| 1 | 1₹11.3 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | ₹11.3 L Quoted ₹12.2 L | 1 | Accepted-AOC L1 |
| 2 | 2₹12.9 L+₹70,925 (5.82%)Rejected-Finance KERNI MARKET COURT ROAD UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹12.9 L+₹70,925 (5.82%) | 2 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 3 | 3₹13.7 L+₹1.5 L (12.5%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹13.7 L+₹1.5 L (12.5%) | 3 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 4 | 4₹14.2 L+₹2.0 L (16.2%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹14.2 L+₹2.0 L (16.2%) | 4 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 5 | 5₹15.5 L+₹3.3 L (26.7%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹15.5 L+₹3.3 L (26.7%) | 5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
3 Feb 2022, 6:00 pmClosed
GE AF Udhampur
AIR FORCE STATION UDHAMPUR
REPAIRS TO INTERNAL WIRING AND REPLACEMENT OF LIGHT FITTINGS AND CERTAIN MISCELLANEOUS INTERNAL ELECTRIFICATION WORKS AT AIR FORCE STATION NATHATOP UNDER GE (AF) UDHAMPUR
2021_MES_488840_2
GE/AFU-43/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
AF STATION NATHATOP
Please refers tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹30,000
Yes
25 Apr 2022
12 Jan 2022
5 Feb 2022
12 Jan 2022
3 Feb 2022
19 Jan 2022
13 Jan 2022 - 18 Jan 2022
Amount
M&L in replacement point wiring using approved colour coding as per IS for one light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring using approved colour coding as per IS for one light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid surface conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring using approved colour coding as per IS for one light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, casing caping, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 6 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 6 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 6 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, surface conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 6 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid casing caping, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 16 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 16 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid surface caping conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
M&L in replacement point wiring for one 16 Amp socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through and including PVC, rigid casing caping conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth duly complete all as specified and as directed including cutting chases to wall and making good the dfisturbefd surfaces to match with the existing specifications complete all as specified. Note : Switches, sockets, outlets and regulators will be measured and paid for separately.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as speciifed and as directed
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6 Amp modular type, 2 modules complete all as specified and as directed.
Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
Modular type blanking plate, 2 module, complete all as specified and directed .
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Electric bell, AC 230 volt, single pole, Ding Dong type complete all as specified and as directed.
Modular bell push, single pole one way, 1 module, 6 Amp complete all as specified and as directed.
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 10.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC casing caping and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 10.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 10.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose .
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC rigid surface conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 6.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC casing caping and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 6.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose
M&L in replacement of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC concealed and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 6.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose
M&L in replacement of Vertical three phase distribution board, TPN, 4 way 440 volts having IP-54 protection, double door with provision for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories therein & disposing from site complete all as specified and as directed.Make:CAT PART NO:507680 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
M&L in replacement of MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:507682 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
M&L in replacement of MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
M&L in replacement of MCB TPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
M&L in replacement MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
M&L in replacement MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
M&L in replacement MCB single pole, 6-32 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
M&L in replacement MCB SP 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
S&F in repairs indoor decorative extruded aluminium anodised housing/CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink/aluminium housing for excellent heat dissipation; 4 feet (approx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified. MAKE : Wipro or equivalent to Havells/Philips/ Crompton Note :- The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F in repairs LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
M&L in replacement of cutting of all copper coils and taking out burnt/ damaged wire from exhaust fan motor of any make and M&L for rewinding of exhaust fans of 450mm sweep with super enamelled copper winding wire of same size, guage and weight including varnishing and insulating complete all as specified and directed
Description all as per Srl item No. 37 here-in-before but 300 mm sweep.
S&F in repairs fluorescent tube light fitting. 1x22W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and directed by Engr-in-charge.
S&F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V,complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 25 sqmm ,3.5 core laid on walls/floors or in air with saddles and gutties, complete all as specified and directed by Engr-in-Charge
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 35 sqmm ,3.5 core laid on walls/floors or in air with saddles and gutties, complete all as specified and directed by Engr-in-Charge
S&F PVC Exhaust fan of size 300 mm sweep ,240 V including grouting in wall with hold fastner ,wooden frame as required at site,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.MAKE:HAVELLS/BAJAJ/CROMPTON
S&F PVC Exhaust fan of size 450 mm sweep ,240 V including grouting in wall with hold fastner ,wooden frame as required at site,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.MAKE:HAVELLS/BAJAJ/CROMPTON
Supply and fix in replacement of battery bank of capacity 12V 26AH for UPS operations complete all as specified and directed by Engineer-in-Charge
S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing but 20x3mm copper strip
Disconnecting and taking up or down existing unserviceable flameproof point wiring/ rotary switch/ switches/ sockets of any description, any size and in any position from existing conduits and making good the disturbed surfaces to match the existing surfaces all as specified and directed
M&L explosion proof point wiring for one light/ bell/ buzzer with 1.5 sqmm 1100 volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ ceiling with proper fixing arrangement including one number continuous run of 1.5 sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/ fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified
M&L explosion proof point wiring for one 3 pin 16 Amps socket outlet independent with 2.5 sqmm 1100 volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ ceiling with proper fixing arrangement including one number continuous run of 1.5 sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/ fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified
M&L Explosion proof rotary switch single pole ON and OFF with cable termination box of 10 Amps rating 230 Volts Class E Ex II C suitable for class I Zone I, all as specified
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 8 way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for and including following accessories:- (i) MCB SPN 32 Amps with rupturing capacity 16 KA - 06 Nos (ii) MCB SP 06 Amps with rupturing capacity 10 KA - 04 Nos
M&L Flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+ earth all as specified
M&L Flameproof control gear box epoxy finish LM6 aluminium alloy housing including all accessories prewired with polycarbonate cover polyster resin enclosre and central locking system, all as specified and including taking down old.
Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF format will be deducted offline during acceptance of Tender
kerni electricals
RANBIR ENTERPRISES
slathia construction works
MAHAJAN TRADING CO
KARAN TRADERS
R K BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .