| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | ₹1.8 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S NEW LIFE ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) | ||||
| 1.01 | 6 way (4 + 18), Double door | 1 | No. | 3,600 ₹3,600 Lowest |
| 2.00Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) | ||||
| 2.01 | 12 way (MCCB + 36), Double door | 7 | Nos. | 11,500 ₹80,500 Lowest |
| 3.00Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | ||||
| 3.01 | Single pole | 11 | Nos. | 195 ₹2,145 Lowest |
| 3.02 | Triple pole | 13 | Nos. | 800 ₹10,400 Lowest |
| 4.00 | Supplying and fixing 63 A TP rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 13 | Nos. | 1,500 ₹19,500 Lowest |
| 5.00Supplying and fixing following rating, four pole, 415 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. | ||||
| 5.01 | 40A | 1 | No. | 1,100 ₹1,100 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
11 Feb 2022, 4:00 pmClosed
Er KS Nathyal
Superintending Engineer PWD RandB Jammu Kathua Circle Jammu
please refer BOQ
2022_PWDJK_158996_1
Fresh e-NIT No.EDJ/229 of 2021-22 Dated 01-02-2022
Open Tender
Electrical Works
Item Rate
60 days
GMC Kathua
please refer to NIT
3 documents required · 3 mandatory
₹5,000
Yes
Superintending Engineer PWD RandB Jammu Kathua Cir
₹3.6 L
Yes
19 Feb 2022
1 Feb 2022
12 Feb 2022
2 Feb 2022
11 Feb 2022
2 Feb 2022
Amount
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
6 way (4 + 18), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.)
12 way (MCCB + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing 63 A TP rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 30kA, FP MCCB
Supply, fixing, testing and commissioning of single spike air terminals of 10 mm dia.of 1Meter long as required and as per site conditions. the air terminal shall be manufactured with aluminium. The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such a way that conductor contact area shall not be less than 40mm on all side of the conductor as per IS/IEC 62305.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.
Supply, fixing, testing and commissioning of Lightning counter indicating date and time of last record In-addition having to see previous history of surges etc complete as required to meet requirements to IS/IEC 62561-1 etc. complete as required.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 32 mm X 6 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip in 80 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 50 mm x 5 mm copper striip on surface or ini recess for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
600 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
600 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
600 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supply of following sizes of Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments.
4 x 10 sq.mm.
4 x 25 sq.mm.
3.5 x 35 sq.mm.
3.5 x 50 sq.mm.
3.5 x 70 sq.mm.
3.5 x 95 sq.mm.
3.5 x 120 sq.mm.
3.5 x 150 sq.mm.
3.5 x 185 sq.mm.
3.5 x 300 sq.mm.
Supply of following sizes of Power Cables multi stranded Copper conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments.
10 sq.mm. 2 core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (38mm)
3½ X 120 sq. mm (45 mm)
3½ X 150 sq. mm (50 mm)
3½ X 185 sq. mm (57mm)
3½ X 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
2C X 10 sq. mm (19mm)
4C X 4 sq. mm (25mm)
4C X 6 sq. mm (25mm)
4C X 10 sq. mm (25mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of Recess mounted LED 2'x2' luminaire delivering an initial system lumen of 3600 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA, Rim: Engneering plastic / CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply, Installation, testing and commissioning of 11 kV DP structure as per CEI & MSEB norms & comprising of the following, but not limited to it for completion of works RSJ pole of 9.15 mt length of size 175 x 90 mm complete with suitable M.S. base plate welded at bottombase plate - 2 Nos. MS Channel of size 100 x 50 mm, length 4 mts (approx) 11 KV AB switch - 1 set 11 KV Horn Gap fuse Unit - 1 set 11 KV Lightning Arrestor 11 KV Disc insulator 11 KV Pin insulator 6 SWG copper wire for jumpering Supply and erection of Stay set complete with necessary foundation, excavation and refilling of earth etc. as required. Concrete foundation for RSJ poles burrioed upto a depth of 1830 mm in ground in a pit of size 450X450 mm in CC 1:3:6 along with 200 mm copping above ground inclusive of earth work. Necessary Nut, Bolts, clamps, operating handle for AB switch, clamping welding etc. complete as required. Painting the RSJ poles complete with two coat of Red Oxide and two coats of GI enamel paints complete as required. Transportation of all materials and accessories at site Complete erection, testing and commissioning.
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to Sub-Station at various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of the following bolted fabricated in compartmentalized (Form-3B construction) conform to IS: 8623/1993, Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply, are housed in design from CRCA sheet steel of 2mm thick for frame work and door covers, 3mm thick for gland plate, i/c cleaning & finishing complete, having extensible type bus bars of high conductivity, SMC bus bar supports, the maunfacturer shall be certified from CPRI for short circuit withstand capacity of min. 70kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common earth bar as specified below at the rear with 2 Nos. earth stud each side, bus bars and control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium duly sleeved with Helogen Free heat shrink coloured Insulated tube confirming to IEC 60684-3-247 Standard. The powder coating (70-80micron as per IS:13871 for indoor and 100-120 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. General Notes for site visit report for Panels/ Rising Main before submitting GA. The Manufacturer must visit the site before submitting GA drawings and submit a report consisting following: Possible height for Panel. Possible width for Panel Back access will be possible or not. Cable entry will be from top or bottom. If entry from bottom whether MS. Stand is required or not. If the panel is wall mounted whether the wall is available or not. Path for movement of transportation of panel is possible or not i.e length, width etc. and the transportation sections shall be designed accordingly.
Sufficient space available at front & back after door opening. Sufficient height available above panel for cable drop. Actual floor to floor height for rising mains. Also, refer to General Notes and Specifications for Panels/ Boards. All Panels shall be considered Indoor type unless specified. The degree of protection for all indoor type panels shall be of IP:52 ("5" Indicates Dust Protected limited ingress of dust permitted. Will not interefere with operation of the equipment and "2" indicates protection against vertically falling drops of water with enclosure tilted upto 15 deg from vertical.) and all outdoor type panels shall be of IP:55 ("5" indicates Dust Protected limited ingress of dust permitted. Will not interefere with operation of the equipment and "5" indicates protection against jets of water) Provide thermostat controlled panel mounted heavy duty exhaust fan in each Vertical for all Main L.T Panel and Capacitor Panels. For all other panels a proper ventilation louvers shall be provided. Fully automtic control thermotate with strip heater shall be provide in each Bus-Bar alley and relay compartments to control the humidity
P-P=32mm, P-N=32mm,P-E=26mm and N-E=26mm Panel Power and control Wiring all FRLS PVC insulated min. conductor to be used as follows: AC voltage circuit-1.5 sqmm Red,Yellow,Blue &Black Current circuit-1.5 sqmm Red,Yellow,Blue &Black AC Control circuit-1.5 sqmm White for Phase & Black for Neutral DC Control circuit-2.5 sqmm Grey Power circuit- Red,Yellow,Blue for Phase &Black for Neutral Phase-Neutral Terminology: TP: Three Phase TPN: Three Phase and Neutral (Neutral shall be Half of Phase Capacity) TP+2N: Three Phase and Neutral (Neutral shall be 200% of Phase Capacity) 4P: Three Phase and Neutral (Neutral shall be 100% of Phase Capacity) Labelling- Computerised Laminated Aluminium Name Plate with White letters on Blue/Black Background For Each Feeder and Panel Itself.
The treatment of Panel Shall be Fully automatic 9-tank process for metal treatment which consists of Solvent/ Alkaline Degreasing, Water Rinsing, De- Rusting, Water Rinsing, Passivation, Phosphating, Water Rinsing, Activation and Drying A separate compartment for Minimum 20% spare space of Panel shall be provided for outgoings in future and busbars shall be drilled accordingly. During inspection of the panel, the manufacturer of major products shall be available at factory to validitate that the used products are original. Certification shall be given by OEM's on their company letter head. All incoming/outgoing MCB shall be mounted on din channel inside closed chambers shall have Acrylic sheet infront and front door should be a glass for see thru. In Meter boards all copper flexible wiring shall be provied with suitable copper lugs and ferruling at both ends and earthing shall be provided for individual meter with 2.5sqmm green insulated wire.
Earthing of rising main mounted meter boards shall be connected with rising main earth bar by 2Nos. 20x3 mm GI strips. Direct magnetic/ screwed mounting panel light of minimum 100 lux at terminal point shall be provided in each relay, instrument and cable alley compartment and in all back accessible compartments each with door toggle switch. Refer Finder 7L Series Main LT Panel (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry.
INCOMER FROM TRANSFORMER-I & II (1000 kVA) 2 No. 1600Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, the ACBs must be provided with terminal adaptors (Hr Vr), ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides.(Where interlocking is required between incomers)
INCOMER FROM DG SET-I (500 kVA) 1 Nos. 800Amps TP EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated +Neutral contactor , Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, the ACBs must be provided with terminal adaptors (Hr Vr), ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. (Where Syncronization is required)
INCOMER FROM DG SET-II (400 kVA) 1 Nos. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated +Neutral contactor , with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Where Syncronization is required) BUS - COUPLER-I & II 1 No. 1600Amps 4P EDO type Air circuit breaker without protection release of fault breaking capacity 50KA (Ics=Icu=Icw upto 433V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB, terminals suitable for Bus bar connections on both sides.
Wherever 4 Pole ACBs used, it shall have fully rated neutral equal to rating of the breaker & shall be protected against over-load faults with provisions for settings neutral unprotected, neutral protection at 0.5In and neutral protection at 1.0 In to ensure precise neutral protection. Provide seprate 3Nos. Dual ratio dual tape Resin Filled Nylon 66 Casing CTs, Class-1, in each transformer Incoming for single to capacitor panel APFCR. CT-Operated Enersol make- MFR-4810 Multi Function Panel mounted Meter - (96 mm x 96 mm) covering Load Manager MF 48 with Import/Export & RS485 port all electric basic, Power & Energy parameters 4 quadrant including THD% V& A phasewise for all incommers with class - 1.0 accuracy. CT-Operated Enersol make- MF-4210 Multi Function Panel mounted Meter - (96 mm x 96 mm) covering Load Manager MF 42 without RS 485 Port , All electric basic, Power & Energy parameters including THD% V& A phasewise for all outgoing with class-1.0 accuracy. OR
Single phase preventer, Under/Over voltage relay for each transformer & D.G. set Incomer with indicator for trip and hooter for alarm. Reverse power relay for each D.G. set Incomer with indicator for trip and hooter for alarm Phase Reversal relay for each Transformer incomer with indicator for trip and hooter for alarm. Provide control accessories like automatically controlled constant voltage constant current, 24/12 V DC battery charger with battery charging indication, battery charged indication, Over charged battery protection, low battery protection, High Voltage protection, charger on - AC, DC Ammeter, DC Voltmeter, 8 window fault annunciater with inbuilt P.B and Hooter, trip alarm and reset etc. for each D.G. Set incomer Provide 8 window annunciator with hooter , 2 Window for over Current & Earth fault, 2 Window for OTI alarm & Trip, 2 Window for WTI alarm & Trip & 2 Window Bucholz alarm & Trip ( If applicable) for each Transformer incomer Provide emergency stop Push Button Station for Emergency stop Head with Switching position indicator and yellow anti-lock collar, push to lock and turn to release. Legend - Emergency Contact - 1 NC. Metric knock outs for Cables entry Ref. Cat Number- Hensel PBS 0101 for each incomer ACB/MCCB
TVSS & BUSBARS SECTIONS 2000 Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1 Amps/sq.mm for Aluminium and 2 Amps/sq.mm for copper cross sectional area of Bus Bar. Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up < 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.
OUTGOINGS CONNECTED AS SHOWN IN SLD: 2 Nos.1000 Amps 4P MDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, the ACBs must be provided with terminal adaptors (Hr Vr), ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for bus bar connection at input side and XLPE Cable connections on output side.
2 Nos.800 Amps 4P MDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, the ACBs must be provided with terminal adaptors (Hr Vr), ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for bus bar connection at input side and XLPE Cable connections on output side.
6 Nos. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended 1 Nos. 400A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended
5 Nos. 250A TP+NL MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C & adjustable E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended 4 Nos. 200A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended
2 Nos. 160A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended 3 Nos. 100A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended
1 Nos. 63A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended Earth leakage protection relay with 300mA to 3000mA with ZCT for each outgoing MCCB. PLC FOR INTERLOCKING, SYNCHRONISING & LOAD MANAGEMENT PLC based Automatic / Manual Synchronisation and check synchronising Panel with auto and manual operation and Load Manager for both Mains and DG power, whose function will be to determine the Load, decide how many DG sets to be synchronised, perform Synchronisation and supply power to the load. Supplier to submit the Bill of materials for the above functions also provide motorised potential meter for each generator for voltage correction.
Supplying,Receiving, fixing, testing & commissioning of above described main LT Panel. Note: Incomers for Transformer, D.G. sets & Bus couplers shall be electrically & mechanically interlocked and quoted price shall be inclusive of all.
Capacitor Panel-1 (300 KVAR) INCOMER 1 No.630 Amps TPN MCCB METERING & INDICATION 1 set of phase indicating lamps 1 No. Microprocessor APFC controller/Relay shall continuously monitor all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand,KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232 C port. Controller should mounted on the front side of the panel.
BUS-BAR 1 Set of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 1 Nos.of 250A TP MCCB with suitable AC -3 duty contactor 3 Nos.of 125A TP MCCB with suitable AC -3 duty contactor 2 Nos.of 63A TP MCCB with suitable AC -3 duty contactor 2 Nos.of 20A TP MCCB with suitable AC -3 duty contactor 1 Nos. 100 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 3 Nos. 50 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 2 Nos. 20 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly.
2 Nos. 5 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. Note:The capacitor panel shall also stipulate the following (i) All the capacitors shall be suitable for 525 V (ii) Necessary control and firing card with proper wiring and lugs of the required rating to be provided. (iii) Heavy duty exhaust fans to be provided for cooling (iv) LED indication for number of capacitor banks ‘ON & Power Factor lagging or leading. (v) The APFC shall be protected from following * over-voltage & voltage unbalance * Over temperature-system should be in standby mode and automatically restart after above condition restored. * Total Harmonic Distortion Supplying,Receiving, fixing, testing & commissioning of Capacitor panel as described above of Capacitor panel as described above
Supply and Erection of MS angle iron bucket stand which include 6 Nos. fire bucket with 9 ltr. Capacity with sand filling including cost of fabrication, welding and painting of complete stand & buckets with one coat of red oxide and two coats of approve paint of red color written with fire on the buckets as per fire protection with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work.
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 3mm thick, suitable for 11 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2mm thick, suitable upto 3.3 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. These charts shall be framed in wooden frame and covered with clear glass.
Supply of First aid box as approved by St. John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying of Rubber gloves of 11 KV grade as per IS 4770-68.
Supplying and fixing of MS sheet board of size 500mm x 300mm of 16 SWG with 'Entry Restricted to Authorised Person Only" near the main entrance of the Sub- Station. The lettering shall be black painted on yellow base or as approved by engineer incharge.
Supply and fixing safety instruction chart both in Hindi & English duly framed with 3 mm thick glass as required. (approximate front area 1.00 sq. Meter)
SCHEDULE OF QUANTITIES FOR SUPPLYING, INSTALLATION, TESTING & COMMISSIONING OF STRUCTURE CABLING, IP-PBX, LAN, Wi-Fi, CCTV SYSTEM, AND FA-PA SYSTEM (BALANCE WORKS FOR GMC KATHUA) EPABX Machine Make-ALCATEL/MATRIX/AVAYA/NORTEL OXO Connect/Office M-L (AA32) Alcatel-Lucent OXO Connect Large - 220V = 1 Expansion module Rack 2 (without power cord) = 1 Voice boards (AA35) Module link kit 1 for first additional expansion module including : 2x HSL1 Daughterboard and one PowerMEX controller board and one Uplink cable = 1 Analog mixed board AMIX4/4/4-1 with 4 analog trunks‚ 4 Reflexes ports and 4 analog sets ports = 1 Analog Interfaces Board SLI16-2 : 16 analog interfaces = 9 Analog Interfaces Board SLI8-2 : 8 analog interfaces = 1
Digital Public Access Board - 1 Primary Rate E1 T2 Access = 1 Data infrastructure (AA36) "Power cord country UK2 (ZA3 - India, South Africa) for OmniPCX Unit 1,2 3" = 1 Mounting kit for Rack 3 = 1 Mounting kit for Rack 2 = 1 Blind slot stiffner (x1) = 1 OXO Connect software licenses (CC31) "OXO Connect R3 software Suite for OXO Connect Compact, Small, Medium and Large. Not compatible with Compact C25 and Evolution." =1 1 Universal Telephony License for new OXO Connect systems. SoftwareAssurance mandatory = 160 9 series terminal (DD17) "8039 INT Premium Deskphone Moon Grey, 4 grey level display, white backlight, Handsfree, Comfort handset, Magnetic alphabetic keyboard, Jack 3,5 mm 4 poles" = 2
Software Assurance SMB (GG15) OXO Connect software assurance for 3 years = 160 Alcatel services (GG41) "Alcatel-Lucent Integration Service for OXO Connect Large, service including the download of the software, soft.licenses, boards and blind slots integration, delivered with the power cord" = 1
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.
200 pair tag box
50 pair tag box
20 pair Tag block
Supply, laying, testing and commissioning of following size of 0.61mm dia copper conductor multi pair telephone cable as per suitable for indoor telephone wiring conforming for ITD S/WS - 113 C and S/WS - 114 (actual qty. may vary as per site) in existing conduit/ trench/ tray.
50 pair Ar. Cable
30x PTZ Camera - 1/2.8-inch Type Exmor CMOS Sensor ; 1920 x 1080 , 1080P,f/1.6 ~ f/4.7, focal length 4.3 mm (wide) ~ 129.0 mm (tele) , 30X optical, 12X digital, 256 Presets, RJ-45 Data Port for Software Update and Setup, 360° continuous pan rotation, Operating Temperature 0° to 50°C (32° to 122°F).
Keyboard Controller with joystick
Type-I Switch (Core Switch)- Layer-III 24 port switch or as required for interconnection to station LAN
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required 3X1.5 Sq. MM Cable
Supply, installation, testing and commissioning of 4-Channel NVR
Supply, installation, testing and commissioning of Fiber Optic Patch Cords (Duplex)
Supply, installation, testing and commissioning of Waterproof box for PTZ camera with power socket
Supply, installation, testing and commissioning of 2-Meter height pole for PTZ camera
32 mm GI Flexible Conduit
25 mm GI Flexible Conduit
GI Raceway 300X50mm with accessories
GI Raceway 300X50mm with accessories
Supply, installation, testing and commissioning of SFP Modules
Supply , installation, testing & commissioning of smart card readers as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories
Supply, installation, testing and commissioning of Finger print (Biometrics) readers with keypad suitable for mounting on metal surface/ metal frames or wooden frames or wall or as required based on site conditions including all accessories.
Supply, installation, testing and commissioning of Smart Cards type re-programmable and site printable proximity cards with inbuilt memory of 4 KB complete as per specification
Supply, installation, testing and commissioning of Two Door Controller for Controlling the above card readers with LAN onboard, TCP/IP interface as per specification mentioned including all accessories. (Tenderer to mention quantity of controllers based on their system and all controllers shall be installed in the BMS room only.) Central access control controller complete with tamper switch, power electronics tamper switch etc. which with connect to the door controllers as stated above, if required
Supply, installation, testing and commissioning of electromagnet door holder (fail safe type) of 15 lb holding force for the following doors :
Double Leaf Door (Drop Bolt)
Single Leaf Door (Drop Bolt)
Supply, installation, testing and commissioning of door open break glass switch for individual access control door. This shall be located in a powder coated lockable enclosure housed in control room. Quoted price shall be inclusive of wires running in 25 mm dia MS conduit between door and this switch.
Supply, installation, testing and commissioning of Door Contact
Supply, installation, testing and commissioning of door open switch or push button for individual access control door.
Supply, installation, testing & commissioning of Card Printer as per specifications.
Supply, installation, testing & commissioning of Card Programming Unit for field programming of proximity cards.
Supply, installation, testing & commissioning of SQL Server Software and SP 2 with five client software for intergration with Owner's SAP based system for Attendence/ Payroll records complete with all accessories as required. (All the softwares shall be licences version. High end Server shall be provided by the client. The Tenderer shall quote the system complete as required.
Z-L bracket for magnetic
Supply, laying, testing and commissioning of the following cables in existing 25 mm dia MS conduits
8 Conductor, 18-24 AWG, with sheild
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Tendernotice_2.pdf
PDF • 0.31 MB
BOQ_360172.xls
BOQ • 0.38 MB
Make.pdf
Additional Documents • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .