Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-Not within the territorial jurisdiction of the Assembly Constituency as per the AP Distt based Entrepreneurs and Professionals incentives, Dev & Promotional Act 2015 (Amended Act 2020 (Act No. 7 of 2020) and complain letter No. Nill, Dtd: 23/03/2026. |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-Not within the territorial jurisdiction of the Assembly Constituency as per the AP Distt based Entrepreneurs and Professionals incentives, Dev & Promotional Act 2015 (Amended Act 2020 (Act No. 7 of 2020) and complain letter No. Nill, Dtd: 23/03/2026. |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-EMD Not submitted. |
Tender Value
Refer Docs
EMD Value
₹6.4 L
Closing Date
20 Mar 2026, 4:00 pmClosed
EE, Doimukh Division, APPWD, Doimukh
O/o the EE, Doimukh Division, APPWD, Doimukh
Establishment of NCC Academy at Balijan.
2026_PWDAP_3082_1
DD/2025-26/17
Open Tender
Civil Works
Item Rate
730 days
Balijan
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
EE PWD Doimukh
₹6.4 L
24 Mar 2026
14 Mar 2026
24 Mar 2026
14 Mar 2026
20 Mar 2026
14 Mar 2026
SH :- C/o Mess Hall (400 Capacity).
SH:I:Earth Work
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
SH:II:Stone Work
Random rubble masonary with hard stone in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand) including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 stone aggregate 20mm nominal size) at plinth level.
SH:III:Concrete Work
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundation & Plinth
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundation & Plinth
SH:IV:RCC Work
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.1) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. 1) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting proping etc. and removal of form work for for foundation & plinth.
a) Foundation & Plinth
b) Column,Pillars,posts and Struts etc.
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
d) Lintels, beams, girders, bressumers and cantilevers etc.
Reinforcement of RCC work including bending, binding and placing in position complete.
SH:V:Brick Work
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
SH:VI:Wood Work
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 30mm thick including anodized aluminium butt hinges with necessary screws.
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.(Plain Grill)
SH:VII:Fittings
Providing and fixing Aluminium tower bolts (barrel type) with necessary screws etc complete.a) 300 x 10 mm
Providing and fixing Aluminium handles with necessary screws etc complete.a) 125 mm
Providing and fixing M.S Door latch with necessary screws etc complete.a) 300 x 20 x 6 mm
SH:VIII:Flooring
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laidon 20 mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.b) Size of Tile 600x600 mm
SH:IX:Steel Work
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
SH:X:Roofing
Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
SH:XI:Finishing
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Neat Cement Punning
Providing two coats of acrilic water based wall putty / wall filler of Asian paints / Berger/ Dulux over concrete/ Cement plaster/ bricks walls and ceiling both internal and external after removing all thee loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with help of sufficient quantity of clear water as specified and directed by the department.
Applying one coat of Cement primer of approved brand and manufactured on wall surface.
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Varnishing (two or more coats) with superior quality spar varnish of approved brand and manufacture brand and manufacture on new work including an under coat of flatting varnish with glue sizing.
SH:XII:Miscellenious Work
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
SH:XIII:Drainage Work
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design.
SH:XIV:Water Supply
Providing and fixing brass bib cock of approved quality.20mm nominal bore
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) pipes, having thermal stability of hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as direction of Engineer in charge.a)Concealed work including cutting chases & making good the wall etc.i)20mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) pipes, having thermal stability of hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as direction of Engineer in charge.a)External Works
a)50mm nominal outer dia pipes.
b)40mm nominal outer dia pipes.
Providing and fixing long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. a)15mm nominal bore
SH:XV:Sanitary Installation
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan
Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. A)250 x 130 x 30 mm
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a)Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality
SH:XVI:Aluminium Work
Providing and fixing aluminium work for doors, windows, ventilators and partitins with extruded built up standard tubular section/ appropriate Z sections and other sections of approved make conforming to IS : 1285, fixed with rawl plugs and screw or with fixing clips, or with expansion hold fasteners including necessary filling up to gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately).a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium doors, windows, Ventilator shutters and partition etc. With PVC / neoprene gasket etc. Complete as per the architectural drawings and the direction of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.a) With float glass panes of 4.0 mm thickness
SH:XVII:PVC & uPVC Work
Door/ Window/ Ventilator frames:- Providing and fixing factory made PVC door frame made of PVC extruded section of size 75mm X 53mm, having wall thickness 2.0mm (±0.2mm). Both vertical sides of the frame reinforced with PVC profile of crossection size 28mm X 30mm X 2mm thickness (±0.2mm) and 75mm X 200mm long, including reinforcing both ends of the top frame with PVS profile. PVC door frame and PVC reinforcement profile to be metered cut, jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos and sizes of anchor dashes fastener all complete as per manufacturer's specification and direction of engineer-in-charge.
Entry / Exit Door Shutter:- Providing and fixing 37mm thick factory made PVC door shutter, styles and rails made of PVC hollow extruded printed and leminated section having overall dimention 115mm X 37mm with wall thickness 2mm (±0.2mm) with inbuilt beading on one side, the style and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75mm X 200mm long with cross section size of 28mm X 30mm having wall thickness 2mm (±0.2mm). Styles, rails and reinforcement to be fusion welded together. Only hinge side verticle style to be reinforced with PVC profile reinforced in full length. printed and leminated PVC lock rail of size 110mm X 37mm having wall thickness 2mm (±0.2mm) to be welded horizontally with the verticle styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20mm printed & laminated and inserting 2nos 6mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer' specification and direction of engineer-in-charge.
SH: INTERNAL ELECTRIFICATION
SH:I:WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
i)Group A
ii)Group B
iii)Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVCbinsulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (5A Plug)
ii)2 X 4 sq. mm + 1 X 4 sq. mm earth wire (For Power Point)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
a) 5/6 A switch
b)15/16 A switch
c)3 pin 5/6 A socket outlet
d)6 pin 15/16 A socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.i) 510 mm sweep
SH:II:MCCB, MCB & DB'S
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
i)32 A TP&N
ii)63 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
i)100 A, 16 KA,TPMCCB
ii)125 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
i)6 way , Double door
ii) 8 way , Double door
SH:III:Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SH:IV:Fittings
Supplying of 1200 mm AC Sweep Ceiling Fan (Orient/Usha Mae)
Modular fan regulator.
20 Watts LED Bulps Bajaj/Phillips Make)
20 Watts LED Bulps Bajaj/Phillips Make)
Florescent tube set fitting (Bajaj/Phillips Make)
Exhaust fan
SH:C/o 300 Bedded (G+3) Girls Hostel(Phase-I,GF Only)
SH:I:Earth Work
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
SH:II: Stone Work
Random rubble masonary with hard stone in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand) including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 stone aggregate 20mm nominal size) at plinth level.
SH:III: Concrete Work
Providing and laying of cement concrete 1 : 3 : 6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.a)Foundation and Plinth.
Providing and laying of cement concrete 1 : 1.5 : 3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in a) Foundation and Plinth.
SH:IV: RCC Work
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement..a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting proping etc. and removal of form work for for foundation & plinth.
a) Foundation and plinth
b) Column, pillars, posts and struts etc.
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
d) Lintels, beams, girders, bressumers and cantilevers etc.
e) Stairs (excluding landings) except spiral stair cases
Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
SH:V: Brick Work
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
SH:VI: Wood Work
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 40mm thick including anodized aluminium butt hinges with necessary screws.
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.(Plain Grill)
SH:VII: Fittings
Providing and fixing Aluminium tower bolts (barrel type) with necessary screws etc complete.a) 250 x 10 mm
Providing and fixing Aluminium handles with necessary screws etc complete.a) 125 mm
Providing and fixing M.S Door latch with necessary screws etc complete a)300 x 20 x 6mm
SH:VIII: Flooring
Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: b) Medium shade using approximately 50% white cement and 50% ordinary cement
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laidon 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.d) Size of Tile 1000x1000 mm
Kota stone slab 20mm thick in riser of steps, skirting, dado and pillars laid on 12mm (avg) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shape of the slabs, including rubbing and polishing complete.
SH:IX: Steel Work
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolt complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in0charge, (for payment purpose only weight of stainless steel members shall be consider excluding fixing accessories such as nuts, bolts, fasteners etc.).
SH:X: Finishing Work
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Neat Cement Punning
Providing two coats of acrilic water based wall putty / wall filler of Asian paints / Berger/ Dulux over concrete/ Cement plaster/ bricks walls and ceiling both internal and external after removing all thee loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with help of sufficient quantity of clear water as specified and directed by the department.
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Varnishing (two or more coats) with superior quality spar varnish of approved brand and manufacture brand and manufacture on new work including an under coat of flatting varnish with glue sizing.
SH:XI: Miscelleneous Works
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
SH:XII: Drainage Works
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design.
SH:XIII: Water Supply
Providing and fixing brass bib cock of approved quality a) b) 20 mm nominal bore
Providing and fixing CP brass shower rose with 15mm or 20mm dia inlet a)b) 150 mm dia
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) pipes, having thermal stability of hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as direction of Engineer in charge.a) Internal work - Exposed on wall.b) 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) pipes, having thermal stability of hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as direction of Engineer in charge.a) External work
a) 50 mm nominal outer dia Pipes
b) 40 mm nominal outer dia Pipes
Providing and fixing long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.a) 15 mm nominal bore
SH:XIV: Sanitary Installation
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) One urinal basin with 5 Litres CI automatic flushing cistern
Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC a) 250 x 130 x 30 mm
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality
SH:XV: Aluminium Works
Providing and fixing aluminium work for doors, windows, ventilators and partitins with extruded built up standard tubular section/ appropriate Z sections and other sections of approved make conforming to IS : 1285, fixed with rawl plugs and screw or with fixing clips, or with expansion hold fasteners including necessary filling up to gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately).Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15)
Providing and fixing glazing in aluminium doors, windows, Ventilator shutters and partition etc. With PVC / neoprene gasket etc. Complete as per the architectural drawings and the direction of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.
SH:XVI: PVC & uPVC Works
Door/ Window/ Ventilator frames:- Providing and fixing factory made PVC door frame made of PVC extruded section of size 75mm X 53mm, having wall thickness 2.0mm (±0.2mm). Both vertical sides of the frame reinforced with PVC profile of crossection size 28mm X 30mm X 2mm thickness (±0.2mm) and 75mm X 200mm long, including reinforcing both ends of the top frame with PVS profile. PVC door frame and PVC reinforcement profile to be metered cut, jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos and sizes of anchor dashes fastener all complete as per manufacturer's specification and direction of engineer-in-charge.
Entry / Exit Door Shutter:- Providing and fixing 37mm thick factory made PVC door shutter, styles and rails made of PVC hollow extruded printed and leminated section having overall dimention 115mm X 37mm with wall thickness 2mm (±0.2mm) with inbuilt beading on one side, the style and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75mm X 200mm long with cross section size of 28mm X 30mm having wall thickness 2mm (±0.2mm). Styles, rails and reinforcement to be fusion welded together. Only hinge side verticle style to be reinforced with PVC profile reinforced in full length. printed and leminated PVC lock rail of size 110mm X 37mm having wall thickness 2mm (±0.2mm) to be welded horizontally with the verticle styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20mm printed & laminated and inserting 2nos 6mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer' specification and direction of engineer-in-charge.
SH: INTERNAL ELECTRIFICATION
SH:I:WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
i)Group A
ii)Group B
iii)Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVCbinsulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (5A Plug)
ii)2 X 4 sq. mm + 1 X 4 sq. mm earth wire (For Power Point)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
a) 5/6 A switch
b)15/16 A switch
c)3 pin 5/6 A socket outlet
d)6 pin 15/16 A socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.i) 510 mm sweep
SH:II:MCCB, MCB & DB'S
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
i)32 A TP&N
ii)63 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
i)100 A, 16 KA,TPMCCB
ii)125 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
i)6 way , Double door
ii) 8 way , Double door
SH:III:Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SH:IV:Fittings
Supplying of 1200 mm AC Sweep Ceiling Fan (Orient/Usha Mae)
Modular fan regulator.
20 Watts LED Bulps Bajaj/Phillips Make)
20 Watts LED Bulps Bajaj/Phillips Make)
Florescent tube set fitting (Bajaj/Phillips Make)
Exhaust fan
stage.html
html • 0.02 MB
finance_3282.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_3282.xls
BOQ • 0.41 MB
SBD.pdf
Tender Documents • 19.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .