functional throughout the contract period by detailing his technical team once in each quarter though out the contract period for servicing and maintenance. 3. In the eventually of any RO plants not working after the last service and before the next service, the contractor will attend the complaint within 72 hours of intimation of the complaint through SMS / e-mail / WhatsApp message from JE (E/M) / AGE (E/M). The Visit charge due to any such complaint shall be deemed to be included in the quoted rates against Serial item No 01 and nothing extra shall be admissible on this account.
Supply only Bib tap cast copper alloy with crutch of butterfly handle, screwed down, screwed for 15mm bore iron pipe or for brass ferrule, complete all as specified and directed.
Supply only Stop valve cast copper alloy with crutch of butterfly handle, screwed down, screwed for 15mm bore iron pipe or for brass ferrule, complete all as specified and directed.
Supply only PVC tubing of 14mm bore, complete all as specified and directed. Make : Renuka/ Kent / Eureka Forbes
Supply only PVC tubing of 12mm bore, complete all as specified and directed. Make : Renuka/ Kent / Eureka Forbes
Repair / Maintenance of Feeding Pump of 0.37 KW / 0.5 HP installed in RO plant at various locations by disconnecting of RO plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
Repair / Maintenance of Pressure Pump of 1 to 2 HP installed in RO plant at various location by disconnecting of RO plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
Supply only Feeding Pump suitable for small water filtration plant of rating 0.37 KW/ 0.5 HP, 230 volts, 50 Hz, Single Phase, 20 meter head and discharge rate 40 LPM, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pressure Pump suitable for small water filtration plant of rating 0.75/1.0 KW/HP, 230 volts, 50 Hz, 3 stage & discharge rate 750 LPH, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pressure Pump suitable for small water filtration plant of rating 1/1.50 KW/HP, 230 volts, 50 Hz, 5 stage and discharge rate 750 LPH, maximum head 47 meter, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pre-Filter (Micronic Filter) candle of following size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
(a) Size 10 inch
(b) Size 20 inch
Supply only Carbon block Filter of following size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
(a) Size 10 inch
(b) Size 20 inch
Supply only Membranes of following capacity, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only ultra violet rays (UV) bulb for 75 LPH / 100 LPH / 150 LPH / 250 LPH / 500 LPH RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only Media Cylinder of following capacity, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only flow restrictor adjuster of following capacity, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes / Hi Tech
(a) 75 to 150 LPH
(b) 250 to 500 LPH
Supply only Dozing system (AD system for anti-scalent) for RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only Micronic Shell (Filter housing) of following size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
(a) 20 inches
(b) 10 inches
Supply only Anti-scalant Liquid (membrane protector), complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC elbow of 1/2 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC elbow of 3/4 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC union of 1/2 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC union of 3/4 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC pipe of 1/2 inch bore, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC pipe of 3/4 inch bore, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only capacitor of 10 MFD, complete all as specified and directed. Make : L&T / ABB / Siemens / GE
Supply only capacitor of 30 MFD, complete all as specified and directed. Make : L&T / ABB / Siemens / GE
Supply only Solenoid Valve, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC pipe Adhesive, complete all as specified and directed.
Supply only Taflon Tape for RO, complete all as specified and directed.
Maintenance and repair of Control Unit of Filteration Plant of Capacity 2500 LPH, complete all as specified and directed.
Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 16 Sqmm 3 Core, complete all as specified and directed. Make : Havells / Finolex / Polycab / Plaza / Asian
Material and labour for disconnecting electrical connection removing the defective transformer, loading and transporting to workshop from site and vice-versa including disconnecting and rewinding of 11/0.433KV, 63 KVA to 250KVA, Three Phase, Four Wire, 50Hz vector group Dyn 11 transformer with paper insulated copper winding wire / strip as per original data on HV (delta connection) and LV (Star Connection) 7 tapping brought on HV side for tap charger to change + 2.5%, 5%, 7.5% by means of manually operated Off-Load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc. and re-conditioning three limbs complete opening, replacement of cock sheet packing, vent diaphragm replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 50 KV dielectric strength and testing of transformer at factory and site after connecting all electrical connection in full load all as directed.
Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning.
Supply only following Items / Spares required for transformers :-
(a) Gasket for Transformer
(b) LT Terminal Plate for outgoing connections
(c) Breather for Transformer of capacity 63 KVA to 315 KVA
(d) HT coil of suitable gauge of paper insulated copper winding wire for any capacity of transformer
(e) LT coils of suitable guage of paper insulated copper winding wire for any capacity of transformer
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 95 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed.
Supply, filling and top up with new Transformer Oil of dielectric strength more than 50 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 45 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified & directed.
Switch Air break, gang operated (GOD) with 15 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 400 Amps including taking down old unserviceable GOD complete all as specified and directed..
Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade complete including taking down old unserviceable insulator complete all as specified and directed.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Painting of steel tubular pole any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Pin type insulator porcelain vitereous white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complet including taking down old unserviceable Pin type complete all as specified and directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm) or Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm galvanised iron strip including taking down old unserviceable earthing strip complete all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0mm dia galvanised iron or steel wire including taking down old unserviceable earthing strip complete all as specified and directed
Lightning arrester expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed directed to sun with ambient temperature between (-)10º C to (+)50º C suitable for surge discharge capacity 65 KA, 11000 volts grade conforming to IS-4350 including all fittings, complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Poles all as specified and as directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Poles all as specified and as directed.
MCCB 63 Amps, breaking capacity 25 KA, FP, 415V incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
MCCB 100 Amps, breaking capacity 25 KA, FP, 415V incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
MCCB 160 Amps, breaking capacity 25 KA, FP, 415V, G frame (fixed thermal and fixed magnetic setting) fixed in existing panel and connected to old existing cable incl necessary fixing arrangement incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
MCCB 200 Amps, breaking capacity 25 KA, FP, 415V, G frame (fixed thermal and fixed magnetic setting) fixed in existing panel and connected to old existing cable incl necessary fixing arrangement incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
MCCB 250 Amps, breaking capacity 25 KA, FP, 415V, G frame (fixed thermal and fixed magnetic setting) fixed in existing panel and connected to old existing cable incl necessary fixing arrangement incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
MCCB 350 Amps, breaking capacity 25 KA, FP, 415V, G frame (fixed thermal and fixed magnetic setting) fixed in existing panel and connected to old existing cable incl necessary fixing arrangement incl taking down old MCCB complete all as specified and as directed. Makes : L&T / Legrand / Schneider / Havells / ABB
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm including testing and commissioning, incl taking down old unserviceable jointing kit complete all as specified and directed
Cable jointing kit for 1.1 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Endura Pearl Plus' Cat Part No SL60WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton / Syska
Flood Light luminaries fitting 120 Watts LED die-cast aluminium IP65 flood light with high power LEDs as light source including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Jeta Pro Plus' Cat Part No LHFPCZBFP46J120 or equivalent in Wipro / Philips / Crompton / Syska
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. Note for Srl item No 92 & 93: Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only brick covering with width equal to length of bricks as mechanical protection to underground cable using old bricks retrieved during excavation, laid flat with width of brick perpendicular to length of cable, all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 16 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Loop type insulator, vitreous white, brown or green large size with overall dimension 90 x 140mm with clearance of hole 16mm complete all as specified and directed.
Galvanised iron tubing light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 02 Way, complete all as specified and as directed.
Taking down defective Solar Security Light fittings from any height, any places of any type, size, make and capacity, inspection of defective parts/ accessories etc as required at site including wiring etc testing and re-fixing at its original place on brackets, poles, walls, after making serviceable, complete all as specified & directed for following items :- Note : Defective parts/accessories shall be measured and paid separately under respective items as 'Supply only'
Supply only Luminaire LED 20 Watts complete all as specified and as directed. Make : Solar Tech/ Surya / Tata BP Solar
Supply only PCB Solar Charger Controller complete all as specified and as directed. Make : Solar Tech/ Surya / Tata BP Solar
Supply only SPV Modules 74 W 12V complete all as specified and as directed. Make : Solar Tech/ Surya / Tata BP Solar
Supply only Distilled Water of approved make complete all as specified and as directed.
Taking down and repair / maintenance of defective High Mast Light any type, make, size and capacity, inspection of defective parts / accessories etc. as required at site including wiring required, testing and re-fixing at its original position on brackets / poles after making the light serviveabe compete all as directed at site.
150 Watts Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66 Flood Light, suitable for highlighting architectural facade and general purpose lighting with all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076, fixed in ceilings after suitable cutout, complete all as specified and as directed. Make : Havells 'JETA IRIS' Cat Part No FLS150WLED757PSYMLTG or equivalent in Philips / Wipro / Crompton
darshan kumar gandhi
M/S BHARAT LIGHT ELECRIC.CO
Bidder Name
SWASTIK TRADERS
M/S BHARAT LIGHT ELECRIC.CO
darshan kumar gandhi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .