Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
26 Nov 2026, 6:00 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE AF LEH
GE AF LEH, NEAR POLICE HQ, LADAKH PIN 194101
PROVN OF CERTAIN EM MINOR WORKS AT CERTAIN LOCATION UNDER GE AF LEH
2026_MES_786720_3
GE(AF)Leh/T-44/2026-27
Open Tender
Electrical and Maintenance Works
Works
180 days
Leh
As per NIT
8 documents required · 8 mandatory
₹500
GE AF LEH
₹40,000
Yes
11 Nov 2026
11 Nov 2026
28 Nov 2026
11 Nov 2026
26 Nov 2026
19 Nov 2026
11 Nov 2026 - 18 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches n.exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes. etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete all as speified and directed by Engineer-in Charge | 68 | Cum | - | - |
| 2 | Returning, filling in Any type of soil, incl spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as speified and directed by Engineer-in Charge | 48 | Cum | - | - |
| 3 | Removing excavated material (soil) exc 1.50 km and depositing where directed at a level n exc 5.00 km above the starting point, complete all as speified and directed by Engineer-in Charge | 20 | Cum | - | - |
| 4 | M&L of Fire alarm system control wiring sheathed multi stranded armoured copper conductor FRLS-H cable of size 1.5 Sqmm 2 core with shielded 1100 Volts drawn in and including MS conduit (Medium grade ISI marked) of dia not less than 20mm with standard accessories complete all as specified and directed .
Note: (a) Two run of copper cable with MS conduit will be measured as one single length.
(b) Flexible steel conduit shall be used at the edge/bends of the steel conduit.
(c) The Cost of necessary steel Tee, bends, junction boxes saddle with clamps is deemed to be included in the quoted rate. | 640 | RM | - | - |
| 5 | Supply and fix addressable type Manual Call point enclosed in the Press Type compatible with main fire alarm control board microprocessor based resettable and LED blinking alarm facility complete all as specified and directed.
Note:- (a) The call points shall be installed minimum 1.4m above the floor level.
(b) The MCP shall be interlinked with the Fire Control panel. (c) The MCP shall be fixed in the path of escape and essentially near the exit point. | 16 | Each | - | - |
| 6 | Supply install testing and testing of wall mounted electronic sounder cum strobe/Siren electronic type with sound level 65 DB to 120 DB measured 1.5 mtr with sound output variation of +5 DB and 1000 mtr range ,EN 54 on 24V DC made of FR ABS Plastic all as specified and as directed. | 16 | Each | - | - |
| 7 | Supply install test and commissioning of conventional type response indicator metallic type with dual red colour LED indicator, Flus/ ceiling mounted, operating on 12 V DC complete all as specified and as directed. | 18 | Each | - | - |
| 8 | Supply fixing of conventional smoke detactor sensor with alarm including wiring connection with two core copper cable with fire control panel complete all as specified. | 50 | Each | - | - |
| 9 | Supply, installing , testing and commissioning of Voltage Stabiliser copper wound for automatic operation , single phase, 50 Hz AC Supply naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 270 V with output voltage stabilised at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete. Make : V-guard/ Microtec/Bluebird | 3 | Each | - | - |
| 10 | Supply, installation & testing of main fire control panel with new microprocessor based 08 zone fire control panel for fire protection system consisting of battery backup with build in charger complete digital type including making wiring connections of all zones and testing of fire alarm panel zone wise as per the satisfaction of Engineer-in-Charge.(Make: Agni / Daksha / SystemSensor or equivalent). Note :- The quoted rates also includes the rates for testing and commissioning after installation of Fire Alarm Panel. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_895491.xls
BOQ • 0.38 MB
tenderEM44.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .