Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹17.4 L+₹2.1 L (13.4%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹18.1 L+₹2.7 L (17.6%)Rejected-Finance 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹18.9 L+₹3.5 L (22.9%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | Rejected-Technical 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | - | Rejected-Technical NOT ENLISTED IN ELIGIBLE CATEGORY |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF GWALIOR
CWE AF GWALIOR
CERTAIN REPAIR MAINT WORKS IN 33 KV MRS OTHER HT INSTALLATION AT AF STATION GWALIOR
2022_MES_526074_1
85029/E8
Open Tender
Civil Works
Item Rate
365 days
GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (AF) ADM Area Gwalior
₹40,000
Yes
22 Jul 2022
24 May 2022
27 Jun 2022
24 May 2022
21 Jun 2022
7 Jun 2022
60 days
Amount
Disconnecting, testing, cleaning and servicing/ overhauling of following items and taking out and removing unserviceable/ defective parts including greasing, oiling of the parts, etc. and replacement of unserviceable parts with new one, reassembling the items after overhauling/ servicing and its testing complete all as specified and directed by Engineer-in-Charge.
Oil cooled Current Transformers 33KV outdoor type (Set of three)
Oil cooled Potential Transformers 33kv outdoor type (Set of three)
Control panel and breakers 33 KV
Note for Sl item No. 1.00 to 1.03 :- (i) Servicing and testing will be done by authorised rep of manufacturer. (ii) The quoted rates by the bidder deemed to be included for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new spare parts shall be measured and paid for separately under respective item of BOQ(Sch 'A’) as "supply only". (iii) The Repair / servicing / Overhauling shall be Carried out by Authorised Rep of manufacturer.
Supply only following spare parts for 33 KV VCB as under:- Note : Fixing & testing element of following items are deemed to be included under item No 1.01 to 1.03 of BOQ.
(a) Micro switch
(b) Motor cut of limit switch
(c) LED Indicating lamps R,Y,B,W,G,A 30VAC/110VAC/230VAC
(d) Closing coil 110 VDC
(e) Tripping coil 110 VDC
(f) Segment gear Assembly (Full Teeth-Big )
(g) Tripping Half shaft
(h) Trip Catch with linkage assembly
(j) Spring charging motor assembly 230 VAC
(k) Motor Gear Box Assembly.
(l) Hold on Catch assembly with spring
(m) Closing Half shaft
(n) Auxiliary switch assembly
(o) Ratchet wheel with key & Set of pawls with pin
Disconnecting and taking down old unserviceable control cable, any size & any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 4 core copper conductor armoured cable connecting the cable in position properly by providing suitable new copper lugs GI bolts, nuts & washers etc complete all as specified and directed.
Disconnecting and taking down old unserviceable control cable any size & any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 16 core copper conductor armoured cable connecting the cable in positioning properly by providing suitable new copper lugs GI bolts,nuts & washers etc. complete all as specified and directed.
Disconnecting and taking down the unserviceable/damaged/non operational existing lightening arrestor of 33KV Switching yard and supply , fixing & testing and commissioning of new lightening arrestor 33KV, 10KA suitable for 33KV and maximum voltage of 36KV for (MRS) with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work and all as specified and directed.
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 400 Amps of 33 KV and supply and fix new air break switch gang operated Triple pole mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch complete all as specified and directed
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 200 Amps of 11 KV and supply and fix new air break switch gang operated Triple pole with dropout fuse set insulators mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch complete all as specified and directed.
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 400 Amps of 11 KV and supply and fix new air break switch gang operated Triple pole with dropout fuse set insulators mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch complete all as specified and directed.
Taking down unserviceable Drop out fuse set and supply and fix drop out fuse set outdoor type ratio 400 Amps of 33 KV mounted on insulator and steel frame complete all as specified and directed.
Disconnecting and taking out existing unserviceable Potential transformer (PT) of any description & in any position and supply, installation, commissioning and testing of 33 KV single phase outdoor oil cooled potential transformer as per IS 3156 all as specified and directed.
item no. 10 contdd... MANDATORY PARTICULARS OF 33 KV O/D POTENTIAL TRANSFORMER (a) Type :-Dead tank (b) Rated voltage :-33 KV, Highest voltage :-36 KV and Frequency :-50 HZ (c) Basic Insulation Level :- Primary: 36 KV/70 KV/170 KV(p) and Secondary : 3KV for 1 minute (d) Class of Insulation :- Class A (e) Creepage distance :-900 mm (minimum) (f) Ratio :-33000/√3 - 110/√3 volt (g) Class of accuracy :-Core - I : 0.5, Core - II :3P (h) Burden :-Core - I : 100VA, Core - II :100VA (j) Voltage factor :-1.2 Continuous, 1.5 times for 30 Sec. (k) Core identification :- Core - I : Metering, Core - II : Protection (l) Primary terminal connector :- Rigid type suitable for PT Stud to Dog ACSR. (m) Fixing hole dimension & Painting :-330 mm both X & Y direction and Paint shed : Battleship gray as per IS 5 Paint thickness :60 micron ( minimum) and Secondary terminal box : IP 55 (n) Suitability :-Should be suitable for upright mounting on steel structure in outdoor switch yard with matching to MPSEB' s Standard base structure.
Inspection, dismantling and taking out of following old unserveciable parts OLTC 5 MVA Transformer, Repair and replacement with new parts:-
(a) Servicing charges of our serving engg. For attending of CTR make, Tap changer Type-EO16,
(b) Fixed Contacts
(c) Main Moving Contacts
(d) RESISTOR Moving Contacts
(e) Transistor Resistor.
(f) OLTC Top cover Gasket
(g) Anti Scrubbing Paste-100gm.
(h) Tap changer DSS switch.
(j) TPI Tap Changer counter.
(k) CRC Sparry
Testing of OLTC Panel of 5 MVA Transformer complete and repairing the same by replacing the faulty parts for smooth functioning of the panel complete all as specified and directed.
Surface excavation around the poles/feeder piller boxes/ sub stations not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/hard dense soil including cleaning the bushes and vegetation and levelling and removal of surplus soil out of MOD land complete all as specified and directed.
M & Laying for the hardcore broken stone/ boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick to a true surface at the places as specified and directed by Engineer-in-Charge.
Disconnecting & taking down old unserviceable GI Pipe of any description and supply and fixing/laying pipe GI medium grade 15 mm bore fixed on wall or laid under floor with all accessories complete all as specified and directed.
Disconnecting & taking down old unserviceable GI Pipe of any description and supply and fixing/laying pipe GI medium grade 25mm bore fixed on wall or laid under floor with all accessories complete all as specified and directed.
Disconnecting and taking out existing unserviceable Current Transformer (CT) of any description and from any position and supply, installation, testing and commissioning of cast resin type 33 KV, single phase, out door oil cooled CT of ratio 200-100/5-5 Amp having protection core class 1.0 / 5P10, burden 15 VA and installation level 70 KV/170 KV as per IS 2075 all as specified and directed.
Disconnecting and taking down old unserviceable existing battery bank of any description and in any position, supplying, fixing, commissioning and testing new battery charging unit of 28 Volts 180 AH DC out let input 230 volts AC including 2 Nos of battery each of 12 volts 180 AH sealed maintenance free Battery bank shall be enclosed in suitable size sheet metal enclosure with and including volt meter & Ammeter of suitable range & variable output type charging transformer including painting with two coats of synthetic enameled paint over a coat of red oxide primer on all steel surfaces complete all as specified and directed by Engineer - in- charge. Note : Existing battery bank shall be deposited by contractor in store yard and taken on charge.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. complete all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box , having protection class IP-66 and of overall size 300mm x 250mm x 120mm having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 8 Way cable connector and 1 No. 6-32 Amps SP MCB including taking down of existing junction box complete all as specified and directed. Make :Sintex/Havells/Hansel
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32mm x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt around earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing complete all as specified & directed by Engineer-in-Charge. Note: (i) Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders,aggregates,gravel etc. (iv) The rate quoted by the bidders shall be also be deemed to include :-(a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
Disconnecting earthing strip of any type and testing of earth results and writing the result on earth pit cover with white paint on black back ground all as specified and directed by Engineer-in-Charge including reconnection after testing complete all as specified & directed Note:- All required T&P, material and labour for testing and writing will be provided by the bidder and the same shall be deemed to be included in the unit rates quoted by the contractor.
Supply, filling and for topping up the CTs/PTs with new transformer oil duly filtered with filtration plant. Note:- (a) The transformer oil shall be type EHV confirming to IS 3357 of 1983 (b) Mineral oil grade 'B' shall be used. (c) The transformer oil shall have a high dielectric strength not less than 40KV (d) The empty barrel shall be deposited in MES store yard
DUBEY TRADERS & eNGINEERS
M/S SANTOSH CONSTRUCTION CO
M/S DARSHAN ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .