| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹49.1 L+₹60,205.34 (1.24%)Rejected-AOC | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹49.6 L+₹1.2 L (2.42%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE AF LOHEGAON
GE AF LOHEGAON PUNE-411032
MAINT, REPAIR, REPLACEMENT OF DEF ITEMS OF LT DISTRIBUTION SYSTEM, DBS, MCBS, CABLES AND ALLIED SERVICES AND REPAIR OF DEFECTIVE ITEMS OF STREET LIGHTS / SECURITY LIGHTS, DG SETS, AMF PANEL AND MISC ITEMS UNDER GE (AF) LOHEGAON AT 9 BRD AF STN PUNE
2024_MES_640473_1
8761
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
9 BRD AFS PUNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹99,000
Yes
5 Jul 2024
3 Feb 2024
14 Mar 2024
3 Feb 2024
9 Mar 2024
26 Feb 2024
Amount
Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed.
Dismantling / taking out insulator of any size / type from existing electric LT lines complete.
Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete
Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as directed.
Disconnecting of incoming / outgoing cables and earthing lead and taking out existing unserviceable outdoor feeder pillar box / Panel and removing unserviceable pillar box / Panel with frame from the PCC foundation complete all as directed.
Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site all as directed.( Excavation and earth work will be measured seperately)
M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed by Engr -in-Charge.
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete as specified.
Cutting/trimming of trees upto 150 mm girth including cutting of upper portion of branches above pole clearance up to 10 mtrs and disposal of same at a distance not exc 50 mtr and clearing of site complete as directed.(Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.) Note:Each Span will be measured from one pole to another pole
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed.
25 to 50 sqmm 3.5 core
70 to 150 sqmm 3.5 core
185-240 sqmm 3.5 core
300-400 sqmm 3.5 core
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm completed as directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm completed as directed
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole all as specified and directed at site.
Material and labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections, including nut bolts, washer welding bending cold/ hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one premer coat of red oxide primer, one under coat and one finishing coat of aluminium paint all as directed and as specified.
S&F shackle type insulator vitreous procelain white / brown / green with and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts all as directed and as specified.
M&L for providing pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron. Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade all as directed.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm all as directed
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation or as required on site etc complete all as directed by Eng-in-Charge
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as required on site etc complete all as directed by Eng-in-Charge
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc or as required on site etc complete all as directed by Eng-in-Charge
Supplying, spreading & leveling stone aggregate size of 40 mm grade to the existing sub station or all as specified and directed by Engineer-in-Charge.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:-
10 sqmm 2 core
16 sqmm 4 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
Relaying of old serviceable LT/HT under ground PVC/XLPE cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed by Engineer-in-charge. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measurement will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity 50 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 63 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply install, test and commissioning of Powder coated LT panel cubical out door type Channel mounted compartmentalized in construction all manufactured from CPRI approved manufacturer specified in list of makes of tender document, made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars of 400 A. incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have a bottom channel. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including disconnecting Existing cables & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts
a) Copper bus bar 400 Amps for 3 phase and Neutral b) MCCB FP 250 Amps 415 Volt 25 KA - 1 Nos c) MCCB FP 100 Amps - 415 Volt 16 KA - 2 Nos d) MCCB FP 63 Amps 415 Volt 16 KA - 4 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
All as per item no 58 but with the following acessories a) Copper bus bar 500 Amps for 3 phase and Neutral b) MCCB FP 315 Amps 415 Volt 36 KA - 1 Nos c) MCCB FP 100 Amps - 415 Volt 16 KA - 6 Nos d) MCCB FP 63 Amps 415 Volt 16 KA - 2 Nos d) MCCB FP 125 Amps - 415 Volt 18 KA - 1 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
All as per item no 58 but with the following acessories a) Copper bus bar 400 Amps for 3 phase and Neutral b) MCCB FP 160 Amps 415 Volt 36 KA - 1 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
S & F VTPN DB 4 Way sheet metal enclosure double door suitable for MCCB incommer and MCBs outgoing including MCCB 4P 125 Amps 10 KA complete all as speccified and directed including making good disturbed surfaces complete.
Supply and fixing SP 5 To 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
All as above as per item no 62 but SPN 32 Amps
All as above as per item no 62 but TP 25 to 63 Amps 415 Volts
S & F Sub Main Wiring with PVC Insulated multistranded copper conductor FRLSH single core wires of size 2x6.0 sq. mm + 1x6.0 sq. mm earth wire including PVC cassing and capping complete all as specified and directed
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed.
Opening/disconnecting the electrical connection of defective/burnt out underground LT Cable of any size 2 to 4 core from main switch/DB/ junction box / LT panel /LT OH line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/ connectors at cable end and reconnecting the cable in previous location with existing main switch/ DB/Junction box /LT Panel/ OH line etc complete all as directed.
Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels and complete area inside the fencing all as specified and directed by Engr-in-Charge Note : Item may be measured and paid more than one time as per site requirement to clean the E/M Installations
Supply and fix all in one solar street light fitting 20 watt having high lumen efficiency, including inbuilt solar panel and long life maintenance free lithium ferro phosphate battery micro controller based integrated MPPT charge controler with driver complete all as specified and directed by engr-in-charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm with GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified. Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3 ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
Supply and fix in repair / replacement of MCCB FP 1250 Amps Thermal magnetic Adjustable type microprocessor release with breaking capacity 65 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 6 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and as directed by Engineer-in-charge.
M/L for sub main wiring with two runs of single core 2.5 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 2.5 Sqmm copper cable & one run of 2.5 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
S&F of Sub main wiring with 4 X 10 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length).
M&L for Servicing of APFC panel of rating upto 200KVA including checking of CTs, control wiring, cleaning of panel and capacitor banks, tightning incoming and outgoing connections, supply and replacement of contactor, checking of capacitor banks, contact relay etc and making APFC panel serviceable complete upto satisfaction of Engr-In-Charge. (Note : Any minor/major spare part found faulty during checking such as contactor, CTs,contact relay and cable lugs , minor wire pieces including cost of T&P, multimeter etc shall be included in quoted rates of this item)
M & L for servicing of high mast light driving mechanism by checking alll electrical and machnical component, chain, pully, rope,. Motor etc and greasing oiling of chain, motor, pully etc servicing of motor, control panel, auxiliary contacts, replacement of u/s items i.e. toggle switch, indicator light, control wiring complete all as specified and directed.
Labour & Tools incl ladders to attanding general street light complaints for repair / maint of steert light/ flood light fitting any type and capacity after taking out from poles upto 11 mtrs height any place wihin the stn checking throughly function of drivers and connected item, removing carbon on joints, repairing of cable joints/ loose connection, making sholdering etc incl replacement of small parts like wire upto 1.5 mtr long, nut bolts, screws , insulation tape etc fixing on pole after carry out nacessary repairs and testing for smooth functioning complete all as specified and directed. Note : (a) Repairs may be carryed out as an when required basis on site i.e number of times and shall be measured and paid as per site requirement as per satisfaction of Engr-in-Charge and Spare parts like electronic drivers, ballast , lamp , ignator etc shall be measured and paid separately in respective items.
Lowering down of high mast light at any height repairing and replacement of unserviceable parts such as ignitor, capacitor, ballast, lamp electronic driver and internal and external circuit etc as required on site complete all as specified and directed. (Note : Spare / parts required for replacement shall be measured and paid seperately and lowering down work may be carry out as and when required basis for any kind of repair.)
Taking down the existing street light fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life LED Street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics IP 65/IP66 road way luminaries with LEDs as light source and lens embedded toughened glass and impact resistance of IK07 and electronic driver fixed on pole including connection complete all as specified and directed.
-ditto- all as per item Ser No 83.00 above but 60 Watt complete all as specified and directed
-ditto- all as per item Ser No 83.00 above but 70 Watt complete all as specified and directed
-ditto- all as per item Ser No 83.00 above but 90 Watt complete all as specified and directed
Taking down the existing Flood lights fitting and Supply & fix (in Repalcement) energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lens embedded toughened glass and impact resistance of IK07 and electronic driver fixed on high mast pole or any any other place as requird on site incl making all nacessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers complete all as specified and directed.
-ditto- all as per item Ser No 87.00 above but 120 Watt complete all as specified and directed
-ditto- all as per item Ser No 87.00 above but 180 Watt complete all as specified and directed
-ditto- all as per item Ser No 87.00 above but 200 Watt complete all as specified and directed
Taking down old,rusted, unsv Junction box of any size, type and supply & fix new junction box of size not less than 400 mm x300 mm x 190 mm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94 and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following complete all as specified and directed:- a) Four strip Aluminium Bus bar of capacity 100 A , 20 CM long- 01 Set b) MCB SP 10A-01 Nos
S&F in replacement of PVC insulated 1.5 sqmm copper three core conductor cable between cable loops box to fitting drawn through the pole/conduit complete all as specified and directed
S&F along pole PVC non metallic conduit of dia 20 mm medium grade including MS clamps and nut bolts etc for fixing along the pole complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 50 mm complete all as specified and directed
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core multistranded cable flat or circulas 4 sqmm incl taking out old unserviceable wire complete all as specified and directed.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core multistranded cable flat or circulas 10 sqmm incl taking out old unserviceable wire complete all as specified and directed.
Trimming for branches of trees, bushes, hurbs under over head line including removal of trees branches INCL CREEPERS etc to a distance not exceeding 5 mtr from over head line complete all as specified and directed.(Note: one span shall be considered as pole to pole distance between two poles)
Supply and fixing LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed.
Taking old unserviceable driver from LED light fitting and S&F LED outdoor driver with all Electricals connection as per existing make on site and testing for smooth functioning complete all as specified and directed. For following capacity of light fitting
(a) for LED light fitting 60-72 Watts
(b) for LED light fitting 80-120 Watts
(c) for LED light fitting 150 Watt
(d) for LED light fitting 250 Watt
(e ) for LED light fitting 300 Watt
Supply and fixing LED Bollard light fitting 8W IP 65 powder coated PDC aluminium body with opal diffuser weather proof 900 mm long suitable for landscape lighting incl making necessary arrangement for mounting fitting incl PCC work as reqd on site and testing complete all as specified and directed.
Taking down the existing highbay light fitting and Supply & fix (in Repalcement) energy saving and environmental friendly robost IP 65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount 120 Watt with system efficiency not less than 120 lm/W incl electronic driver fixed in ceiling/ suspended incl making all nacessary arrangement for fixing/hanging and anchering as required on site making electrical connections complete all as specified and directed.
Taking out carefully serviceable LT UG Cable/wires after disconnecting from DBs on wall/duct/cutting of walls of assorted size as required on site and re routing properly by making proper cutting in wall/cable duct clamping etc completed and making good disturbed surface of wall/floor as existing sourrounding complete all as specified and directed.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and directed.
S&F in replacement of old unserviceable contactor ML-3, 40 Amps power operating voltage 415 V AC Capacity. complete all as specified and directed
Taking out the old unserviceable all In one solar street light including solar panel from pole after disconnecting connection wires carefully, checking the connections, replacement of driver if unsv, cleaning of solar panel, checking of battery connectinsetc, making light serviceable and refixing at original position complete all as directed .
Cleanig of solar street light PV panel mounted on pole of any height for better efficiency of solar light ON MONTHLY BASIS complete all as directed.
Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to and including galvanised iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate no. 3 of SSR part I, and testing on completion including excavation and earth work in any type of soil, PCC 1:3:6 type C1 earthing chamber, precast slab 50 mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric (XPM) weight not less than 4kg/sqm, funnel with wire mesh, watering pipe of 20 mm bore medium grade GI pipe and lugs, earthing wire protected by galvanised iron or steel pipe 15 mm dia medium grade 7.5 metre long complete all as specified and as directed.
M&L for servicing of DG set 62.5 KVA to 125 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
M&L for servicing of DG set 160 KVA to 250 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed.( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
M&L for servicing of DG set 500 KVA to 750 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
Material only for the following item of DG set 62.5 KVA to 125 KVA DG set be incorporated in repairs for item No 112.00 complete all as specified and directed.
(a) Fuel Filter
(b)Oil Filter element with 'O' ring
(c) Fan belt
(d) Alternator belt
(e) Radiator hose pipe inlet/outlet
(f) Solenoid switch 12 volts,DC
(g) Oil Pressure Pipe
(h) Fuel Pressure Pipe
Material only for the following item of DG set 160 KVA to 250 KVA to be incorporated in repairs for item No 113.00 complete all as specified and directed.
(a) Fuel Filter
(b) Oil Filter element with 'O' ring
(c) Fan belt
(d) Alternator belt
(e) Radiator hose pipe inlet/outlet
(f) Solenoid switch 12/24 volts,DC
(g) Oil Pressure Pipe
(h) Fuel Pressure Pipe
Material only for the following item of DG set 500 KVA to 750 KVA to be incorporated in repairs for item No 114.00 complete all as specified and directed.
(a) Fuel Filter
(b)Oil Filter element with 'O' ring
(c) Fan belt
(d) Alternator belt
(e) Radiator hose pipe inlet/outlet
(g) Oil Pressure Pipe
(h) Fuel Pressure Pipe
M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 62.5 KVA to 125 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Note :-Repairs will be carried out from authorised workshop.
Taking down defective self starter 12 Volt of DG set of cap from 62.5KVA and below 125 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
(a) Rewinding the burnt field coil.
(b) Rewinding the burnt armature coil with commutator.
(c) Replacement of bush/ bearing.
(d) Replace the worm out carbon brush with brush holder.
(e) Replacement of clutch.
(f) Replacement of solenoid switch.
(g) Replacement of Bentex drive.
Taking down defective self starter 24 Volt of DG set of cap from 200 KVA to 750 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
(a) Rewinding the burnt field coil.
(b) Rewinding the burnt armature coil with commutator.
(c) Replacement of bush/ bearing.
(d) Replace the worm out carbon brush with brush holder.
(e) Replacement of clutch.
(f) Replacement of solenoid switch.
(g) Replacement of Bentex drive.
M&L for disconnecting the U/S alternator capacity of 62.5 KVA to 125 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning complete all as specified and directed.
Taking down old US contactor and S&F new contactor for the following range complete all as specified and directed.
(i) Power Contactor 40A, 415 volt, 4 pole with NO & NC as required
(ii) Power Contactor 80A, 415 volt, 4 pole with NO & NC as required
(iii) Power Contactor 225A, 415 volt, 4 pole with NO & NC as required
Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as specified and directed.
Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as specified and directed.
M & L for replacement of brass battery terminal suitable for lead Acid Battery 12 V 40 AH to 12 V , 180 AH complete all as specified and directed.
M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter complete and testing complete all as specified and directed. Note :- Spare parts required will be measured and paid separately under relevant item of this Schedule here after.
(a) Toggle switch suitable for AMF panel.
(b) CT's of range 62.5 to 400 KVA
(c) Relay of range 62.5 KVA to 400 KVA.
(d) Ammeter digital type square flush type
(e) Voltmeter digital type square flush type
(f) Copper wire single core for internal connection.
(g) Voltage monitoring relay (digital type)
(h) DG set AMF digital Controller
M&L for taking out diesel from the fuel tank of DG set of capacity 62.5 KVA to 125 KVA and cleaning the fuel tank complete of any size complete all as specified and directed..
M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type ccomplete all as specified and directed.
Supply only coolant for radiators of DG sets of capacity 30 KVA to 750 KVA complete all as specified and directed.
Supply only battery distilled water for batteries of DG sets complete all as specified and directed.
M&L for draining out old engine oil and filling new engine oil of grade as recommended by manufacturer for DG set any make and capacity complete all as specified and directed.
S & F in replacement of fuel indication transparent plastic tube of any size as per existing complete all as specified and directed.
Supply and fix in replacement of broken acoustic enclosure door hinges with stainless steel hinges complete with nut bolts etc as per site requirement of any type, cap and make of DG set complete all as specified and directed.
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 62.5 KVA to 160 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint complete all as specified and directed.
S&F Silencer with exhaust pipe complete bends, coupling etc suitable for 100 to 200 KVA DG set including fixing arrangements and painting with silver colour over a coat of red oxide primer complete all as specified and directed.
Supply & Fix in replacement of automatic voltage regulator 62.5 to 200 KVA DG set complete all as specified and directed.
Supply and fixing of PVC Insulated, PVC Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volt 1.5 sqmm and 7 core from DG set to AMF Panel complete all as specified and directed.
Supply and fixing of 180 AH maintenance free battery 12 volt into DG set with all necessary connections complete all as specified and directed.
Labour only for comprehensive maintenance of and attending day to day break down of DG Set including servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator with new at site complete all as specified and directed. Note:- (i) The maintenance cost of DG Set shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts and labour cost for fixing spares. (ii) All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’. (iii) Servicing shall be carried out authorised dealer of manufacturer i.e. OEM. (iv) Non attending the complaint with in 8 Hrs @ Rs. 2000.00/day shall be recovered by the contractor. (v) Keep the complaint pending after one day @ Rs.4000.00/day shall be recovered by the contractor. (vi) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge. (g) Spares shall be measured and paid separately. (h) Comprehensive maintenance of DG sets is applicable for contract period per job and shall be measured and paid once as one job on completion of contract only
(a) 62.5 KVA to 125 KVA
(b) 200 KVA to 250 KVA
(c) 500 KVA to 750 KVA
Aakar Constructions
sapana enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .