Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC VILL MATIPUNG P O P S DIPHU DIST KARBI ANGLONG | NAGAON | ASSAM | 782136 | ₹1.3 Cr | L1 | Accepted-AOC L1 BIDDER AND ACCEPTED ON DT 04 SEP 2020 |
| 2 | L2₹1.7 Cr+₹41.5 L (31.1%)Rejected-Finance DEEDAR MARKET ROOM NO UB 12 POLICE BAZAR SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹1.7 Cr+₹41.5 L (31.1%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECTED DUE TO TWO CLASS BELOW |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
8 Aug 2020, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG SPREAD EAGLE FALLS SHILLONG MEGHALAYA 793011
SPECIAL REPAIR AND STRUCTURAL REHABILITATION OF TRANSIT CAMP AT GUWAHATI UNDER GE GUWAHATI
2020_MES_359576_1
8373/GUW/E8
Open Tender
Civil Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
GE GUWAHATI
₹2.2 L
Yes
7 Sept 2020
9 Jul 2020
10 Aug 2020
9 Jul 2020
8 Aug 2020
23 Jul 2020
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern as in roof covering with ridges etc and refixing including necessary screws or washers after repairing of bldg external finishing and rain & sewage pipes etc complete
S&F Pre- painted galvalume aluminum zinc coating GI based Corrugated / semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling plain or corrugated steel sheeting, any gauge, thickness complete as specified and directed.
Taking down old unserviceable 100mm bore cast iron or PVC drain pipes including fittings, jointed in cement mortar and taking out of walls or trenches in any position complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls with and including MS/PVC clamps complete all as specified and directed.
Fixing only 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls with and including new MS/PVC clamps complete all as specified and directed.
Taking down old unserviceable 150mm bore AC rain water pipe or PVC pipes including fittings, jointed in cement mortar and taking out of trenches/floor or wall in any position as specified and as directed.
S&F 150mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls with and including MS/PVC clamp complete all as specified and directed.
S&F 150 mm bore PVC (SWR) bend any radius as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as roof floors, beams, staircase landing slab chajja/sunshade etc of ) of any description and in any position including removing rubbish off the premises complete as directed.
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors including taking down of old unserviceable pipes complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls with and including MS/PVC clamps complete including taking down of old unserviceable pipes.
S&F PVC (SWR) bend any radius 110mm dia complete all as specified and directed.
PVC (SWR) bends with access door 110mm dia any radius complete all as specified & directed.
S&F 110mm bore PVC (SWR) junction, single (Single T) equal or unequal complete all as specified & directed.
S & F PVC (SWR) junction T ,single (single T ) , equal or unequal 110mm dia with access door complete all as specified & directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified & directed.
S&F in repairs, 75mm outer dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete as specified and directed.
Taking down cement plaster on brick work or concrete surfaces of any description and removal of debris complete as specified and directed
M&L for Rendering 15mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:6) on concrete surface finished fair and even without using extra cement, complete all as specified and directed.
M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed.
M&L for Preparing newly plastered surfaces of walls and applying white cement based wall care putty (minimum 1.5mm thick), complete all as specified and as directed.
M & L for rendering 15mm thick plaster in CM (1:4) on fair faces of brick work or on concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) finished fair & even without using extra cement mixed with integral liquid water proofing compound as per manufacturer instruction (for top layer only) complete all as specified and directed. Note: WPC will be measured and paid separately.
Supply only Liquid water proofing compound (ISI marked).
M&L for rendering 5 mm thick in CM 1:3 on ceiling of concrete surfaces finished fair and even without using extra cement, complete all as specified and directed.
M&L for three coats of white wash on plastered ceiling including preparation of newly plastered surfaces complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered or unplastered surfaces of walls and applying two coats of exterior acrylic emulsion paint ( Ist quality) over a coat of acrylic exterior wall primer after application of exterior grade of white cement based wall care putty (minimum 1.5 mm thickness) complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of exterior acrylic emulsion paint ( Ist quality) over a coat of acrylic exterior wall primer complete all as specified and directed.
M & L for RCC M-25 (using 20 mm graded stone aggregate as in chajjas, sun shade, beams, lintel etc complete all as specified and directed. Note : M-25 (Design mix) approved by GE for any project running shall be used as approved by GE.
Use & waste of form work to chajjas, beam, lintel flat for rough finished surfaces of concrete flat complete all as specified and directed.
M & L for TMT bars 6 mm dia and over upto and cut to length, bent to shape required including cranking and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed
S&F GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste ,securing properly all as directed and specified.
Demolition of brick work, built in cement mortar of any description and in any position including removing rubbish off the premises complete as directed.
M&L Brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete as specified and directed.
M&L Brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete including removing rubbish off the premises complete as directed.
Demolition of concrete in ground floor & paving not exceeding 15 cm thick above or below ground level complete including removing rubbish off the premises complete as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises as specified and directed.
Cleaning of blocked drain pipes (SGSW/Hume pipe) upto 150 mm bore by inserting bamboo/iron rods from manhole and removing all deposits and blockages without damaging the pipe and flushing with water after cleaning the same and disposing of the deposited sludge collected in manhole to a distance not exceeding 200m and filling the sludge in underground pits (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning filling in including sprinkling of bleaching powder at the rate @0.20Kg/Sqm and dressing of surplus soil around to disposal pits complete all as specified and as directed.
Cleaning of all the previous demolished materials all scales debris dirt etc from chajjas canopy roofs and removal to all materials from or to a distance of 10 KM from existing site complete all as directed. Note :- All useless demolished materials disposal of which is not covered in other items of repair/demolition shall only be measured in this item.
S&F in repairs, 25mm bore, GI tubing, medium grade with all fittings, fixed to walls, ceilings or laid in floors complete as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in filling under sunken floors, etc complete as specified and directed.
S&F in repair vitreous china, squatting pan, “ORISSA PATTERN” of size 580x440mm, white with integral foot rests (excluding flushing cistern and flush pipe) including ‘P’ or ‘S’ trap and all necessary connection and including provision of lime concrete bedding complete all as specified and directed.
S&F in repair vitreous china, semi pedestal pattern (Anglo Indian type) water closet white (excluding flushing cistern and flush pipe) complete all as specified and directed.
M&L non-skid, ceramic coloured tiles (first quality) 7 mm thick (Square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles laid over and including 15mm thick cement screed bed (1:4) finished even and rough complete as specified and directed.
M&L Non-skid, ceramic coloured tiles (first quality) 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles including 15mm thick, screed bed or bedding layer, in cement mortar (1:4) for laying floor tiles complete all as specified and directed.
M&L glazed ceramic coloured tiles (first quality) of size 7 to 8mm thick ( square/rectangular ) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in vertical surfaces, such as skirting, dado, etc, set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles laid over and including 10mm thick plaster in cement mortar (1:4 ) as in backing coat to receive wall tiles complete as specified and directed.
M & L PCC type C-2 1:3:6 using 40mm graded aggregate as in surface drain and channels complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L 75 mm thick Cement concrete type C 2, 1:3:6 (using 40 stone aggregate) in plinth protection, finished even and smooth without using extra cement with and including all necessary formwork and to divide the area in panels and finishing exposed edges fair and rounding or chamfered with and including filling the joints with mastic filling, complete all as specified and as directed.
S & F in repairs PVC waste pipe 32 mm bore 750mm long for basin complete. Make : Prayag/Polytuff
M&L for grubbing/uprooting of shrubs/plants/saplings like peepal, banyan etc., from the junction of sewage stacks, chajjas, parapet wall and walls of building(G+5) area of each location not exceeding 3 Sqm at any height by taking all safety measures and in strict supervision including making good disturbed surfaces with PCC type B0 1:2:4 or cement mortar 1:3 to suit the site requirement and matching existing surface with adjoining surfaces of the building and application of one coat of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutter (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and as directed .
S&F 100 mm size stainless steel butt hinges fixed with stainless steel hinge pin complete as directed.
S&F 150 mm long aluminum anodized barrel tower bolts of extruded section complete as specified and directed.
S&F 150 mm size aluminum anodized cast type handle complete as specified and directed.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet/single piece extruded PVC profiles reinforced with MS square tube fixed in opening as per specification & drawing complete as specified and directed.
M&L 30mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S tubes of 19mm for stiles & 15mm x 15mm for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC sheet/single piece extruded PVC profiles ‘C’ channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles and 5mm thick PVC sheets/single piece extruded PVC profiles for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted in the colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with PVC sheet beading and joined together with solvent cement adhesive etc. complete and fixing in the frame at site as per direction of Engr-in-Charge, manufactures instructions all as specified and directed.
S&F in repairs, 10 liters capacity, PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including bracket & flush pipe and fixing to WC complete as specified and directed.
S&F in repairs PVC connection 15mm bore 450mm long with PTMT nuts and washers on both sides complete as specified and directed.
Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling, floor etc including cleaning of tubes for re-fixing or removal to store, complete all as specified.
S&F Steel water tubes 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified.
Taking up or down 20 mm bore steel tubing with connections or fittings from wall, ceiling, floor etc including cleaning of tubes for re-fixing or removal to store, complete all as specified.
S&F Steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified.
S&F in repair white Vitreous china wash down water closet pan (pedestal pattern) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device including flush pipe and fixing bolts complete all as specified and directed .
S&F in repair vitreous china wash hand basin white flat back, size 550 x 400 mm including one No waste fitting brass 32 mm dia, Chromium plated etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed with one No PVC waste pipe 32 mm dia and 75 cm long one No 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed for iron pipe, and PVC connection 15 mm dia & 600mm long with two Nos check nut and washer complete including cutting for and pinning in ends of bracket complete all as specified and directed.
S&F in repair health faucet suitable to fixed alongwith 900mm long PVC connection including fly nut and fixed with 15mm dia MS tubes etc complete all as directed.
S&F in repair bib tap 15 mm dia chromium plated, cast copper alloy with crutch or butter fly handle screwed fancy type for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair stop valve 15 mm dia Chromium plated fancy type, high pressure with crutch or butter fly handle screwed for iron pipe or union and fixed complete all as specified and directed.
S&F in repair long shank and cup (concealed type) stop valve 15 mm dia Chromium plated fancy type, high pressure with crutch or butter fly handle screwed for iron pipe or union and fixed complete all as specified and directed.
S&F 75 mm PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Disconnecting existing tanks of capacity exceeding 1000 but not exceeding 2000 liters setting aside for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position complete all as directed.
Supply & Fixing Rotational moulded polyethene water storage tanks 2000 liter capacity with lid (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling old one complete all as directed by Engr-in- Charge
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18 to 20mm thick over and including 15 mm thick cement screed bed in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing, complete all as specified and as directed.
M&L applying two coats of water proofing coating by using super latex manufactured by pidilite industries ltd or equivalent product manufactured by Sika/ Fosroc/ Choksey chemical and cement ratio (1:4:7) or as per manufacturer's instruction suitable for sunken floor and wall complete all as directed.
Dismantling, removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached at various locations in building (G+5) by providing necessary scaffolding work and subsequently cleaning the surfaces by wire brush and air blower and removing rubbish off the premises and disposing at the dumping site approved by local authorities complete all as directed.
M&L for providing and applying a flexible expansion joint membrane minimum 150mm wide and 1mm thick, expoband one (Expoband H45) of Fosroc or equivalent over the prepared joint using a two part epoxy adhesive nitobond PC 40 of Fosroc or equivalent. The minimum tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%. The installation of the membrane should be carried out as per manufacturers specification and as directed by the Engr-in-Charge.
M&L for drilling suitable holes in RCC slab/wall/column/beams to a depth as directed for anchoring steel reinforcement bars including washing with water, inserting lokfix ‘E’ of Fosroc or equivalent in the holes at various locations in G+5 building complete all as per manufacturers specification and as directed. Note:- The reinforcement shall be measured and paid seperately.
M&L for cleaning the exposed reinforcement bars thoroughly with wire brushes and emery cloth and application of alkaline rust remover Sika rust off 100 (Sika)/Reebaklens RR of Fosroc and application of two coats of anti corrosive epoxy Zinc rich Friazinc R (SIKA) or equivalent product like NITOZINC primer of Fosroc on rebars to passivate the corrosion activity complete all as per manufacture’s direction and as specified at various locations in G+5 building. (Note:- The complete surface area of length of rusted reinforcement bar shall be measured and paid irrespective of the degree of rusting of the bar.)
M&L for applying a bond coat of epoxy resin based Sikadur-32 LP (SIKA) or equivalent product like NITO Bond EP of FOSROC or Dr Fixit adhesive @ 0.40 liter per sqm on the cleaned concrete or plastered surfaces by brushes at various locations in G+5 building complete all as per manufacturers specification and as directed.
M&L for providing and applying a two component structural grade polymer modified reinstatement mortar Fosroc Renderoc S2 or equivalent product of SIKA upto a thickness of 15mm over a coat of epoxy resin bonding agent Nitobond EP. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in 1 day & 45 N/mm2 in 28 days with Flexural strength 8N/mm2 in 28 days. Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. In addition to this percentage of water absorption should be 0.45 after 24hrs in immersion test at various locations in G+5 building complete all as per manufacturers specification and as directed.[Note: The testing charges of Accelerated electro chemical chloride ion diffusion test shall be deemed to be included in the rate quoted]
M&L for supply, mixing and placement of Micro-concrete cement based prepacked single component, chloride free, sulphate free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion of Sika Rep Microcrete-4 or renderoc-RG of Fosroc in required thickness as per manufacturers instructions and all as directed. Compressive strength (ASTM C109,7cm cube) of 35MPa at 28 Days, including application of curing compound concure WB manufactured by Fosroc or equivalent at various locations in G+5 building including necessary form work complete all as per manufacturers specification and as directed.
M&L for providing and injecting epoxy grout through 8 mm MS Nozzles using low Viscosity injection resin, Sikadur 53 UF (SIKA) or CONbextra EP-10 of Fosroc, two part, solvent free, low Viscosity, moisture insensitive, injection liquid with a positive displacement grout pump and grouting to be started from lowest level and to proceed towards upper level and to be continued at any Nozzle till refusal/ till oozes out from adjacent nozzle or same nozzle. All nozzles shall be removed after 01 day of completion of grouting and hole point shall be repaired by Nitobond PC40 of Fosroc at various locations in G+5 building complete all as per manufacturers specification and as directed.
M&L for providing grouting in RCC walls and slabs by drilling holes @300mm c/c upto half of the wall depth in zigzag manner using a drill machine and fixing a nozzle of 20mm dia, for injecting cement slurry admixed with non shrink admixture using fosroc CEBAX 100 @ 225 gms per bag of cement or equivalent product till the refusal of injected grout material (grouting operation pressure shall be in between 2 to 4Kg per sq cm) followed by cutting the exposed nozzle so as to make the wall/slab free from the grouting pipes and to seal the gap with polymer modified mortar as specified and directed by the Engr-in-Charge complete.
M&L for filling the gap between pipe and concrete/brick surface to arrest seepage through pipe penetration points using free flow, ready to use, Sika Rep Microcrete 4 (SIKA)/Renderoc RG of Fosroc or equivalent and sealing the mouth of annual gap in 10 mm x 10 mm with moisture insensitive, two component, epoxy based Sikagard 694FI of Sika or Nitobond PC-40 of Fosroc as gasket and making good surface to match existing surrounding surface at various locations in G+5 building complete all as per manufacturers specification and as directed.
M&L for substrate preparation by removing all existing loose materials and layers, all dust and dirt particles, preparing and cleaning the concrete surface, repairing cracks with polymer modified mortar and making a coving of 75 mm x 75 mm at the parapet wall and concrete roof junction using polymer modified concrete, cement, sand and 6 mm size aggregate in 1:2:4 mix duly admixed with Sika Raintite L (SIKA)/NITOBOND SBR latex of Fosroc chemicals (10% weight of cement) on a primer coat of Sika Raintite L (1 part ST RI :2 part cement) or equivalent of Fosroc complete all as specified and as directed.
M & L for providing and applying three coats of brushbond roofguard manufactured by fosroc or equivalent product of SIKA, single component acrylic polymer modified reinforced high build water proofing compound after priming on the roofs, to get a minimum dry thickness of 1mm as per manufacturers specification. No toping required over the grading. The cured membrane should exhibit the tensile strength of 1.1 Mpa as per ASTM D412 with elongation 100% as ASTM D12, with very low penetration to rapid chloride as per ASTM C 1202-03, with pull off adhesion 0.92 complete all as specified and as directed.
M & L for providing mixing and applying two coats of brushbond RFX(Fosroc) of acrylic polymer modified cementations waterproof coating, supplied as a liquid polymer component and a cementicious powder component, which shall be mixed as per manufacture's instructions and applied over prepared concrete surface strictly maintaining the coverage specified by the manufacturer. The applied waterproofing coating should have a weight loss of less than 1gm when tested for abrasion resistance according to ASTM-D4060, Pull off adhesion of greater than 1N/mm2 as per ASTM-D4541 and static crack Accommodation of 1mm according to ASTM C-836 complete all as directed. Notes for Ser Item Nos 76 to 89 :- (a) The work under these items shall be got executed through authorized applicator of manufacturer and certificate to this effect shall be produced. (b) The purchase vouchers of all materials involved shall be produced before claiming payment and the materials shall be procured only from authorized dealers of the manufacturers. Payment shall only be released after submission of purchase vouchers.
Providing and fixing Powder coated aluminum (minimum thickness of powder coating 50 micron) work for frames of doors/windows/ventilators and partitions with extruded built up standard sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, including making provision for fixing of fittings wherever required including the cost of other required fittings etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, C.P.brass/stainless steel screws, all complete as per the directions of Engineer-in-charge. (Notes:- 1. The weight shall be of all aluminum components and fittings except the gaskets. 2. Glazing, wire mesh and paneling to be paid for separately and all other fittings shall be deemed to be included in the rate quoted.)
M & L for water proofing treatment to RCC roof slab comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. and removing debris outside premises of building or as directed. (ii) 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate using WPC @ 200ML per bag of cement or as per manufacturers instructions, as in leveling course as in roof padding/slope correction layer finished even and fair complete all as specified and directed. (iii) Cleaning of plastered / concrete padding over roof surface and applying one coat of cold bituminous primer @ 0.25 liter /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.
M & L for water proofing treatment to vertical surfaces of parapets, RCC roof slab fascia etc comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. and removing debris outside premises of building or as directed. (ii) Applying one coat of cold bituminous primer @ 0.25 liter /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.
M&L for applying one coat of bitumen based UV reflective and water proofing paint with aluminum finish on APP membrane after preparation of surfaces complete
M&L for 22 mm thick plain cement concrete tiles (confirming to IS) of size 250x250mm or 300mmx300mm laid over a bedding layer of 15mm screed in cement mortar 1:4 & jointing with neat cement slurry joints shall be 4mm wide and sealed with 2mm deep epoxy compound complete all specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and scantling and removing dismantled materials from site complete all as directed.
S & F Solid PVC wall lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4Sqm each complete as directed.
Taking down shutter exceeding 1 Sqm and not exceeding 2 sqm each complete as directed.
S&F Flush shutters 30mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete as directed.
S&F Sheet glass ordinary quality of 4mm thick and glazing with oil putty in square not exceeding 0.5 sqm in each pane including all glazing clips, rubber gasket complete as per the directions of Engineer-in-charge.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples ,complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint (1st quality) over priming coat of pink primer complete as specified and directed.
S&F 100mm size Butt hinges, medium weight, cold rolled mild steel complete.
M&L 300mm long, Aluminum alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast, cast or extruded section and fixing bolts and sliding bolts complete as specified and directed.
M&L for complete removal of existing treatment of old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after application of white cement based wall care putty (minimum 1.5 mm thickness) complete all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of walls and applying one coat of oil bound distemper finishing all as specified and directed by Engr-in-Charge.
M&L preparation of old plastered or unplastered surfaces on ceiling and applying one coat of oil bound distemper finishing all as specified and directed by Engr-in-Charge.
Cutting chases in brick walls not exceeding 10cm girth for concealed water tubing and making good complete as per existing surrounding all as directed by Engr-in-Charge.
S&F Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails braces, wind ties, clits, hold fasts etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing compete as required conforming to Fe-290 Gde E-165 as specified and directed.
M&L Preparation of new steel and iron surfaces of any description, exceeding 10 cm width or girth and applying two coats of synthetic enamel paint (Ist grde quality) over a coat of red oxide, zinc chrome primer complete as specified and directed.
S&F in repair 20mm dia Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S&F in repair PTMT shower rose with or without joints including fixing to pipe or union completed all as specified and directed.
S&F in repair tubular towel rail, 20mm dia, D type, brass chromium plated, 60cm long between flanges complete all as specified and directed.
S&F in repair soap dish of brass, chromium plated approximate size 160x160x90 mm fixed to plugs with CP, brass screws complete all as specified and directed.
S & F Vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe) including urinal spreader of PTMT any colour for fixing with 15mm dia pipe(Minimum weight 60gms) and including waste pipe complete all as specified and directed.
S&F Sheet glass, ordinary quality of 5.5mm thick and glazing with oil putty in square exceeding 0.5 sq. m in each pane including all glazing clips, rubber gasket complete all as specified and directed
M&L Prelaminated particle board, 12mm thick, interior grade, bonded with phenol formaldehyde synthetic resin, confirming to IS: 12823 grade-I, prelaminated both sides with decorative choice laminations fixed with screws/nails to aluminum/timber framework etc, complete all as specified and directed. Make : Greenply Industries Ltd (Ply & Board division)/Kitply/Century/Archid Ply/National Plywood Inds Pvt. Ltd
S&F aluminum die cast body door closer hydraulically regulated, designation No-3,universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint (1st quality) complete all as specified and directed.
S&F LDPE pipe 40mm bore as in waste pipe fixed complete to walls, ceilings & floors after taking down of existing complete all as specified and directed.
Taking down carefully old unserviceable copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, sunken type box etc. and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for modular fittings with 1.5 Sqmm (nominal area) PVC insulated1100 volts grade, multistranded, copper conductor, single core, unsheathed cables (FRLS quality) drawn through and including PVC conduits of suitable size but not less than 20 mm dia (medium grade) with all fittings and accessories concealed in walls/ceiling etc including cutting chases for conduits and sinking for boxes and making good to disturbed surfaces including MS powder coated terminal box, frame with cover plate suitable for modular fittings including PVC insulated and unsheathed, single core, multi-stranded, copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light point / fan point controlled by one 5 Amps one way switch complete as specified and directed. Note : Quoted rate shall be inclusive for necessary chasing and cutting and making good .
All as per item No 125.00 above but for one 3 pin socket outlet 5 Amps, on independent board.
All as per item No 125.00 above but for one 3 pin socket outlet 5 Amps on same board alongwith other suitable switches.
All as per item No 125.00 above but one light point controlled by 02, two way switch, on independent board.
All as per item No 125.00 above but one call bell point controlled by one modular bell push switch.
All as per item No 125.00 here-in-before but using 4.00 sqmm PVC FRLS insulated copper conductor wire (earth wire also 4.00 Sqmm PVC FRLS copper conductor ) for connecting 15A socket on independent board complete all as specified/directed.
Supply and fixing of modular switch, one way 6 amps, 1 module 240 Volts complete all as specified/directed. Make : Legrand/L&T /Indo asian
Supply and fixing of modular switch two way 6 amps 1 module 240 Volts complete all as specified/directed. Make : Legrand/L&T /Indo asian
Supply and fixing of modular socket outlet 2/3 pin 6 Amps 240 volts 2 module complete all as specified/ directed. Make : Legrand/L&T /Indo asian
Supply & fixing of modular switch one way 16 Amps 1 module 240 Volts complete all as specified / directed. Make : Legrand/L&T /Indo asian
Supply and fixing of modular socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply & Fixing of modular type ceiling fan regulator step type ,2 module, 120 W complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply & Fixing of modular type bell push 6 amps ,1 module complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply and fixing of bell electric, ding dong type 240 Volts, single pole complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply and fixing of modular TV Co-Axial socket - 1 module complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply and fixing of modular Telephone socket double RJ11 - 1 module complete all as specified and directed. Make : Legrand/L&T /Indo asian
Supply and fixing of ceiling rose 3 Phase PVC/Polycarbonate, isolated body complete all as specified/directed.
Supply and fixing Bulb angular/batten holder PVC/Polycarbonate suitable for batten fittings including one No LED Lamp of 12 W (minimum) of Havells/Philips/Crompton Make, complete all as specified/directed.
Supply and fixing of modular blanking plate for 1 module complete all as specified and directed. Make : Legrand/L&T /Indo asian
S & F ventilating air fan 250 mm sweep, 230 volts, speed 1200 RPM, single phase, including making holes suitable for fixing fan and making good disturbed surface and connection complete s specified directed. Havells/Usha/bajaj
Supply and fixing LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. Make : Cat Part No: Bajaj Batten 112181 Batten for LED TUBE LIGHT fitting BLRB- DB 118. Bajaj Tube rod No BLRB-18 Watt CWc XE (112753) or Havells Cat Part No: REGALBATTENT5UPTO1X18WDSBSWH for batten and TITANIANEO1213T8SSTL18WLED865SPC for tube light or its equivalent in Philips
Supply and Fixing 10 W LED polycarbonate tubelight integrated LED Channel , with surface or wall mounted LED fitting and with electronic driver , bipin holders, connector block , etc complete with all accessories internally prewired and including connecting up with twisted copper conductor cable complete all as specified. Make: Havells E-Lite Pride plus Neo, Cat Part No. LHEXACP7IN1W010 or its equivalent in Philips/Bajaj.
Supply and Fixing Recess mounted 2 X 2 , 36 W LED flat panel fittings decorative ,IP-20 , High quality polycarbonate opal diffuser for glare free uniform light distribution, fixed to the powder coated MS frame , with electronic constant current Driver etc complete with all accessories internally prewired and including connecting up with 2 core twisted copper conductor complete all as specified. Make: Havells , Cat part no. VENUSNEOHE2X2R18-42WLED857MODUGR<19 or its equivalent in Philips/Bajaj.
Supply and Fixing Recess mounted 1 X 1 , 15 W LED flat panel fittings decorative ,IP-20 , High quality polycarbonate opal diffuser for glare free uniform light distribution, fixed to the powder coated MS frame , with electronic constant current Driver etc complete with all accessories internally prewired and including connecting up with 2 core twisted copper conductor complete all as specified (Make: Havells (cat part no. PLUTO1X1PLR15WLED857S or its equivalent in Philips/Bajaj.
S &F Energy saving new generation 10W LED IP65 bulkhead luminaries with opal diffuser complete set with lamp and making connections with twisted unsheathed PVC copper cable of suitable size complete as directed. Make: Havells cate No RUGBYNEOFT10WLED860SSYMTOPC or its equivalent in Philips/Bajaj.
Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing capping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessories and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi stranded copper conductor of size 6 Sqmm as earth wire (green in colour) run throughput conduit and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note : Two run cable, one run earth wire and one run PVC casing capping will be measured as one length.
Material & labour for Sub main wiring with four runs of single core 10 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing capping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessories and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi stranded copper conductor of size 6 Sqmm as earth wire (green in colour) run throughput conduit and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note : Four runs cable, one run earth wire and one run PVC casing capping will be measured as one length.
S & F TPN Vertical loadline DB 8 way double door, fitted with Busbar neutral links blanking plates without MCCB, 415 volts, concealed in walls/ceiling etc including cutting chases for sinking for boxes and making good to disturbed surfaces complete as specified and directed Make: Havells cat No. DHDLVDRWGOFO08 or equivalent in L & T/Legrand /Schneider.
S & F TPN Vertical loadline DB 4 way double door, fitted with Busbar neutral links blanking plates without MCCB, 415 volts, concealed in walls/ceiling etc including cutting chases for sinking for boxes and making good to disturbed surfaces complete as specified and directed ( Make: Havells cat No. DHDLVDRWGOFO04 or equivalent in L & T/Legrand /Schneider)
S & F sheet metal enclosure ( DB) for housing MCBs 8 way SPN with 200 AMPs rated bus bar 240 volts double door concealed in walls/ceiling etc including cutting chases for sinking for boxes and making good to disturbed surface complete as specified and directed. Make Havells Cat No. DHDPSHODPW08 or equivalent model in Legrand/Schneider/L&T.
S & F sheet metal enclosure ( DB) for housing MCBs 6 way SPN with 200 AMPs rated bus bar 240 volts double door concealed in walls/ceiling etc including cutting chases for sinking for boxes and making good to disturbed surface complete as specified and directed. Make Havells Cat No. DHDPSHODPW06 or equivalent model in Legrand/Schneider/L&T.
S&F MCCB, FP, 125 Amp,16 kA breaking Capacity, 415 Volts fixed thermal and fixed magnetic complete as specified and directed. Make : Havells Cat No IHLGNF0125 or equivalent model in Legrand /Schneider/L&T.
S&F , MCB DP 63 Amps 240 volts complete as specified and directed. Make: Havells Cat No. DHMGCDPF063 or equivalent model in Legrand/Schneider/L&T.
S&F , MCB DP 6 to 32 Amps 240 volts complete as specified and directed. Make: Havells Cat No. DHMGCDPF006-32 or equivalent model in Legrand/Schneider/L&T
S&F, MCB SP 6 to 32 Amps 240 volts complete as specified and directed. Make: Havells Cat No. DHMGCSPF006-32 or equivalent model in Legrand/Schneider/L&T.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized strip 25 x4 mm (upto 7.50m length)as earthing lead by means of nuts, bolts and washers of galvanized iron and earth lead protected by galvanized iron pipe 32 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanized (light grade) for watering, charcoal and salt in alternate layers including necessary execution and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking down old one complete all as specified and directed.
Taking down LT Panel mounted on wall with the help of wall fastener carefully on to some insulated support structure placed nearby and also extending the sub main wiring ( originating from LT panel to TPN DBs ) by making necessary arrangements such so as to ensure continuous power supply by LT Panel and refixing the same LT panel on to its original location complete including nuts , bolts or wall fastener etc. and making good disturbed surfaces of walls, floors etc, complete all as required and painting panel with 2 coats of Flint Gray as directed and specified by Engr-in-Charge.
Taking down including cutting Cable tray (carrying XLPE Cable , grouted to wall/ Pillar with the help of nuts and bolts) carefully at a safe distance by making necessary arrangements such as to ensure continuous power supply by LT Panel through Cable and refixing the same Cable tray along with Cable on to its original location complete including nuts , bolts or wall fastener etc. and making good disturbed surfaces of walls, floors etc, complete all as required and painting Cable tray with 2 coats of Flint Gray as directed and specified by Engr-in-Charge.
Taking down including cutting 100/150 mm ERW MS pipe firefighting pipe ( fixed to wall/ Pillar/floor/ roof with the help of MS angle Iron) carefully at placing at a safe distance by making necessary arrangements and refixing the same MS ERW Pipe on to its original location complete including nuts , bolts or wall fastener or MS able iron etc. and making good disturbed surfaces of walls, floors etc, and painting pipe complete all as required and as directed and specified by Engr-in-Charge.
S & F metal distribution box with clad plug and socket and including DP-MCB control 3 pin & earth plug with socket , 32 A, 240 Volts universal type complete with one MCB 32 A, 240 volt all as specified. Make :- Cat No DHDPBDP032 of Havells or equivalent model in Legrand/Schneider/L&T.
S & F metal distribution box with clad plug and socket and including DP-MCB control 3 pin & earth plug with socket , 16 A, 240 Volts universal type complete with one MCB 16 A 240 volt all as specified. Make :- Cat no DHDPBDP016 of Havells or equivalent model in Legrand/Schneider/L&T.
H K Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .