Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹12.0 L+₹80,385 (7.19%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.1 L+₹88,356 (7.90%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹12.2 L+₹1.0 L (9.24%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹13.3 L+₹2.1 L (18.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Addition Altration Bldg No P-10-13/C of MH under GE (N) ahmednagar
2020_MES_399018_1
8569 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹17,000
Yes
12 Jan 2021
28 Nov 2020
31 Dec 2020
28 Nov 2020
29 Dec 2020
12 Dec 2020
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site etc complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
M & L for 75 mm thick Cement concrete type D-2, (1:4:8) (using 40mm graded stone aggregate) etc complete all as specified and directed by Engineer-in-Charge
M & L for for non skid ceramic coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for Shahabad stone 20mm to 25mm thick flooring over and including 15mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
S&F of kota stone slab 20-25mm thick laid over & including 15 mm thick screed base in cement and sand mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for machined pressed precast concrete interlocking paver block glossy with grey cement and pagment, any shpae and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on stone masonry surfaces in cement and sand mortar (1:6) on wall finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 10 mm thick on concrete surfaces in cement and sand mortar (1:4) on ceiling finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc complete all as specified and directed by Engineer-in-Charge
M&L for 3 coats of white wash on newly plastered surfaces incl preparation on wall etc complete all as specified and directed by Engineer-in-Charge
M&L for 3 coats of white wash on newly plastered surfaces incl preparation on ceiling etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) etc complete all as specified and directed by Engineer-in-Charge
Taking down steel windows / ventilators, of any description and size etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm etc complete all as specified and directed by Engineer-in-Charge
S&F in repair Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm B.W.P. commercial plywood . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe etc complete all as specified and directed by Engineer-in-Charge
All as per item No 29 (here-in-before) but 20mm dia pipe.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per item No 32 (here-in-before) but 20mm dia pipe.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge
Dismantling of manglore pattern roofing tiles with ceiling tiles or slate roofing etc complete all as specified and directed by Engineer-in-Charge
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screwsaas specified etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 0.50 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified and directed by Engineer-in-Charge
M&L for Precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement and sand mortar (1:6) and pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1020 A(Oriental series) of MARC or equivalent make as mentioned in list of makes in Appendix `C'
Supply and fixing in repairs stop cock cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge Make : Cat Part No MOR 1320 (Oriental Series) of Marc or equivalent make as mentioned in list of makes in Appendix `C'
S&F in repairs, aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed by Engineer-in-Charge
M & L for for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness size,quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads n'exc 1.5 Sqm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 2000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
S & F of ball brass valve, 20mm bore dia of pipe, high pressure with polythene float and flynet complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge
Supplied and fixed 20mm Bore dia of pipe gun metal and glob or gate valve with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs 32 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
M&L for supply laying connecting, testing and commissioning and jointing LT underground cable in replacement . 1100 volts grade, XLPE insulated armoured with galvanized round steel wire or steel strip electric power cable heavy duty with multistrandad aluminum conductor laid in ducts fixed on poles /walls with proper size saddles and clamp complete all as specifed and as directed by the Engineer in charge of following size
(a) LT cable 70 sqmm 3.5 core
M&L for earthing of poles/system with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to GI strip 32x6 mm by means of nuts, bolts and washers and encased in and including 15 dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion. (Note: Any length of GI strip and 15 mm dia GI medium grade pipe shall be provided as per actual requirement at site)
M&L for switch fuse unit 4P, 415 volts 100 Amps capacity with suitable size etc complete all as specified and directed by Engineer-in-Charge
Labour for shifting of 30 Kg washing machine with drier and connected item from Bldg P-32 to New Bldg (Approx distance 500 m) all as complete electrical and water supply as in connection as previous bldg etc complete all as specified and directed by Engineer-in-Charge
Supply, Laying & Jointing pipe galvanized Medium class including fitting of size 50mm dia etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing valve butterfly conforming to IS 13095 of size 50mm dia etc complete all as specified and directed by Engineer-in-Charge
Supply and lay pipe galvanized Medium class including fitting of size 25 mm dia etc complete all as specified and directed by Engineer-in-Charge
Supply and fix valve butterfly conforming to IS 13095, of size 25mm dia etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge.. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one piano type switch 5 Amps single pole one way
One fan point controlled by one piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on same board controlled by one piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on independent board controlled by one piano type switch 5 Amps single pole one way
All as per Item No 61 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board
S&F switch piano flush type single pole, one way 5/6 Amps etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 2 in 1, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 in 1, 5/16 Amps flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet as required etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (TPN DB's) 415 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet complete all as specified and as directed.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, SPN, AC, 240 volts of 63 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 6 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil.etc complete all as specified and directed by Engineer-in-Charge
Supply and Lay HDPE pipe 50 mm dia for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 18,635.00 shall be deducted from BOQ on account of schedule of credit
MS. N.R. PENTA AND SONS
M/s Meher Construction
M/S-B.R.SONAWANE
M/s. Sagar Traders
M/s AG PATHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .