Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.6 L+₹63,300 (3.34%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹19.9 L+₹92,330 (4.87%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹20.0 L+₹1.0 L (5.38%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹21.3 L+₹2.3 L (12.4%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
3 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Udhampur
AIR FORCE STATION UDHAMPUR
REPAIR AND REPLACEMENT/ MAINTENANCE OF SUMMER APPLIANCES AND OTHER MISC WORKS AT AIR FORCE STATION UDHAMPUR
2022_MES_507242_1
GE/AFU-52/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
AF STATION UDHAMPUR
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE AF UDHAMPUR
₹40,000
Yes
7 Jun 2022
10 Feb 2022
5 Mar 2022
10 Feb 2022
3 Mar 2022
24 Feb 2022
11 Feb 2022 - 18 Feb 2022
60 days
Amount
Servicing and maintanence for Indoor unit split type Air conditioners of any type / capacity taking down carefully indoor unit servicing and cleaning for all filter, blower, Indoor coil assy, PCB terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, incl good cleaning carefully for out side area used saft cloth with coolin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
Servicing and maintanence for Out door unit for split AC and window Air conditioners of any type / capacity servicing , cleaning for all filter, fan blade , coil assy, terminal block, frame grill assy, coil guard incl greasing for fan motor complete with reassembling the same one, incl good cleaning carefully for out side area used saft cloth with coolin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
Taking down carefully split type Air conditioners of capacity 1.5 Ton of any make for carrying out the repairs and reassembling the same after the repairs, installation and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
Taking down carefully split type Air conditioners of capacity 2 Ton of any make for carrying out the repairs and reassembling the same after the repairs, installation and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
Disconnecting, cutting and taking out condensor Coil assy for indoor / outdoor unit find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge. Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
Disconnecting, cutting and taking out unserviceable compressor (R-22 gas ) for 1.5 Ton Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
Disconnecting, cutting and taking out unserviceable compressor (R-22 gas ) for 2 Ton Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
Disconnecting, cutting and taking out unserviceable compressor (R-410a gas ) for 1.5 Ton Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
Supply and replacing thermostate switch for 1.5 Ton capacity Air conditioner single phase 240 Volts and 2 Ton Air conditioner 415 Volts, complete all as specified and as directed Make :- Renutrol/Indfoss or equivalent as approved by GE.
Supply and replacing control card (PCB) of inner unit of 1.5 Ton AC, complete all as specified and as directed
Supply and replacing (existing same size ) Indoor unit blower motor for 1.5 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) Indoor unit blower/ fan and bushes for 1.5 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) Indoor unit blower motor for 2.0 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) Indoor unit blower / fan and bushes for 2 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) outdoor unit blower motor for 1.5 Ton capacity AC, complete all as specified and as directed
Supply and replacing existing same size ) outdoor unit blower /Fan blade with bushes for 1.5 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) outdoor unit blower motor for 2.0 Ton capacity AC, complete all as specified and as directed
Supply and replacing (existing same size ) outdoor unit blower/Fan blade with bushes for 2.0 Ton capacity AC, complete all as specified and as directed
Supply and replacing Hot and cold valve for 1.5/2.0 Ton capacity AC, complete all as specified and as directed
Supply and replacing window AC fan motor for 1/1.5/2 Ton capacity AC, complete all as specified and as directed
Supply and replacing window AC fan motor blade / fan for 1/1.5/2 Ton capacity AC, complete all as specified and as directed
Supply and replacing running capacitor 45 mfd + 10 mfd (combined unit), complete all as specified and as directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
Supply and replacing running capacitor 36 mfd + 10 mfd (combined unit), complete all as specified and as directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
Supply and replacing starting capacitor 80 mfd - 100 mfd, complete all as specified and as directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
Supply and replacing starting capacitor 60 mfd - 80 mfd, complete all as specified and as directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
Supply and replacing running capacitor 10 mfd + 10 mfd (combined unit), complete all as specified and as directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
Supply and replacing starting relay of 1.5/2.0 Ton window complete all as specified and directed by Engineer-in-Charge. Make :- Renutrol/Indfoss
Supply and replacing route pipe (copper tube) of size 3/8" dia complete with insulation complete all as specified and as directed by Engineer-in-Charge.
Supply and replacing route pipe (copper tube) of size 5/8" dia complete with insulation complete all as specified and as directed by Engineer-in-Charge.
Supply and replacing route pipe (copper tube) of size 1/4" dia complete with insulation all as specified and directed by Engineer-in-Charge.
Supply and replacing route pipe (copper tube) of size 1/2" dia complete with insulation complete all as specified and as directed by Engineer-in-Charge.
Supply and replacing filter flap for indoor unit (existing size ) complete set complete all as specified and as directed by Engineer-in-Charge.
Supply (existing same model)and replacing codensor outdoor unit complete for 1.5 ton AC complete all as specified and as directed by Engineer-in-Charge.
Supply(existing same model) and replacing codensor outdoor unit complete for 2.0 ton AC complete all as specified and as directed by Engineer-in-Charge.
Supply and refilling of gas R-22 in 2 Ton/1.5 Ton AC including necessary arrangement for gas filling complete all as specified and as directed by Engineer-in-Charge.
Supply and refilling of gas R-410a in 1.5 Ton AC including necessary arrangement for gas filling complete all as specified and as directed by Engineer-in-Charge.
Supply and replacing thermal overload relay for 1.5/2.0 Ton AC complete all as specified and as directed by Engineer-in-Charge. Make :- Renutrol/Indfoss
Supply and replacing Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA.(Make : V- Guard model VWR 400 equivalent Micro tech) complete all as specified and as directed
Supply and replacing Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.(Make : V- Guard model VWR 400 equivalent Micro tech) complete all as specified and as directed
Supply and replacing Taking out the voltage stabilizer of capacity 3 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, complete all as specified and as directed
Supply and replacing control card of voltage stabilizer PCB sensor etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and replacing Ics and relays complete all as specified and as directed by Engineer-in-Charge.
Taking out the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge complete all as specified and as directed.
Replacement of compressor sealed unit including necessary brazing work as required complete all as specified and as directed
Replacement of Thermostate switch suitable for 280/310 Ltrs caapcity refrigerator complete all as specified and as directed Make :- Renutrol/Indfoss or equivalent as approved by GE.
Refilling of gas in the compressor of refrigerator of any make and capacity with R-134a gas/ carbon free gas complete all as specified and as directed.
Replacement of thermal overload relay for 280/310 Ltrs capacity refrigerator complete all as specified and as directed. Make :- Renutrol/Indfoss or equivalent as approved by GE.
Disconnecting the refrigerator of capacity 165/210 ltr and replacement of the following spares required for repair work including reassembly and testing complete all as specified and as directed
Replacement of Thermostate switch suitable for 165/210 Ltrs caapcity refrigerator complete all as specified and as directed. Make :- Renutrol/Indfoss or equivalent as approved by GE.
Capilliary tube including brazing work complete all as specified and as directed.
Replacement of thermal over load relay complete all as specified and as directed.
Replacement of compressor sealed unit including necessary brazing work as required complete all as specified and as directed.
Supply and replacement of Ics and relay complete all as specified and as directed.
Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completion of job, complete all as specified and as directed.
Replacement of compressor sealed unit including necessary brazing work as required complete all as specified and as directed. Make ; Voltas/ blue star/ carrier
Replacement of thermal over load relay complete all as specified and as directed. Make :- Renutrol/Indfoss or equivalent as approved by GE.
Supply and refilling of gas including necessary arrangement for gas filling complete all as specified and as directed.
Replacement of Thermostate switch. Make :- Renutrol/Indfoss or equivalent as approved by GE.
Taking down indoor/outdoor unit of capacity 1.5/2.0 ton capacity after opening electrical connections, securing the refrigerant gas in the compressor and opening refrigeration pipe line safely. Shifting the inddor/outdoor unit for fixing at new places, mounting after drilling hole over out door unit stands, connecting refrigeration pipe line with indoor unit, electrical connection and charging refrigeration gas complete all as specified and directed by Engr-in-Charge. Note :- Additional Refrigerant gas and copper pipe line and insulation will be measured and paid for separately
Supply and replacement of out door unit with compressor complete set for split type AC 1.5 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
Supply and replacement of out door unit with compressor complete set for split type AC 2.0 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
Stands for outdoor unit including drilling hole, nuts bolts , fastners etc complete all as required at site.
Submain wiring with 2 x single core PVC insulated flexible copper conductor cable FRLS of size 4 sqmm and one single core PVC insulated flexible copper conductor cable of green colour of size 4.0 Sqmm as earth lead in & including surface PVC conduit light grade fixing to wall with clamps complete all as specified and directed by Engr-in-Charge including taking down old.
Submain wiring with Four single core PVC insulated flexible copper conductor cable FRLS of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including surface PVC conduit light grade fixing to wall with clamps complete all as specified and directed by Engr-in-Charge including taking down old. Note: Four runs of 6 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
Supply and replacement MCB single pole 240 volts 5 to 30 amps C' Curve, with rupturing capacity 10 KA, complete all as specified and as directed
Supply and replacement MCB single pole & neutral 240 volts 20 amps C' Curve,with rupturing capacity 10 KA, complete all as specified and as directed
Supply and replacement MCB TPN 240 volts 32 amps C' Curve,with rupturing capacity 10 KA, complete all as specified and as directed
Supply and replacement of distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCB TPN as incommer and MCB SP as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete all as required at site or complete all as specified and as directed by Engr-in-Charge.
Taking down old wiring and Point wiring for 3 pin switch socket outlet 15 Amp independent with FRLS 2.5 Sqmm copper conductor cable (multi strand) PVC insulated and unsheathed in and including concealed PVC conduit of adequate size to be fixed on wall with clamps terminated in sunk cast iron pressed steel terminal box for mounting switches, sockets, etc with 3mm thick plastic laminated sheet cover of adequate size including continuous FRLS 1.5 Sqmm PVC insulated and unsheathed multistrand copper conductor earth wire to common earth and connected to earth duly complete (except cables) complete all as specified and as directed
Supply and replacement Switch socket out let multi purpose 2 in one, 3 pin, 6 and 16 Amp flush type universal complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement the (exisiting model ) Plug Top 3 pin suitable for 230 Volts 50 HZ 16/20 Amps, complete all as specified and as directed
Supply and repalcement of wood wool pad set suitable for desert cooler complete all as specified and directed by the Engineer-in-charge.
DB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed by the Engineer-in-charge.
supply and replacement blower motor of water cooler 40/80, 60/120 and 150 Ltrs capacity connecting & testing on load complete all as specified and directed by the Engineer-in-charge.
Maintenance and servicing of water cooler 40/80, 60/120 and 150 Ltrs at site, cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch, condenser motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis connecting & testing on load for performance complete all as specified and directed by the Engineer-in-charge. Note :- Spares and gas required shall be measured and paid for separately.
Supply and replacement of push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler complete all as specified and directed by the Engineer-in-charge. Make :- Prayag/Parko or equivalent as approved by GE.
Supply and replacement of float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore complete all as specified and directed by the Engineer-in-charge. Make :- Prayag/Parko or equivalent as approved by GE.
Supply and replacement of motor 230 Volts, single phase, 1440 RPM for desert cooler complete all as specified and directed by the Engineer-in-charge. Make :- Khaitan/Universal or equivalent as approved by GE.
Supply and replacement of pump motor (Tullu pump) 230 Volts, single phase,for desert cooler complete all as specified and directed by the Engineer-in-charge. Make :- Khaitan/Universal or equivalent as approved by GE.
Supply and replacement air filter suitable for window type AC 1.5 Ton capacity as per samples complete all as specified and directed by the Engineer-in-charge. Make :- Voltas/LG/Blue star
Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver preparation of surface for painting with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling of the pump & motor complete all as specified and directed by the Engineer-in-charge. (a) Wiper (b) Plastic impeller of tullu pump with enclosure. (c) Distributor
Replacement of defrost timer for domestic refrigerator complete all as specified and directed by the Engineer-in-charge. Make :- Kelvinator/Godrej/Voltas/LG
Supply and replacement of indoor unit complete set for split type AC 1.5 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
Supply and replacement of indoor unit complete set for split type AC 2.0 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
Supply and replacement of relay for split type AC 1.5 ton capacity, contact relay per pole 22 V - 163 complete all as specified and directed by the Engineer-in-charge.
Supply and replacement of cable PVC insulated sheathed 3 core copper conductor size 4 sqmm complete all as specified and directed by the Engineer-in-charge.(make; havells/ polycab/ RR/ finolex)
Supply and replacement of cable PVC insulated sheathed 3 core copper conductor size 6 sqmm complete all as specified and directed by the Engineer-in-charge.
Supply and replacement of cable PVC insulated sheathed 3 core copper conductor size 2.5 sqmm complete all as specified and directed by the Engineer-in-charge.
Supply and replacement of PVC drain pipe 3 mtr lenth suitable for All type AC all as specified and directed by the Engineer-in-charge.
Supply and replacement of PVC drain pipe 1 mtr lenth suitable for All type AC all as specified and directed by the Engineer-in-charge.
Note :- Credit schedule has been given separately under tender documents and shall be adjusted in general summary by the deptt. for arriving at net contract sum.
K S BUILDERS
CITY TOP ELECTRICAL WORKS
VARDHMAN INTERNATIONAL
ARNABH ASSOCIATES
shivom builders
SHARMA SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .