Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC JAISALMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.9 L+₹2.2 L (6.82%)Rejected-Finance STREET NO 11 SECTOR NO 4 TILAK NAGAR SAGAR ROAD BIKANER 334 001 RAJASTHAN | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹34.7 L+₹3.0 L (9.49%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹35.5 L+₹3.8 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹36.3 L+₹4.6 L (14.4%)Rejected-Finance JAISALMER | L5 | Rejected-Finance Not being lowest |
Tender Value
₹42.9 L
EMD Value
₹85,700
Closing Date
14 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPL REPAIRS TO BLDG NO. P- 634-01, P-634-02, P-635-01, P-635-02, P-636, P- 811 AND P-810 IN CERTAIN UNITS AT JAISALMER MIL STN
2024_MES_642587_1
8353/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹85,700
Yes
6 Apr 2024
15 Feb 2024
16 Mar 2024
15 Feb 2024
14 Mar 2024
29 Feb 2024
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar all as specified & directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish out side MD land all as directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) as in flooring & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles not exceeding 0.36 Sqm in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding in CM (1:6) complete all as specified & directed by Engineer-in-charge.
M&L vitrified tiles of light shade, 10mm thick (minimum) (square/ rectangular) polished area of each tiles equal to or not exceeding 0.36 sqm, on vertical surface such as skirting, dados, risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles laid over and including 10mm thick backing coat in CM (1:3) complete all as specified and directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic colour tiles 450X350X7mm thick jointless, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in CM (1:3) complete all as specified and directed by the Engineer in charge.
M&L for Non Skid ceramic tiles Exterior Grade 300x300x10mm thick jointed in neat cement slurry and pointed in coloured cement as in floor laid over and including screed bed or bedding layer of cement mortar in CM 1:6 for laying floor finish complete all as specified and directed by the Engineer in charge.
M&L Machine cut kota stone slab flooring 20- 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified & directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L for Granite of 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by the Engineer in charge.
M & L plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in coping including necessary form work with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified & directed by Engineer-in-charge.
Demolition of brickwork or stone/ boulder/block masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 5 mm thick in CM (1:3) on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:6 & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:4 & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of white cement as primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surface of ceiling and applying one coat of white wash complete all as specified & directed by Engineer-in-charge.
M & L for Preparation of old plastered surfaces of ceiling incl Complete removal of existing treatment applying two coats of white wash complete all as specified & directed by Engineer-in-charge.
M & L for Preparation of old plastered surfaces of wall incl Washing, rubbing down and stopping of distempered and painted and applying one coat of distemper oil emulsion complete all as specified & directed by Engineer-in-charge.
M&L for Preparation of old plastered or unplastered surface of wall and applying one coats of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for Preparation of old plastered surfaces incl Complete removal of existing treatment and applying Two coats of cement base paint on surfaces of walls, column, beam, chajjas etc. complete all as specified & directed by Engineer-in-charge.
M&L Preparation of old wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel (ordinary tint) (each coat) complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified & directed.
Taking down chowkhats or frame with shutters (w/o taking off shutters from the frame) n exc. 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frame with shutters (w/o taking off shutters from the frame) exc. 1.5 Sqm and n. exc 4 Sqm each complete all as specified & directed by Engineer-in-charge.
S & F, 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated all as specified & directed by Engineer-in-charge.
S & F, 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & directed by Engineer-in-charge.
S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MSD square tube etc complete all as specified & directed by Engineer-in-charge.
S&F factory made solid PVC moulded door shutter 28 to 30 mm thick (style) with 2, 4, 6 raised panel design with 2 mm moulded PVC sheet on the front face and2 mm moulded PVC sheet on back face supply and fixing in the frame at site as per specification with particle board core complete all as specified & directed by Engineer-in-charge.
S&F in repair Vitreous china wash down water closet pan (Pedestal pattern), white (EWC) with necessary P/S Trap and fixed in repairs including jet spray and seat cover complete all as specified & directed by Engineer-in-charge.
S&F in repair 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia & PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified & directed by Engineer-in-charge.
S&F in repairs 140 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drwn steel spring, fixed in floor complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes and including hacking out old broken glass of any thickness size, quality or description from metal frames complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 15mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F in repair, 15 mm bore, bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia stop valves fancy type cast copper alloy chromium plated screwed down high pressure with crown or capstan head screwed both ends for iron pipe complete all as specified and directed by Engineer-in-charge.
S & F in reapir 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or in floors or fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F in repair 110 mm bore PVC (SWR) bends/shoes any radius complete all as specified and directed by Engineer-in-charge.
S & F in reapir 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F in repair 75 mm bore PVC (SWR) bends/shoes any radius complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position including taking down old existing tank of any description complete all as specified and directed by Engineer-in-charge.
S&F Ball valves high pressure of 20 mm dia PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) omplete all as specified and directed by Engineer-in-charge.
S&F in repair vitreous china wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets omplete all as specified and directed by Engineer-in-charge.
S & F Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) omplete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-charge.
S&F, in repair, tubular towel rail aluminium anodised, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC connection pipe for WHB, cistern, gysers etc of size 15 mm dia and 450 mm long fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC down take waste water pipe for urinals of size 32 mm dia and 100 cm long fixedcomplete all as specified & directed by Engineer-in-charge.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified & directed by Engineer-in-charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed by Engineer-in-charge.
S&F, in repair, white/ black plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed by Engineer-in-charge.
S&F in repair Cast iron nahani trap of 75 mm dia with grating including jointing to waste pipe fixed in cement concrete type B 1 (1:2:4) complete all as specified & directed by Engineer-in-charge.
Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified Note : Demolition should be done by chiselling.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-charge. (Note :- Supply only water proofing compound shall be measured & paid separately).
Supply only Liquid water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L for providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application incl applying evenly bitumen tack coat primer of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces and laying over finished surface complete all as specified with the following specifiations :-
ITEM NO. 77.00 CONTD... (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm. (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm.
ITEM NO. 77.00 CONTD... Note:- APP membrane shall be laid using butane torch by torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane. (d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane
S&F pressed steel frames (size 105 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the Contractor shall deemed to inclusive of filling of pressed steel door frame with PCC (1:3:6) type C1 (using 20mm graded stone aggregate).
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as directed by Engr-in-charge.
M&L for 18/19 mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all incl dismantling boarding, any description, fixed in any position with nails complete all as specified & directed by Engineer-in-charge.
S&F mild steel cold rolled butt hinges 100mm size medium weight in any type of chowkat or frame including welding if required complete all as specified & directed by Engineer-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt plate with hasp and staple (bolt type), 300mm size and fixing in clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed by Engineer-in-charge.
S&F aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed by Engineer-in-charge.
S & F 300 mm long mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
S & F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded (Glazed steel window) complete all as specified & directed by Engineer-in-charge.
S & F Steel windows or ventilators, fixed type, with glazing bars complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc ,removal to store for safe custody for issue under schedule of credit and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /surface panel light / flood light of any description light fitting any type any watt complete all as specified & directed by Engineer-in-charge.
M& L Point wiring with 1100 volts grade PVC insulated single core sheathed FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No 92.00 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase, neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board complete all as specified & directed by Engineer-in-charge.
All as per item No 92.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 Amps complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
M&L for light/fan/bell point wiring pvc insulated unsheathed FRLS 1100 volts grade cable as per IS 694 with valid CML No with multistranded copper conductor cable of nominal cls area 1.5 sq mm each for phase ,neutral and earth drawn and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc as earth continuity conductor connected to common earth complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
a) One light point controlled by one switch
b) One ceiling/exhaust fan point controlled by one switch
(c) one bell/buzzer point controlled by one push botton.
(d) One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No 100.00 here on before but with copper conductor cable of nominal cross sectional area 2.50 sq mm for phase ,neutral & earth One 2/3 pin socket outlet 5Amps on independent board.
All as per item No 100.00 here on before but with copper conductor cable of nominal cross sectional area 4.0 sq mm for phase, neutral & earth for power socket point.
S& F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-charge.
S&F of bell push flush type 5 Amps complete all as specified & directed by Engineer-in-charge.
S&Fof bell AC single pole Ding Dong type 230 volt complete all as specified & directed by Engineer-in-charge.
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge.
S&F for sheet metal enclosure double door MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts IP 43 Protection double door with magnitic locking system complete all as specified & directed by Engineer-in-charge.
S/F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 100 A , and with SP/TP MCCB's as incoming MCCB FP 100A , 25 KA complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S&F MCB's TPN 63 Amps, 415 Volts,10 kA 'C' curve complete all as specified and directed by Engg-in-charge. Note : MCB TPN rating ICS =100% ICU
Supply and fixing MCB's single pole and neutral 63 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note :- Two runsof 10.00 Sqmm cable & one run of 10.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length)
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp as incomer complete all as specified & directed by Engineer-in-charge.
S&F bldg security light fittings Wall mounted LED light 35 Watt including bracket made out of GI pipe (light grade) of bore 40mm, 1.20 metre long made to shape and fixed outside of the building by means of 2 No FI 40x6 mm clamps with suitable size of nuts, bolts, washers and connecting with three core copper flexible cable of size 1.50 Sq mm complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4000 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and aintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per Crompton CAT PART NO Shelter . CIS -305-40-57-SL-DP-NWH or equivalent in Appx 'C' list of makes.
S & F for LED tube light fitting 20 Watt 4 Feet or 1183 mm length, IP 20 Protection, wall mounted type, Slim LED Batten with polycarbonate housingand diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 2000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified & directed by Engineer-in-charge.
S & F in repair of LED tube light fitting 10 watt tube LED Neutral worm in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning up to 3000 K , necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified & directed by Engineer-in-charge.
S & F for LED post top lantern/gate Light 20 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories complete all as specified & directed by Engineer-in-charge.
Taking down ceiling fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
Taking down exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge.
Supply and fixing of PVC insulated copper conductor 2.5 sq mm 3 core in PVC conduit medium grade in ground/surface in trench with necessary fixing arrengment and connecting items complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 128.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
S&F GI tubing light grade 20 mm dia.for earthing strip protection and including taking down existing pipe of any description complete all as specified and directed Engg-in-Charge.
M&L for Earth continuity strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with galavanised iron wire of 4 mm size complete all as specified and directed Engg-in-Charge.
Supply, lay, test and commissioning of LT UG, XLPE insulated, heavy duty, 1100 V grade of size 25 sq mm. 4 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
Surya Buildcon & Engineers
AMBEY MAA CONSTRUCTION COMPANY
Bhawani Constructions
JASOL MAA ENTERPRISES
GEMRARAMCONTRACTOR
M/S R B CONSTRUCTIONS
Paliwal Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .