Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹45.9 L+₹3.0 L (7.05%)Rejected-Finance HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹47.3 L+₹4.4 L (10.3%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹47.7 L+₹4.8 L (11.2%)Rejected-Finance 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹47.7 L+₹4.9 L (11.3%)Rejected-Finance 12 L I G PRITAM NAGAR PRAYAGRAJ U P PIN 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹42.4 L
EMD Value
₹84,700
Closing Date
11 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST NEW CANTT ALLAHABAD
PROVN OF CERTAIN SANCTONED WORKS UNDER AGE BR-I AT NEW CANTT ALLAHABAD
2020_MES_352718_2
8898/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
NEW CANTT
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹84,700
Yes
2 Sept 2020
22 Jul 2020
13 Aug 2020
22 Jul 2020
11 Aug 2020
27 Jul 2020
60 days
Amount
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Demolition of cement concrete including floor tiles or stone in any description and any position etc and removal from site as required complete all as specified and directed.
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n. exc 1.5 m width and n. exc 1.5 m in depth for foundation etc or for shafts, wells,cesspits , manholes , pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out inh soft/loose soil complete all as specified and directed.
Rough excavation n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning filling in ,including spreading ,levelling,watering and well ramming in layers n exc 25 cm in soft/ loose soil complete all as specified and directed.
Removing excavated material exc 50 m but n exc 100 m distance and depositing as directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Removing excavated material exc 250 m but n exc 500 m distance and depositing as directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Spreading and levelling of soil in layers n exc. 25 cm thick and ramming well including watering as required for filling under floor complete all as specified and directed.
M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing,sub base of floor complete all as specified and directed.
M&L for PCC 1:5:10 type E2, using 40mm graded stone aggregate, as in foundation filing and mass concrete work complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in lintal band at any height complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajjas, shelves etc and the like, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface complete all as specified and as directed
Form work to sides and soffit of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc rough finished complete all as specified and as directed
Form work to soffits of suspended slabs such as roof slab etc. n.exc. 200mm thick for fair finished surfaces of concrete complete all as specified and directed.
Form work to chullah hood, chajjas, troughs and similar items including edges complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed
S&F TMT bars of 10mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed.
S&F TMT bars of 6 to 8mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed.
M&L for Mild steel bars (TMT bars) 5mm dia and over upto and including 10mm dia in strriups,spaces,nibs and binders complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for half brick thick wall fly ash bricks (old size), straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface,finished even and fair, mixed with WPC complete all as specified and directed. Note: WPC will be measured & paid separately under appropriate item.
M&L for 5 mm thick rendering in CM 1:3 on surfaces of ceiling and finished even and fair complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type B-2 using 20 mm graded stone aggregate in plinth protection finished even and smooth without using extra cement including necessary formwork and cutting of joints complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in surface channel and drain complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound when concrete is green,finished even and smooth without using extra cement complete all as specified and directed. Note: WPC will be measured & paid separately under appropriate item.
Supply only Liquid water proofing compound (ISI marked) complete all as spesified and directed.
M&L for water proofing treatment to roof and edges (vertical or tapered) etc. in following sequence:- (a) Properly cleaning and drying the surface (b) Applying a coat of bituminous primer @ 0.40 ltr / Sqm conforming to IS 3384-1986 and primer shall be allowed to dry over night. (c) Laying of 3mm thick APP membrane of (non-woven polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm ie overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed.(Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
M&L for 40mm thick brick tiles laid over 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on non assesible roof area complete all as specified and directed. Note: WPC will be measured & paid separately under appropriate item.
M & L for vitrified floor tiles of dark shed 10mm thick (square/ rectangular) area of each tile exc 0.42 sqm but not exc 1.0 sqm, in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for vitrified floor tiles of dark shed 10mm thick (square/ rectangular) area of each tile exc 0.42 sqm but not exc 1.0 sqm, in skirting/dado, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm, in skirting/dado, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
S&F powder coated anodised aluminium frame (min thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed at site by Engineer-in-Charge.
S&F powder coated anodised aluminium door shutters (min thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/m including necessary tower bolt, handle, joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified and directed at site by Engineer-in-Charge.
S&F powder coated anodised aluminium window & ventilator shutters (min thickness of powder coating 50 micron) side hung type without sash bars, aluminium sections weighting 0.55 Kg/ m includng necessary jointing cleats, glazing cloiups, rubber packing, anodised aluminium fittings such as peg stays 150 mm long (1 nos), hinges type B21, 100 mm long (2 nos) suitable handle (1 no) complete all as specified and directed at site by Engineer-in-Charge.
S&F powder coated aluminium anodised grills of bar size 6mm x 5 mm with square gap of size 75mm fixed with suitable aluminium channel of size 12-15 mm sectioncomplete all as specified and directed at site by Engineer-in-Charge.
S&F 75 mm size 4 levers aluminium mortice lock, vertical type complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F aluminium (extruded section) door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed.
S&F 5mm thick sheet glass, ordinary quality and glazing with beading in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 5mm thick sheet glass, ordinary quality and glazing with beading in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 5mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 4mm thick figured glass, pin head type and glazing with beading in squares exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with beading in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F for solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S&F 150mm long aluminium alloy floor door stopper ,fabricated type complete all as specified and directed.
S&F aluminium door strip with brush fixed as in door bottom fixed with nails or screw complete all as specified and directed.
S&F 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified.
S&F mild steel framed work as in doors or gates of angle iron,door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc. to prepared for hanging or sliding with including either hooks and hinges, also fastening and fixing and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L for 40 mm thick flush shutters with both face of is covered with decorative face veneer with lipping/frame to match of solid core construction with block board core and ply wood face panels, complete all as specified and directed.
S&F for steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for steel ventilators with top hung shutters including hinges with steel handle, and steel peg stay, complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 complete all as specified and directed.
S&F factory made solid PVC door frame of size 50 mm x 95 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed.
S&F factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick with partical board core (stile:), with 2,4 or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front Face & 2 mm Plain colour PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed.
S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed.
S&F 100 mm long extruded aluminium alloy butt hinges type B-21 complete all as specified and directed.
S&F for 150mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 100mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F 200mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
S&F prelaminated MDF type board 18/19 mm thick, interior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination as in Cupboard Shutter / Cupboard shelves with and including external teak wood lipping 6mm thick and 18/19 mm wide fixed with nails on edges complete all as specified and directed.
S&F 30mm width of flaps continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
S&F 100mm size decorative type mat finished cupboard handle complete all as specified and directed.
S&F 50 mm size magnate catcher for cupboard shutter complete all as specified and directed.
S&F vitreous China white single piece WC with PP wash down water closet pan (pedestal pattern) including inbuilt flush fixing bolts,PVC seat cover clossed pattern with flat bottom (white colour) and cover and mild steel chromium plated or aluminium hinging device & traps complete all as specified and directed. Make: Hindware/ Parryware/ Jaquar (SLS-WHT-6853S)
S&F vitreous china white colour counter top wash basin of size 400X 600X175 mm size including 32mm dia CP waste coupling,CP bottle trap and discharge pipe complete all as specified and directed. Make: Hindware/ Parryware/ Jaquar (SLS-WHT-6601)
Oval,circular or ractangular shape cutting in granite slab for fixing of WHB, Sink etc of desired size and shape including rounding of edege complete all as specified and directed. Note: Any type of breakage or damage of granite slab will be born by the contractor.
S&F vitreous china white colour half stall urinal (flat back) of 315x375x620mm size including 32mm dia CP coupling, CP urinal spredar with CP pipe up to angle cock, waste pipe etc with all fixing arrangement and pointing around urinal back complete all as specified and directed. Make: Hindware/ Parryware/ Jaquar (URS-WHT-13253)
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F for WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete all as specified and directed.
S&F for vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on MS bracket including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, waste fitting,pipe and union complete all as specified and directed.
S&F for PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S&F vitreous China wash down water closet pan (pedestal pattern) including 'P' or 'S' trap and including seat cover,fixing bolts, complete all as specified and directed.
S&F Vitreous China half stall urinal flat back complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)complete all as specified and directed.
S&F CP Urinal spreader for half stal urinal with CP pipe complete all as specified and directed.
S&F 15 mm bore CP fancy stop valve (concealed type) with long shanks and cup fixed with pipes complete all as specified and directed.
S&F 125 mm size fancy type chromium plated shower rose with swivel joints,and connecting rod including fixing to steel pipe or union complete all as specified and directed.
S&F grating doom 100 mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
M&L for 18 to 20 mm thick Granite work (table rubbed and polished) as in horizontal surface of WHB top, cooking platforms and similar works laid over and including 15mm thick screed bed in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for 18 to 20 mm thick Granite work (table rubbed and polished) as in vertical surfaces of wall, columns etc and similar works fixed over and including 10mm thick rendering in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F 15 mm bore CP central hole basin mixer (swan neck/head type) with regular spout fancy type, cast copper alloy with capstan heads,long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed.
S&F 15mm bore CP bib taps (fancy type) with crutch or butterfly handle,screwed down, screwed for iron pipes or brass ferrule complete all as specified and directed.
S&F 15mm bore CP two way bib taps (fancy type) with wall flange , fancy type, quarter turn, brass chromium plated, long body with capstan head and cup screwed down, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed.
S&F 15mm bore CP angle stop cock (fancy type) of screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed..
S&F 15mm bore CP two way angle cock (fancy type) with wall flange fancy type with long shunk with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F 15mm bore CP pillar tap (fancy type) cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified and directed.
S&F sheet glass shelf assembly 60cm long, 12cm wide, made out of 5.5 mm thick glass with CP bracket guard and railing, fancy type, fixed to plug with CP screws and cup washer complete all as specified and directed.
S&F chromium plated soap dish made of brass of any shape, fixed to wall with screws and pcv cleat complete all as specified and directed.
S&F health faucet with flexible pipe of one mtr length including wall hook for EWC complete all as specified and directed.
S&F flushing jet spray for pedestal pattern EWC including 1.00 m long flexible pipe and brass chromium plated nuts complete all as specified and directed.
S&F toilet paper holder CP fixed to wall with chromium plated brass screw complete all as specified and directed.
S&F 600 mm long tubular towel rail , brass chromium plated of 20 mm dia complete all as specified and directed.
S&F 200 mm round dia CP towel ring made of brass with all fixing arrangement complete all as specified and directed.
S&F ornamental designer looking mirror fancy type 5mm thick glass with chromium plated cleat of approved quality including polishing and finishing complete all as specified and directed.
S&F rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity( tripple layer wall construction , Cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F for 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and directed.
S&F for 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore GI tubes 'medium grade' galvanised with all fittings and fixed to walls and ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore GI tubes 'medium grade' galvanised with all fittings and fixed to walls and ceiling or laid in floor complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints laid in trench or in floor complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints laid in trench or in floor complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F 75 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore pipe complete all as specified and directed.
S&F 75 mm outlet dia PVC (SWR) floor trap plain with grating including jointing with solvent cement. complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110 mm outlet dia PVC (SWR) floor trap plain with grating including jointing with solvent cement. complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
M&L for Preparation of newly plastered surface of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L for Preparation of newly plastered surface of wall and applying two coats of internal plastic emulsion paint white or tinted on wall with one coat of internal base primer with and including 2 mm thick white cement wall care putty complete all as specified and directed.
M&L for Preparation of newly plastered surface of external wall and applying two coats of apex weather proof external paint on wall or facia with one coat of external base primer with and including 2 mm thick white cement wall care putty complete all as specified and directed.
M&L preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for Preparation of newaly plaster surface of wall and applying two coats of oil bound distemper over and including a coat of 2 mm thick white cement wall care putty complete all as specified and directed.
M&L for Preparation of newaly plaster surface of wall and applying two coats of cement base paint including one coat of primer complete all as specified and directed.
M&L for Preparation of newaly plaster surface of ceiling and applying two coats of cement base paint including one coat of primer complete all as specified and directed.
M&L for sand / crused stone dust filling under interloking paver block as in sand cussion bed including leveling complete all as specified and directed.
M&L for 60 mm thick M-35 grade factory made rubber moulded vobratory compacted cement concrete interlocking paver block in approved design and colour conforming to IS 15658-2006, with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete all as specified and directed.
S&F DWC pipe class- SN8 (double wall corrugated pipe of structured wall polyethelene piping systems) of 150 mm internal dia (with coupler and elastometric rubber sealing ring) with non smooth external annular corrugated and smooth internal surfaces (double wall) for non pressure underground sewerage and drainage application confirming to IS: 16098-2013 including all materials, labour, T&P required for proper completion of work complete all as specified and directed.
M&L for granular sub base of class-B type bed for laying of DWC pipe including packing under and haunching against the sides of pipes after they are laid & tested with approved sand complete all as specified and directed.
Cutting holes into existing manhole brick wall built in CM and connecting new drain pipe and making good to pipes including rendering to cuttting out existing benching as required for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 finishing smooth and reforming benching as required for intenal dia of pipe 150mm complete all as specified and directed at site by Engineer-in-Charge.
Surface excavation in any type of soil n-exc 30cm deep and average 15cm deep and getting out complete all as specified and directed
M&L for point wiring (concealed type) complete with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm( 22/0.30 or 30/0.25), 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface) and supply and fixing PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes using new modular MS sunk terminal boxes of thickness not less 1.22 mm, new 3 mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 complete all as specified and directed and suitable for the following: -
One light point or one fan point controlled by one, 1- way switch
One 3/5 pin socket outlet, 6 Amp on the same board with other switches
One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane. Note : Socket Outlet point provided beside to switch board on same wall will be measured as below the switch board
One 3/5 pin socket outlet, 6 Amp on “independent board”
All as per item No. 149 above but point wiring using 2.5 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 16 amps “ independent board”.
All as per item No. 149 above but point wiring using 4.0 sq mm (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 6 pin socket outlet ,suitable for 16 amps “ independent board”.
Supply & fixing ISI marked modular switch piano module button type, single pole, one way, 6 Amps, 240 volts for point wiring complete all as specified and directed .
Supply & fixing modular socket out let 6 pin, 06 Amps module flush type for point wiring complete all as specified and directed .
S&F fan regulator, modular type, 5 stepped, electronic type, single phase 230 volt including connection complete all as specified & directed.
Supply & Fixing switch socket combination multipurpose 2 in 1, 6 pin, 6 and 16 Amp, and flush type universal for power point wiring complete all as specified and directed .
Supply & fixing ceiling rose 3 pin/PVC/ polycarbonate, isolated body with colour ring for fan point wiring all as specified and directed .
Supply & fixing batten/angle holder with colour ring for light point complete all as specified and directed .
Supply & fixing surface & wall mounted light fitting in CRCA powder coated white housing complete with prewired suitable for ONE T8 LED tube along with supply and fixing two number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/Havells or as approved
Supply, fixing, connecting & testing energy efficient LED Bulkhead in high pressure die cast aluminium housing of system wattage - 10 Watt, lumen out put - 600 Lm, colour Temp - Cool White having Ingress protection - IP 66 complete all as specified and directed. Make -Philips/Havells/CG or as approved
Supply & fixing single phase & neutral MCB Distribution Box of 8 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 including cutting, chasing on wall to recess the same and dismantling the old complete all as specified and directed.
Supply & fixing Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. Make:Indo asian/ Havells/Hager or as approved
Supply & fixing MCB SPN, 40 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing MCB SP, 06 to 32 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing of MS terminal box fixed for geyser/AC by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket of current rating 20 amps complete with fixing one single pole MCB , 'C' series of current rating 25 amp including cutting, chasing in wall to recess the same and making good complete all as specified and directed.
Supply, fixing, connecting and testing Ceiling fan of 1200 mm sweep in white colour, 5 Star rated, nominal wattage -50 Watt (± 5 %) , speed - 350 RPM, Air dilivery - 215 CMM, with ISI Marked including accessories complete suitable for operating voltage 230 Volt AC including providing FR PVC insulated & PVC sheathed round flexible copper conductor wire of size not less than 0.5 Sqmm or 16/.20 mm in three core of length not more than 1.0 Mtr complete in all respect as specified and directed.
S&F ceiling light with recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36 Watt maximum, Colour Temp - 3000 to 6500 K, Lumen out put- 4200-4400 Lm, THD < 10%, PF > 0.95, having short circuit and surge protection 4 KVA with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. LED Light Model -RC380 B LED 42S of Philips or as approved.
Supply, fixing, connecting and testing LED street light fitting of 32/36 watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered plotted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and including PVC conduit 20 mm and PVC copper cable 2.5 sqmm 3 core from junction ploe box to fitting complete all as specified and directed. Make :- Philips/Havells/Syska LED or as approved.
Supply & fixing street light bracket made out 32 mm dia bore G.I pipe, light grade of length not less than 1.2 Mtr, bend to required shape for holding the security light fitting including all required Clamps, nut & bolts for supporting the brackets etc. complete all as specified and directed.
Supply, fabrication, bending of mild steel flat iron to required shape as required/ directed shape including drilling hole, nuts, bolts and washers set of adequate size with one priming coat of red oxide with one finishing coat of aluminium paint and fixing on steel tubular pole fittings for supporting G.I. tubing/bracket/protection pipe/DB all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm bore GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a Cast Iron hinged cover resting over the Cast Iron frame painted with black bitumastic paint which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required.
M&L for sub main wiring of following sizes with FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core , 1100 Volts grade along with FRLS PVC insulated unsheathed flexible copper conductor (Multistrands) in green colour as continuous earth wire conforming to IS 694 with latest amendments and ISI marked, drawn with 25 mm nominal dia Rigid PVC conduit and making incoming / outgoing electric connections by using required size copper lugs / thimbles, making good to disturbed surface complete in all respect as specified and directed. Note :- 1. Cutting/chasing on wall shall be measured and paid seperately. 2. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (multistrand) of FRLS PVC insulated shall be measured and paid as one unit length.
2 x 6.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 4.0 Sqmm + 1 x 2.5 Sqmm earth wire
Cutting & chasing required not exceeding 10 cm girth on brick wall for concealed conduit sub main wiring and making good to disturbed surface with cement mortar 1:3 complete in all respect where as required/directed.
Supply & fixing exhaust fans AC single phase 230/ 240 V of size 300 mm sweep, double ball bearings heavy duty motor with louver, mounted on wall with taper nut sleeve anchor bolt fastener of suitable size complete all as required and as directed. Model - Ventil Air - DB of make Havells or its equivalent model in Crompton/V Guard/Venus/Bajaj
S&F sunk box with pressed MS/GI steel terminal boxes, flush type having 3 module of appx size 99 mm x 79 mm not less than 1.22 mm thick including new 3 mm thick laminated sheet cover of suitable size with brass screw and cup washers and cutting, making holes for mounting switch, socket regulator etc complete all as specified and directed.
S&F sunk box with pressed MS/GI steel terminal boxes, flush type having 8 module of appx size 135 mm x 132 mm not less than 1.22 mm thick including new 3 mm thick laminated sheet cover with brass screw and cup washers and cutting, making holes for mounting switch, socket regulator etc complete all as specified and directed.
Supply & fixing DB with Single phase MCB Distribution Box of 4 way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar, confirming to IS 13032 & 8623 complete all as specified and directed.
Cutting & Chasing required on on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 complete all as specified and directed.
Supply & fixing ISI Marked switch piano flush button type, single pole, one way, 6 Amps, 240 volts for point wiring complete all as specified and directed .
Supply & fixing socket out let 6 pin, 6 Amps flush type for point wiring and for point wiring and for point wiring complete all as specified and directed .
Supply & Fixing ISI Marked, medium step type fan regulator 80 Watt, 240 VAC for fan point wiring complete all as specified and directed .
Supply & fixing Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. Make:Indo asian/ Havells/Hager or as approved
Supply & fixing MCB with high rating MCB Triple pole, 100 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T or as approved.
Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 50 Sq mm 3.5 core with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep and getting out and laying LT UG Cable complete all as specified and directed .
Returning filling in with the soil obtained from item above here-in-before includiing spreading , leveling and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
R K CONSTRUCTION COMPANY
R.K.ASSOCIATES
MOHAMMAD RIZWAN CONTRACTOR
M/s SINGH CONTRACTOR WORKS
Avion Industries
Technological Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .