| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.6 LAccepted-Finance H 29 COOLIE LINE METTUR DAM 636 401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | 1 | Accepted-Finance satisfied | |
| 2 | 2₹10.4 L+₹1.8 L (21.2%)Accepted-Finance 72 133 THOTTILPATTY SALEM CAMP METTUR DAM 636456 | METTUR DAM | SALEM | TAMIL NADU | 636456 | 2 | Accepted-Finance satisfied |
| Sl No | Description | Qty | Unit | MEGALA ENTERPRISES L1 | KSS Engineering Contractor L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for leading, lifting and arranging platform and scaffolding wherever required in the boiler and dismantling after completion of work. | 1 | No. | 15,000 ₹15,000 Lowest | 16,000 ₹16,000 |
| 2.00 | Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate and transporting of scrap to Central Stores/M.T.P.S-I. | 100 | m2 | 2,000 ₹2,00,000 Lowest | 2,500 ₹2,50,000 |
| 3.00 | Charges for transporting of 6mm M.S./ Chequered plates from Central Stores/MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded top portions of the duct above 1.5 metre level and welding the same. | 100 | m2 | 2,500 ₹2,50,000 Lowest | 3,500 ₹3,50,000 |
| 4.00 | Charges transporting the materials to outside workshop cutting in to required size, bending to the required size and profile, transporting back to MTPS boiler area. | 1.5 | Tons | 22,000 ₹33,000 Lowest | 24,000 ₹36,000 |
| 5.00 | Charges for transporting the refractory from store and unloading at site, leading, lifting , stacking at 7m to 52m and removing the waste refractory from boiler lowering to the ground floor, loading to tipper and disposing at waste disposal area of MTPS-I | 3,000 | kg. | 5 ₹15,000 Lowest | 6 ₹18,000 |
| 6.00 | Charges for chipping removal of old defective refractory, cleaning, surface preparation, mixing the refractory with water application and curing the patch worked refractory in Boiler at various elevation | 3,000 | kg. | 18 ₹54,000 Lowest | 20 ₹60,000 |
| 7.00 | Corten steel sheet 3.15 mm thick | 2 | Tons | 74,000 ₹1,48,000 Lowest | 75,000 ₹1,50,000 |
| 8.00 | Wire mesh length: 2500 mm width 750mm. Weaving square gap 19mm mterial SS 316 | 6 | Nos. | 11,000 ₹66,000 Lowest | 12,500 ₹75,000 |
| 9.00 | SUPER CASTABLE REFRACTORY
ACE Fire crete (super)/ TATA refractories Service temp 14500 C Al2 O3 -70% ,Fe2 O3 -2.5 to 5%,Si O2 -11.5%,
Dry density minimum 2500 kg/m3,
Grain size – maximum 5 mm,
CCS/kg/cm2 at service temp 1450oc - 350 kg/cm2
with material/ manufacturer's test certificate | 3,000 | kg. | 21 ₹63,000 Lowest | 23 ₹69,000 |
| 10.00 | Cutting gas | 1 | set | 4,000 ₹4,000 Lowest | 5,000 ₹5,000 |
Tender Value
Refer Docs
EMD Value
₹7,900
Closing Date
24 Nov 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM AOH 2025 Unit III Boiler pressure parts Cutting and removing of heavily wornout CRH and HRH tubes roof plate and fabrication and erection of new corten steel sheet 3.15mm thick and allied works in the penthouse area at 52 mtr level
2025_EB_621935_1
CE / MTPS-I / SE / M-I / BM /OT. 365 / 2025-26
Open Tender
Power/Energy Projects/Products
Works
25 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹7,900
Yes
26 Nov 2025
10 Nov 2025
25 Nov 2025
10 Nov 2025
24 Nov 2025
10 Nov 2025
Amount
Charges for leading, lifting and arranging platform and scaffolding wherever required in the boiler and dismantling after completion of work.
Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate and transporting of scrap to Central Stores/M.T.P.S-I.
Charges for transporting of 6mm M.S./ Chequered plates from Central Stores/MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded top portions of the duct above 1.5 metre level and welding the same.
Charges transporting the materials to outside workshop cutting in to required size, bending to the required size and profile, transporting back to MTPS boiler area.
Charges for transporting the refractory from store and unloading at site, leading, lifting , stacking at 7m to 52m and removing the waste refractory from boiler lowering to the ground floor, loading to tipper and disposing at waste disposal area of MTPS-I
Charges for chipping removal of old defective refractory, cleaning, surface preparation, mixing the refractory with water application and curing the patch worked refractory in Boiler at various elevation
Corten steel sheet 3.15 mm thick
Wire mesh length: 2500 mm width 750mm. Weaving square gap 19mm mterial SS 316
SUPER CASTABLE REFRACTORY ACE Fire crete (super)/ TATA refractories Service temp 14500 C Al2 O3 -70% ,Fe2 O3 -2.5 to 5%,Si O2 -11.5%, Dry density minimum 2500 kg/m3, Grain size – maximum 5 mm, CCS/kg/cm2 at service temp 1450oc - 350 kg/cm2 with material/ manufacturer's test certificate
Cutting gas
Ms welding electrode 4 mm
T & Ps and consumables
KSS Engineering Contractor (BID ID -1519128)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_743628.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .