Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹23.5 L+₹38,248 (1.66%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE AF Gorakhpur
GE AF Gorakhpur
REPAIR/ MAINT OF LT CABLE, PANEL AND WELCOME MAINT OF OFFRS INCLUDING FAN AND GEYSER AT 4 AFSB VARANASI UNDER GE AF GORAKHPUR
2024_MES_665207_1
9202/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF Gorakhpur
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE AF Gorakhpur
₹76,000
Yes
29 Oct 2024
10 Jul 2024
6 Sept 2024
10 Jul 2024
4 Sept 2024
24 Jul 2024
10 Jul 2024 - 17 Jul 2024
Amount
M&L for preparation old decorated surfaces of any description, including cornices and applying one coat of white wash on walls complete all as specified and as directed.
All as per item No. 1 here in above but on ceiling surfaces complete all as specified and as directed.
M&L for preparing of old decorated surfaces and applying one coat of cement based paint on walls complete all as specified and as directed.
M&L for preparing of old decorated surfaces and applying two coat of cement based paint on walls complete all as specified and as directed.
M&L washing, rubbing down and stopping of distempered and painted surfaces of walls including cornices etc and applying one coat of oil bound distemper white or tinted with roller. Complete all as specified and as directed.
M&L washing, rubbing down and stopping of distempered and painted surfaces of walls including cornices etc and applying one coat of oil bound distemper white or tinted with roller over 1mm thick wall care putty. Complete all as specified and as directed.
All as per item No 4 here in above but one coat of oil bound distemper on ceiling surface,Complete all as specified and as directed.
All as per item No 4 here in above but one coat of oil bound distemper on ceiling surface over 1mm thick wall care putty complete all as specified and as directed.
All as per item No 4 here in above but two coats of oil bound distemper on walls over 1mm thick wall care putty. complete all as specified and as directed.
All as per item No 6 here in above but two coats of oil bound distemper on ceiling surfaces over 1mm thick wall care putty complete all as specified and as directed.
M&L for preparation of old painted wooden based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description, over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed .
M&L for complete removal of existing treatment on wall/roof projections for by scrapping with mechanical sander (having mechanical vaccume mechanism) with sanding pad applying one coat of100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489.2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Comany Depot Tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over a coat of 1mm thick wall care putty . Note:- Primer and emulsion to be carried out through air less spray machine (Mechanical means). Complete all as specified and directed.
M&L for complete removal of existing treatment on wall/Columns/Beam/roof projections for by scrapping with mechanical sander (having mechanical vaccume mechanism) with sanding pad applying one coat of10 0% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489.2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Comany Depot Tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over a coat of 1mm thick wall care putty beyond height 10m and upto 22 m including necessary scaffolding/ shuttering for over head water tank complete all as specified and directed. Note:- Primer and emulsion to be carried out through air less spray machine (Mechanical means). Complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified as directed.
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified as directed.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with liquid WPC @ 150 ml per 50 kg of cement or as per manufacturer instructions ( WPC will be measured and paid separately), finished even and smooth without using extra cement complete all as specified as directed.
M&L Rendering 5mm thick in CM 1:3 on celing, finished even and smooth without using extra cement complete all as specified as directed.
M&L for two coat of oil bound distemper on walls over one coat of 1mm thick wall care putty after complete preparation on new plastered surfaces of walls.
M&L for applying two coat of Oil bound distemper over 1mm wall care putty on ceiling after complete preparation on new plastered surfaces of ceiling.
M&L for two coat of cement base paint over a coat of alkali resistant cement primer on newly plastered surface including preparation of undecorated surface complete all as specified and as directed.
Supply only liquid water proofing compound.
Supply and fix in repairs 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe fixed in repairs all as specified and directed. Make- Essco or equivalent
Supply and fix in repairs 15 mm bore angle cock (Two -in-way) brass chromium plated fancy type, screwed for iron pipe fixed in repairs all as specified and directed. Make- Essco or equivalent
S&F in repair vitreous china ware wash hand basin 550mm x 400 mm size, white, flat back or angle including removing the existing one complete and refixing with new bracket and making good all connections. Make- Cera/Hindware/Parreware.
Supply and fix in repair 32 mm dia bore waste fittings brass chromium plated fixed to wash hand basin with long screwed shanks and fly nuts flange and bedded in run lead cement and other end fixed complete.
S & F in repair 32mm Dia and 60 to 75 cm long PVC waste pipe with fly nut, coupling for sinks/urinals or wash basins etc.
Supply and fix in repairs 15mm bore pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts complete screwed for iron pipe in repairs all as specified and directed. Make-Essco or equivalent
S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floor complete all as specified as directed.
M & L in repair white /black plastic seat cover solid confirming to ISI complete and taking down old all as specified and directed. Make-Cera/Hindware
S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. Make-Cera/Hindware
S&F in repair brass CP shower rose with arms 75 mm size fixed to pipe all as in repairs specified and directed.
S&F in repairs 20 mm dia tubular towel rail brass cromium plated, D type, 60cm long between flanges including one pair of brackets all as specified and directed.
S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed. Complete all as specified and directed. Make- Essco or equivalent.
S&F in repairs angle valves, 15 mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed all as specified and directed. Make- Essco or equivalent.
S&F in repair PVC toilet cup board cabinet, with shutters having mirror on shutter of size 47cm x 35cm x 15cm Make - Prayag /Shakti
S&F in repairs sheet glass shelf assembly consisting of 5.50mm thick glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long all as specified.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screw complete all as specified and directed.
S&F in repair Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed."
Tank cleaning and removing all scale etc from tanks and from monuhs of circulating pipes etc, exc 250 and n exc 500 ltr capacity, complete all as specified and directed.
Tank cleaning and removing all scale from tanks and from mouths of circulating pipes etc, exc 500 and n exc1000 ltr capacity, complete all as specified and directed.
S&F in repair 25mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. .complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description n.exc 1 sq.m each complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sq.m and n.exc 2sq.m each.complete all as specified and directed.
Taking down and refixing in same opening or easing & adjusting shutters of any description n.exc 1 sq.m each complete all as specified and directed.
Taking down and refixing in same opening or easing & adjusting shutters of any description exc 1 sq.m &n.exc 2sq.m each complete all as specified and directed.
S&F in repair floor door stoper of aluminium alloy body and tounge anodised with hard drawn steel spring fixed in floor over all length of cover plate 150 mm.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples.complete all as specified and directed.
Supply and fix in repair mild steel helical door spring rat tail rod model including roller plate complete 300 mm long complete all as specified and directed.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 3.00 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed for following :- (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
(e) One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 3.00wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 7 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
(e) One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 8 to 12 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 22 watt LED light fitting engineering extruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Philips BN021LED22S or equivalent in Havells, Crompton
S&F recess mounting LED luminaire of size 2'x2' white 30 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Philips RC360BLED30S or equivalent in Havells, Crompton
S&F recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make Philips / Bajaj / Crompton / Havells.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL25WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35WLED 757SASYBOPC or equivalent iin Bajaj/Philips/CG/ WIPRO
Supply and fixing in repair GI Pipe bend to shape 0.75 mtr (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 6.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed.
Supply & fixing Modular earth plug enclosure (plug and socket ) with MCB, SP 20/25 Amps modular type complete all as specified and directed .Make Havells/Anchor/Legrand .
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down Unsv MCCb/MCB of any specification.
S&F MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 100 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
Repairing of light point (normal/ flameproof), fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type, lamp any type, MCB DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with repair of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected minor accessories by providing sufficient and skilled manpower. Work shall also include to check & removal of current leakages in Bldgs and any urgent nature of work as and when directed. The scope also include cutting of existing Bakelite sheet to accommodate new elect fittings/fixtures like switches, sockets, fan regulators etc. Note :- (a) The rate quoted by the contractor for Each Job is deemed to be included consisting of minimum 03 complaints. (b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete details of Job cards (Working/Off working hours) and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk factor & security pass will be the contractor's end. (g) If the complain will not attend within 24 hours a penalty of Rs. 500/- for per complain will be imposed on Contractor. (h) All supply material shall be deposited by contractor in MES store yard and issued in every Job Card as per requirement. (j) The tradesmen should be available at MES area complaint cell (In MES Complex), after completing their daily Job Cards as well as during off working hours / Night / Sunday / Holiday.
Supply of fan regulator electronic step up type, 80W, SP 230 volt required for attending complaint against item No 104 above complete all as specified and as directed.
Supply only switch piano, flush type 5/6 amp, single pole, one way 240 volt required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 6 Amp required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 16 Amp required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only modular bell push pole 1 way, 1 module, 6 Amp required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only switch socket combination multipurpose 5 pin 5/15 Amps required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only switch socket combination multipurpose 5 pin 5 Amps required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only in repair switch piano, flush type 15/16 amp, single pole, one way 240 volt required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only socket outlet, 3/5 pin, 5/6 amps flush type required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only bell push, flush type 5 amp, single pole, one way 240 volt required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only ceiling rose surface polycarbonate 65X50mm three terminals required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only Call bell ding dong, AC single pole 240 volts required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only lamp LED 9/12 watt, 240 volts required for attending complaint against item No 104 abovecomplete all as specified and directed.
Supply only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed.
S&F in repair ball bearing No. 6200 to 6203 complete all as specified and directed. Make:-SKF/NRB/NBC/TATA
S&F in repair gun metal bush of any description and size to suit existing motor shaft complete all as specified and directed.
S&F in repair capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA
S&F in repair capacitor of capacity 3.15 mfd PVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA
Supply & Fix in repairs wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed.
S&F in replacment old and UNSV ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed. Note : UNSV fans will be deposited to MES Store by Contractor.
Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & repair of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The repair of defective/ nonfunctional parts shall be measured & paid separately as “Supply and fix in repair” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal
All as per item No. 129 above but rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire.
All as per item No. 129 above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire.
All as per item No. 129 above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire.
All as per item No. 129 above but rewinding of motor of pedestal fan of 400 mm sweep with 400 gram winding wire.
All as per item No. 129 above but rewinding of motor of wall mounting fan of 400 mm sweep with 400 gram winding wire.
Supply only in repair complete fan hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Supply only in repair PVC insulated, flexible cable, twin core twisted of size 23/0.0076 with copper conductor in pieces for connecting fans complete all as specified and directed.
Supply only in repair 300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
Supply only in repair 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
Supply and fixing in repair fan blade suiatable for 400mm sweep pedestal fan/ Wall mounting fan complete all as specified and directed.
Supply and fixing in repair metal fan blade suiatable for 450mm sweep exhaust fan complete all as specified and directed.
Supply and fixing in repair fan blade suiatable for 300 mm sweep exhaust fan complete all as specified and directed.
Supply and fixing in repair fan blade suiatable for 230 mm sweep exhaust fan complete all as specified and directed.
Disconnecting, taking down & removing carefully the existing Geyser of any capacity from any position/locations for repairs / fixing the serviceable parts in position, removing & repair of defective/ unserviceable parts, if any, with new parts, reassembling the geyser, hanging/fixing the repaired geysers in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The repair of defective/ nonfunctional parts shall be measured & paid separately as “Supply and fix in repair ” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
S&F in repair heating element of 1.5KW any type as per sample ISI marked complete all as specified and directed.
S&F in repair heating element of 2.0KW any type as per sample ISI marked complete all as specified and directed.
Supply and replace complete Geyser assembly as per exisiting sample including rubber washer and nuts & bolts suitable for water heater capacity 25 Ltrs of any make.
M&L for repairing leakage of inner copper tank of geyser (any make) 25/50 litres capacity by brazing including all necessary denting etc complete all as specified and directed
S&F in repair thermostat suitable for 25 Ltr geyser complete all as specified and directed.
S&F in repair thermostat suitable for 50 Ltr geyser complete all as specified and directed.
S&F in replacment PVC pipes of 450mm long best quality, heavy duty for geyser of 15mm dia with brass connecting nuts/couplers complete all as specified and directed.
S&F in replacment indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repair stop cocks brass CP 15 mm dia suitable for above geyser ISI Marked complete all as specified and directed.
Supply and fixing in repair PVC insulated copper conductor cable 3 core 6 Sq mm 660/1100 volts grade make Kalinga/Finolex/Rallison.
Supply and fixing in repair of plug top 3 pin 15 Amps complete all as specified and directed.
Supply and fixing in repair indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed.
Supply and fixing in repair safety valve to blow of at high rated temperature having latest ISI marked complete all as specified and directed.
Collecting and transporting of desert coolers from MES store yard/user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including repair of unserviceable bolts and nuts with washers, clamps etc.complete and returning back to MES store yard/user locations complete all as specified and directed.(Note :-Parts except nut bolt & washers to be replaced will be measured and paid separately under respective items)
Supply & Fixing in repair fan motor 1/7 HP or any HP complete set with arm and fan blade etc. ,230 volt,50Hz cycles A/C supply of make Summer Cool/CG /Havells/Bajaj complete in all respect.
Supply & Fixing in repair fan blade as per existing sample and size not exc. of 450 mm sweep suitable for fixing with fan motor fixed in desert coolers complete all as specified and directed.
Supply & Fixing in repair capacitor, 4 / 3.15 +/- 5% mfd rating Asian/Univarsal make complete all as specified and directed.
Supply & Fixing deset cooler's fan speed regulator ( three stage ie low, medium & high speed ) switch with Knob 230 V , AC supply complete all as specified and directed.
Supply & Fixing repair plug top, 5 Amps, 230 Volts, 50 Hz, A/C supply make anchor complete all as specified and directed.
Supply & Fixing repair PVC flexible copper conductor cable three core ,1.5 Sq mm complete all as specified and directed.
Supply & Fixing in repair PVC pipe, heavy duty, best quality of 15mm bore/dia complete all as specified and directed.
Supply & Fixing in repair wood wool pad (set of 3) of good quality for desert cooler complete all as specified and directed.
M & L for preparation of steel surface of desert coolers followed by painting with one coat of synthetic enameled paint complete on metallic surface external and internal complete in all respect as directed by Engr-in-Charge. (a) upto 3000 Cum/Hour capacity
All as per item cbove above but above 4000 cum/hour capacity complete all as specified and directed.
S & F in repair side panels made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specified and directed.
S & F in repair bottom tank made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specified and directed.
M & L for repair of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufactorer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 150 Ltrs.
All as per item cbove above but capacity 120 Ltrs complete all as specified and directed.
Supply & Fixing in repair relay assembly for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
Supply & Fixing in repair Over load protector for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
Supply & Fixing in repair Starting capacitor for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
Supply & Fixing in repair running capacitor for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
Supply & Fixing in repair thermostatic switch for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
Supply & Fixing in repair chromium plated push cock, self closing, spring loaded type 15mm dia complete all as specified and directed.
Supply & Fixing in repair drain out PVC pipe, complete with clamp and washers, suitable for fixing in water waste tray (length of pipe 1.50 R.M. approximately) complete all as specified and directed.
Supply & Fixing in repair blower motor as per size & sample in water cooler, commissioning and testing complete all as specified and directed.
Repair to water cooler's body/base by cutting of rusted / deteriorated steel sheets and S & F new MS sheet of 1.6 mm thick for body and 3.16 mm thick for base with necessary spots welding including repair of legs as per existing size and applying red oxide primer on new sheet complete all as specified and directed.( Note:- 1. Finishing cost to be applied shall be measured and paid separately 2. Cost of taking down compressor or any other parts and refixing the same deemed to be included in unit rate quoted by contractor.)
M & L preparation of old painted surface of water coolers and applying one coat of super enameled paint by spray painting gun for water coolers any make and size upto 150Ltrs capacity all as specified and directed.
Repairs to water cooler's water storage tank by running contineous welding (gas welding) for prevention of leakage at places as directed by Engineer - in - Charge.
M & L complete servicing of water cooler by cleanning of coils with caustic soda, removal of rust from sheet metal frame, cleaning of tank and cheacking of water connection and fixing in original position complete in all respects.
M & L for gas charging in water cooler by using refrigerant as per standared specific after proper flushing vacuuming detecting leakge,rectification of leakages commissioning and testing for water cooler.
Repair to refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including replacement of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommended by manufacturer Make Kelvinator /Godrej /LG of 308/325 Ltrs capacity.
Supply and fixing in repair of box type relay for any make and capacity upto 310 ltrs refrigerator complete all as specified and directed.
Supply and fixing in repair thermostatic switch for any make and capacity upto 310 ltrs refrigerator complete all as specified and directed.
Supply & fixing in repair of wiring kit suitable for any make refrigerator of 165 to 310 Ltr capacity complete all as specified and directed.
Repair to Deep Freezer complete by cleaning of system properly with CTC. Charging refrigerant including replacement of unserviceable sealed unit (Compressor) of deep freezer with new sealed unit, recommended by manufacturer Make Voltas of 320 Ltrs capacity.
Supply & Fixing in repair blower motor as per size & sample in deep freezer, commissioning and testing complete in all respect.
Repair to window / Split type Air conditioner by replacement of unserviceable sealed unit i.e.compressor (rotery or hermetic) ,cleaning of system properly with CTC and charging the refrigerant (including cost of refrigerant ) recommended by manufacturer of AC including commissioning and testing complete all as specified and directed by Engr - in - Charge at site for 2 TR Window / Split type AC.
All as per item cbove but 1.5 TR Window/Split for Air Conditioning.
S & F in repair condenser coil as per sample for 1.5 Ton A.C. Note : Charging of refrigerant including cost of refrigerant will be measured and paid separately under respective item complete all as specified and directed.
S & F in repair relay suitable for split type AC / window type AC upto capacity of 2TR complete all as specified and directed.
S & F in repair over load protector suitable for split type AC of 1.5 Ton complete all as specified and directed.
S & F in repair for air conditioners, capacitor 36 / 45 / 50 +6 mfd +/- 5% ,440 V AC complete all as specified and directed.
S & F in repair thermostatic switch suitable for 1.5 / 2 ton AC make Renutrol complete all as specified and directed.
S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed.
S & F in repalcement fan motor with blade for Window type AC of capacity 1.5 Ton of make LG/Voltas complete all as specified and directed.
M & L for gas charging in split type AC unit 1.5 TR capacity using refrigerant as per standard practice after flushing, vacuuming including detecting leakage, rectification leakage, commissioning and testing complete in all respect.
All as per item cbove but for split type AC unit of 2 TR capacity complete all as specified and directed.
All as per item cbove but for window type AC unit of capacity 1.5 TR capacity complete all as specified and directed.
S & F in repair power PCB as per sample suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified.
S & F in repair copper connection pipe with union at both ends and with insulation, between FCU unit and indoor unit of length twelve feet for 1.5/2 TR Split type AC, making connection & testing complete all as specified.
S & F in repair insulation on copper tubing suitable for split type AC complete all as specified and directed.
S & F in repair drain hose pipe suitable for 1.5 / 2 TR split type AC complete all as specified and directed.
S & F in repair air filter as per existing size suitable indoor unit of 1.5 TR split type AC complete all as specified and directed.
S & F in repair auto chang over unit with inbuilt timmer (programmable for operation between 01 hour to 24 hrs) having facility to operate alternatively two AC upto capacity 2.0 TR , commissioning and testing complete all as specified.
M & L for complete servicing of Air conditioner window/split type including cleaning of colling coil and condenser by caustic soda solution including removal of dust by using blower/brush to external fins and from beneath assets, cleaning of base tray properly including oil to fan & condenser motor, tightening of all electrical connections with proper alignment including fitments in their locations and repairs of suction & discharge tubes complete in all respects. (Note :-Filling of refrigerant if required or parts to be replaced will be measured and paid separately under respective items)
Repair of voltage stabilizer of capacity 5 KVA/4KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer and IC circuit as required and making functional and testing complete all as specified and directed .
Repair of voltage stabilizer of capacity 2 KVA/1 KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer & IC circuit as required and testing complete all as specified and directed .
Maint repair of reverse osmosis with UV water purifier system five stage having storage capacity 10 Ltrs and flow capacity 15 Ltrs per hour by cleaning supply & fix in repair required parts such as connecting pipe, buster pump, filter element (pre carbon/ UFmembrane/RO inline carbon filter) adapter,UV lamp ,SMPS etc. and making RO complete serviceable & testing complete all as specified and directed for RO of make KENT / Aquafine / Aquasoft.
M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth wire 4Sq mm as earthing leads by means of bolts, nuts, check nuts and washers properly jointed as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as specified and directed.
Taking down the existing defective LT UG cable from trenches / pipes / pole for fault finding / replacement, all as specified and directed of any size between 10 Sq mm to 50 Sq mm 3.5 core/4 Core. ( Note-Excavation and earth work will be measured and paid seperately under relevant item. )
All as per item No. 217 above but size 120 Sqmm 3.5 core to 400 Sq mm 3.5 core.
Supply and laying ,jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 4 core complete all as specified and directed.
All as per item above but size 16 sq mm 4 core complete all as specified and directed.
All as per item above but size 25 sq mm 4 core complete all as specified and directed.
All as per item above but size 35 sq mm 3.5 core complete all as specified and directed.
All as per item above but size 50 sq mm 3.5 core complete all as specified and directed.
All as per item above but size 120 Sq mm 3.5 core complete all as specified and directed.
All as per item above but size 240 Sq mm 3.5 core complete all as specified and directed.
All as per item above but size 400 Sq mm 3.5 core complete all as specified and directed.
Excavation in trenches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces for laying of cable complete all as specified and directed.
Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and directed.
Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal surplus soil at a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed.
Labour for boring, holes for inserting of 50/80 mm bore GI pope under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected.
M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 630 Amps with breaking capacity 50 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 400 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 250 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 200 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,63 Amps with breaking capacity 16 KA fixed type all as specified and directed.
M&L for replacement of phase indication light LED type for LT panels in three colours (R,Y,B) complete all as specified and dirtected.
PANDEY TRADERS (BID ID -3081664)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .