Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹35.2 LQualified | ₹35.2 L | L2 | Qualified MSE, MII, Category: General |
| 2 | L3₹34.3 LQualified | ₹34.3 L Quoted ₹36.4 L | L3 | Qualified MSE, MII, Category: General |
| 3 | Qualified | - | - | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
13 May 2022, 7:00 pmClosed
Brand Type Unbranded
3392340
GEM/2022/B/2168832
Supply and fixing polycarbonate themoplastic junction box IP 65 protection Mini size 160x200x98mm s
90 days
Punjab; Jalandhar
Total value wise evaluation
BOQ
4 documents required · 4 mandatory
40%
Exempted
13 May 2022
11 May 2022
13 May 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply and fixing polycarbonate themoplastic junction box IP 65 protection Mini size 160x200x98mm size | Supply & fixing polycarbonate themoplastic junction box IP 65 protection Mini size 160x200x98mm size. Junction box shall be UV resistance test IEC 61439 1 anti acid, anti corrosive, glow wire test 960 degrees, weather proof, rust proof dust proof, water proof, mchanical load shall be IK08 (5 Jpole. Accordance IEC 62262. The Junction box with four corner SS screw Tite with four side walls shall ave knock outs for cable entry & provision for Din rail. The gasket shall be internally embedded made of polyurethane. The junction shall have 2 Nos cable cable Glands suitable as per cable size & fixing with ple mounting clamp. The junction box with terminal strip 100Amp for cable loop in/out with thimbles and 1 Nos 10Amp MCB SP and with complete with fixing arrangement such as nut, bolt and clamp etc with all accessories.Make-Hensel/Schnieder/ABB/Siemens | 500 | Each | ageem@adampur | 90 |
| 2 | Supply and fixing 1100 volt grade heavy duty cable pvc insulated aluminium conductor served with inner sheathing | Supply and fixing 1100 volt grade heavy duty cable pvc insulated aluminium conductor served with inner sheathing of pvc tape and overall pvc sheathed one twin core cable flat or circular of size 10sqmm complete all as specified and directed. | 300 | RM | ageem@adampur | 90 |
| 3 | M and L Double Wall Corrugated DWC for pressure rating 6Kg Cm2 laid in trench of size 40mm dia with all fittings | M&L Double Wall Corrugated (DWC) for pressure rating 6Kg/Cm2 laid in trench of size 40mm dia with all fittings for proptiction of earth strips for roof conductor of Igloo building. | 300 | RM | ageem@adampur | 90 |
| 4 | M and L Double Wall Corrugated DWC for pressure rating 6Kg Cm2 laid in trench of size 50mm dia with all fittings | M&L Double Wall Corrugated (DWC) for pressure rating 6Kg/Cm2 laid in trench of size 50mm dia with all fittings for proptiction of earth strips for roof conductor of Igloo building. | 50 | RM | ageem@adampur | 90 |
| 5 | Earthing complete with gavalised steel earth plate electrode 60x60cm. 6mm thick buried directly in ground earth pit not less than 2.25 meter | Earthing complete with gavalised steel earth plate electrode 60x60cm. 6mm thick buried directly in ground earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to gavalised earth lead wire 4.0mm dia by means of bolt nuts ,check nuts washers of gavalised iron or steel all as shown in electrical plate No.3 connected to earth test point all as specified or indicated including testing on completion. | 10 | Each | ageem@adampur | 90 |
| 6 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables and getting out in soft/loose soil complete all as specified and directed. | 254 | Cum | ageem@adampur | 90 |
| 7 | Returning filling in layers including leveling watering and well ramming in layers not exc. 25 cm thick | Returning filling in layers including leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. | 118 | Cum | ageem@adampur | 90 |
| 8 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed. | 111 | Cum | ageem@adampur | 90 |
| 9 | Material and labour for sand cushion with a layer of sand 80mm thick before laying of cable and 15cm thick punned | Material and labour for sand cushion with a layer of sand 80mm thick before laying of cable and 15cm thick punned down to 100 mm thick after laying of cable in trenches/DUCTS COMPLETE ALL AS SPECIFICATION Note Punned down thicknes overall 18cm shall be considered for measurement and payment. | 91 | Cum | ageem@adampur | 90 |
| 10 | Supply and laying old size sub B class bricks laid flat in treached over the cable with the length of brick | Supply & laying old size sub B class bricks laid flat in treached over the cable with the length of brick perpendicular to the direction of cable length adjacent/abutting each other complete all as specified and directed ny engineer in charge | 10 | Per 1000 Nos | ageem@adampur | 90 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3392340.pdf
GEM_BID
replacement-of-junction-box-final_2022-05-11-12-29-54_0b55ab1d791c52fe1e68a1d3ef1babd6.pdf
BOQ
replacement-of-junction-box-17-1_2022-05-11-12-29-54_26e7fe508f2a978e30be0223b918a305.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid