| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹3.4 L+₹33,358.60 (11.1%)Accepted-Finance | 2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | Vinoth Electricals L1 | GAJENDRAA ELECTRIC COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Transformer Oil filtration through hot stream Line process for 1 Nos. of 500 KVA Transformer up to the required value of 40KV for one minute including Transportation charges for filtering unit & oil testing kit. | 500 | Ltr | 18 ₹9,000 Lowest | 19 ₹9,500 |
| 2.00 | Testing of BDV and Acidity for transformer oil and issuing necessary test certificate. | 1 | Set | 1,250 ₹1,250 Lowest | 1,275 ₹1,275 |
| 3.00 | Renewal by supply and fixing of new Transparent type Silicajel breather suitable for existing transformer with silicajel and oil cup. | 1 | Ea | 2,850 ₹2,850 Lowest | 3,000 ₹3,000 |
| 4.00 | Renewal by topping up of New transformer oil up to the required level for Transformer conservators | 25 | Ltr | 248 ₹6,200 Lowest | 255 ₹6,375 |
| 5.00 | Charges for complete servicing of LT 440V 50Hz Air circuit breaker including thorough inspection of the ACB and carrying out the following maintenance nature of works for proper and efficient functioning of ACBs all as specified and as directed
Check, clean, align / tighten of the following:
a. All terminals and moving contacts,
b. All terminals UV/Shunt trip coil, check insulation resistance
c. All terminals of Breaker mounted release and current Tr.
d. All terminals of internal wiring circuits of complete panel
e. Cleaning Arc Chutes and checking LV Inc/OG connections
f. checking its mechanism alignment & draw-in arrangement
and apply petroleum jelly to all surfaces of contacts check insulation resistance and set for proper functioning. | 1 | Ea | 8,000 ₹8,000 Lowest | 9,700 ₹9,700 |
| 6.00 | Providing 230V AC, 200W heavy duty space heaters with 2 KV for 1 minute dielectric strength with IP 20 Protection type for 11 KV HT VCB Panel, after removing the existing damaged heaters. | 12 | Ea | 3,500 ₹42,000 Lowest | 3,750 ₹45,000 |
| 7.00 | Providing 250V AC 15 Amps, Maximum head tempearture 85°C with 2 KV dielectric strength thermostat for temperature control of space heaters in HT VCB Panels | 6 | Ea | 1,450 ₹8,700 Lowest | 1,530 ₹9,180 |
| 8.00 | Renewal by Supply and fixing of new Power pack with following Specification
Output Voltage – 110 V DC (Stored & Non Stored)
In Put Voltage: 230/110 V AC 1 Ph.
Out Put 2 : 100 Watts’s (Non-Stored)
Output 1 : 060 Watts Stored | 1 | Ea | 29,200 ₹29,200 Lowest | 33,150 ₹33,150 |
| 9.00 | Servicing of HT Vacuum Circuit Breaker / Load Break Switch completely, by checking all the fixed Male, Female contacts and Moving Male and female contacts, removing all the carbon and making the surface of the contacts clean and applying necessary petroleum Jelly for the contacts and lubricating the other mechanical parts for easy operation, etc., complete | 5 | Ea | 14,000 ₹70,000 Lowest | 15,300 ₹76,500 |
| 10.00 | Renewal by supply and fixing of LED Pilot Lamps for HT and LT panels with appropriate colours (110 V AC/DC) | 25 | Ea | 340 ₹8,500 Lowest | 357 ₹8,925 |
Tender Value
Refer Docs
EMD Value
₹3,290
Closing Date
25 Sept 2026, 3:00 pmClosed
Executive Engineer electrical
Executive Engineer electrical Division 2, PWD Chepauk, Chennai-05.
Special Repairs to 1 No of 11KV Transformer 1 No of LT ACBs, 5 Nos HT VCBs and its works its King Institute Campus, Guindy, Chennai-600032.
2026_PWD_704224_1
19E2627
Open Tender
Electrical Works
Lump-sum
30 days
Chennai
Check Tender Documents
3 documents required · 3 mandatory
₹0
₹3,290
30 Sept 2026
12 Sept 2026
25 Sept 2026
12 Sept 2026
25 Sept 2026
12 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Transformer Oil filtration through hot stream Line process for 1 Nos. of 500 KVA Transformer up to the required value of 40KV for one minute including Transportation charges for filtering unit & oil testing kit. | 500 | Ltr | - | - |
| 2 | Testing of BDV and Acidity for transformer oil and issuing necessary test certificate. | 1 | Set | - | - |
| 3 | Renewal by supply and fixing of new Transparent type Silicajel breather suitable for existing transformer with silicajel and oil cup. | 1 | Ea | - | - |
| 4 | Renewal by topping up of New transformer oil up to the required level for Transformer conservators | 25 | Ltr | - | - |
| 5 | Charges for complete servicing of LT 440V 50Hz Air circuit breaker including thorough inspection of the ACB and carrying out the following maintenance nature of works for proper and efficient functioning of ACBs all as specified and as directed
Check, clean, align / tighten of the following:
a. All terminals and moving contacts,
b. All terminals UV/Shunt trip coil, check insulation resistance
c. All terminals of Breaker mounted release and current Tr.
d. All terminals of internal wiring circuits of complete panel
e. Cleaning Arc Chutes and checking LV Inc/OG connections
f. checking its mechanism alignment & draw-in arrangement
and apply petroleum jelly to all surfaces of contacts check insulation resistance and set for proper functioning. | 1 | Ea | - | - |
| 6 | Providing 230V AC, 200W heavy duty space heaters with 2 KV for 1 minute dielectric strength with IP 20 Protection type for 11 KV HT VCB Panel, after removing the existing damaged heaters. | 12 | Ea | - | - |
| 7 | Providing 250V AC 15 Amps, Maximum head tempearture 85°C with 2 KV dielectric strength thermostat for temperature control of space heaters in HT VCB Panels | 6 | Ea | - | - |
| 8 | Renewal by Supply and fixing of new Power pack with following Specification
Output Voltage – 110 V DC (Stored & Non Stored)
In Put Voltage: 230/110 V AC 1 Ph.
Out Put 2 : 100 Watts’s (Non-Stored)
Output 1 : 060 Watts Stored | 1 | Ea | - | - |
| 9 | Servicing of HT Vacuum Circuit Breaker / Load Break Switch completely, by checking all the fixed Male, Female contacts and Moving Male and female contacts, removing all the carbon and making the surface of the contacts clean and applying necessary petroleum Jelly for the contacts and lubricating the other mechanical parts for easy operation, etc., complete | 5 | Ea | - | - |
| 10 | Renewal by supply and fixing of LED Pilot Lamps for HT and LT panels with appropriate colours (110 V AC/DC) | 25 | Ea | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_846411.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.70 MB
BOQ_846411.xls
BOQ • 0.31 MB
TenderDcouments19E.pdf
Tender Documents • 0.91 MB
corrigenum2.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .