Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.6 CrQualified Make: CODAN
Model: CODAN & ENVOYX2 UNIT NO 17 A GROUND FLOOR SPLENDOR TRADE TOWER SECTOR 65 GOLF COURSE EXTENSION ROAD GURGAON HARYANA 122101 | GURUGRAM | HARYANA | 122101 | Make: CODAN
Model: CODAN & ENVOYX2 | ₹3.6 Cr | L1 | Qualified MSE, Category: General |
| 2 | L2₹4.4 Cr+₹82.7 L (23.0%)Qualified Make: Elbit
Model: Elbit & Micom 3F A 16 FRONT SIDE MOBILE COMMUNICATIONS INDIA PRIVATE LIMITED NARAINA INDUSTRIAL AREA PHASE II NEW DELHI PHASE II | Make: Elbit
Model: Elbit & Micom 3F | ₹4.4 Cr+₹82.7 L (23.0%) | L2 | Qualified MSE, Category: General |
| 3 | Disqualified Make: ICOM
Model: IC-8101 DATA PC 505 ASHOK BHAWAN 93 NEHRU PLACE SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: ICOM
Model: IC-8101 DATA PC | - | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
₹10.8 L
Closing Date
13 Nov 2018, 10:00 amClosed
HF Static Transceiversas per MHA QRs Experience with Gov. Required 3 Year (s) MSME Exemption For Years Of Experience And Turnover Yes HF Static Transceiversas Per MHA QRs ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFORMITY Conformity to technical requirements As per QR/specification for 'HF Static Transceivers'
prepared by Police Modernization Division
Mansingh Road
26
Jaisalmer House
New Delhi and approved by MHA as per letter No. B.V-7/201 7-18-C-(HF)-MHA-Prov- I-2075 Dated 31st July
2017. (Copy of QRs TDs uploaded in GeM portal) As per QR/specification for 'HF Static Transceivers'
2017. (Copy of QRs TDs uploaded in GeM portal) Availability of QR/specification for 'HF Static Transceivers' Yes * QR/specification has been seen
read and Yes * 1/5 understood Scope of supply of HF Static Transceivers covers all components complete as per governing QR/specification Yes * GENERIC RF Power 20 W to 100 W PEP (Low
Medium
High) As per User requirement with Programmable feature * Communication Security Vocoder based 128/256 bit digital encryption Vocoder based 128/256 bit digital encryption
SAG approved encryption ALE feature ALE 2G as per Appendix -A of MIL- STD-188-141 B and ALE 3G as per Appendix-C of MIL-STD-188-141 B * Frequency Hopping No Yes
with Hop Rate greater than or equal to 6 hops per second
No ACCESSORIES Suitable HF Broadband Dipole Antenna (Frequency range as per MHA approved QRs)-inclusive in the scope of supply true true
false Suitable Long Wire Antenna-inclusive in the scope of supply false true
false Suitable Halfloop Antenna-inclusive in the scope of supply false true
false Suitable Co-Axial Cable Assembly- inclusive in the scope of supply true true
false Length of Co-Axial Cable-inclusive in the scope of supply 30 0
30
50 Morse Key-inclusive in the scope of supply true true
false Suitable Head Gear- inclusive in the scope of supply true true
false 2/5 Programming Software with Cable true true
false Software for data communication true true
false Data Terminal (Specification as per MHA approved QRs) - inclusive in the scope of supply true true
false Suitable Swtch Mode Power Supply (SMPS)-inclusive in the scope of supply true true
false DC Power Supply (12 V 20 Amp) with Cable-inclusive in the scope of supply false true
false Data Cable for Data communication (USB) support at PC end-inclusive in the scope of supply true true
false Hard copy of Service Manual-inclusive in the scope of supply true true
false Hard copy of Technical Manual- inclusive in the scope of supply true true
false User handbook- inclusive in the scope of supply true true
false ENVIRONMENTAL Operating Temperature -30 deg. C to +55 deg. C * Storage Temperature -30 deg. C to +60 deg. C * Humidity 95% Non-Condensing @40 deg. C * Dust MIL-STD-810F or better * Vibration MIL-STD-810F or better * Shock MIL-STD-810F or better * Altitude MIL-STD-810F or better * TEST REPORTS Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the MHA true true
false 3/5 QR/specification If Yes
Test Report to be furnished to the Buyer on demand YES * Test Report Number and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Brajesh Singh 458441
Commandant 4 Signal Bn C.R.P.F
Neemuch (M.P)
548441 20 90 2 Amit Kumar 500005
Commandant 2 Signal Bn
CRPF
Post- Keshavgiri
Barkas
Hyderabad
Telangana
Pin- 500005 20 90 3 Chhotan Thakur 700091
Commandant 3 Signal Bn
Sector-V
Saltlake
Kolkata
West Bengal
Pin- 700091 20 90 4 MEGH RAJ 110072
Commandant 1 Signal Bn
Jharoda Kalan New Delhi- Pin- 110072 20 90 5 Vishal Kandwal 160002
COMDT 5 SIG BN
HALLOMAJRA
CHANDIGARH 20 90
758143
GEM/2018/B/106607
HF Static Transceiversas per MHA QRs
90 days
Madhya Pradesh; Neemuch, Madhya Pradesh; Ranga Reddy, Telangana; 24 Paraganas North, West Bengal; South West Delhi, Delhi; Chandigarh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| HF Static Transceiversas per MHA QRs Experience with Gov. Required 3 Year (s) MSME Exemption For Years Of Experience And Turnover Yes HF Static Transceiversas Per MHA QRs ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFORMITY Conformity to technical requirements As per QR/specification for 'HF Static Transceivers' | - | - | - |
| prepared by Police Modernization Division | - | - | - |
| Mansingh Road | - | - | - |
| 26 | - | - | - |
| Jaisalmer House | - | - | - |
| New Delhi and approved by MHA as per letter No. B.V-7/201 7-18-C-(HF)-MHA-Prov- I-2075 Dated 31st July | - | - | - |
| 2017. (Copy of QRs TDs uploaded in GeM portal) As per QR/specification for 'HF Static Transceivers' | - | - | - |
| 2017. (Copy of QRs TDs uploaded in GeM portal) Availability of QR/specification for 'HF Static Transceivers' Yes * QR/specification has been seen | - | - | - |
| read and Yes * 1/5 understood Scope of supply of HF Static Transceivers covers all components complete as per governing QR/specification Yes * GENERIC RF Power 20 W to 100 W PEP (Low | - | - | - |
| Medium | - | - | - |
| High) As per User requirement with Programmable feature * Communication Security Vocoder based 128/256 bit digital encryption Vocoder based 128/256 bit digital encryption | - | - | - |
| SAG approved encryption ALE feature ALE 2G as per Appendix -A of MIL- STD-188-141 B and ALE 3G as per Appendix-C of MIL-STD-188-141 B * Frequency Hopping No Yes | - | - | - |
| with Hop Rate greater than or equal to 6 hops per second | - | - | - |
| No ACCESSORIES Suitable HF Broadband Dipole Antenna (Frequency range as per MHA approved QRs)-inclusive in the scope of supply true true | - | - | - |
| false Suitable Long Wire Antenna-inclusive in the scope of supply false true | - | - | - |
| false Suitable Halfloop Antenna-inclusive in the scope of supply false true | - | - | - |
| false Suitable Co-Axial Cable Assembly- inclusive in the scope of supply true true | - | - | - |
| false Length of Co-Axial Cable-inclusive in the scope of supply 30 0 | - | - | - |
| 30 | - | - | - |
| 50 Morse Key-inclusive in the scope of supply true true | - | - | - |
| false Suitable Head Gear- inclusive in the scope of supply true true | - | - | - |
| false 2/5 Programming Software with Cable true true | - | - | - |
| false Software for data communication true true | - | - | - |
| false Data Terminal (Specification as per MHA approved QRs) - inclusive in the scope of supply true true | - | - | - |
| false Suitable Swtch Mode Power Supply (SMPS)-inclusive in the scope of supply true true | - | - | - |
| false DC Power Supply (12 V 20 Amp) with Cable-inclusive in the scope of supply false true | - | - | - |
| false Data Cable for Data communication (USB) support at PC end-inclusive in the scope of supply true true | - | - | - |
| false Hard copy of Service Manual-inclusive in the scope of supply true true | - | - | - |
| false Hard copy of Technical Manual- inclusive in the scope of supply true true | - | - | - |
| false User handbook- inclusive in the scope of supply true true | - | - | - |
| false ENVIRONMENTAL Operating Temperature -30 deg. C to +55 deg. C * Storage Temperature -30 deg. C to +60 deg. C * Humidity 95% Non-Condensing @40 deg. C * Dust MIL-STD-810F or better * Vibration MIL-STD-810F or better * Shock MIL-STD-810F or better * Altitude MIL-STD-810F or better * TEST REPORTS Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the MHA true true | - | - | - |
| false 3/5 QR/specification If Yes | - | - | - |
| Test Report to be furnished to the Buyer on demand YES * Test Report Number and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Brajesh Singh 458441 | - | - | - |
| Commandant 4 Signal Bn C.R.P.F | - | - | - |
| Neemuch (M.P) | - | - | - |
| 548441 20 90 2 Amit Kumar 500005 | - | - | - |
| Commandant 2 Signal Bn | - | - | - |
| CRPF | - | - | - |
| Post- Keshavgiri | - | - | - |
| Barkas | - | - | - |
| Hyderabad | - | - | - |
| Telangana | - | - | - |
| Pin- 500005 20 90 3 Chhotan Thakur 700091 | - | - | - |
| Commandant 3 Signal Bn | - | - | - |
| Sector-V | - | - | - |
| Saltlake | - | - | - |
| Kolkata | - | - | - |
| West Bengal | - | - | - |
| Pin- 700091 20 90 4 MEGH RAJ 110072 | - | - | - |
| Commandant 1 Signal Bn | - | - | - |
| Jharoda Kalan New Delhi- Pin- 110072 20 90 5 Vishal Kandwal 160002 | - | - | - |
| COMDT 5 SIG BN | - | - | - |
| HALLOMAJRA | - | - | - |
| CHANDIGARH 20 90 | - | - | - |
₹10.8 L
13 Nov 2018
23 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_758143.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .