Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC NOT AVAILABLE | ₹48.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹49.8 L+₹94,198 (1.93%)Rejected-Finance | ₹49.8 L+₹94,198 (1.93%) | L2 | Rejected-Finance Not Reasonable |
| 3 | L3₹50.0 L+₹1.2 L (2.40%)Rejected-Finance TRIVANDRUM | ₹50.0 L+₹1.2 L (2.40%) | L3 | Rejected-Finance Not Reasonable |
| 4 | L4₹51.0 L+₹2.2 L (4.43%)Rejected-Finance | ₹51.0 L+₹2.2 L (4.43%) | L4 | Rejected-Finance Not Reasonable |
| 5 | L5₹52.9 L+₹4.0 L (8.26%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | ₹52.9 L+₹4.0 L (8.26%) | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹77 L
EMD Value
₹1.5 L
Closing Date
2 Nov 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
SPECIAL REPAIRS TO BUILDING NO P-5 (NEST) UNDER GE (WEST) COLABA MUMBAI
2023_MES_623088_1
8807/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE(W) Colaba, Mumbai
₹1.5 L
Yes
8 Jan 2024
13 Oct 2023
4 Nov 2023
13 Oct 2023
2 Nov 2023
27 Oct 2023
Amount
Dismantling Mangalore patteren or similar tiles in roofing including portions bedded in cement mortar all as specified and directed.
Dismantling Battens for tiles, shingles of any size including tilting fillets not exc 15 cm all as specified and directed.
Dismantling timber in scantlings 40 sq. cm and over in section, in any position all as specified and directed.
S&F in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height all as specified and directed.
M&L in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including scafoldings of any height all as specified and directed.
M&L Second class hard-wood clean sawn timber in scantlings all as specified and directed.
M&L second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n exc 25 Sqcm including scafoldings of any height all as specified and directed.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified & directed.
Fixing only Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified & directed.
M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any height all as specified and directed.
S&F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados laid, bedded and pointed in any mortar and removal of rubbish off the site outside MD land all as specified & directed.
M&L Granite (of any type and colour) 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design over 20 mm thick screed bed in cement mortar 1:4 all as specified and directed.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) (Note: thickness shall be measured excluding plaster)
Cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry and Applying two coats of epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/ Krishna Conchem) as approved by the Engineer-in-Charge for old and new reinforcement any dia all as specified and as directed. Note : - Length of reinforcement bars cleaned of rust all around shall be measured for payment.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height all as specified and as directed.
M&L mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed
Providing and placing in position micro-concrete, grade M40, which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion, obtained from Fosroc / SIKA / BASF/ Dr Fixit, thickness of section upto 75 mm all as specified and as directed by the Engineer in charge (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument and including necessary form work)
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and as directed.
M&L for repairs to sunken portion of slab.Treatment of sunken floor slab compraises of the following specifications :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout . (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt. of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured & paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty . (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating with DR. FixiT Pidicrete URP with cement Ratio 1:1.5 as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried out for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to full height of sunken with minimum 20mm thick CM 1:4 mixed with integral water proofing compound ( DR.Fixit Pidifin 2K) 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint Note 1 :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of MES and record for each sunken slab shall be maintained. Cost of testing is inclued in the rates quoted above. For the purpose of payment area of bottom and sides of sunken shall be measured in sqm
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises all as specified and as directed.
M&L for 1200 x 600 vitified tiles light shade 10 mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified & directed.
M&L Hi-Gloss digital ceramic tiles in vertical surface of size 600mm x 1200mm and 8 to 10 thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified and as directed. Note : The above item will be executed by applying tile adhesive of approved make and as per manufacture instruction.
M&L rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
M&L Screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for laying floor finishes all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and as directed.
M&L for providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre with & including Hangers 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long for any sunk or raised moulding all as specified & directed.
M&L for PVC insulation panels with EPS stuck to 1mm thick printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing all as specified and as directed.
S&F Aluminum tubular hollow section 25 x 25 mm not exceeding 900 mm c/c on exceeding columns/beam/ slab to hold cladding and fixing Aluminium composite panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes all as specified and directed.
Aall as per Item No 33 above but in riser of steps, skirting, dado and pillar laid over cement screed and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
Taking down cement plaster of any description from brick wall surfaces including racking out joints and hacking for key, scrubbing down with water all as specified and as directed.
M&L for 12-15mm thick Ready Mix Plaster in single layer of make / brand - ACC's Accoplast / CK Birla's Aerocon / Ambuja, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces, (upto 05 storeys of bldgs) including use of scaffolding all as specified and directed. Note :- Liquid water proofing compound will be measured and paid seperately as supply only.
Supply only liquid water proofing compound.
M&L plastering 20-25mm thick (Avg) ready-mix epoxy based Polymer modified cement mortar in two coats, 15mm base coat and subsequent finishing coat with and including curing as per manufacturer's instruction all as specified and as directed by Engr-in-Charge. Make- Dr Fixit Repair Pro Polymer Mortar, FOSROC-RENDOROC S2-structural grade Polymer Mortar, Shalifix FRM Polymer Modified Fibre Reinforced Mortar of STP or equivalent as approved by the Engineer-in-Charge
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and as directed.
M&L for preparetion of new plastered surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surface all as specified and as directed..
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2mm thick (average) wall putty all as specified and directed.
complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface all as specified and directed.
M&L for preparation of old painted wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, zinc primer all as specified and directed.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed..
M&L for french polishing on new wooden surfaces of any description, width or girth including cleaning and preparing the surfaces and a coat of wood filler with two or more coats all as specified and directed..
M&L in repairs for 20 mm dia fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement all as specified and directed. Note : The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.
S&F in repairs PVC (SWR) floor trap with grating including jointing with solvent cement, 75mm diameter of outlet all as specified and directed.
S&F in repairs PVC (SWR) multi floor trap with grating including jointing with solvent cement, 75mm diameter of outlet all as specified and directed.
S&F in repairs chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws all as specified and directed. Make Kerovit Cat Part No - KA 930003 /Kohler
S&F in repairs brass chromium plated towel rack with 3 hooks 18" (Oval Range) all as specified and directed. Make Kerovit Cat Part No - KA 980011 /Kohler
S&F in repairs chromium plated towel rings fixed with screws all as specified all as specified and directed. Make Kerovit Cat Part No -KA 670005 /Kohler
S&F in repairs corner glass shelf 200 mm(brass brackets) Make Kerovit Cat Part No - KA920009 /Kohler complete all as specified.
S&F in repairs wall mixer 3 -in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe, connecting legs and wall flange (without hand an overhead shower) all as specified and directed. Make Kerovit Cat Part No -KB1511018 /Kohler
S&F in repairs Five Function Hand Shower with Hook 120 mm Dia. Including PVC Chrome Tube- 1.5 M (Suitable For All Hand Showers). All as specified & directed by Engg-In-Charge. Make Kerovit cat part no - KA530002 for hand shower & KA540001 for Tube.
S&F in repairs brass chromium plated shower rose 300 mm size with arm and with or without swivel joints to steel pipe or union all as specified and directed. Make :Kerovit cat part no- KA570004 for shower and Cat Part KA940002 for shower Arms/Kohler
S&F in repairs 15 mm bore chromium plated Angular stop valve with wall flange of cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed all as specified and directed. Make Kerovit Cat Part No - KB611003 /Kohler
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality suitable for hot and cold supply all as specified and directed. Make Prayag Cat part No BCT-04/Polytuf
S&F in repairs wash hand basin table top of size 460x345x130 mm vitrous China including, waste coupling & PVC waste pipe of 32 mm dia all as specified and directed. Make Kerovit cat part No - YORKSHIRE - KO2085 /Kohler
S&F in repairs Bottle trap having minimum water seal of 25mm all as specified & directed. Make Kerovit cat part no - KA870002
S&F in repairs Brass CP pillar cock with extension body including all necessary fittings screwed down for iron pipe for Wash Hand Basin all as specified and directed. Make Kerovit Cat Part No - KB411002/Kohler
M&L single piece WC with PP thin rim seat cover white, fixing accessories, set and cistern fitting size 665x355x770 mm and necessary fittings all as specified and directed. Make Kerovit ROBB's - KS712/Kohler
S&F in repairs toilet paper holder of stainless steel fixed to wall with CP brass screw all as specified and directed. Make Kerovit Cat Part No- KA980009 or Kohler complete all as specifed and as directed.
S&F in repairs 15 mm dia bore fancy type chromium plated 2 way angle valve with flange bib taps with wall flange cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, or for brass ferrule all as specified and directed. Make Kerovit Cat Part No - KB1311033 /Kohler.
S&F in repairs chromime plated, cast copper alloy jet spray with 1 mtr SS chrome plated hose and hook (for European seat) all as specified and directed. Make Kerovit Cat part No - KA580009/Kohler
Taking up or down steel tubing and connection including cleaning for refixing or removal to store15 mm dia bore all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store 20 mm dia bore all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removal to store 25 mm dia bore all as specified and directed
S&F GI tubing 15 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors all as specified and directed.
S&F GI tubing 20 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors all as specified and directed.
S&F GI tubing 25 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors all as specified and directed.
S&F Framed work such as grills, gratings with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as specified and directed.
Demolition and breaking up drain pipes of dia 100 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
Demolition and breaking up drain pipes of dia 75 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips all as specified and directed.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips all as specified and directed.
S&F PVC(SWR) bends suitable for 110 mm external dia all as specified and directed.
S&F PVC(SWR) bends suitable for 75 mm external dia all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal of 110mm dia all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal of 75mm dia all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal of 110 mm dia all as specified and directed.
S&F PVC (SWR) vent cowl of 110mm bore all as specified and directed.
Dismantling water tanks and removing to store all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (2000 litre, cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Cast iron work grade FG 150, unmachined, in brackets, gratings, railing, frames, manhole covers etc complete all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking of shutters from the frame) area exc 1.50 but not exc. 4.00 Sqm each all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking of shutters from the frame) area n exc 1.50 Sqm each all as specified and directed.
Taking down shutters of any description area exc. 1.00 Sqm but n exc 2.00 Sqm all as spcified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 100 mm X 50 mm size, applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold unserviceable fast/lugs/SS dash fasteners of required dia and length all as specified and as directed by Engr-in-Charge
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 62 mm x 32 mm size, applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold unserviceable fast/lugs/SS dash fasteners of required dia and length all as specified and as directed by Engr-in-Charge
S&F 40 mm thick flush shutters, solid core construction with particle bord core and plywood face panels, commercial type on both side and providing both side is covered with deco rative face veneer with lipping/ frame to match all as specified and as didrected.
S&F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge Make for Item No. 94 to 97- (a) M/S Rajshri Plastiwood, Indore (b) M/S Sintex Industries Ltd (c) M/S Accucell (d) M/S Dura Plast Extrusion
S&F powder coated/anodised aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, provn of AC opening and rubber beadings for fixing glass panes in frame all as specified and as directed. Note : (i) Glass panes will be measured & paid separately . (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clips, hinges, handle. However it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. Also gap between frame and wall shall be filled with silicon sealent. Make : Hindalco/Indal (Indian Al Coy)/Jindal/Associated Profile & Aluminium Ltd/Ajit India
M&L 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskit in square area exc 0.5 sqm in each pane frosted on one side all as specified and directed.
M&L in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or wooden/ Aluminium beadding all as specified and directed.
S&F 300mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts all as specified and directed.
S&F 200 mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts all as specified and as directed.
S&F 100 mm long Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 all as specified and as directed.
M&L 150 mm long Brass handles, cast type, polished bright all as specified and directed.
M&L french polishing on new wooden surfaces of any description, width or girth including cleaning and preparing the surfaces and a coat of wood filler with two or more coats all as specified and directed..
M&L for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described, treating small articles such as holdfasts, end of posts, backs of chowkhats area tarred n. exc. 0.1 sq m each and treated with tar or coal tar black paint all as specified and directed.
S&F 35 mm thick 2nd hard wood rail and style plain framed panelled shutters (any number of panels) with lock rail and panel of 9 mm thick B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S&F to chowkhats of 2nd class hard wood 35mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge, etc. sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a) all as specified and directed.
S&F 30 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides all as specified and directed.
S&F brass 300 mm, ordinary rat tail rod pattern springs, including roler and roller plate all as specified and directed.
S&F 75 mm butt hinges medium weight cold rolled stainless steel all as specified and as directed.
S&F aluminium anodised 100 mm barrel tower bolts of extruded section all as specified and directed.
S&F aluminium handle 75 mm cast type anodised all as specified and as directed.
S&F 3 mm thick sheet glass ordinary quality with oil putty in square n. exc. 0.5 sqm in each pane all as specified and directed.
S&F 150mm long gate and shutter aluminum hook and eyes all as specified an directed.
S&F 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 all as specified and directed.
RAJU AND COMPANY
Vandan Enterprises
Shetty Construction Co
Unity Enterprises
siddharth and company
Bidder Name
Shetty Construction Co
Unity Enterprises
Vandan Enterprises
siddharth and company
SHREE JAGDISH FURNITURE CO.
RAJU AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .