| Sl No | Description | Qty | Unit | PAL ELECTRICAL L3 | MODERN ENGINEERING ENTERPRISE L1 | A.K. ELECTRICAL & GENERAL CONTRACTOR ORDER SUPLLIERS L4 | NIRMAN ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.01 | Supply, Installation and Testing of LCD display with CPU having following details--One to ten isolated intelligent Signalling Line Circuits (SLC) Style 4, 6 or 7. (ii) Large 16 line, 640 character LCD backlit display or use display-less as a network node with QWERTY Keypad. (iii) Built-in Alarm, Trouble, Security, and Supervisory relays. (iv) VeriFire Tools online/offline program option. (v) History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. (vi) Advanced history filters allow sorting by event, time, date, or address. (vii) Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. (viii) EIA-232 printer port. (ix) EIA-485 annunciator port. (Make-Honeywell/CPU2-3030D) | 1 | Item | 1,52,500 ₹1,52,500 | 1,50,000 ₹1,50,000 Lowest | 1,51,000 ₹1,51,000 | 1,50,000 ₹1,50,000 Lowest |
| 2.00 | Supply, Installation, & Testing of Microprocessor controlled. IP Addressable Multi-sensor detector IP 54 (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smoke
Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable
Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Honeywell (Notifire/FSP-951T +B501) /Cerberus Pro / Johnson Controls/ Edward/ Secutron Apollo/ Morley/ Eaton/GST/ Ravel) | 69 | Nos | 2,900 ₹2,00,100 | 2,770 ₹1,91,130 Lowest | 2,950 ₹2,03,550 | 2,825 ₹1,94,925 |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator (Note : Hooter Cum Storbe without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices, Numbers of addressable devices in a group will be as per latest recommended standards of IS-2189 without any additional cost). ( VDS / UL / FM / ULC approved) approved. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell ( (FCM-1))/ Apollo/ Morley/ Eaton/GST/ Ravel) | 4 | Nos | 5,500 ₹22,000 | 4,950 ₹19,800 Lowest | 5,500 ₹22,000 | 5,111 ₹20,444 |
| 4.00 | Supply and Installation of loop control module, which can detect 159 Smoke cum heat detector. (Make- Notifier/LCM-320) | 1 | No | 67,100 ₹67,100 | 66,000 ₹66,000 | 66,000 ₹66,000 | 65,500 ₹65,500 Lowest |
| 5.00 | The system testing,commissioned and software upgradation a by qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tested for the system . (2) Before energizing the cables and wires, check for correct connections and check for short circuit, ground fault, conntunuity, and insulation and other tests as per above standard must done. ( agency should certify that all loop conections,FCM connections, MCP, Hooter, and all other connection is healthy and well manner and also provided two copies of connection diagrame of present circuit certified by concern Supervisor / Engineer). 4 person experienced technician support (Including Fooding and Lodging)- 16 days, One Senior Engineer support (Including Fooding and Lodging)- 16 days. | 2 | Job | 55,900 ₹1,11,800 | 53,000 ₹1,06,000 Lowest | 56,500 ₹1,13,000 | 55,350 ₹1,10,700 |
| 6.00 | SIT&C of Intelligent Addressable pull/ Glass break type manual call point with key aggangement to activate manual alarm. Code dial addressing (UL listed) (Make-Honeywell (Notifire/F-MCP-Glass)/ Simplex/ Siemens/ Bosch/ Secutron) | 2 | Nos | 3,264 ₹6,528 | 3,200 ₹6,400 Lowest | 3,400 ₹6,800 | 3,290 ₹6,580 |
| 7.00 | SIT & C of Fault Isolator module to isolate shorted desired and loose circuits between two successive fault isolators with automatic resetting arrangement (UL listed).(Make- Honeywell/ Notifire/ Simplex/ Siemens/ Bosch/ Secutron) | 4 | Nos | 4,100 ₹16,400 | 3,740 ₹14,960 Lowest | 3,900 ₹15,600 | 3,862 ₹15,448 |
| 8.00 | Supply, Installation,Testing & Commissioning of 12 Volt,7 AH SMF VRLA battery Charging Voltage : stand by-13.5 Volt and cycle- 14.7 Volt for five loop fire detection panel. (Make-Amaron/Exide) | 1 | No | 1,830 ₹1,830 | 1,700 ₹1,700 Lowest | 1,900 ₹1,900 | 1,800 ₹1,800 |
| 9.00 | Supplying and Laying 1.5 Sq mm 4 core FRLSH armoured cable inside the cable trench through 25 mm dia PVC conduit (Make-Pression-M) with conduit saddle, screw and mending the good damages. (Make- KEI/Finolex/polycab) | 510 | Mtr | 220 ₹1,12,200 | 214 ₹1,09,140 Lowest | 225 ₹1,14,750 | 221.5 ₹1,12,965 |
Tender Value
Refer Docs
EMD Value
₹13,304
Closing Date
9 Feb 2024, 12:55 pmClosed
E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
O/O The EXECUTIVE ENGINEER P.W.DTE Birbhum Electrical Division P.O. Suri Dist Birbhum Pin 731101
Emergency repairing of existing Fire detection system at Sub Divisional Hospital, Bolpur, in Birbhum.
2024_WBPWD_656499_1
BIRED/57/e-NIQ (1st call) of 2023-2024
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
BOLPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹13,304
OFC OF THE E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
8 Jul 2026
30 Jan 2024
12 Feb 2024
30 Jan 2024
9 Feb 2024
1 Feb 2024
1 Feb 2024
Amount
Supply, Installation and Testing of LCD display with CPU having following details--One to ten isolated intelligent Signalling Line Circuits (SLC) Style 4, 6 or 7. (ii) Large 16 line, 640 character LCD backlit display or use display-less as a network node with QWERTY Keypad. (iii) Built-in Alarm, Trouble, Security, and Supervisory relays. (iv) VeriFire Tools online/offline program option. (v) History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. (vi) Advanced history filters allow sorting by event, time, date, or address. (vii) Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. (viii) EIA-232 printer port. (ix) EIA-485 annunciator port. (Make-Honeywell/CPU2-3030D)
Supply, Installation, & Testing of Microprocessor controlled. IP Addressable Multi-sensor detector IP 54 (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smoke Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Honeywell (Notifire/FSP-951T +B501) /Cerberus Pro / Johnson Controls/ Edward/ Secutron Apollo/ Morley/ Eaton/GST/ Ravel)
Supply, Installation, Testing & Commissioning of Addressable Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator (Note : Hooter Cum Storbe without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices, Numbers of addressable devices in a group will be as per latest recommended standards of IS-2189 without any additional cost). ( VDS / UL / FM / ULC approved) approved. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell ( (FCM-1))/ Apollo/ Morley/ Eaton/GST/ Ravel)
Supply and Installation of loop control module, which can detect 159 Smoke cum heat detector. (Make- Notifier/LCM-320)
The system testing,commissioned and software upgradation a by qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tested for the system . (2) Before energizing the cables and wires, check for correct connections and check for short circuit, ground fault, conntunuity, and insulation and other tests as per above standard must done. ( agency should certify that all loop conections,FCM connections, MCP, Hooter, and all other connection is healthy and well manner and also provided two copies of connection diagrame of present circuit certified by concern Supervisor / Engineer). 4 person experienced technician support (Including Fooding and Lodging)- 16 days, One Senior Engineer support (Including Fooding and Lodging)- 16 days.
SIT&C of Intelligent Addressable pull/ Glass break type manual call point with key aggangement to activate manual alarm. Code dial addressing (UL listed) (Make-Honeywell (Notifire/F-MCP-Glass)/ Simplex/ Siemens/ Bosch/ Secutron)
SIT & C of Fault Isolator module to isolate shorted desired and loose circuits between two successive fault isolators with automatic resetting arrangement (UL listed).(Make- Honeywell/ Notifire/ Simplex/ Siemens/ Bosch/ Secutron)
Supply, Installation,Testing & Commissioning of 12 Volt,7 AH SMF VRLA battery Charging Voltage : stand by-13.5 Volt and cycle- 14.7 Volt for five loop fire detection panel. (Make-Amaron/Exide)
Supplying and Laying 1.5 Sq mm 4 core FRLSH armoured cable inside the cable trench through 25 mm dia PVC conduit (Make-Pression-M) with conduit saddle, screw and mending the good damages. (Make- KEI/Finolex/polycab)
NIRMAN ENTERPRISE
PAL ELECTRICAL
A.K. ELECTRICAL & GENERAL CONTRACTOR ORDER SUPLLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .