Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical Not Meeting eligibility criteria |
Tender Value
₹2.6 L
EMD Value
₹5,259
Closing Date
6 Feb 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM Electrical AAI Calicutt Airport
O/o AGM Electrical AAI Calicutt Airport
SITC of Fire alarm and Painting of power supply installations at Agatti Airport
2022_AAI_139900_1
AAI/AG/ENG(E)/FIRE/NIT-6/22-23
Open Tender
Electrical Works
Item Rate
120 days
Agatti Lakshadweep
as per NIT
10 documents required · 10 mandatory
₹1,120
₹5,259
15 Nov 2023
30 Dec 2022
7 Feb 2023
31 Dec 2022
6 Feb 2023
31 Dec 2022
31 Dec 2022 - 9 Jan 2023
Amount
SH I :- Painting of Power Supply Installations.
Spray Painting of following Power Transformer with two coats of synthetic enamel paint of approved shade, quality and brand after cleaning the surface including scrapping, cleaning & providing putty/ primer wherever required on the surface before painting, marking of oil level, inscription of rating & feeder details after painting by sticker/ painting of approved colour as required and as per instructions of Engineer-In-Charge.
250 KVA Oil type Transformer (Approx. area per Job = 19 Sq.Mtrs)
Spray Painting of HT & LT Panels at following Locations with two coats of synthetic enamel paint of approved shade, quality and brand after cleaning the surface including scrapping, cleaning and providing putty / Primer (only minor area) wherever required on the surface of panel, inscription of feeder details after painting by sticker/ painting of approved colour including providing masking by suitable means for all meter, relays & indication lamps before painting and cleaning of meters, relays & indication lamps after painting for removal of paint, if any as required and as per instructions of Engineer-In-Charge.
Sub Station
11 KV 3 panels (Approx. area per Job =17.91 Sq.Mtrs)
LT Essential Panel (Approx. area per Job = 15.01Sq.Mtrs)
LT Non essential Panel (Approx. area per Job = 19.58 Sq.Mtrs)
Capacitor panel - 30 KVAR (Approx. area per Job = 2.12 Sq.Mtrs)
LT AMF Panel (Approx. area per Job = 6.58 Sq.Mtrs)
Technical Building
Switch room essential panel (Approx. area per Job = 7.66 Sq.Mtrs)
Switch room non essential panel (Approx. area per Job = 7.66 Sq.Mtrs)
Near fire station panel (Approx. area per Job = 2.60 Sq.Mtrs)
Essential DB First Floor ATC (Approx. area per Job = 0.51 Sq.Mtrs)
Remote control desk In ATC Tower (Approx. area per Job = 3.07 Sq.Mtrs)
Operational Area
Starter panel near fire well (Approx. area per Job = 2.60 Sq.Mtrs)
Runway LT feeder Outdoor type panel- 1 No (Approx. area per Job = 2.76 Sq.Mtrs)
Runway LT feeder pillar Outdoor type Neptune panel.- 4 No.s (Approx. area per Job = 3.52 Sq.Mtrs)
AAI Residential Colony
Starter panel (Approx. area per Job = 2.60 Sq.Mtrs)
Terminal building
Arrival hall (Approx. area per Job = 1.86 Sq.Mtrs)
CCR remote connector box(Approx. area per Job = 0.66 Sq.Mtrs)
Runway 1,2, APAPI 22 and APAPI 04 (Approx. area per Job = 5.17 Sq.Mtrs)
Taxiway CCR (Approx. area per Job = 3.68 Sq.Mtrs)
Various locations as required.
Painting of Chequered Plate cover of cable trench, MS angle / channel supports / LT Panel of various equipments with two coats of synthetic enamel paint of approved shade, quality and brand after cleaning the surface including scrapping, cleaning and providing putty/ primer wherever required on the surface before painting as required and as per instructions of Engineer-In-Charge.
Power House
Repair of brick works of existing earth pits and replacing CI/MS cover plate, Funnel etc as required.
Supply, replacement, Testing and commissioning of Four pole On load change over switch of 250 Amps rating with MS Enclosure, in the existing wall, including providing Handle, providing LED Display for inputs and Output, suitable Bus Links for both at Input & Output Side, grouting, earthing etc., as required.
SH-II: Fire Fighting and Fire alaram associated works
Supply, installation, testing and commissioning of UL/ LPCB/ FM/ EN54 Listed Analogue Addressable type Optical Smoke Detector complete with all accessories like base, base box, etc. (with flash scan ) to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of Listed Response Indicators outside the rooms for getting fire indications of detectors installed above false ceiling area / inside the rooms interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL/ LPCB/FM/ EN54 Listed addressable loop Isolators to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL Listed Addressable type Manual Call Point (break glass type/pull type) complete with Input Module, push button, enclosed in box with provision for cable or conduit coupling etc.complete in all respects as required by the standard specifications. The unit to be painted fire red outside, white inside.
Providing, installing, testing and commissioning of UL/ LPCB/FM/ EN54 listed Hooter cum Strobe with Base plate complete in all respects as required by the standard specifications.
Providing, installing, testing and commissioning of UL/ LPCB/FM/ EN54 listed control module for Hooter cum Strobe with Base plate complete in all respects as required by the standard specifications.
Supply of 2CX1.5 Sq.mm insulated FRLS armoured copper cable for control cabling of Fire detection and alarm devices as required by the standard specifications.
laying/fixing, termination etc. of following size insulated FRLS armoured copper cable in surface/ recess / above false ceiling /concealed space/wall/pipe/trench concealed, etc. for control cabling of Fire detection and alarm devices and interconnecting them by 2 x 1.5 sq mm etc complete in all respects as required by the standard specifications.
Trans installation of intelligent addressable Fire alram panel from existing room to new fire control room including dismantling, shifting, fixing of panel, terminaion of cables, configuring with new devices devices etc., complete as required and as per direction of Engineer - In - Charge.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .