| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L1 | Accepted-AOC Accepted being lowest on 09 Mar 2021 | |
| 2 | L2₹21.5 L+₹9,249.60 (0.43%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹21.7 L+₹23,860.60 (1.11%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
27 Feb 2021, 6:00 pmClosed
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Special repairs to ORs bathroom in Bldg No. T-4 and Bldg No. P-03 under AGE B/R (M) at Faridkot Mil Stn
2021_MES_417405_1
GE FRD-73/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹48,000
Yes
16 Mar 2021
30 Jan 2021
1 Mar 2021
30 Jan 2021
27 Feb 2021
13 Feb 2021
Amount
Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each including cutting holes of appropriate size in brick walls/ concrete surfaces for insertion of PCC block of hold fasts complete all as specified & directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.50 Sqm but not exceeding 4.0 Sqm each including cutting holes of appropriate size in brick walls/ concrete surfaces for insertion of PCC block of hold fasts complete all as specified and directed by Engineer-in- charge.
M&L for pressed steel frames(1.25mm thick sheet) for door with one or more rebates including necessary fixing arrangement such as lugs, hinges, lock strike plate etc size of frame 125 mm x 60 mm incl one shop coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note : Hinges will be measured & paid separately under relevant item of BOQ.
M&L for framed work such as grills,gratings, cooler stand, ladders etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; shouldered with steel windows / ventilators frame; railings; framework of water tanks and similar work conforming to (Fe.290.Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick factory made 2nd class hard wood plain framed panel shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering both faces. The size of rail and style shall be as per IS:1003 (Part-I), klin seasoned and chemically presuure treated complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick, glazed and skeleton shutter of 2nd class hard wood open rebated and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8.24 (a) and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsom.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F box type mild steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or with wooden beads(supplied along with shutters) in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-inCharge.
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer in Charge.
S&F solid wood moulded grain printed PVC door frame of size 50x95mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube edges shall be printed to match printed sheet in opening as per schedule complete all as specified & directed by Engineer-in-Charge.
S&F Factory made solid PVC door shutter 30mm thick (style) WOOD GRAIN PRINTED consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC "C"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face to be fitted in the MS frame welded/ sealed to the style & rail with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed by Engineer-in-Charge.
Supply & fix Mild Steel medium weight colled rolled (ISI marked) butt hinges 100 mm long complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long dia aluminium anodized handles cast type, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 150mm long dia aluminium anodized tower bolts extruded section, fixed with steel screws complete as specified & directed by Engineer-in-charge.
S&F 250 mm long aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) not less than 12 mm dia and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- charge.
S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
S&F 140 mm long cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer in Charge.
M&L for preparation of new wooden or wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-0 using 12.5mm graded stone agg a in back filling of pressed steel frames, bed blocks, coping, fixing of hold fast blocks etc including necessary form work complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete as in overhead tanks (upto height of 20mtrs), roofs, floors (other than ground floors), beams, staircases, including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete type A-1, 1:1.5:3 using 20 mm graded crushed stone aggregate as in slab supported on walls, beams and columns in floor, roof, landings, deck slab and in shelves complete all as specified and directed by Engineer in Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed by Engr-In-Charge.
Form work to sides and soffits of floor or roof beams, beam haunching, girders, lintels, cantilevers, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed by Engineer in Charge.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs not exceeding 200mm thick horizontal or sloping complete all as specified and directed by Engr-In-Charge.
M&L for TMT bars 10mm dia and over cut to length bent to shape as required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr-In-Charge.
S&F MS TMT Bars of 6mm to 8mm dia,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer in Charge
Dismantling of timber scantling 40 sq cm and over in section and in any position unframed work complete all as specified and directed by Engineer-in-Charge.
S and F 2nd class soft wood in scantling timer fixed clean swan complete all as specified and directed by Engineer in Charge.
All as per item No 32 above but except timber complete all as specified and directed by Engineer in Charge.
Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering complete all as specified and directed by Engineer-in-Charge.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing 50 mm thick cement concrete (1:3:6) type C2 using 20mm graded aggregate as in plinth protection, foot path, drains surfaces even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
S & F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but n.exc 0.18 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed in cement mortar (1:4) complete all as specified and directed by Engineer in Charge.
S&F coloured Glazed ceramic tiles (light colour as approved) in vertical surface such as skirting/dados of size 450x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement with pigment to match over and including 15mm thick rendering in cement mortar 1:4 on brick or concrete surface complete all as specified and directed by Engineer in Charge.
Taking down cement plaster on brick or stone wall etc including raking out of joints, hacking for keys and scrubbing down with water etc and removal of debris upto a distance upto 50m complete all as specified and directed by Engr-In-Charge.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 10 mm thick on ceiling surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for repairs to RCC fillet beams in ceiling with cement mortar 1:3 over applying a coat of neat cement slurry @ 3Kg/Sqm and applying two coat of white wash including taking down old plaster complete all as specified & directed by Engineer-in-Charge.
M&L Preparation of new surfaces plastered of walls and applying two coats of white wash on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of old surfaces plastered of walls and applying two coats of white wash on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of new surfaces plastered of ceiling and applying two coats of white wash on ceiling complete all as specified and directed by Engr -in - charge.
M&L Preparation of old surfaces plastered of ceiling and applying two coats of white wash on ceiling complete all as specified and directed by Engr -in - charge.
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engr -in - charge.
M & L for complete removal of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spots and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer in Charge. Note : Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins,arches & pillars etc of any description and in any position complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with fly ash bricks sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 55 here-in-before but except bricks complete all as specified and directed by Engineer in Charge
Taking up or down existing galvanised steel water tubing (GI pipe) 15 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 25 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
S&F mild steel water tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per Srl item No 60 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S&F mild steel water tubes of size 20mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per Srl item No 62 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S&F mild steel water tubes of size 25mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 2000 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 25 mm bore GI pipe including dismantling of old water tank complete all as specified and directed by Engineer-in-Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 25 mm dia of pipe complete all as specified and directed by Engineer in Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 20 mm dia of pipe complete all as specified and directed by Engineer in Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 15 mm dia of pipe complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm fancy type chromium plated Angle valve/stop valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15mm bib taps, long body, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15mm bore pillar cocks, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down, high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
Supply and fixing vitreous China squatting pan Orissa pattern, size 580 x 440mm white / coloured with integral foot rest including flush pipe and connection to 100 mm dia "P" trap and to flushing pipe, anti syphonage pipe with WC including necessary lime concrete including 10 ltr PVC valveless syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets etc complete.all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash down water closet pan (pedestel pattern/EWC/longpan) white in colour with fixing bolts and flush pipe including 10 ltr capacity PVC valveless syphonic action type, flushing cistern low level white with inlet ball valve float and handle including brackets, PTMT health faucet including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC low level flushing cistern white 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and 15mm bore PVC connection complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china ware glazed wash hand basin white, flat back of size 550mm x 400mm including CI brackets, CP brass waste coupling with rubber washer and galvanized mild steel waste pipe 32mm bore complete all as specified and directed by Engr-In-Charge.
S&F in repair Vitreous china bowl half Urinal, flatback, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe, flush pipe and waste pipe including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe and half turn valve 15mm bore connection to drain etc. complete all as specified and directed by Engineer in Charge.
S&F in repair PVC Connections 15 mm size with PTMT nuts of length 450 mm long complete all as specified & directed by Engineer-in-charge.
S & F in repair Swivel Shower to PTMT any colour for fixing 15mm pipe (minimum weight 40gms) with shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT complete all as specified and directed by Engineer in Charge.
S&F in repair Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed by Engineer-in-Charge.
S&F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer in Charge.
S&F cast iron or mild steel peg set 175mm to 250mm with hooks fixed to wall complete all as specified and directed by Engineer in Charge.
Dismantling CI/PVC 75mm/100mm /110mm bore pipes including fittings jointed in cement mortar and taking out from below or above GL or laid in floos or fixed to walls complete all as specified & directed by Engineer-in- charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore PVC(SWR) bends (any radius), diminishing pieces or tapers ( larger bore measured) laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in-charge .
S&F 100mm bore cast iron sand cast soil, waste and spun pipe in any length with or without ears laid in trenches or in floors/walls with cement joints and provision of required number flat iron clamps of required size complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore cast iron sand cast soil, waste and spun pipe in any length with or without ears laid in trenches or in floors/walls with cement joints and provision of required number flat iron clamps of required size complete all as specified and directed by Engineer-in-charge.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
M&L in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1, 1:2:4 complete all as specified and directed by Engineer in Charge.
S&F Cast iron branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore cast iron branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F cast iron vent cowl 75mm dia suitable for 75 mm bore pipe complete all as specified and directed by Engineer in Charge.
M & L for water proofing treatment to RCC sunken slab as specifiied below and directed by Engr-In-Charge:- 1.Rendering 15 mm thick in CM 1:3 using WPC on raised vertical surface. 2. Cleaning surface with wire brush/coir brush, removing loose material like dust particles, dirt etc. 3. Creating fillet covering of 50x50 mm with Polymer modified mortar on the juction of slab and wall. 4. Apply first coat of two component modified polymer coating on the horizontal and vertical surface (upto ht. as required). 5. Provision of glass fibre mesh of 2mmx2mm immediately on above coating. 6. Apply second coating of two component modified polymer coating after 72 hrs (upto ht. as required) 7. Laying concrete 1:4:8 over the coating as per requirement. 8. Joining the sanitary pipes with the water proofing tape having bridging ability of more than 1.5mm 9. Filling the gap between wall opening and sanitary pipe with non shrink cementious grout. 10. complete the treatment to be carried out by authorised applicator of water proofing manufacturer ; Make ;. Dr . Fixit/Fosroc/BASF /STP Note :- (i) The treatment shall be carried out as per the manufactures instructions and as directed by the Engineer-in-Charge .(ii) The plan area of floor shall be considered for payment .(iii) WPC shall be measured and paid seperately.
M&L for Roof treatment to RCC roof as specified below as directed :- (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet, surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, dmanged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Apllying one coat of prime seal / Epoxy Primer/ Shaili Urethane BTD white diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg/Sqm (0.20 Kg BTD + 0.20 Kg water) (d) Laying polyster reinforced fiber net / 50gsm Geotextile mesh upto 300mm on walls. (e) Applying three coat of Hydro Shield PUD micro fibre reinforced UV resistent polyurethane (solid content 68%) / Damp proof ultra UV stable fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers (Solid content 55%) / Smart care PU magnum elastomeric water proofing coating based on hydrophobic plyuethane (Solid content 85%) / Single component elastomeric Liquid Membrane Shali Urethane BTD white/ coloured (Elongation 400% + 50, Solid contents > 80% & Specific gravity @ 30 OC 1.5 + 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush / roller upto 300mm on walls. (f) The complete treatment to be carried out by authorised applicator of water proofing manufacturer. Make : Dr Fixit/ Asian/ STP Limited Note (i) The treatment shall be carried out as per the manufacturer's instructions, and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment.
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified & directed by Engr-In-Charge. (Payment for providing grooves shall be made separately).
M & L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in chajjas complete all as specified and directed by Engr-In-Charge.
Form work to chajjas, troughs and similar items including edges complete all as specified and directed by Engineer in Charge.
S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 1000 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, including dismantling of old water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 500 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, including dismantling of old water tank complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10 mm thick in cement plaster 1:4 with WPC on roof finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in roof any thickness including plastering and leaping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-Charge.
M & L for plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in roof complete all as specified and directed by Engineer-in-Charge.
M & L 40mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) with WPC (Conforming to IS : 2645-2003) in roof complete all as specified and directed by Engineer in Charge. Note : WPC shall be measured and paid separately.
Supply only Liquid water proofing compound complete all as specified and directed by Engineer in Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, sockets, ceiling roses, pendent holders, call bells, light fittings any type, regulators etc and making good to disturbed area matching the colour with the existing surfaces complete all as specified and directed by Engineer-in-Charge. Note : Rate for making good shall be deemed to be included in above item rate.
Taking down old unserviceable main switches, DB TPN / SPN and making good to the disturbed wall complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable sub main wiring any size any run with earthing cable and making good to the disturbed area complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with ISI marked 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade FRLS with multistranded copper conductor drawn through concealed/surface in wall / roof/ ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit suitable size with all acessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulators etc covered with 2.8mm thick plastic laminate Hylem top cover of required colour fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 Sqmm copper conductor as earth continuity to connect common earth dolly for One light point/fan point/exhaust fan point /call bell point to be controlled by one number one way switch complete all as specified and directed by Engineer in Charge.
All as per item No 111 here in before but one light point controlled by two numbers two way swtiches complete all as specified and directed by Engineer in Charge.
All as per item No 111 here in before but one three pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed by Engineer in Charge.
All as per item No 111 here in before but one 3 pin, 5A switch socket outlet point on independent board complete all as specified and directed by Engineer in Charge.
All as per Srl item No. 111 here-in-before but with 2.5 sqmm cable for 1 No. 16 Amps switch socket outlet point on Independent board including 2.5sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer in Charge.
S&F in repalcement PVC Lamp holder suitable for LED Lamp 5 to 20 watts bulb with bakalite 20mm back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F LED bulb 1 x 10 watt Lamp having luminous efficiency warranty 2 years complete all as specified and directed by Engineer in Charge.
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge. Make: Bajaj cat No.BCLSB 18W LED or Havells/Phillips
S&F complete set of LED mirror light fitting 1 x 12 W to 20 W, 230 V, including LED lamp with driver complete suitable for fixation on wall with body retrofit corrosion resistant superior finish and without any cracks through holes with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size as per specification & directed by Engineer-in-Charge.
S&F complete set of LED tube light fitting 1 x 9 /10 W, 230 V, surface/wall mounted decorative luminaries with high level of durability with high impact resistant and protection with confortable soft lighting with all accessories pre wired and including connections up with twin core twisted fleible copper conductor cable with suitable size as per specification and & directed by Engineer-in-Charge.
M &L in replacement of 1x10 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover,with specially designed gasket, lamp holder etc with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V,50HZ complete all as specified and directed by Engineer in Charge.
S&F ceiling rose three phase PVC polycarbonate isolated body with bakalite 20mm back plate complete all as specified and directed by Engineer-in-Charge.
S&F sub main wiring with two runs of single core PVC FRLS sheathed insulated copper cable of 6 sqmm size, multi stranded 1100 volts grade with PVC insulated FRLS copper wire 6sqmm for continous earth wire drawin into existing concealed conduit complete all as specified and directed by Engineer-in-Charge. Note ;- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in existing conduit with accessories shall be measured as one length)
S&F sub main wiring with two runs of single core PVC FRLS sheathed insulated copper cable of 10 sqmm size, multi stranded 1100 volts grade with PVC insulated FRLS copper wire 6sqmm for continous earth wire drawin into existing concealed conduit complete all as specified and directed by Engineer-in-Charge. Note ;- Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in existing conduit with accessories shall be measured as one length)
S&F switch Piano type single pole one way 5/6 Amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F socket two in one, 5 Pin 5 Amps 230 Volt AC supply, complete all as specified and directed by Engineer in Charge.
S&F switch piano flush type single pole one way 15/16 Amps, 230 volts on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.(Note:-Sheet top cover included in point wiring)
S&F switch Piano type single pole two way 5/6 Amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F socket two in one, 5 Pin 15/16 Amps 230 Volt AC supply, complete all as specified and directed by Engineer in Charge.
S&F DB double door of sheet metal TPN 4 way with 440 Volts with 200 Amps rated bus bar for provn of 63 /100 Amps MCCB complete all as specified & directed by Engineer-in-Charge.
S&F MCB distribution board double door of sheet metal single pole and neutral 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 16 KA including taking down old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
S&F MCB single Pole 230 Volts 32 Amp C Series with breaking capacity 10 KA including taking down old unserviceable MCB complete all as specified and directed by Engineer in Charge.
S&F MCB SPN 230 Volts 32 Amp C Series with breaking capacity 10 KA including taking down old unserviceable MCB complete all as specified and directed by Engineer in Charge.
S&F MCB SPN 230 Volts 63 Amp C Series with breaking capacity 10 KA including taking down old unserviceable MCB complete all as specified and directed by Engineer in Charge.
M & L Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C2 using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion complete all as specified and directed by Engineer in Charge. Note : The unit rate including earthing lead & protection pipe upto 7.5 meter from top to earth plate.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out including baling/pumping /dewatering(if required) of water complete all as specified and directed by Engr-In-Charge.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-In-Charge.
Removing of surplus soil not exceeding 200 m and deposited where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by Engr-In-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supply and lay Brick tiles; common burnt clay building bricks sub-class 'B' for standard size laid in trenches of across the cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 (Part-I, 1988) cross sectional area 16 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc inlcuding taking up defective underground cable complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
Supply, fixing and testing LED street light fitting of 25 Watt fitted on 4 to 9 meter high octagonal pole 9 & 11 meter PCC/Swan neck pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including GI pipe bracket made out of 32mm bore pipe. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided upto 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should also have high voltage with standing capacity upto 300V, AC double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Cat No. 169821 BCLST25WLED or equivelant in Crompron/ Havells/Halonix/Philips Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
M&L for MS clamp fabricated from MS flat of size 40mmx3mm including nuts, bolts, washers, bending cold or hot drilling holes for bolts in any shape or size for holding GI pipe with pole and wall complete all as specified and directed by Engineer in Charge.
Supply and fix GI pipe 40mm bore light grade with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, nuts, bolts and washers complete all as specified and directred by Engineer-in-Charge.
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 5 star rating including fixed along walls including grouting fastening & fixing (04 Nos) 16mm dia 150mm long GI bolts & nuts, washers and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed by the Engr-in-charge. Make :- Havells, Bajaj, Surya, V Gaurd, Crompton Greaves, Racold, Jaquar & Co Pvt Ltd Note : PVC connection will be measured & paid separately.
M & L for making holes in the existing building walls in any type for fixing of exhaust fan 300mm sweep and making good to the surface of disturbed wall and colour wash / distempering the wall finish to match the existing colour complete all as specified & directed by Engr-in-charge.
S & F exhaust fan AC Single phase 220 / 240 volts size 300mm sweep with louvers including three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose / connector to exhaust fan including carefully taking down old unserviceable exhaust fan any size and kept in MES store complete all as specified & directed by Engr-in-charge. Note :- A Sum of Rs. 35,728.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 30 (Schedule of credit) of Tender Documents.
M/S BSS AND SONS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .